- All
- Favorite
- Popular
- Most rated
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Product Type | Continuous Flow Analyzer (CFA) |
| Wavelength Range | 340–900 nm |
| Sample Capacity | 120 / 180 / 270 positions |
| Reagent Positions | Unlimited |
| Flow Cell Path Length | 10 mm, 50 mm |
| Light Source | High-Pressure Krypton Lamp or LED |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AA3 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–900 nm |
| Sample Capacity | 120 / 180 / 270 positions |
| Reagent Positions | Unlimited |
| Cuvette Path Length | 10 mm, 30 mm, 50 mm |
| Light Source | High-Pressure Krypton Lamp / LED |
| Brand | SEAL |
|---|---|
| Origin | USA |
| Model | AQ300 |
| Instrument Type | Discrete Analytical System |
| Sample Throughput | Up to 97 positions |
| Cuvette Pathlength | 10 mm |
| Optical Cell | Fixed-position fused quartz cuvette |
| Detection Principle | Photometric absorbance measurement |
| Reaction Control | Programmable incubation (seconds to minutes) |
| Compliance | EPA-approved methods, UK Blue Book validated, GLP/GMP-ready architecture |
| Automation Level | Fully unattended overnight operation |
| Reagent Consumption | Optimized for low-volume reagent use |
| Cross-contamination Mitigation | Post-measurement deep-cuvette wash cycle |
| Method Flexibility | Up to 7 analytes per sample, auto-standard curve generation, on-the-fly dilution and method switching |
| Brand | Thomas Cain |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | DEENA |
| Instrument Type | Graphite Digestion System |
| Automation Level | Fully Automatic |
| Sample Capacity | 60 positions (50 mL per tube) |
| Temperature Range | Ambient to 230 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Mechanism | PTFE-coated graphite block heating module |
| Reagent Channels | 9 (including dedicated channel for oxidizing reagents, e.g., KMnO₄) |
| Standard Solution Channels | 6 |
| Dimensions (H×W×D) | 44.5 × 80 × 49.5 cm |
| Power Supply | 120–240 V AC, 15 A |
| Interface | RS-232 or USB |
| Reagent Dispensing Precision | <0.025 mL or ±1% |
| Reagent Delivery Speed | <4 mL/s |
| Final Volume Accuracy (50 mL) | <±1% |
| Sample Rack Quantity | 3 × 20-position racks |
| Brand | SEAL |
|---|---|
| Origin | USA |
| Model | AQ2 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Parameters | Ammonia-N, Nitrate, Nitrite, Phosphate, Total Nitrogen, Total Phosphorus, Hexavalent Chromium, Alkalinity, Color, Hardness, Chloride, Sulfate, etc. |
| Throughput | Up to 150 samples/hour |
| Reagents | 15 × 43 mL (on-board refrigerated) |
| Sample Capacity | 57 × 2 mL or 100 × 1.2 mL removable trays |
| Reaction Temperature | Precisely controlled at 37 °C |
| Optical System | 7-position interference filter wheel (standard: 405, 480, 505, 520, 578, 660, 880 nm) |
| Calibration | Linear and up to 6th-order polynomial (20 calibration points supported) |
| Data Output | CSV, HTML reports |
| Compliance | CE-marked |
| Power | 110/115 V 60 Hz or 220/240 V 50 Hz |
| Dimensions | 68 × 41 × 55 cm (W × H × D) |
| Weight | 40 kg |
| Brand | SEAL |
|---|---|
| Origin | USA |
| Model | BD28 & BD50 |
| Digestion Capacity | 28 × 250 mL or 50 × 75/100 mL |
| Temperature Range | Ambient to 450 °C |
| Temperature Control Accuracy | ±2 °C |
| Heating Mechanism | Aluminum Block Heater |
| Automation Level | Semi-Automatic |
| Power Supply (Heater) | 220–260 VAC, 50/60 Hz |
| Power Supply (Controller) | 100–260 VAC, 50/60 Hz |
| Safety Features | Over-Temperature Cut-Off, Power-Fail Resume Logic, Acid-Vapor-Isolated Controller Housing |
| Compliance | Designed for ASTM D129, ISO 11908, USP <231>, EPA Method 3050B/3051A/3052, and GLP/GMP-aligned workflows |
| Software Capability | 20 User-Defined Methods, up to 30 Steps per Method, Ramp Rate Adjustable from 1 to 30 °C/min |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AA100 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 180 positions / 120 cups |
| Reagent Positions | 17 |
| Flow Cell Path Length | 10–50 mm |
| Light Source | LED |
| Brand | SEAL |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Minilab 1200 BOD |
| Pricing | Available Upon Request |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | XY2-XY3 |
| Sample Capacity | 180 (XY2) / 270 (XY3) positions |
| Compatible Vial Sizes | 0.5 mL, 2 mL, 4 mL, 5 mL |
| Sampling Probe Material | Stainless Steel Sleeve + PEEK Needle |
| Dual-Needle Option | Available |
| Wash Station | Fixed (no movement required) |
| Motion Principle | Rotating Carousel Architecture |
| Control | Programmable Sampling Speed & Sequence |
| Brand | SEAL |
|---|---|
| Origin | USA |
| Model | AQ700 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Analytes | Ammonium, Nitrate, Nitrite, Chloride, Orthophosphate, Sulfate, Silicate, Hexavalent Chromium, Fluoride, Total Alkalinity, Total Hardness, Calcium, Magnesium, Iron, Ferrous Iron, Manganese, Aluminum |
| Compliance | ISO 15923-1 & ISO 15923-2 |
| Optical Cell | Quartz, 1 cm pathlength (optional extended pathlength available) |
| Sample Handling | 4 robotic arms, 4 sample trays, programmable sample addition during run |
| Reagent Management | Cooled and uncooled reagent positions, up to 10 working standards per calibration curve |
| Detection Principle | Fixed-position photometric absorbance measurement in static quartz cuvette |
| Reaction Control | Programmable incubation time (seconds to minutes), bubble-free segmented reaction simulation |
| Carryover Prevention | Probe external-wall washing during vertical motion, post-measurement deep-cuvette cleaning |
| Throughput | High-capacity unattended operation (overnight, multi-shift) |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AA500 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 250–880 nm |
| Sample Capacity | 180 positions / 120 cups |
| Reagent Positions | 34 |
| Flow Cell Path Length | 10–50 mm (selectable) |
| Light Source | LED |
| Brand | SEAL |
|---|---|
| Origin | USA |
| Model | AQ400 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Parameters | COD, Ammonia-N, Nitrate-N, Nitrite-N, Orthophosphate, Hexavalent Chromium, Alkalinity, Color, Hardness |
| Compliance | EPA-Approved Methods |
| Optical Cell | Quartz, 1 cm standard pathlength (optional extended pathlength) |
| Sample/Reagent Capacity | High-throughput carousel configuration |
| Automation Level | Fully unattended operation with onboard cooling/non-cooling reagent positions |
| Detection Principle | UV-Vis Spectrophotometry (Discrete Reaction Kinetics) |
| Software | Method-driven, CFR Part 11-compliant data handling with audit trail |
| Regulatory Alignment | Designed for GLP/GMP and ISO/IEC 17025 environments |
Show next