BrandONUEE
OriginGermany
ModelCONTHOS 3E PMD
Measurement PrincipleTemperature-Controlled Paramagnetic (Dumbbell-Type) Sensor
Response Time<5 s (gas-flow- and configuration-dependent, configurable integration time)
Measuring RangesUp to 3 independently configurable, switchable ranges (standard: 0–100% O₂ or 0–25% O₂
min. range0–5% O₂
max. range0–100% O₂)
Detection Limit<1% of span
Repeatability<±0.03% O₂
Inherent Linearity / Accuracy±0.1% O₂ (full scale)
Zero Drift<±0.1% O₂/week
Temperature EffectZero shift <±0.5% O₂ per 10 K
Tilt SensitivityBaseline shift of 0.02% O₂ per 1° deviation from horizontal
CalibrationManual 2-point (zero/span)
Pressure CompensationOptional, 800–1200 mbar abs (extendable on request)
Interference CompensationStatic and dynamic correction supported (requires proportional selectivity signal for dynamic mode)
Operating Detector Temperature55 °C
Enclosure RatingIP65 (per EN 60529)
Output InterfacesRS-485 (Modbus RTU), optional digital I/O panel for external range switching and threshold logic
Added to wishlistRemoved from wishlist 0
Add to compare
BrandONUEE
OriginGermany
ModelCONTHOS TCD Series
Measurement PrincipleThermal Conductivity Detection (TCD)
Operating Temperature RangeUp to 180 °C (HT variant)
Response Time (T90)≤3 s
Detection Limit≤0.5% of span
Accuracy & Linearity≤0.5% of span
Repeatability≤0.5% of span
Zero Drift≤1% of span/week
Span Drift≤1% of span/week
Environmental Temp. Range+5 °C to +45 °C
Protection RatingIP40 (3E), IP65 (3F/EX/HT)
Explosion ProtectionII 2 G, Ex p II T4 (3F-EX)
Analog Outputs2 × configurable (0–20 mA / 4–20 mA)
Digital InterfaceRS-485 Modbus RTU (optional)
Gas CompatibilityH₂, He, Ar, Cl₂, HCl, SO₂, H₂O (high dew point tolerant)
Flow Rate Range3–120 L/h
Power Supply100–240 VAC, 48–62 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandONUEE
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelUE5033 / UE5034
Price RangeUSD 4,200 – 7,000
H₂ Range (UE5033)0–100% vol
H₂ Range (UE5034)0–100% vol
Lower Detection Limit (LDL)0.5% vol
CO Range (UE5033)0–100 ppm
CO Range (UE5034)0–20% vol
H₂S Range (UE5033)0–1000 ppm
H₂S Range (UE5034)0–3% vol
T90 Response Time≤60 s (UE5033), ≤90 s (UE5034)
Accuracy (UE5033/UE5034)±0.4% (0–10%), ±0.7% (10–30%), ±1.0% (30–70%), ±1.2% (70–100%)
Repeatability±0.2–±0.5%
Operating Pressure0.95–1.1 bar abs (recommended), up to 7 bar abs
Process Gas Temperature−40 °C to +60 °C
Flow Rate0.1–10 NL/min (¾″ hose)
Humidity<95% RH (non-condensing)
Digital OutputRS485, Modbus RTU, 19200 baud, 8N2
Analog OutputOptional 4–20 mA module
Relay OutputOptional 4× SPDT relays
Power Supply9–48 VDC, 10 W
Dimensions151 × 40 × 40 mm
Weight0.4 kg
Enclosure RatingIP68
Operating Temperature−40 °C to +70 °C
Storage Temperature−40 °C to +105 °C
CertificationsCE, FCC, RoHS, WEEE, Conflict Minerals Compliance