Spectroscopy Instruments
Filter
Showing 601–630 of 1322 results
| Brand | INNOTEG |
|---|---|
| Origin | China |
| Manufacturer Type | Manufacturer |
| Model | IUS-190 |
| Spectral Range | 190–3200 nm |
| Bandwidth (UV-VIS) | 0.2, 0.5, 1, 2, 3, 5 nm |
| Bandwidth (NIR) | 0.8, 2, 4, 8, 12, 20 nm |
| Wavelength Accuracy | ±0.5 nm (UV/VIS), ±2.0 nm (NIR) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS), ≤1.0 nm (NIR) |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | IUS-200-10 |
| Spectral Range | 280–2500 nm |
| Slit Bandwidth | UV-VIS: 0.2, 0.5, 1, 2, 3, 5 nm |
| NIR | 0.8, 2, 4, 8, 12, 20 nm |
| Wavelength Accuracy | ±0.5 nm (UV/VIS), ±2.0 nm (NIR) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS), ≤1.0 nm (NIR) |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | IUS-200-15 |
| Spectral Range | 280–2500 nm |
| Slit Bandwidth | UV-VIS: 0.2, 0.5, 1, 2, 3, 5 nm |
| NIR | 0.8, 2, 4, 8, 12, 20 nm |
| Wavelength Accuracy | ±0.5 nm (UV/VIS), ±2.0 nm (NIR) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS), ≤1.0 nm (NIR) |
| Integrating Sphere Diameter | 150 mm |
| Optical Design | Dual-beam, dual-grating, dual-detector architecture |
| Detector Configuration | Separate optimized detectors for UV/VIS and NIR ranges |
| Software Compatibility | Windows 7/10 |
| Data Export Formats | TXT, CSV, XLSX |
| Compliance Standards | GB/T 2680-2021, JGJ/T 151-2008, ISO 9050:2003, GB/T 22476-2008, GB/T 36261-2018, GB/T 25261-2010, JG/T 235-2014, JGJ/T 287-2014, GJB 798-90, GJB 2502.2-2006 |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | IUS-200-6 |
| Spectral Range | 280–2500 nm |
| Slit Bandwidth | [UV-VIS] 0.2, 0.5, 1, 2, 3, 5 nm |
| Wavelength Accuracy | ±0.5 nm (UV/VIS), ±2.0 nm (NIR) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS), ≤1.0 nm (NIR) |
| Brand | INSA Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 8000–350 cm⁻¹ (extendable to 12800–4000 cm⁻¹ in NIR |
| Spectral Resolution | 0.2 cm⁻¹ |
| Scan Speed | 2.5–60 kHz |
| Signal-to-Noise Ratio (SNR) | 40,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector) |
| Wavenumber Accuracy | < ±0.1 cm⁻¹ |
| Vacuum Level | ≤ 0.2 mbar |
| Optical Design | All-metal vacuum-sealed cast-aluminum interferometer housing with independent optical chamber |
| Brand | INSION |
|---|---|
| Origin | Germany |
| Model | 2C UV VIS |
| Optical Architecture | Single-beam |
| Detector Type | Photodiode Array |
| Spectral Range | 2 × 350–1050 nm |
| Wavelength Accuracy | < 10 nm FWHM |
| Spectral Resolution | < 10 nm FWHM |
| Sensitivity | > 2.0 × 10¹⁵ counts·nm/W·s at 650 nm |
| Optical Interface | Dual SMA 905 connectors |
| Calibration | Factory-calibrated, no user recalibration required |
| Mechanical Stability | Solid-state design, no moving parts |
| Operating Temperature Range | 5–40 °C |
| Dimensions | ≤ 65 × 45 × 25 mm |
| Weight | < 120 g |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | InverTau |
| Pricing | Upon Request |
| Dispersive Element | Filter-Based |
| Resolution | 4096 × 4096 |
| Brand | ISPEC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | Analytical System |
| Quotation | Upon Request |
| Instrument Category | Spectral Software & Database Suite |
| Instrument Type | Laboratory-Based |
| Wavenumber Range | 4000–400 cm⁻¹ |
| Resolution | 1 cm⁻¹ |
| Brand | JB |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | CCD-based Multi-Channel Array |
| Focal Length | 401 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 140–680 nm |
| Optical Configuration | Paschen–Runge Mount |
| Number of Simultaneous Analytical Channels | Not Applicable (Full-Spectrum CCD Acquisition) |
| Compliance | Meets ISO 11573:2021 (Metallic materials — Spark optical emission spectrometry), ASTM E415–22 (Standard Test Method for Analysis of Carbon and Low-Alloy Steel by Spark Atomic Emission Spectrometry) |
| Brand | JIACO |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | JIACO MIP |
| Pricing | Available Upon Request |
| Brand | Jingpu Technology |
|---|---|
| Origin | Henan, China |
| Model | JP-AFL25B |
| Instrument Type | Portable |
| FTIR Architecture | Interferometric (Michelson-type) |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Wavenumber Accuracy | ≤0.01 cm⁻¹ |
| Signal-to-Noise Ratio (SNR) | >45,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector) |
| Beam Splitter | Multi-layer coated KBr with hydrophobic coating |
| Detector | Dual-mode DTGS / MCT (user-selectable) |
| IR Source | Long-life air-cooled high-intensity broadband source |
| Scan Speed | Software-selectable, continuously variable (0.1–2.5 cm/s) |
| Optical Platform | Monolithic hardened aluminum base with integrated interferometer and detector chambers |
| Mirror System | Gold-coated corner-cube retroreflectors (monolithic, adhesive-free) |
| Environmental Protection | Industrial-grade resistive humidity control + physical desiccant barrier |
| Data Interface | USB 2.0/3.0 |
| OS Compatibility | Windows 7/10/11 (64-bit) |
| Software | IRPro v5.x (database-driven, ASTM E2412 & EN 14078 compliant modules included) |
| Certified Compliance | ISO 9001, AAA Measurement Management System, EMC-compliant per GB/T 18268.1–2010 (CNAS-verified) |
| Brand | JU CHUANG ENVIRONMENTAL |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Domestic |
| Model | UV-759CRT |
| Optical Design | Single-beam |
| Detector | CMOS array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | 0.1 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.05% T at 220 nm and 360 nm |
| Photometric Accuracy | ±0.003% T |
| Photometric Repeatability | 0.001% T |
| Absorbance Range | –0.30 to 3.00 A |
| Transmittance Range | 0.0–200.0% T |
| Concentration Range | 0–1999 units |
| Baseline Flatness | ±0.001 A |
| Stability | ±0.0005 A/h at 500 nm |
| Interface | USB (RS-232 emulation) |
| Display | 128×64 graphic LCD |
| Data Storage | 200 calibration curves + 200 measurement sets |
| Software Support | UV-759CRT dedicated analysis software |
| Brand | Kylin-Bell |
|---|---|
| Origin | Jiangsu, China |
| Model | BE-9000 |
| Spectral Range | 190–850 nm |
| Spectral Bandwidth | 190–850 nm (full-range xenon flash lamp) |
| Wavelength Accuracy | ±1 nm |
| Sample Volume | 0.5–2 µL |
| Optical Path Lengths | 0.05 mm, 0.2 mm, and 1.0 mm |
| dsDNA Quantitation Range | 2–15,000 ng/µL |
| Absorbance Accuracy | ±1% at 7.332 A (260 nm) |
| Absorbance Precision | 0.003 A (at 0.2 mm path) |
| Absorbance Linearity Range (10-mm equivalent) | 0.04–300 A |
| Measurement Time | <6 s |
| OD600 Range | 0.000–6.000 A |
| Detector | Hamamatsu UV-enhanced CMOS linear array sensor |
| Light Source | Pulsed xenon flash lamp |
| Display | 7-inch capacitive touchscreen (1024 × 600) |
| Operating System | Android-based embedded OS |
| Dimensions | 200 × 260 × 165 mm |
| Weight | 5 kg |
| Power Supply | DC 24 V adapter |
| Power Consumption | 25 W (operational), 5 W (standby) |
| Absorbance Stability & Repeatability | ≤0.5% (0–3 A), ≤2% (3–4 A) |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Model | LabAA 2000 |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Solid-State Detector |
| Background Correction | D₂ Lamp + Self-Absorption Method |
| Resolution | Mn Doublet (279.5–279.8 nm), Valley-to-Peak Ratio ≤30% at 279.5 nm |
| Sensitivity | Flame Mode — Cu Characteristic Concentration ≤0.035 mg/L |
| Precision (RSD) | Flame Cu (2 ppm) ≤1.0% |
| Detection Limits | Flame — sub-ppb to ppm range |
| Baseline Stability | ≤±0.003 Abs over 30 min at Cu 324.8 nm |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Liquid Disposal | Peristaltic Pump Extraction |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Rotameter |
| Detectable Elements | As, Sb, Bi, Hg, Se, Te, Sn, Ge, Pb, Zn |
| Relative Standard Deviation (RSD) | ≤0.7% |
| Linear Dynamic Range | ≥3 orders of magnitude |
| Detection Limits | As, Se, Bi, Pb, Sb, Te, Sn, Zn < 0.01 µg/L |
| Photomultiplier Tube (PMT) Wavelength Range | 160–320 nm |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit | <1 ppb (typ. for key elements) |
| Precision (RSD) | ≤1% |
| Stability (RSD, 4h) | ≤2% |
| Wavelength Range | 165–900 nm |
| Optical Resolution | 6 pm / 7 pm / 10 pm @ 257.610 nm (Mn line, measured) |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | LabICP 2000 ICP-OES |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Optical Design | Prism + High-Resolution Echelle Grating Two-Dimensional Cross-Dispersed System |
| Detector | Megapixel Large-Area CCD |
| Plasma Orientation | Vertical Torch |
| Observation Modes | Radial, Axial, Dual-View, and Attenuated Variants |
| Gas Control | Mass Flow Controllers (MFCs) for All Gases |
| Software | HiICP Platform with Real-Time & Offline Analysis Capabilities |
| Cooling | Thermoelectrically Cooled CCD with MPS Thermal Isolation Structure |
| Purge | Positive-Pressure Sealed Spectrometer Chamber with Independent Front-Optics Purge |
| RF Generator | Solid-State Crystal-Controlled RF Source with Real-Time Power Monitoring |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LBC-2 |
| Instrument Type | Benchtop |
| Integration | Fully Integrated |
| Laser Power | 10 mW |
| Laser Wavelength (Standard) | 532 nm |
| Spatial Resolution | 10 µm |
| Scan Area | 50 mm × 50 mm |
| Current Measurement Range | 10 fA – 20 mA |
| XY Stage Travel | ±25 mm (0.01 mm minimum step) |
| Laser Stability | ±5% / h |
| Laser Class | Class 2 (IEC 60825-1) |
| Operating System | Windows 7 (32-bit) |
| Dimensions (W×D×H) | 750 mm × 270 mm × 650 mm (excl. electrometer, stage controller, and PC) |
| Brand | East & West Analytical Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | LC-AFS Hyphenated System |
| Sample Introduction | Peristaltic Pump |
| Detectable Elements | As, Hg, Se, Sb |
| Relative Standard Deviation (RSD) | <3% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limit | sub-ng L⁻¹ level |
| LC Pump | Dual-piston reciprocating pump with PEEK fluidic path, 0–35 MPa (0–5000 psi) pressure range, flow rate programmable, pH 0–14 chemical compatibility |
| Post-column UV Digestion | Integrated, leak-proof, low-ozone emission |
| Flow Path Design | Minimized post-column volume for reduced band broadening |
| Software | Dedicated LC-AFS control and data acquisition software with Ethernet interface, gradient elution support, real-time chromatogram/fluorescence signal synchronization |
| Compliance | Designed to support GLP/GMP-aligned workflows |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | GDS-850 |
| Pricing | Upon Request |
| Brand | Lengguang Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | F93 |
| Price Range | USD 1,400 – 7,000 |
| Dispersive Element | Holographic Grating |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 12 nm |
| Spectral Resolution | 12 nm |
| Sensitivity | ≤1 × 10⁻⁹ mol/L (Quinine Sulfate in 0.1 M H₂SO₄) |
| Wavelength Accuracy | ±2.0 nm |
| Excitation Source | High-Stability LED |
| Brand | Lengguang Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Model | F96Pro |
| Wavelength Range (Excitation) | 200–850 nm |
| Wavelength Range (Emission) | 200–900 nm |
| Excitation Source | 150 W Ozone-Free Xenon Lamp (Hamamatsu, 2000 h lifetime) |
| Monochromator | Czerny-Turner grating monochromator with interference filters |
| Slit Width (Spectral Bandpass) | 10 nm |
| Spectral Resolution | 10 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ≤0.5 nm |
| Sensitivity (S/N) | >150:1 (at water Raman peak, 350 nm excitation) |
| Scan Speed | Up to 48,000 nm/min (10-point resolution) |
| Linearity (R²) | ≥0.995 |
| Standard Excitation Filter | 365 nm interference filter |
| Software | Quantitative & qualitative analysis suite with derivative spectroscopy (1st–4th order), multi-curve overlay, kinetic time-scan, spectral math, peak integration, and calibration curve fitting (linear, quadratic, cubic) |
| Brand | Lengguang Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Model | F96S |
| Dispersion Element | Holographic Grating |
| Slit Width (Spectral Bandwidth) | 10 nm |
| Spectral Resolution | 10 nm |
| Sensitivity | >90:1 (Water Raman SNR) |
| Wavelength Accuracy | ±1.0 nm |
| Excitation Wavelength Range | 250–600 nm (LED-based) |
| Emission Wavelength Range | 200–650 nm |
| Emission Wavelength Repeatability | ≤0.5 nm |
| Standard Excitation Sources | 365 nm, 376 nm, 392 nm, 405 nm LEDs |
| Scan Speed | Up to 48,000 nm/min |
| Normalization Function | Fluorescence Intensity Normalization |
| Software Modes | Fluorescence Intensity & Luminescence Intensity |
| Data Processing | 1st–4th Derivative Spectra, Peak Detection, Area Integration, Multi-Curve Overlay, Ratio Analysis |
| Quantitative Methods | Calibration Curve (1st–3rd order), Coefficient Method |
| Sample Forms | Liquid, Powder, Thin Film |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory workflows, supports GLP documentation practices |
| Brand | Lengguang Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Product Type | Domestic |
| Model | S22 / S22PC |
| Price Range | USD 420–690 (est.) |
| Optical Design | Single-beam |
| Detector | Silicon Photocell |
| Wavelength Range | 340–1000 nm |
| Wavelength Adjustment | Manual |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | ≤1.0 nm |
| Stray Light | ≤0.2% T |
| Photometric Accuracy | ±0.5% T |
| Photometric Repeatability | ≤0.2% T |
| Absorbance Range | –0.3 to 2.999 A |
| Transmittance Range | 0.0–199.9% T |
| Dimensions | 370 × 320 × 190 mm |
| Net Weight | 7 kg |
| Brand | Lengguang Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Model | S430 |
| Optical Design | Grating Scanning Monochromator |
| Wavelength Range | 900–2500 nm |
| Wavelength Accuracy | ≤0.2 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Spectral Bandwidth | 8 nm |
| Stray Light | ≤0.1% |
| Absorbance Noise | ≤0.0005 Abs |
| Measurement Mode | Transmission (Cuvette-Based) |
| Scan Speed | 1 spectrum per minute |
| Data Sampling Interval | 5 s |
| Data Interface | USB 2.0 |
| Dimensions | 360 × 460 × 240 mm |
| Weight | 12 kg |
| Chemometrics Software | CAUNIRS (developed in collaboration with China Agricultural University) |
| Brand | Lengguang Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | UV1901 |
| Optical Design | Dual-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 1 nm |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | ≤0.03% T (at 220 nm, using NaI) |
| Brand | Lengguang Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | UV1902 |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | ≤0.03% (T) at 220 nm (NaI) |
| Brand | Lengguang Tech. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | 721S |
| Optical System | Single-beam Czerny-Turner monochromator with sealed grating |
| Detector | Silicon photocell |
| Wavelength Range | 360–1000 nm |
| Wavelength Selection | Manual dial adjustment |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ±3.0 nm |
| Wavelength Repeatability | ≤1.5 nm |
| Stray Light | ≤1.0% T |
| Photometric Accuracy | ±0.8% T |
| Photometric Repeatability | ≤0.3% T |
| Photometric Range | 0.0–199.9% T / –0.3–2.999 A |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 370 × 320 × 240 mm |
| Net Weight | 4.0 kg |
| Brand | Lengguang Tech. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | 722S |
| Optical System | Single-beam Czerny-Turner monochromator with holographic grating |
| Detector | Photodiode array |
| Wavelength Range | 340 nm – 1000 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | ≤1.0 nm |
| Spectral Bandwidth | 6 nm |
| Stray Light | ≤0.5% T |
| Photometric Accuracy | ±0.5% T |
| Photometric Repeatability | ≤0.2% T |
| Photometric Range | 0.0–199.9% T / −0.3–2.999 A |
| Dimensions | 370 × 320 × 190 mm |
| Net Weight | 7 kg |
| Interface | RS232 serial port |
| Brand | Lengguang Tech. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | 722SP |
| Optical System | Czerny-Turner monochromator with holographic grating |
| Detector Type | Photodiode array |
| Wavelength Range | 325–1000 nm |
| Wavelength Selection | Manual adjustment |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | ≤1.0 nm |
| Stray Light | ≤0.2% T |
| Photometric Accuracy | ±0.5% T |
| Photometric Repeatability | ≤0.2% T |
| Absorbance Range | –0.3 to 2.999 A |
| Transmittance Range | 0.0–199.9% T |
| Light Source | 20 W / 12 V halogen lamp |
| Dimensions (W×D×H) | 370 × 320 × 190 mm |
| Net Weight | 7 kg |
| Interface | RS-232 serial port |
| Compliance | Meets GB/T 21186–2007 (Chinese national standard for visible spectrophotometers) |
