Empowering Scientific Discovery

Shenzhen Angwei Electronics Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTesta
OriginGermany
ModeliFiD NMHC
Detection PrincipleFlame Ionization Detection (FID)
Instrument TypeOnline Analyzer
Measurement Range0–10,000 ppmC₁ (as methane equivalent)
Response Time1 s (T₉₀)
Detector Temperature190 °C
Filter Temperature300 °C
Repeatability±1% of full scale
Zero Drift±1% FS over 24 h
Warm-up Time15 min
Analog Output0–20 mA / 0–10 V
Digital InterfaceEthernet, RS232
Data StorageUSB
Remote AccessVNC/PC
Power Supply100–240 V AC, 50–60 Hz, 350 W
Operating Ambient Temperature0–45 °C
Enclosure RatingIP40
Dimensions19″ Rack, 133 × 482 × 420 mm
Weight15 kg
Fuel GasH₂ (Grade 5) or He/H₂ mixture
Zero GasN₂ or synthetic air
Calibration GasC₃H₈
Combustion AirInternally pumped
Fuel Consumption70 mL/min H₂ or 400 mL/min He/H₂
Calibration Gas Flow1 L/min
Pressure Compensation Range−150 to +500 hPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTesta
OriginGermany
ModeliFiD NMHC mobile
Detection PrincipleFlame Ionization Detection (FID)
Instrument TypePortable
Detection Range0–100,000 ppmC₁
Response Time1 s (T₉₀)
Repeatability±1% of full scale
Zero Drift±1% FS over 24 h
Detector Temperature190 °C
Hot Filter Temperature300 °C
Preheat Time15 min
Power Supply100–240 V AC, 50–60 Hz, 350 W
Operating Temperature0–45 °C
Enclosure RatingIP40
Dimensions178 × 370 × 420 mm
Weight12 kg
Fuel GasH₂ (Grade 5) or He/H₂ mixture
Calibration GasesC₃H₈, CH₄, C₂H₆
Zero GasN₂ or synthetic air
Burner AirBuilt-in pump
Fuel Consumption30 mL/min (H₂)
Calibration Gas Flow1 L/min
Pressure Compensation Range−150 to +500 hPa
Analog Output0–20 mA / 0–10 V
Digital InterfacesEthernet, RS232
Data StorageInternal via USB
Remote ControlVNC-compatible (PC/iFiD host)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandONUEE
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelUE55
Detection PrincipleFlame Ionization Detection (FID)
Instrument TypeOnline Continuous Analyzer
Measurement Range5 selectable full-scale ranges with auto-ranging capability
Response Time (T90)<1.5 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErsatec
OriginGermany
ModelSmartFID
Detection PrincipleFlame Ionization Detection (FID)
Instrument TypePortable
Typical ConfigurationComposite VOC Analyzer
Measurement Range0–100,000 ppm (as C₃H₈)
Resolution0.01 ppm
Accuracy±1.0% of reading
Response Time (T₉₀)1.5 s
Operating Temperature (Gas Path)Up to 200 °C (optional to 230 °C)
Sample Flow Rate0.8–1.0 L/min
Power Supply115–230 VAC, 48–63 Hz, 120–150 W
Dimensions420 × 470 × 310 mm
Weight16 kg
Fuel GasH₂ (Grade 5, hydrocarbon residual <0.5 ppm, 3 bar) or H₂/He mixture
Zero GasBuilt-in catalytic hydrocarbon scrubber or carbon filter
Analog OutputsTwo user-configurable 0/4–20 mA
Digital OutputsThree programmable relay contacts (250 V AC, 1 A)
Data StorageInternal XML logging, USB export to Excel-compatible format
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTesta
OriginGermany
ModeliFiD mobile
Detection PrincipleFlame Ionization Detection (FID)
Instrument TypePortable
Measurement Range0–30,000 ppmC₁
Response Time1 s (T₉₀)
Repeatability±1% of full scale
Zero Drift±1% FS over 24 h
Detector Temperature190 °C
Hot Filter Temperature300 °C
Warm-up Time15 min
Power Supply100–240 V AC, 50–60 Hz, 350 W
Operating Temperature0–45 °C
Enclosure RatingIP40
Dimensions178 × 370 × 420 mm
Weight12 kg
Fuel GasH₂ (Grade 5) or He/H₂ mixture
Burner AirBuilt-in pump, flow-controlled
Calibration GasesC₃H₈, CH₄, C₂H₆
Zero GasN₂ or synthetic air
Sample Flow ControlInternal pressure compensation (−150 to +500 hPa)
Analog Output0–20 mA / 0–10 V
Digital InterfaceEthernet, RS232
Data StorageUSB flash drive
Remote AccessVNC-compatible
OptionalIntegrated zero-air generator, thermal desorption cleaning cycle
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTesta
OriginGermany
ModeliFiD Rack
Detection PrincipleFlame Ionization Detection (FID)
Instrument TypeOnline Analyzer
Measurement Range0–10,000 ppmC₁ (as methane equivalent)
Response Time1 s (T₉₀)
Detector Temperature190 °C
Sample Line HeatingUp to 300 °C
Repeatability±1% of full scale
Zero Drift±1% FS over 24 h
Warm-up Time15 min
Analog Output0–20 mA / 0–10 V
Digital InterfaceEthernet, RS232
Data StorageUSB
Remote AccessVNC-compatible
Power Supply100–240 V AC, 50–60 Hz, 350 W
Operating Ambient Temperature0–45 °C
Enclosure RatingIP40
Dimensions19″ Rack Mount (133 × 482 × 420 mm)
Weight15 kg
Fuel GasH₂ (Grade 5) or He/H₂ mixture
Carrier/Combustion AirInternal pump, pressure-compensated (−150 to +500 hPa)
Calibration GasPropane (C₃H₈)
Zero GasN₂ or synthetic air
Fuel Consumption30 mL/min (H₂)
Calibration Flow1 L/min (iFiD Rack & iFiD NMHC), 2 L/min (iFiD Dual)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErsatech
ModelSmartFID ST
OriginGermany
Detection PrincipleFlame Ionization Detection (FID)
Instrument TypeOnline Analyzer
ConfigurationComposite VOC Analyzer
Measurement Range0–100,000 ppm (as C₃H₈)
Resolution0.01 ppm
Accuracy±1.0% of reading
Response Time (T₉₀)<1.5 s
Operating Temperature of Wetted Parts200 °C
Power Supply115–230 VAC, 48–63 Hz, max. 350 W
Dimensions177 × 445 × 365 mm (4U, 19″ rack-mountable)
Weight9 kg
Analog OutputsTwo user-configurable 0/4–20 mA
Digital OutputsThree programmable relay contacts (250 V AC, 1 A)
Sample Flow Rate~1.2 L/min
Zero Drift≤0.5% of full scale per month
Span Drift≤2.8% of full scale per week
Linearity±1.0% of selected range
Oxygen Interference<4% at 80 ppm C₃H₈
Warm-up Time25 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTesta
OriginGermany
ModeliFiD Dual
Detection PrincipleFlame Ionization Detection (FID)
Instrument TypeOnline Analyzer
Measurement Range0–10,000 ppmC₁ (as methane equivalent)
Response Time1 s (T₉₀)
Detector Temperature190 °C
Sample Line TemperatureUp to 300 °C
Repeatability±1% of full scale
Zero Drift±1% FS over 24 h
Warm-up Time15 min
Analog Output0–20 mA / 0–10 V
Digital InterfaceEthernet, RS232
Data StorageUSB
Remote AccessVNC-enabled
Power Supply100–240 V AC, 50–60 Hz, 350 W
Ambient Operating Temperature0–45 °C
Enclosure RatingIP40
Dimensions (W×H×D)482 × 133 × 420 mm (19″ rack-mountable)
Weight15 kg
Fuel GasH₂ (Grade 5) or He/H₂ mixture
Zero GasN₂ or synthetic air
Calibration GasPropane (C₃H₈)
Carrier/Burn AirInternally pumped
Fuel Consumption30 mL/min (H₂ only)
Calibration Gas Flow1 L/min (iFiD Rack & NMHC), 2 L/min (iFiD Dual)
Pressure Compensation Range−150 hPa to +500 hPa
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0