Empowering Scientific Discovery

Sielc Analytical Instruments (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSEAL
OriginGermany
Product TypeContinuous Flow Analyzer (CFA)
Wavelength Range340–900 nm
Sample Capacity120 / 180 / 270 positions
Reagent PositionsUnlimited
Flow Cell Path Length10 mm, 50 mm
Light SourceHigh-Pressure Krypton Lamp or LED
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSEAL
OriginGermany
ModelAA3
Product TypeContinuous Flow Analyzer
Wavelength Range340–900 nm
Sample Capacity120 / 180 / 270 positions
Reagent PositionsUnlimited
Cuvette Path Length10 mm, 30 mm, 50 mm
Light SourceHigh-Pressure Krypton Lamp / LED
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSEAL
OriginUSA
ModelAQ300
Instrument TypeDiscrete Analytical System
Sample ThroughputUp to 97 positions
Cuvette Pathlength10 mm
Optical CellFixed-position fused quartz cuvette
Detection PrinciplePhotometric absorbance measurement
Reaction ControlProgrammable incubation (seconds to minutes)
ComplianceEPA-approved methods, UK Blue Book validated, GLP/GMP-ready architecture
Automation LevelFully unattended overnight operation
Reagent ConsumptionOptimized for low-volume reagent use
Cross-contamination MitigationPost-measurement deep-cuvette wash cycle
Method FlexibilityUp to 7 analytes per sample, auto-standard curve generation, on-the-fly dilution and method switching
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThomas Cain
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported
ModelDEENA
Instrument TypeGraphite Digestion System
Automation LevelFully Automatic
Sample Capacity60 positions (50 mL per tube)
Temperature RangeAmbient to 230 °C
Temperature Control Accuracy±0.1 °C
Heating MechanismPTFE-coated graphite block heating module
Reagent Channels9 (including dedicated channel for oxidizing reagents, e.g., KMnO₄)
Standard Solution Channels6
Dimensions (H×W×D)44.5 × 80 × 49.5 cm
Power Supply120–240 V AC, 15 A
InterfaceRS-232 or USB
Reagent Dispensing Precision<0.025 mL or ±1%
Reagent Delivery Speed<4 mL/s
Final Volume Accuracy (50 mL)<±1%
Sample Rack Quantity3 × 20-position racks
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSEAL
OriginUSA
ModelAQ2
Instrument TypeLaboratory Water Quality Analyzer
Detection ParametersAmmonia-N, Nitrate, Nitrite, Phosphate, Total Nitrogen, Total Phosphorus, Hexavalent Chromium, Alkalinity, Color, Hardness, Chloride, Sulfate, etc.
ThroughputUp to 150 samples/hour
Reagents15 × 43 mL (on-board refrigerated)
Sample Capacity57 × 2 mL or 100 × 1.2 mL removable trays
Reaction TemperaturePrecisely controlled at 37 °C
Optical System7-position interference filter wheel (standard: 405, 480, 505, 520, 578, 660, 880 nm)
CalibrationLinear and up to 6th-order polynomial (20 calibration points supported)
Data OutputCSV, HTML reports
ComplianceCE-marked
Power110/115 V 60 Hz or 220/240 V 50 Hz
Dimensions68 × 41 × 55 cm (W × H × D)
Weight40 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSEAL
OriginUSA
ModelBD28 & BD50
Digestion Capacity28 × 250 mL or 50 × 75/100 mL
Temperature RangeAmbient to 450 °C
Temperature Control Accuracy±2 °C
Heating MechanismAluminum Block Heater
Automation LevelSemi-Automatic
Power Supply (Heater)220–260 VAC, 50/60 Hz
Power Supply (Controller)100–260 VAC, 50/60 Hz
Safety FeaturesOver-Temperature Cut-Off, Power-Fail Resume Logic, Acid-Vapor-Isolated Controller Housing
ComplianceDesigned for ASTM D129, ISO 11908, USP <231>, EPA Method 3050B/3051A/3052, and GLP/GMP-aligned workflows
Software Capability20 User-Defined Methods, up to 30 Steps per Method, Ramp Rate Adjustable from 1 to 30 °C/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSEAL
OriginGermany
ModelAA100
Product TypeContinuous Flow Analyzer
Wavelength Range340–880 nm
Sample Capacity180 positions / 120 cups
Reagent Positions17
Flow Cell Path Length10–50 mm
Light SourceLED
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSEAL
OriginNetherlands
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMinilab 1200 BOD
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSEAL
OriginGermany
ModelXY2-XY3
Sample Capacity180 (XY2) / 270 (XY3) positions
Compatible Vial Sizes0.5 mL, 2 mL, 4 mL, 5 mL
Sampling Probe MaterialStainless Steel Sleeve + PEEK Needle
Dual-Needle OptionAvailable
Wash StationFixed (no movement required)
Motion PrincipleRotating Carousel Architecture
ControlProgrammable Sampling Speed & Sequence
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSEAL
OriginUSA
ModelAQ700
Instrument TypeLaboratory Water Quality Analyzer
AnalytesAmmonium, Nitrate, Nitrite, Chloride, Orthophosphate, Sulfate, Silicate, Hexavalent Chromium, Fluoride, Total Alkalinity, Total Hardness, Calcium, Magnesium, Iron, Ferrous Iron, Manganese, Aluminum
ComplianceISO 15923-1 & ISO 15923-2
Optical CellQuartz, 1 cm pathlength (optional extended pathlength available)
Sample Handling4 robotic arms, 4 sample trays, programmable sample addition during run
Reagent ManagementCooled and uncooled reagent positions, up to 10 working standards per calibration curve
Detection PrincipleFixed-position photometric absorbance measurement in static quartz cuvette
Reaction ControlProgrammable incubation time (seconds to minutes), bubble-free segmented reaction simulation
Carryover PreventionProbe external-wall washing during vertical motion, post-measurement deep-cuvette cleaning
ThroughputHigh-capacity unattended operation (overnight, multi-shift)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSEAL
OriginGermany
ModelAA500
Product TypeContinuous Flow Analyzer
Wavelength Range250–880 nm
Sample Capacity180 positions / 120 cups
Reagent Positions34
Flow Cell Path Length10–50 mm (selectable)
Light SourceLED
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSEAL
OriginUSA
ModelAQ400
Instrument TypeLaboratory Water Quality Analyzer
Detection ParametersCOD, Ammonia-N, Nitrate-N, Nitrite-N, Orthophosphate, Hexavalent Chromium, Alkalinity, Color, Hardness
ComplianceEPA-Approved Methods
Optical CellQuartz, 1 cm standard pathlength (optional extended pathlength)
Sample/Reagent CapacityHigh-throughput carousel configuration
Automation LevelFully unattended operation with onboard cooling/non-cooling reagent positions
Detection PrincipleUV-Vis Spectrophotometry (Discrete Reaction Kinetics)
SoftwareMethod-driven, CFR Part 11-compliant data handling with audit trail
Regulatory AlignmentDesigned for GLP/GMP and ISO/IEC 17025 environments