| Brand | LTB |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ARYELLE Butterfly |
| Price Range | USD 135,000 – 162,000 |
| Instrument Type | Benchtop |
| Integration | Integrated System |
| Laser Energy Range | 5 mJ – 850 mJ |
| Spectral Coverage | 190–950 nm (UV-VIS-NIR) + VUV extension via reflective optics |
| Spectral Resolution | <20 pm @ 200 nm |
| Spectral Resolution Power | >10,000 (practical, non-pixel-limited) |
| Detector Format | 1024 × 255 pixels, 26 × 26 µm, full-well capacity 1 Me⁻ |
| Detector Cooling | −70 °C thermoelectric |
| Optional Detectors | EMCCD or ICCD |
| Focal Length | 400 mm per channel |
| f-number | f/10 |
| Calibration | Automated wavelength recalibration using Hg lamp and internal shutter |
| Optical Path | SMA-fiber-coupled for UV-VIS-NIR |
| Dual-Channel Architecture | Independent VUV and UV-VIS-NIR channels sharing one detector plane |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | ARYELLE150 |
| Instrument Type | Benchtop |
| Integration | Integrated |
| Laser Energy Range | 5 mJ – 850 mJ |
| Spectral Resolution (λ/Δλ) | 6,000 – 15,000 |
| Wavelength Coverage (Single Acquisition, No Scanning) | 200–600 nm (configurable options: 220–800 nm, 200–590 nm, 230–548 nm) |
| Slit Width | 35 µm (customizable) |
| Spectral Sampling Rate | Up to 30 spectra/s |
| Detector Interface | Fiber-coupled (SMA) or free-space |
| Calibration Source | Integrated Hg lamp with automated wavelength recalibration |
| Spectral Accuracy | Better than 1/4 of spectral resolution |
| Detector Options | EMCCD (1004 × 1002, 8 × 8 µm pixels), Scientific Cooled CCD or ICCD (application-dependent) |
| Dark Current | 0.06 e⁻/pixel/sec (@ −50 °C) |
| Full Well Capacity | 32,700 e⁻ (linear) |
| Max EMCCD Gain | 4000 |
| Timing Resolution (LIBS gating) | 100 ns minimum step width |
| NIST Emission Database Integration | Yes |
| Automatic Spectral Line Identification | Yes |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | ARYELLE200 |
| Instrument Type | Benchtop |
| Integration | Fully Integrated |
| Laser Energy Range | 5 mJ – 850 mJ |
| Spectral Resolution (λ/Δλ) | 7,000 – 20,000 (practical) |
| Wavelength Coverage (single-shot, gap-free) | 200–750 nm (configurable options: 192–594 nm, 225–574 nm, 200–900 nm, 250–950 nm) |
| Slit Width | 45 µm (optional widths available) |
| Detector Interface | SMA fiber coupling or free-space input |
| Spectral Sampling Rate | Up to 30 spectra/s |
| Detector Options | ICCD (1024 × 1024, 13 × 13 µm pixels), scientific cooled CCD/EMCCD/EMICCD |
| Minimum ICCD Gate Width | 5 ns (optional down to 0.5 ns) |
| ICCD Max Relative Gain | 1000 |
| Dark Noise | 0.2 e⁻/pixel/sec |
| Full Well Capacity | 100,000 e⁻ |
| Calibration Source | Internal Hg lamp with automated software-driven recalibration |
| NIST Emission Database Integration | Yes |
| Automatic Line Identification | Yes |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | CORALIS |
| Instrument Type | Benchtop |
| Integration | Fully Integrated Dual-Modal Platform |
| LIBS Laser Energy | Up to 50 mJ (1064 nm, optionally 532 nm or 266 nm) |
| Raman Laser Power | Up to 50 mW (532 nm and 785 nm) |
| Spectral Coverage (LIBS) | 190–520 nm (scan-free) |
| Spectral Resolution (LIBS) | 0.013–0.035 nm |
| Spectral Coverage (Raman) | 530–950 nm (up to 6000 cm⁻¹) |
| Spectral Resolution (Raman) | 2.5–2.0 cm⁻¹ (532 nm), 1.7–1.4 cm⁻¹ (785 nm) |
| XYZ Stage Travel | X=50 mm, Y=50 mm, Z=35 mm |
| Positioning Accuracy & Repeatability | 1 µm |
| Macro Imaging Field | 28 × 19 mm (10×) |
| Micro Imaging Field | 3.5 × 2.5 mm (80×) |
| Dimensions | 1200 × 750 × 750 mm |
| Laser Safety Class | Class 1 |
| Software | FusionRL CORALIS |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | DEMON NIR Series |
| Form Factor | Benchtop |
| Integration | Integrated Monolithic Design |
| Optical Configuration | Littrow-Mounted Echelle Spectrometer with Dual Grating Architecture |
| Wavelength Range | 600–1700 nm |
| Spectral Resolution (λ/Δλ) | >60,000 (e.g., <0.026 nm @ 1550 nm, <0.01 nm @ 600 nm, 0.011 nm @ 656 nm) |
| Linear Dispersion | λ/90,000 |
| Minimum Measurable FWHM | ≤0.014 nm @ 800 nm |
| Spectral Window | 2.5–8 nm (wavelength-dependent) |
| Detector Interface | Scientific-grade InGaAs area detector (16-bit) |
| Relative Aperture | f/10 |
| Minimum Exposure Time | 1 ms (CCD-compatible) |
| Stray Light Level | Ultra-low (optimized Littrow echelle optical path) |
| Absolute Wavelength Accuracy | Pixel dispersion × 10 pixels |
| Active Wavelength Stabilization | Built-in Hg reference lamp + automated self-calibration |
| Control Interface | Full PC-based motorized control via USB/Ethernet |
| Dimensions (L×W×H) | 600 × 310 × 230 mm |
| Weight | 25 kg |
| Software Platform | SOPHI spectral acquisition & analysis suite (LabVIEW driver optional) |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | DEMON Series |
| Instrument Type | Benchtop |
| Integration | Integrated |
| Laser Energy Range | 5 mJ – 850 mJ |
| Wavelength Range | 175–1100 nm (configurable) |
| Spectral Resolution | down to 1.34 pm @ 200 nm |
| Spectral Resolving Power | 75,000–200,000 |
| Linear Dispersion | λ/225,000 |
| Absolute Wavelength Accuracy | ±0.25 pm (after auto-calibration) |
| Stray Light Level | <10⁻⁶ |
| Detector Compatibility | Scientific CCD, ICCD, EMCCD, EMICCD |
| Slit Control | Motorized |
| Shutter | Integrated Mechanical |
| Exposure Time | 1 ms (CCD), 5 ns / 2 ns (ICCD) |
| Interface | Full PC-based motorized control |
| Dimensions (L×W×H) | 750 × 310 × 230 mm |
| Weight | 25 kg |
| Software | Sophi (with embedded NIST spectral database), LabVIEW driver optional |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | LTB LIBSorter |
| Instrument Type | Benchtop |
| Integration | Integrated System |
| Laser Energy | 5 mJ – 850 mJ |
| Brand | Luchu Tech |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Detector Type | CCD |
| Spectral Range | 200–1100 nm |
| Optical Resolution | 0.11–3.42 nm (FWHM) |
| Signal-to-Noise Ratio | 1000:1 (full signal) |
| Dynamic Range | 4400:1 (single acquisition) |
| Stray Light | <1% |
| Detector | 2048 × 64 pixel back-illuminated CCD with single-stage TEC cooling |
| Pixel Size | 14 µm × 14 µm |
| Optical Design | Crossed Czerny-Turner |
| f-number | f/4 |
| Slit Options | 10 / 25 / 50 / 75 / 100 µm |
| Integration Time | 2.4 ms – 10 s |
| Linearity | ≥0.998 |
| A/D Resolution | 16-bit |
| Interface | USB 2.0 Type-B |
| Digital I/O | Yes |
| Fiber Connector | SMA905 |
| Weight | 1.25 kg |
| OS Compatibility | 32/64-bit Windows 7/10/11 |
| Brand | Luchu Tech |
|---|---|
| Model | SEER |
| Type | Confocal Micro-Raman Spectrometer |
| Excitation Wavelengths | 532 nm / 785 nm |
| Raman Shift Range | SEER-532: 150–3600 cm⁻¹ |
| SEER-785 | 200–2500 cm⁻¹ |
| Spectral Resolution | SEER-532: 7 cm⁻¹ (25 µm slit, measured) |
| SEER-785 | 6 cm⁻¹ (25 µm slit, measured) |
| Wavenumber Accuracy | ±3 cm⁻¹ |
| Detector Integration Time | 9.5 ms – 20 s |
| SNR | 600:1 |
| Dynamic Range | 79,000:1 |
| Laser Linewidth | <0.1 nm |
| Laser Output | Multimode/Single-mode options at 100 mW or 500 mW |
| Microscope Spot Size | 3 µm @ 100× (532 nm, measured) |
| Objective Lenses | Interchangeable 10×/20×/50×/100× |
| Illumination | LED white-light coaxial illumination |
| Tube Lens Focal Length | 180 mm |
| Software | RudeerTek RamanSoft (Windows 32/64-bit, Win7/10/11) |
| Interface | USB 2.0 |
| Brand | Luchu Technology |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Detector Type | CCD Array |
| Spectral Range | 200–1100 nm |
| Optical Resolution (FWHM) | 0.11–3.42 nm |
| Signal-to-Noise Ratio | 450:1 (full signal) |
| Dynamic Range | 2100:1 (single acquisition) |
| Stray Light | <1% |
| F-number | f/4 |
| Optical Design | Crossed Czerny-Turner |
| Slit Options | 10/25/50/75/100 µm |
| Pixel Array | 2048 × 64 pixels |
| Pixel Size | 14 µm × 14 µm |
| A/D Resolution | 16-bit |
| Integration Time | 2.4 ms – 10 s |
| Linearity | ≥0.998 |
| Interface | USB 2.0 Type-B, Digital I/O, SMA905 fiber port |
| Weight | 1.07 kg |
| OS Support | 32/64-bit Windows 7/10/11 |
| Brand | Luchu Technology |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM/ODM Producer |
| Model | SLAK |
| Detector | CMOS linear array sensor (2048 × 1 pixels) |
| Spectral Range | 200–1100 nm |
| Optical Resolution (FWHM) | 0.3–7 nm |
| Signal-to-Noise Ratio | 320:1 |
| Dynamic Range | 1500:1 |
| Stray Light | <1% |
| Optical Design | Symmetrical Czerny-Turner |
| f-number | f/7 |
| Cooling | Uncooled |
| Interface | USB Type-C, Digital I/O |
| Fiber Connector | Standard SMA905 (customizable) |
| Dimensions | 95 × 68 × 25 mm |
| Weight | 195 g |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiFlector |
| Beam Configuration | Single-beam |
| Detector Type | CCD (Charge-Coupled Device) |
| Wavelength Range | 290 nm – 1650 nm |
| Wavelength Accuracy | > ±20 nm |
| Stray Light | < 0.01% T |
| Automation Level | Automatic Wavelength Scanning |
| Sample Interface | Non-contact, optical surface |
| Measurement Time | ~20 s per analysis |
| Calibration | User-definable or factory-customized for specific product matrices |
| Product Parameter Output | Up to 4 simultaneous quantitative parameters per measurement |
| Preloaded Methods | Up to 8 product-specific analysis profiles |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | Fluorat-02-Panaroma |
| Wavelength Range (Excitation) | 210–840 nm |
| Wavelength Range (Emission) | 210–690 nm (up to 840 nm optional) |
| Spectral Resolution | <8 nm (15 nm optional) |
| Wavelength Accuracy | <3 nm |
| Signal-to-Noise Ratio | >100 (up to 200) |
| Slit Width (Spectral Bandpass) | 1.5 nm |
| Sensitivity | >200:1 |
| Detector | PMT |
| Light Source | Pulsed Xenon Lamp |
| Cuvette Volume | 0.01–3 mL |
| Dimensions | 400 × 355 × 150 mm |
| Weight | 13 kg |
| Power Supply | 110/220 V, 50/60 Hz, 60 W |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory |
| Model | InfraLUM FT-12 |
| Wavelength Range | 760–1150 nm |
| Spectral Resolution | 8 / 16 / 32 / 64 cm⁻¹ |
| Sampling Mode | Diffuse Reflectance / Transmission |
| Data Acquisition Interval | 1 cm⁻¹ |
| Scan Speed | 1 spectrum per second |
| Sample Volume | 50 mL |
| Analysis Time | ≤90 s |
| Dimensions | 530 × 450 × 380 mm |
| Weight | 32 kg |
| Power Supply | 220 V AC, 50 Hz |
| Power Consumption | 110 W |
| Chemometrics Software | RIM (with PARCLE integration) |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | InfraLUM FT-12 Industrial |
| Instrument Type | Laboratory |
| Principle | Fourier Transform (FT) NIR |
| Wavelength Range | 760–1150 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | Parcel |
| Sample Compatibility | Liquid, semi-solid, and homogeneous solid samples in transmission cells |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | FT-08 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 8000–350 cm⁻¹ |
| Resolution | 0.25–64 cm⁻¹ (selectable) |
| Scan Speed | 0.8 s at 16 cm⁻¹ |
| SNR | >75,000 (4 cm⁻¹, 1 min, 2150±50 cm⁻¹) |
| Wavenumber Accuracy | ±0.05 cm⁻¹ |
| Detector | High-Sensitivity DLATGS |
| Beamsplitter | KBr-coated Ge (8000–350 cm⁻¹), hermetically sealed and desiccated |
| Interferometer | Patented Suspended Double Cat’s Eye Design |
| Light Source | High-Stability Ceramic IR Emitter |
| Power Consumption | 65 W |
| Dimensions | 580 × 550 × 340 mm |
| Weight | 32 kg |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | MGA-1000 |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Concave Grating (1800 lines/mm) |
| Optical System | Quasi-Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect (50 kHz) |
| Spectral Resolution | 0.3 nm |
| Sensitivity | 0.3 A |
| RSD (Repeatability) | ≤0.3% |
| Detection Limit (Cu) | <0.006 µg/L |
| Max Graphite Furnace Temperature | 3000 °C |
| Heating Rate | Up to 7000 °C/s |
| Argon Flow Rate | <1 L/min (high-purity) |
| Wavelength Range | 185–900 nm |
| Typical LODs | Pb ≤0.05 µg/L, Cr ≤0.01 µg/L |
| Dimensions | 800 × 475 × 310 mm |
| Weight | 50 kg |
| Power Supply | 380 VAC, 50 Hz (3-phase) |
| Cooling | Integrated Closed-Loop Recirculating Water System |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | MGA-915MD |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Concave Grating (1800 lines/mm) |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Spectral Resolution | 0.3 nm |
| Sensitivity | 0.3 A (for Cu at 324.8 nm) |
| RSD (Repeatability) | <0.3% |
| Detection Limit (Cu) | <0.006 mg/L |
| Detection Limits (Typical) | Pb ≤ 0.05 µg/L, Cr ≤ 0.01 µg/L |
| Max Graphite Furnace Temperature | 2950 °C |
| Max Heating Rate | 7000 K/s |
| Argon Flow Rate (Ultra-High Purity) | <1 L/min |
| Wavelength Range | 190–900 nm |
| Dimensions | 800 × 570 × 390 mm |
| Weight | 75 kg |
| Power Supply | 380 V AC, 50 Hz (3-phase) |
| Cooling | Closed-Loop Recirculating Water System |
| Power Consumption | <0.2 kW (standby/analysis), <18 kW (atomization/cleaning) |
| Brand | LUCHI Technology |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM Manufacturer |
| Detector | CMOS Linear Array |
| Spectral Range | 200–1100 nm |
| Optical Resolution (FWHM) | 0.29–5.91 nm |
| Signal-to-Noise Ratio | 320:1 (full signal) |
| Dynamic Range | 1500:1 (single acquisition) |
| Stray Light | <1% |
| Pixel Count | 4096 × 1 |
| Pixel Size | 14 µm × 200 µm |
| Optical Design | Crossed Czerny-Turner |
| f-number | f/4 |
| Slit Options | 10 / 25 / 50 / 75 / 100 µm |
| Integration Time | 1 ms – 10 s |
| Linearity | ≥0.998 |
| A/D Resolution | 16-bit |
| Interface | USB 2.0 Type-B, Digital I/O |
| Fiber Connector | SMA905 |
| Weight | 460 g |
| OS Support | 32/64-bit Windows 7/10/11 |
| Brand | Luqi Technology |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM/ODM Producer |
| Origin Category | Domestic (China) |
| Model | LUNA-HS / UV-Enhanced |
| Detector | Linear CMOS Array |
| Spectral Range | 200–1100 nm |
| Optical Resolution | 0.39–6.6 nm (FWHM) |
| Signal-to-Noise Ratio | 320:1 (full signal) |
| Dynamic Range | 1500:1 (single acquisition) |
| Stray Light | <1% |
| Integration Time | 1 ms – 10 s |
| Linearity | ≥0.998 |
| A/D Resolution | 16-bit |
| F-number | f/4 |
| Optical Design | Crossed Czerny-Turner |
| Slit Options | 10 / 25 / 50 / 75 / 100 µm |
| Pixel Array | 2048 × 1 pixels |
| Pixel Size | 14 µm × 200 µm |
| Interface | USB 2.0 Type-B, Digital I/O, SMA905 fiber port |
| Weight | 460 g |
| OS Compatibility | 32/64-bit Windows 7/10/11 |
| Brand | LuQi Technologies |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM/ODM Producer |
| Origin Category | Domestic (China) |
| Model | LUNA-ST |
| Pricing | Upon Request |
| Detector Type | Linear CCD Array |
| Spectral Range | 350–1100 nm |
| Optical Resolution (FWHM) | 0.39–6.6 nm |
| Signal-to-Noise Ratio | 300:1 (full signal) |
| Dynamic Range | 1300:1 (single acquisition) |
| Stray Light | <1% |
| Focal Ratio | f/4 |
| Slit Options | 10 / 25 / 50 / 75 / 100 µm |
| Integration Time | 1 ms – 10 s |
| Linearity | ≥0.998 |
| A/D Resolution | 16-bit |
| Pixel Count | 2048 × 1 |
| Pixel Size | 14 µm × 56 µm |
| Optical Design | Crossed Czerny-Turner |
| Weight | 460 g |
| Interfaces | USB 2.0 Type-B, Digital I/O, SMA905 fiber port |
| OS Compatibility | 32/64-bit Windows 7/10/11 |
| Brand | LWLI |
|---|---|
| Origin | Fujian, China |
| Model | D-Series |
| Instrument Type | LC-AFS Hyphenated System |
| Sample Introduction | Peristaltic Pump |
| Waste Disposal | Peristaltic Pump Extraction |
| Hydride/Vapor Generation Mode | On-line UV Digestion + Chemical Reduction |
| Target Elements (Total) | Hg, As, Se, Sb, Bi, Pb, Cd, Ge, Sn, Te, Zn, Au |
| Target Species (Speciation) | As(III), As(V), MMA, DMA, monomethylmercury (MMHg), ethylmercury (EtHg), Se(IV), Se(VI), selenomethionine, antimony species, etc. (≥12 species) |
| RSD | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits (ng/L) | Hg ≤ 0.001 |
| PMT Wavelength Range | 160–320 nm |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Model | WD-2112B |
| Wavelength Accuracy | ±1 nm |
| Wavelength Range | 190–850 nm |
| Sample Volume Requirement | 0.5–2 µL |
| Optical Pathlengths | 0.02, 0.05, 0.2, and 1.0 mm |
| dsDNA Detection Range | 0–27,500 ng/µL |
| BSA Detection Range | 0.06–820 mg/mL |
| Fluorescence Sensitivity (dsDNA) | 0.5 pg/µL |
| Fluorescence Linearity | ≤1.5% |
| OD₆₀₀ Accuracy | ±0.005 A (0–2 A), ±1% (2–3 A), ±2% (3–4 A) |
| Absorbance Precision | ±0.005 A or ±1% |
| Spectral Resolution | <1 nm |
| Measurement Time | <5 s |
| Power Consumption (Operating) | 25 W |
| Dimensions | 200 × 260 × 165 mm |
| Weight | 5 kg |
| Brand | Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | 919650.1 |
| Optical Design | Single-beam |
| Detector | Photodiode Array |
| Wavelength Range | 340–960 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±1 nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | ≤0.5% |
| Automation | Automatic wavelength selection |
| Compliance | EN ISO 7027 for turbidity measurement |
| Brand | Macylab |
|---|---|
| Origin | Beijing, China |
| Model | UL-5000 |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±1% (0.76 at 260 nm) |
| Wavelength Repeatability | ≤0.5% for OD < 3, ≤2% for OD 3–4 |
| Photometric Range | 0–4.000 Abs (OD600) |
| Minimum Sample Volume | 0.3 µL |
| Pathlength Options | 0.02–1 mm (auto-adjustable), 1/2/5/10 mm cuvette |
| Absorbance Resolution | 0.002 Abs (1 mm path) |
| Detector | UV-enhanced CMOS linear array sensor |
| Light Source | Imported miniature xenon flash lamp (≥10⁹ flashes, >10-year lifetime) |
| Measurement Time | <3 s |
| Display | 7-inch Android-based touchscreen |
| Optical Principle | Fixed-pathlength, direct-drop microvolume absorbance measurement |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MaxiDirect |
| Pricing | Upon Request |
| Brand | MAYZUM |
|---|---|
| Model | MAZ-Ir100-AC |
| Type | Online NIR Analyzer |
| Wavelength Range | 4-channel NIR |
| Scan Speed | 30 ms |
| Moisture Range | 0.1–70% w/w |
| Resolution | 0.01% |
| Accuracy | ±0.2% (matrix-dependent) |
| Housing Material | SS316L |
| IP Rating | IP65 |
| Operating Temperature | −10 to 50 °C |
| Humidity Range | 10–90% RH |
| Power Supply | DC 24 V, 2 A |
| Output Interfaces | TCP/IP, RS485/RS232, Digital Alarm Outputs (2 channels) |
| Probe Cable Length | Standard 5 m (extendable to 100 m) |
| Installation Distance | 250 ± 100 mm (non-contact transmission mode) |
| Weight | ≈9.8 kg |
| Dimensions | 130 × 360 × 160 mm |
| Brand | MAYZUM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | MAZ-Ra300-Acr |
| Instrument Type | Online Raman Spectrometer |
| Spectral Resolution | 6 cm⁻¹ |
| Concentration Range | 0.1–99.9% |
| Resolution | 0.01% |
| Probe Length | 150 mm / 1 m (customizable) |
| Cable Length | Standard 5 m (extendable to 100 m) |
| Operating Temperature | −10 to 130 °C |
| Wetted Materials | Hastelloy C / PTFE / M400 / Non-contact optical path |
| Process Connection Options | Non-contact direct irradiation, immersion flange, sanitary clamp, NPT thread, flow cell |
| Power Supply | 220 V AC, <0.2 A |
| Output Interfaces | TCP/IP, RS-485/232 (digital), dual-channel relay (alarm & limit control) |
| IP Rating (wetted parts) | IP67 |
| Max Pressure Rating | ≤1 MPa |
| Net Weight | ≈5 kg |
| Dimensions | 280 × 485 × 590 mm (L×W×H) |
| Brand | MAYZUM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MAZ-Ra300-BSJZ |
| Instrument Type | Online Raman Spectrometer |
| Spectral Resolution | 6 cm⁻¹ |