Spectroscopy Instruments
Filter
Showing 751–780 of 2559 results
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | XplorAA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Resolution | <0.2 nm |
| Sensitivity | >0.8 A for 5 mg/L Cu solution |
| Precision (RSD) | <0.45% |
| Detection Limit | Sub-ppb for most elements with graphite furnace |
| Software Control | Handheld PC-based interface |
| Lamp Positions | 2 fixed hollow cathode lamp slots |
| Upgrade Path | Field-upgradable to graphite furnace and hydride generation systems |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | BFH-200 |
| Price | USD 27,500 (FOB Guangzhou) |
| Spectral Range | 350–7800 cm⁻¹ |
| Spectral Resolution | <1.0 cm⁻¹ |
| Signal-to-Noise Ratio | 40,000:1 (peak-to-peak, 4 cm⁻¹, 1 min scan) |
| Light Source | Ge-coated KBr beam splitter (imported) |
| Interferometer | Non-orthogonal Michelson-type with DSP-controlled electromagnetic drive |
| Detector | DLATGS with anti-humidity coating (imported) |
| Operating Systems | Windows XP through Windows 10 (64-bit compatible) |
| Dimensions | 450 × 350 × 210 mm |
| Weight | 13 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 7800–350 cm⁻¹ |
| Resolution | <1.0 cm⁻¹ |
| Scan Speed | 4 cm⁻¹ |
| Signal-to-Noise Ratio | 15,000:1 (at 4 cm⁻¹, 1 min scan) / 30,000:1 (at 4 cm⁻¹, 5 min scan) |
| Beamsplitter | KBr substrate with Ge coating |
| Detector | Imported high-sensitivity DLaTGS |
| Source | Imported long-life, air-cooled high-intensity IR source |
| Interferometer | Sealed 30°-incidence Michelson interferometer with automatic optical alignment |
| Laser | VCSEL-based He–Ne reference laser |
| A/D Conversion | 24-bit, 500 kHz |
| Communication Interface | USB 2.0 (backward compatible with USB 3.0) |
| Dimensions | 450 × 350 × 235 mm (L×W×H) |
| Weight | 14 kg |
| Operating Temperature | 15–35 °C |
| Power Consumption | <30 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | <1.0 cm⁻¹ |
| Scan Speed | 4 cm⁻¹ (optical path difference rate) |
| Signal-to-Noise Ratio | 15,000:1 (at 4 cm⁻¹, 1 min scan) / 30,000:1 (at 4 cm⁻¹, 1 min scan, DLaTGS detector) |
| Beamsplitter | KBr substrate with Ge coating |
| Detector | Imported high-sensitivity deuterated triglycine sulfate (DLaTGS) |
| Source | Imported long-life, air-cooled high-intensity IR source |
| Interferometer | Sealed 30°-incidence Michelson interferometer with integrated auto-alignment optics |
| A/D Conversion | 24-bit, 500 kHz |
| Communication Interface | USB 2.0 (backward compatible with USB 3.0) |
| Dimensions | 450 × 350 × 235 mm (L×W×H) |
| Weight | 14 kg |
| Operating Temperature | 15–35 °C |
| Power Consumption | <30 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | L9 |
| Wavelength Range | 190–1100 nm |
| Optical Design | Czerny-Turner Monochromator |
| Focal Length | 200 mm |
| Grating Density | 1600 lines/mm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5 nm (standard at 2 nm) |
| Wavelength Accuracy | ±0.3 nm (typical ≤±0.2 nm) |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.02% T (at 220 nm, NaI |
| Photometric Range | 0.0–200.0% T, –0.301–4.000 A, 0.000–9999 C |
| Photometric Accuracy | ±0.2% T, ±0.0009 A (0–0.5 A), ±0.002 A (0.5–1 A) |
| Photometric Repeatability | ≤0.08% T, ≤0.0004 A (0–0.5 A), ≤0.008 A (0.5–1 A) |
| Baseline Flatness | ±0.0006 A |
| Noise | 0.03% T / 0.00015 A |
| Baseline Drift | 0.0003 A/h (after 2 h warm-up at 250 nm & 500 nm) |
| Light Source | Imported deuterium lamp + tungsten-halogen lamp, auto-switching at 340 nm (adjustable) |
| Detector | Imported photodiode array or silicon photodetector |
| Display | 10.1″ capacitive touch screen, Android 10 OS, 262k-color, 178° viewing angle |
| Data Storage | 8 GB internal memory |
| Connectivity | USB port, Wi-Fi, Bluetooth |
| Software Options | UVWin8 PC software (optional), GLP-compliant data logging and audit trail support |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 7800–350 cm⁻¹ |
| Resolution | <1.0 cm⁻¹ |
| Scan Speed | 4 cm⁻¹ |
| Signal-to-Noise Ratio | 15,000:1 / 30,000:1 (at 4 cm⁻¹, 1 min scan) |
| Beamsplitter | KBr substrate with Ge coating |
| Detector | Imported high-sensitivity deuterated L-alanine triglycine sulfate (DLaTGS) |
| Source | Imported long-life, air-cooled high-intensity IR source |
| Interferometer | Sealed 30°-incidence Michelson interferometer with built-in auto-alignment optics |
| A/D Conversion | 24-bit, 500 kHz |
| Communication Interface | USB 2.0 (backward compatible with USB 3.0) |
| Dimensions | 450 × 350 × 235 mm (L×W×H) |
| Weight | 14 kg |
| Operating Temperature | 15–35 °C |
| Power Consumption | <30 W |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GDA 150 HR |
| Price Range | USD 210,000 – 280,000 |
| Brand | GDANA |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | SPEAR 500 |
| Pricing | Upon Request |
| Brand | Chemlab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GenesisRaman |
| Price Range | USD 630,000 – 775,000 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Resolution | ≤2 cm⁻¹ |
| Spatial Resolution | Lateral 1 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ≤±0.2 cm⁻¹ |
| Brand | Gentec-EO |
|---|---|
| Origin | Canada |
| Product Type | Laser Beam Diagnostic System |
| Model | BeamWatch Active |
| Wavelength Range | 190 nm – 11 µm |
| Measurement Principle | Non-contact, real-time camera-based beam profiling with ISO 11146-compliant M² calculation |
| Compliance | ISO 11146-1:2005, ISO 11146-2:2005, ANSI Z136.1 |
| Software | BeamWatch Studio v4.x (FDA 21 CFR Part 11 compliant audit trail, GLP/GMP-ready export) |
| Detector Type | High-dynamic-range CMOS sensor array with motorized neutral density filter wheel |
| Spatial Resolution | ≤ 5 µm (system-limited) |
| Frame Rate | Up to 60 Hz at full resolution |
| Data Output | ASCII, CSV, HDF5, TIFF, PNG |
| Interface | GigE Vision, USB 3.2 Gen 1 |
| Brand | GIT (Gas Imaging Technology) |
|---|---|
| Origin | USA |
| Model | Sherlock SF6 |
| Detector Type | Photomultiplier Tube (PMT) |
| Spectral Range | 10.5 µm |
| Spectral Bandwidth | 10.5 µm |
| Wavelength Accuracy | ±1 mL/min (7 lbs/year SF₆ detection limit) |
| Wavelength Repeatability | ±1 mL/min (7 lbs/year SF₆ detection limit) |
| Spatial Resolution | 320 × 240 pixels |
| Instantaneous Field of View (IFOV) | 0.4 mrad |
| Full Field of View (FOV) | 7.3° × 5.5° |
| Focal Length | 70 mm @ 8 µm |
| Aperture | f/2.38 @ 8 µm |
| NETD | <35 mK |
| Weight (w/o battery) | 12 lb (5.4 kg) |
| Weight (with battery) | 17 lb (7.7 kg) |
| Dimensions | 12″ L × 6″ W × 8″ H (305 × 152 × 203 mm) |
| Power Supply | 12 V rechargeable battery or AC adapter |
| Brand | GIT (Gas Imaging Technology) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Sherlock VOC |
| Price | Upon Request |
| Weight (without battery) | 6.8 kg (15 lbs) |
| Weight (with battery) | 8.6 kg (19 lbs) |
| Dimensions | 30.5 × 17.8 × 20.3 cm |
| Power Supply | 12 V rechargeable battery or AC adapter |
| Spectral Range | Pre-tuned to hydrocarbon absorption bands (MWIR, ~3 µm) |
| Aperture | f/2.5 at 3 µm |
| Focal Length | 75 mm at 3 µm |
| Instantaneous Field of View (IFOV) | 0.4 mrad |
| Total Field of View (FOV) | 7.3° × 5.5° |
| Spatial Resolution | 320 × 240 pixels |
| Minimum Detectable Leak Rate | 1 mL/min (≈1 g/hr for methane-equivalent VOCs) |
| Display | 640 × 480 LCD |
| Video Capture | Internal 14-bit frame grabber |
| Interfaces | Ethernet, RS-232, NTSC, S-Video, USB |
| Software | HyPAT™ for spectral analysis and quantitative gas mapping |
| Brand | GKINST |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Customizable |
| Pricing | Available Upon Request |
| Absorption Wavelength Range | 200–1100 nm |
| Emission Wavelength Range | 350–1100 nm |
| Excitation Laser Wavelength | 350–800 nm |
| Spatial Spot Size | 10 µm – 1 mm (continuously adjustable) |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | S5 |
| Instrument Type | Floor-Standing |
| Excitation Method | Spark |
| Focal Length | 500 mm |
| Groove Density | 3600 lines/mm |
| Wavelength Range | 130–900 nm |
| Detection Mode | Full-Spectrum CCD |
| Vacuum Optical Chamber | Integrated, Sealed |
| Elemental Coverage | C, P, S, N, Al, Ni, Cr, Mn, Cu, Mo, V, Ti, Co, Nb, W, Sn, Pb, Zn, Mg, Ca, Si, Fe, As, Bi, Sb, etc. |
| Brand | GreenSpectrum NIR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Optical Design | Grating Scanning System |
| Wavelength Range | 700–2500 nm |
| Sampling Mode | Integrating Sphere Diffuse Reflectance Unit |
| Data Output Modes | Absorbance (A), Reflectance (R), Spectral Radiant Energy (E) |
| Calibration Traceability | NIST-traceable standard materials with uniform wavelength calibration points across full spectral range |
| Model Transfer Capability | Verified inter-instrument model portability under ASTM E1655 and ISO 12099 protocols |
| Software Compliance | SmartScan (local control), SmartNet (networked LIMS/ERP integration) supporting audit trail, user access control, and 21 CFR Part 11–ready data integrity features |
| Regulatory Alignment | Designed for GLP/GMP-aligned workflows |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Type | Online & Portable NIR Spectrometer |
| Model | TruProcess |
| Measurement Principle | Diffuse Reflectance NIR Spectroscopy (900–2500 nm) |
| Optical Architecture | MEMS-based Scanning Grating |
| Scan Speed | ≤5 µs per spectrum |
| Sampling Interface | Non-contact, Programmable Triggered Acquisition |
| Process Integration | DIN-rail mountable, 4–20 mA / Modbus TCP / OPC UA ready |
| Compliance | Designed for GMP/GLP environments |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | DR/5000 |
| Optical Design | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1 nm (200–900 nm) |
| Spectral Bandwidth | 2 nm |
| Wavelength Resolution | 0.1 nm |
| Stray Light | <0.05% T at 220 nm |
| Absorbance Range | ±3.0 ABS |
| Measurement Modes | Transmittance (%T), Absorbance (ABS), Concentration |
| Data Storage Capacity | 2000 data points with timestamp, sample ID, operator code, and result |
| Interface | USB 1.1 (to PC, printer, external keyboard) |
| Power Supply | 200–240 V, 50/60 Hz |
| Weight | 15.5 kg |
| Operating Environment | 10–40 °C, ≤90% RH (non-condensing) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | DR2700 |
| Wavelength Range | 400–900 nm |
| Optical Bandwidth | 5 nm |
| Wavelength Selection | Automatic (method-driven) |
| Wavelength Calibration | Automatic |
| Measurement Modes | Transmittance (%), Absorbance, Concentration |
| Preloaded Methods | >130 |
| User-Defined Methods | 10 |
| Data Storage Capacity | 200 measurements |
| Display Interface | Touchscreen with Chinese language option |
| Power Supply | AC 100–240 V, 47–63 Hz |
| Weight | 4.0 kg (without battery), 4.3 kg (with battery) |
| Operating Environment | 10–40 °C, ≤80% RH (non-condensing) |
| Connectivity | USB port for firmware updates, data export, and peripheral integration (e.g., printers, flash drives) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | DR2800 |
| Price | Upon Request |
| Wavelength Range | 340–900 nm |
| Optical Bandwidth | 5 nm |
| Measurement Modes | Transmittance (%), Absorbance, Concentration |
| Data Storage Capacity | 500 test records |
| User-Defined Methods | Up to 50 |
| Preloaded Methods | 240+ |
| Power Supply | Rechargeable Li-ion battery or 100–240 V AC adapter |
| Weight | 4.06 kg (without battery), 4.38 kg (with battery) |
| Operating Environment | 10–40 °C, ≤90% RH (non-condensing) |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | DR3900 |
| Pricing | Available Upon Request |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | DR3900 |
| Optical Design | Single-beam (with reference compensation logic) |
| Detector | Photodiode Array |
| Wavelength Range | 320–1100 nm |
| Wavelength Accuracy | ±1.5 nm (340–900 nm) |
| Spectral Bandwidth | 5 nm |
| Wavelength Repeatability | <0.5 nm |
| Stray Light | <0.05% T at 220 nm (KCl) and <0.1% T at 340 nm (NaNO₂) |
| Display | 7″ TFT WVGA Color Touchscreen (800 × 480 pixels) |
| Data Storage | 2000 measurement records (including sample ID, operator ID, date/time, result) |
| Preloaded Methods | >220 EPA-, ISO-, and ASTM-compliant water quality methods |
| User Methods | Up to 100 custom programs |
| Barcode Recognition | Auto-identification of Hach TNTplus® and LCK vial barcodes |
| AQA Compliance | Automated Quality Assurance workflow with scheduled verification, standard validation, interference testing, and audit-trail logging |
| Connectivity | Dual USB ports (front/rear), 10/100 Mbps Ethernet, optional RS-232 |
| Software Integration | Compatible with Hach LINK2SC for bidirectional lab-to-field data synchronization and SC1000 controller correlation |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Dimensions | 151 × 350 × 255 mm (W × D × H) |
| Weight | 4.2 kg |
| Brand | Hach |
|---|---|
| Origin | Shanghai, China |
| Model | DR3900 |
| Wavelength Range | 320–1100 nm |
| Wavelength Accuracy | ±1.5 nm (340–900 nm) |
| Photometric Measurement Range | 340–900 nm |
| Spectral Bandwidth | 5 nm |
| Display | 7″ TFT WVGA Color Touchscreen (800 × 480 pixels) |
| Data Storage Capacity | 2000 measurement sets |
| Preprogrammed Methods | >240 |
| User-Defined Methods | 100 |
| Operating Environment | 10–40 °C, ≤80% RH (non-condensing) |
| Dimensions | 151 × 350 × 255 mm |
| Weight | 4.2 kg |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | DR3900 |
| Instrument Architecture | Dual-Beam |
| Detector Type | CCD Array |
| Wavelength Range | 320–1100 nm |
| Wavelength Accuracy | ±1.5 nm (340–900 nm) |
| Spectral Bandwidth | 5 nm |
| Stray Light | ≤0.001% T |
| Display | 7″ TFT WVGA Color Touchscreen (800 × 480 px) |
| Data Storage | 2000 Measurement Records |
| Preloaded Methods | >220 Standard Water Quality Methods |
| User-Defined Methods | Up to 100 |
| Barcode Recognition | Yes (Hach Predefined Reagents) |
| AQA Compliance Support | Yes |
| Connectivity | Ethernet, Dual USB Ports, Optional Printer Interface |
| Operating Environment | 10–40 °C, ≤80% RH (non-condensing) |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Dimensions | 151 × 350 × 255 mm |
| Weight | 4.2 kg |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | DR5000 |
| Instrument Architecture | Dual-Wavelength |
| Detector Type | CCD Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1 nm (200–900 nm) |
| Spectral Bandwidth | 2 nm |
| Stray Light | < 0.05% T (KI solution at 220 nm) |
| Automation Level | Automatic Wavelength Selection & Calibration |
| Data Storage Capacity | 2000 measurement records with timestamp, sample ID, operator code, and method metadata |
| Interface | USB 1.1 (for PC connectivity, printer, keyboard, and firmware/data transfer) |
| Power Supply | 200–240 V, 50/60 Hz |
| Weight | 15.5 kg |
| Operating Environment | 10–40 °C, ≤90% RH (non-condensing) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | DR6000 |
| Optical Design | Pseudo-Double-Beam |
| Detector | CCD Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Automation | Automatic |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±1 nm (200–900 nm) |
| Stray Light | <3.3 Abs / <0.05% T (KI solution at 220 nm) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | AFS-8900 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Peristaltic Pump |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| Detection Mode | Hydride Generation – Cold Vapor Atomic Fluorescence Spectrometry (HG-CV-AFS) |
| Automation Features | Onboard Calibration Curve Generation, Auto-dilution, Full Measurement Automation |
| Lamp System | High-Performance Encoded Hollow Cathode Lamps with Lifetime Monitoring |
| Atomizer | Shielded Low-Temperature Quartz Furnace Atomizer |
| Gas-Liquid Separator | Sealed Two-Stage Separation Unit |
| Gas Control | Array-Structured Argon Flow System with Flow Optimization Module |
| Software Platform | Windows 7/8/10/XP Compatible AFS Control Suite with Audit Trail & Data Export to Excel |
| Compliance Ready | Designed for GLP/GMP environments |
| Upgrade Interfaces | 预留形态分析、Hg/Cd电热蒸发接口 |
| Safety & Diagnostics | Real-time Argon-Hydrogen Flame Monitoring Window, Power Isolation Architecture, Self-Check & Fault Alert Protocol |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AFS-9530 |
| Price Range | USD 42,000 – 56,000 |
| Instrument Type | Single-Channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| RSD | <1.0% (typical for As at 1 µg/L) |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits (3σ) | As, Hg, Se < 0.01 µg/L |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-made) |
| Model | AFS-9560 |
| Price Range | USD 56,000 – 70,000 (FOB Beijing) |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| RSD | <1.0% (for As at 1 µg/L, n=11) |
| Linear Dynamic Range | >3 orders of magnitude (typical for hydride-generating elements) |
| Detection Limits | Sub-pg/mL level (e.g., As: 0.01 ng/L |
| Hg | 0.001 ng/L |
| Se | 0.03 ng/L, per ISO 17294-2 and GB/T 223.74–2021) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AFS-9600 |
| Price Range | USD 42,000 – 56,000 |
| Instrument Type | Single-Channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Peristaltic Pump |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au |
| RSD | <1.0% (for As at 1 µg/L) |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | Sub-pg/mL level for As, Hg, Se (e.g., As ≤ 0.01 µg/L, Hg ≤ 0.001 µg/L, Se ≤ 0.03 µg/L) |