Spectroscopy Instruments
Filter
Showing 541–570 of 2322 results
| Brand | Dynamica |
|---|---|
| Origin | Australia |
| Model | DNAmaster |
| Optical Design | Single-beam |
| Light Source | Long-life xenon lamp |
| Detector | CCD array |
| Wavelength Range | 200–900 nm |
| Absorbance Range | 0–4.0 OD |
| Wavelength Accuracy | ±1 nm |
| Slit Width | 4 nm |
| Noise | ~0.005 OD (RMS) |
| Drift | ~0.005 OD |
| Photometric Accuracy | ±0.01 OD |
| Photometric Repeatability | ±0.005 OD |
| Stray Light | 0.5% T |
| Minimum Sample Volume | 0.5 µL |
| DNA Detection Limit | 20 ng/µL |
| Data Storage | Internal memory or SD card |
| Power Supply | 110–240 V, 50/60 Hz |
| Energy-saving Mode | Yes |
| Startup Audio Selection | 7 options |
| Brand | Dynamica |
|---|---|
| Origin | Australia |
| Model | DB-30 |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1–5.0 nm (6 selectable slits) |
| Stray Light | ≤0.01%T (220 nm NaI, 340 nm NaNO₂) |
| Wavelength Accuracy | ±0.3 nm |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs, NIST 900D) |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs, NIST 930D) |
| Baseline Flatness | ±0.001 Abs (200–850 nm) |
| Baseline Stability | 0.0004 Abs/hr (500 nm, after 2 hr) |
| Noise Level | ±0.0003 Abs (500 nm) |
| Scan Speeds | 1–2,000 nm/min (8 selectable rates) |
| Light Sources | Tungsten-halogen & Deuterium lamps with automatic switching (325–370 nm) |
| Detector | Photomultiplier tube (PMT) |
| Control OS | Windows XP or Windows 7 Pro |
| Dimensions | 710 × 630 × 268 mm (W×D×H) |
| Net Weight | 50 kg |
| Power | 110–220 V AC, 50/60 Hz, 300 VA |
| Brand | Dynamica |
|---|---|
| Origin | Australia |
| Model | XB-10 VIS-20 |
| Wavelength Range | 190–1000 nm (XB-10), 330–1000 nm (VIS-20) |
| Spectral Bandwidth | 5 nm (XB-10), 8 nm (VIS-20) |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 1 nm |
| Photometric Accuracy | ±1% T |
| Photometric Repeatability | 0.50% T |
| Stray Light | <0.5% at 220 nm, 340 nm, and 360 nm |
| Noise | 0.004 A at 250 nm, 0 A |
| Absorbance Range | –0.3 to 1.999 A |
| Transmittance Range | 0–199.9% T |
| Concentration Range | –300 to 1999 (user-selectable resolution: 1, 0.1, 0.01, or 0.001) |
| Data Storage | SD card |
| Measurement Modes | Absorbance, Transmittance, Concentration, Multi-wavelength, Kinetic (Time Scan), Spectrum Scan |
| Peak Detection | Automatic peak/valley identification in spectral scans |
| Brand | Eachwave |
|---|---|
| Origin | Shanghai, China |
| Model | T-LSM100A |
| Minimum Step | 0.047625 µm |
| Standard Travel Options | 25 mm, 50 mm, 100 mm, 150 mm, 200 mm |
| Maximum Time Delay | >130 ps |
| Accuracy | ±35 µm |
| Repeatability | <3 µm |
| Backlash | <12 µm |
| Max Speed | 7 mm/s |
| Min Speed | 0.00022 mm/s |
| Peak Thrust | 55 N |
| Continuous Thrust | 25 N |
| Interface | RS232 (USB adapter available) |
| Power Supply | 12–16 VDC |
| Operating Temperature | 0–50 °C |
| Weight | 0.35 kg |
| Brand | East & West Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame AAS |
| Model | 7030A |
| Monochromator | Concave Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Spectral Bandwidth | 0.2 nm (measured spectral line half-width ≤ 0.2 nm ± 0.02 nm) |
| Sensitivity | Cu, 2.0 mg/L → Abs ≥ 0.200 Abs |
| Repeatability (RSD) | ≤1% |
| Detection Limit | Cu ≤ 0.010 mg/L |
| Brand | East & West Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Model | AA-7050 |
| Monochromator | Plane Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal |
| Resolution | ≤0.2 nm |
| Sensitivity | 0.0044 Abs for Cu (248.3 nm, 1 µg/mL) |
| Repeatability (RSD) | ≤0.8% (n=10) |
| Detection Limit | 0.002 mg/L for Cd (228.8 nm, graphite furnace mode) |
| Sample Introduction | Integrated AS-600 Autosampler (optional standard) |
| Lamp System | Automatic Hollow Cathode Lamp Selector with Encoding Recognition |
| Brand | East & West Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace Atomic Absorption Spectrometer |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Spectral Bandwidth | 0.1, 0.2, 0.4, 0.7, 1.0, 2.0 nm (auto-switching slits) |
| Resolution | <0.1 nm |
| Lamp Turret | 8-position, fully motorized and computer-controlled |
| Background Correction | Deuterium Lamp and Self-Reversal (SR) Methods |
| Baseline Stability | ≤0.003 A/30 min (dynamic), ≤0.002 A/30 min (static) |
| Characteristic Concentration (Cu) | <0.02 µg/mL |
| Detection Limit (Cu) | <0.003 µg/mL |
| RSD | ≤0.45% |
| Auto-Peak Search | Yes, including auto-zero, spectral scan, lamp alignment, mirror positioning, and energy balancing |
| Brand | East & West Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Peristaltic Pump |
| Detectable Elements | As, Se, Pb, Sn, Te, Bi, Sb, Hg, Cd, Ge, Zn |
| Relative Standard Deviation (RSD) | <1% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As, Se, Pb, Sn, Te, Bi, Sb < 0.01 µg/L |
| Brand | East & West Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit | Sub-ppb level |
| Precision (RSD) | ≤1.0% |
| Long-term Stability (RSD) | ≤2.0% |
| Wavelength Range | 180–500 nm |
| Optical Resolution | ≤0.012 nm |
| Brand | East & West Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ICP-7760HP |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Price Range | USD 70,000–100,000 (FOB Beijing) |
| Brand | East & West Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | ICP-7762 |
| Price | Upon Request |
| Wavelength Range | 165–800 nm |
| Observation Mode | Vertical Torch Dual-View Configuration |
| Detector | CCD with Auto-Adaptive Purge |
| Purge Gas System | Independent Dual-Path Purging (CCD + Optics Chamber) |
| Purge Gas Options | Argon or Nitrogen (Selectable) |
| Brand | AZ (Beijing Aozuo) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Benchtop |
| Integration | Fully Integrated System |
| Laser Source | Nd:YAG, 200 mJ @ 1064 nm (266 nm optional) |
| Repetition Rate | 20 Hz |
| Pulse Width | <6 ns |
| Spot Size | 20–200 µm (motorized adjustment) |
| Spectral Range | 190–1040 nm |
| Detector | Back-illuminated CCD with auto-height alignment |
| Safety Class | I (interlocked laser enclosure) |
| Software | ElementLIBS & NIST spectral libraries, PLS/PCA modeling, mapping, autofocus, dual-lens control (wide-field + magnified), gas flow regulation, soil/plant calibration databases |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | Ecodrone® |
| Pricing | Upon Request |
| Operating Principle | Push-broom Scanning |
| Imaging Method | Dispersive Optics |
| Deployment Mode | Airborne |
| Spectral Range | 400–1000 nm / 900–1700 nm (Hyperspectral), 905 nm (LiDAR) |
| Spectral Resolution | 5.5 nm (VNIR) |
| Ground Sampling Distance (GSD) | 3.5 cm @ 50 m AGL |
| Total Field of View (TFOV) | 38° |
| Instantaneous Field of View (IFOV) | 1024 × 640 pixels |
| Frame Rate | 330 FPS (HSI), 670 FPS (LiDAR) |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Ecodrone®-Kestrel |
| Pricing | Upon Request |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive (Prism-based) |
| Deployment Mode | Ground-based & Airborne Compatible |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 2.6 nm (FWHM) |
| Spatial Resolution (Detector Array) | 2048 pixels per line |
| Total Field of View (TFOV) | 40° |
| Instantaneous Field of View (IFOV) | 2048 × 1 pixel array (sensor-native sampling) |
| Frame Rate | 100 Hz |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Ecodrone-LiHT |
| Pricing | Upon Request |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Deployment Mode | Airborne |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 5.5 nm |
| Spatial Resolution (Hyperspectral) | 1024 pixels per line |
| Field of View (TFOV) | 38° |
| Frame Rate | 230 Hz |
| Thermal Sensor Resolution | 640 × 512 (standard), up to 1266 × 1010 (IR high-res mode) |
| Thermal Sensitivity | ≤0.03 °C |
| LiDAR Accuracy | 2.5 cm (standard), optional upgrade to 0.5 cm |
| LiDAR Return Channels | Up to 3 (standard), up to 15 (optional) |
| Point Density at 50 m AGL | ≥700 pts/m² |
| Brand | Edinburgh Analytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | DB30 |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth | 0.5, 1.0, 1.5, 2.0, 4.0 nm |
| Stray Light | ≤0.1% |
| Automation Level | Automatic Wavelength Scanning |
| Scan Speed | Up to 6000 nm/min |
| Brand | Edinburgh Analytical |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Wavelength Range | 200–900 nm |
| Excitation Source | Xenon Arc Lamp |
| Monochromator | Grating-Based |
| Slit Width | Adjustable (Multiple Bandwidths) |
| Spectral Resolution | 1.0 nm |
| Wavelength Accuracy | ±2.0 nm |
| Signal-to-Noise Ratio (S/N) | 15,000:1 |
| Maximum Scan Speed | 60,000 nm/min |
| Software | Spectracle™ |
| Brand | Edinburgh Analytical |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory Benchtop FTIR Spectrometer |
| Wavenumber Range | 350–8000 cm⁻¹ |
| Spectral Resolution | 0.5 cm⁻¹ |
| Signal-to-Noise Ratio (SNR) | 20,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector) |
| Wavenumber Accuracy | ±0.05 cm⁻¹ |
| Optical Design | Michelson Interferometer with KBr Beamsplitter and Dynamically Aligned Mirror Drive |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | FLS1000 |
| Dispersion Element | Grating Monochromator |
| Instrument Type | Steady-State and Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 0–30 nm |
| Optical Resolution | 0.05 nm |
| Sensitivity | 35,000:1 (RMS method) |
| Wavelength Accuracy | ±0.2 nm |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Model | FLS1000 |
| Spectral Range | 185 nm – 5500 nm |
| Lifetime Range | 10 ps – 10 s |
| Sensitivity (RMS) | >35,000:1 |
| Monochromator Focal Length | 325 mm |
| Grating Configuration | Interchangeable triple-grating turret (single- or dual-monochromator options) |
| Software | FluOracle® v4.x (supports ASTM E275, ISO 11698, USP <1031>, GLP-compliant audit trail & 21 CFR Part 11 optional modules) |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | FS5 v2 |
| Dispersion Element | Grating |
| Instrument Type | Steady-State and Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 0–30 nm |
| Optical Resolution | 0.01 nm |
| Sensitivity | 4000:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±0.5 nm |
| Excitation Sources | Xenon Arc Lamp, Pulsed Laser Diodes (e.g., 375 nm, 405 nm, 445 nm, 485 nm, 635 nm), Optional OPO/UV Laser Systems |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | IR5 |
| Instrument Type | Benchtop Laboratory FTIR Spectrometer |
| Wavenumber Range | 350–8000 cm⁻¹ |
| Spectral Resolution | 0.01 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 20,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector) |
| Wavenumber Accuracy | ±0.5 cm⁻¹ |
| Detector Options | Standard DTGS |
| Software Platform | Miracle™ v5.x |
| Optional Module | FT-PL (Fourier Transform Photoluminescence) with Integrated Laser Excitation Source |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LifeSpec II |
| Wavelength Dispersion Element | Dual Grating Monochromator |
| Spectral Bandpass (Slit) | 0–60 nm |
| Optical Resolution | 0.01 nm |
| Sensitivity (Signal-to-Noise Ratio) | 6000:1 |
| Wavelength Accuracy | ±0.1 nm |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LifeSpec II Series |
| Price | Upon Request |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LP980 |
| Pricing | Available Upon Request |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Mini-Tau |
| Spectral Dispersion | Interference Filter-Based |
| Instrument Type | Steady-State and Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 0–60 nm |
| Spectral Resolution | 50 nm |
| Signal-to-Noise Ratio | 3000:1 |
| Wavelength Accuracy | ±5 nm |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | RM5 |
| Instrument Type | Confocal Raman Microspectrometer |
| Spectral Range | 50–15000 cm⁻¹ |
| Spectral Resolution | ≥1 cm⁻¹ (FWHM) |
| Spatial Resolution | Down to 1 µm |
| Low-Wavenumber Cutoff | <50 cm⁻¹ |
| Spectral Reproducibility | ≤0.02 cm⁻¹ |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RMS1000 |
| Spectral Range | 50–30000 cm⁻¹ |
| Spectral Resolution | ≤0.1 cm⁻¹ (FWHM) at ≥800 mm focal length |
| Spatial Resolution | XY ≤ 0.5 µm, Z ≤ 1 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.02 cm⁻¹ |
| Brand | Ekspla |
|---|---|
| Origin | Lithuania |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported Instrument |
| Model | CARS |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 740–4000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | 0.5 µm |
| Minimum Wavenumber | 740 cm⁻¹ |
| Spectral Reproducibility | ±1% |
| Brand | Ekspla |
|---|---|
| Model | Fast Scan |
| Spectral Range | 0.2–3.5 THz (6–116 cm⁻¹) |
| Spectral Resolution (Fast Mode) | 10 GHz |
| Spectral Resolution (Fast/Slow Hybrid Mode) | 5 GHz |
| Acquisition Rate | 10 spectra/s |
| SNR | >10⁶:1 @ 0.4 THz |
| Origin | Lithuania |
| Import Status | Imported Instrument |
| Distributor Type | Authorized General Distributor |
| Category | Terahertz Time-Domain Spectroscopy (THz-TDS) System |