| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 7800–350 cm⁻¹ |
| Resolution | Better than 1 cm⁻¹ |
| Scan Speed | 1 scan/sec |
| Signal-to-Noise Ratio | 45,000:1 (peak-to-peak, 4 cm⁻¹, 1-min background + sample scan, at 2100 cm⁻¹) |
| Detector | Imported High-Sensitivity DTGS or MCT (configurable) |
| Beamsplitter | Ge-coated KBr substrate |
| Source | Long-life Air-Cooled High-Intensity IR Source |
| Linearity | 0.1% |
| Dimensions | 430 × 360 × 200 mm |
| Weight | 15 kg |
| Interface | USB 2.0 |
| OS Support | Windows 7 Professional, Windows 10 Professional |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Benchtop FTIR Spectrometer |
| Instrument Architecture | Michelson Interferometer with Corner-Cube Retroreflectors |
| Optical Design | Double-Pass, Compensated Beam Path |
| Detector | High-Sensitivity DTGS with Optional MCT Upgrade |
| Spectral Range | 4000–400 cm⁻¹ (standard), extendable to 7800–350 cm⁻¹ |
| Resolution | ≤0.5 cm⁻¹ (user-selectable down to 0.25 cm⁻¹) |
| Signal-to-Noise Ratio | ≥30,000:1 (at 4 cm⁻¹, 1 min scan, peak-to-peak) |
| Scan Speed | Up to 10 kHz mirror velocity |
| Data Acquisition | 24-bit ADC, 125 kHz sampling rate |
| Compliance | ASTM E1421, ISO 17025 (when operated in accredited labs), USP <1119>, GLP-compliant data integrity architecture |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Benchtop FTIR |
| Spectral Range | 7800–350 cm⁻¹ |
| Resolution | < 0.5 cm⁻¹ |
| Scan Speed | 130,000 scans/sec (real-time dynamic mirror alignment) |
| Signal-to-Noise Ratio | 30,000:1 (at 4 cm⁻¹, 1-min scan) |
| Detector | Imported High-Sensitivity DLATGS |
| Beamsplitter | Ge-coated KBr substrate with hydrophobic anti-moisture layer |
| Laser Reference | He–Ne stabilized interferometer |
| Data Interface | USB 2.0 |
| Software Compliance | 21 CFR Part 11–ready audit trail, three-tier user permission architecture |
| Dimensions | 543 × 455 × 248 mm |
| Power Supply | AC 220 V / 50 Hz |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 200–800 nm |
| Spectral Resolution | ≤0.2 nm (at 500 nm) |
| Spatial Resolution | 0.2 nm (horizontal) |
| Minimum Wavenumber Coverage | ≥200 cm⁻¹ (calculated from 532 nm excitation) |
| Spectral Repeatability | ≤0.2 nm |
| Focal Length | 302.5 mm |
| f-number | f/5.5 |
| Grating Density | 1200 lines/mm |
| Slit Width | 0–2 mm (adjustable, 0.01 mm resolution) |
| Laser Source | 532 nm diode-pumped solid-state laser, ≥100 mW output |
| Detector | Photon-counting photomultiplier tube (PMT) with discrimination circuitry |
| Stray Light Level | ≤10⁻³ |
| Dimensions | 700 × 500 × 450 mm |
| Weight | 70 kg |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–7000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | X/Y-axis: 0.01 µm |
| Z-axis | 0.002 µm |
| Minimum Wavenumber | 20 cm⁻¹ |
| Spectral Repeatability | ≤0.2 nm |
| Monochromator Focal Length | 300 mm |
| Grating Density | 1200 grooves/mm |
| Wavelength Range | 200–800 nm |
| Slit Width | 0–2 mm continuously adjustable |
| Wavelength Accuracy | ≤0.2 nm |
| Laser Excitation Wavelength | 532 nm |
| Laser Output Power | 100 mW |
| Microscope Objective | Infinity-corrected semi-apochromatic fluorescence objectives (10×, 50×, 100×) |
| Eyepiece | PL10×/22 mm wide-field plan eyepiece with optional micrometer scale |
| Stage Travel | 76 mm × 50 mm (0.1 mm resolution) |
| CCD Camera | 16 MP ultra-high-definition imaging sensor |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Model | LRS-5 |
| Spectral Range | 50–7000 cm⁻¹ |
| Spectral Resolution | <1.5 cm⁻¹ |
| Spatial Resolution | X/Y = 0.01 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ≤1 cm⁻¹ |
| Focal Length | 800 mm |
| Laser Options | 532 nm (633 nm & 785 nm optional) |
| CCD Detector | 1650 × 200 pixels, 16 × 16 µm pixel size, active area 26.6 × 3.2 mm |
| Pinhole Apertures | 50, 150, 200, 400 µm |
| Wavelength Accuracy | ≤±1 cm⁻¹ |
| Sensitivity | Capable of resolving up to 4th-order Raman modes of crystalline silicon |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer | Gangdong Technology Co., Ltd. |
| Model | TG-FTIR |
| Instrument Type | Laboratory Benchtop System |
| FTIR Spectral Range | 7800–350 cm⁻¹ |
| FTIR Resolution | 0.5 cm⁻¹ |
| Scan Speed | 130,000 scans/sec |
| Signal-to-Noise Ratio | 30,000:1 |
| Gas Cell Path Length | 100 mm |
| Gas Cell Material | Stainless Steel |
| Gas Cell Internal Diameter (max/center) | 28 mm / 16 mm |
| Gas Cell Volume | 38.5 mL |
| IR Window | 38 × 6 mm BaF₂ or KBr (standard) |
| Transfer Line | 3 mm OD × 1 m PTFE-sheathed heated tubing |
| Gas Cell Max Temp | 300 °C |
| Transfer Line Max Temp | 230 °C |
| Temp Control Accuracy | ±1.0 °C |
| Detector | Imported High-Sensitivity DLATGS (Deuterated L-Alanine Doped Triglycine Sulfate), Liquid-Nitrogen-Free Operation |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | WGD-8 / WGD-8A |
| Application System | Emission Spectroscopy |
| Grating Configuration | Dual-grating turret |
| Spectral Resolution | ≤0.1 nm (WGD-8), ≤0.06 nm (WGD-8A) |
| Wavelength Range | 200–800 nm (PMT) |
| F-number | F/4 |
| Wavelength Accuracy | ±0.4 nm (WGD-8), ±0.2 nm (WGD-8A) |
| Wavelength Repeatability | 0.2 nm (WGD-8), 0.1 nm (WGD-8A) |
| Stray Light | ≤10⁻³ |
| Slit Width Adjustment | 0–2 mm, 0.01 mm resolution |
| Focal Length | 500 mm |
| Relative Aperture | D/F = 1/7 |
| Dimensions | 560 × 380 × 230 mm |
| Weight | 30 kg |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop |
| Spectral Range | 4000–400 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ |
| Scan Speed Options | 5 Adjustable Settings (Very Fast, Fast, Normal, Slow, Very Slow) |
| Signal-to-Noise Ratio | 15,000:1 (at 4 cm⁻¹, 1 min scan, DTGS detector) |
| Wavenumber Accuracy | ±4 cm⁻¹ (4000–2000 cm⁻¹), ±2 cm⁻¹ (2000–400 cm⁻¹) |
| Wavenumber Repeatability | ≤2 cm⁻¹ (4000–2000 cm⁻¹), ≤1 cm⁻¹ (2000–400 cm⁻¹) |
| Transmittance Accuracy | ±0.2%T (excluding noise floor) |
| Transmittance Reproducibility | ≤0.5%T (1000–930 cm⁻¹) |
| Baseline Flatness | ≤±0.2%T |
| Stray Light | ≤0.5%T (4000–650 cm⁻¹), ≤1.0%T (650–400 cm⁻¹) |
| Detector | Imported DTGS (Deuterated Triglycine Sulfate) |
| Data Interface | USB 2.0 |
| OS Compatibility | Windows XP, Windows 7 |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Product Type | Domestic |
| Model | Zhiview Smart |
| Price Range | USD 14,000–21,000 (FOB) |
| Instrument Category | Fourier Transform Type |
| Form Factor | Portable |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Resolution | 1 cm⁻¹ |
| Scan Speed | Software-selectable via PC control |
| Signal-to-Noise Ratio | 20,000:1 (peak-to-peak, 4 cm⁻¹, 1-min scan at 2100 cm⁻¹) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | Cintra1010 |
| Optical Design | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 2.0 nm (fixed) |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.01% T at 220 nm and 340 nm |
| Automation | Motorized Wavelength Scanning & Auto-Zero |
| Compliance | ASTM E275, ISO 6223, USP <857>, FDA 21 CFR Part 11 (with optional audit trail module) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | Cintra2020 |
| Optical Design | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1200 nm |
| Spectral Bandwidth | Adjustable from 1.0 to 5.0 nm |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | <0.01% T at 220 nm and 340 nm |
| Automation | Motorized Wavelength Scanning & Auto-zeroing |
| Compliance | ASTM E275, ISO 6223, USP <857>, FDA 21 CFR Part 11 (with optional audit trail module) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | Cintra3030 |
| Optical Design | Dual-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | Adjustable from 0.2 nm to 5.0 nm |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light | <0.0005% T at 220 nm and 340 nm |
| Automation Level | Motorized wavelength scanning and slit control |
| Compliance | ASTM E275, ISO 6223, USP <857>, FDA 21 CFR Part 11 ready (with optional audit trail module) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | Cintra4040 |
| Optical Design | True Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Automation | Fully Automatic |
| Slit Width Range | 0.1–2.0 nm |
| Stray Light | <0.0005% T at 220 nm |
| Photometric Linearity | ±1.2% up to 5 Abs |
| Monochromator Configuration | Dual Littrow, Czerny-Turner |
| Dynamic Range | >6 Abs (measured) |
| Compliance | ASTM E275, ISO 6358, USP <857>, EP 2.2.25, JP 2.03 |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | enduro Z-1000 |
| Instrument Type | Graphite Furnace AAS |
| Optical System | Dual-beam |
| Monochromator | Plane Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Adjustable Magnetic Field Strength | 0.6–1.0 T (0.1 T increments) |
| Lamp Holder | 8-position Auto-aligning |
| Wavelength Selection | Automatic |
| Slit Width | 0.1–2.0 nm (0.1 nm increments) |
| Hollow Cathode & Electrodeless Discharge Lamp Recognition | Encoded |
| Ultra-Lamp Power Supply | 10 V (1 standard, up to 4 optional) |
| Resolution | <0.2 nm |
| Sensitivity | ≤0.003 absorbance units for Cu at 324.8 nm |
| Detection Limit | ≤0.5 pg for Cd in graphite furnace mode |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Quantima / Integra |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit (Cu) | 0.7 ppb |
| Precision (RSD) | ≤0.5% |
| Long-Term Stability (RSD) | ≤1.0% |
| Wavelength Range | 160–800 nm |
| Optical Resolution | 0.006 nm (160–200 nm) |
| RF Generator Frequency | 40.68 MHz |
| Argon Consumption (aqueous samples) | <11 L/min |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | SavantAA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Resolution | 0.1 nm |
| Sensitivity | >0.9 Abs for 5 mg/L Cu solution |
| Repeatability (RSD) | 0.45% |
| Detection Limit | ≤0.003 ppm for Cu |
| Lamp Holder | 8-position Automatic with Auto-Alignment |
| Wavelength Selection | Automatic |
| Slit Width | 0.1–2.0 nm (0.1 nm increments) |
| Slit Height | Adjustable (Standard & Reduced) |
| Gas Control | Fully Automated with Safety Interlocks |
| D₂ Lamp Lifetime | Up to 10× Longer Than Conventional Lamps |
| Lamp Identification | Encoded HCL & EDL Recognition (Standard on SavantAA Σ, Optional on SavantAA) |
| EDL Power Supply | 10 V Optimized Design (1 Standard on SavantAA & SavantAA Si |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | SensAA |
| Instrument Type | Flame-Graphite Furnace Hybrid AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Resolution | 0.1 nm |
| Sensitivity | >0.8 Abs for 5 mg/L Cu solution |
| Precision (RSD) | ≤0.5% |
| Detection Limit | Cu ≤ 0.005 mg/L |
| Light Source Configuration | 6-target hollow cathode lamp turret enabling up to 13 element combinations |
| Integrated Control | Built-in 15″ Windows-based touchscreen PC |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | XplorAA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Resolution | <0.2 nm |
| Sensitivity | >0.8 A for 5 mg/L Cu solution |
| Precision (RSD) | <0.45% |
| Detection Limit | Sub-ppb for most elements with graphite furnace |
| Software Control | Handheld PC-based interface |
| Lamp Positions | 2 fixed hollow cathode lamp slots |
| Upgrade Path | Field-upgradable to graphite furnace and hydride generation systems |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | BFH-200 |
| Price | USD 27,500 (FOB Guangzhou) |
| Spectral Range | 350–7800 cm⁻¹ |
| Spectral Resolution | <1.0 cm⁻¹ |
| Signal-to-Noise Ratio | 40,000:1 (peak-to-peak, 4 cm⁻¹, 1 min scan) |
| Light Source | Ge-coated KBr beam splitter (imported) |
| Interferometer | Non-orthogonal Michelson-type with DSP-controlled electromagnetic drive |
| Detector | DLATGS with anti-humidity coating (imported) |
| Operating Systems | Windows XP through Windows 10 (64-bit compatible) |
| Dimensions | 450 × 350 × 210 mm |
| Weight | 13 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 7800–350 cm⁻¹ |
| Resolution | <1.0 cm⁻¹ |
| Scan Speed | 4 cm⁻¹ |
| Signal-to-Noise Ratio | 15,000:1 (at 4 cm⁻¹, 1 min scan) / 30,000:1 (at 4 cm⁻¹, 5 min scan) |
| Beamsplitter | KBr substrate with Ge coating |
| Detector | Imported high-sensitivity DLaTGS |
| Source | Imported long-life, air-cooled high-intensity IR source |
| Interferometer | Sealed 30°-incidence Michelson interferometer with automatic optical alignment |
| Laser | VCSEL-based He–Ne reference laser |
| A/D Conversion | 24-bit, 500 kHz |
| Communication Interface | USB 2.0 (backward compatible with USB 3.0) |
| Dimensions | 450 × 350 × 235 mm (L×W×H) |
| Weight | 14 kg |
| Operating Temperature | 15–35 °C |
| Power Consumption | <30 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | <1.0 cm⁻¹ |
| Scan Speed | 4 cm⁻¹ (optical path difference rate) |
| Signal-to-Noise Ratio | 15,000:1 (at 4 cm⁻¹, 1 min scan) / 30,000:1 (at 4 cm⁻¹, 1 min scan, DLaTGS detector) |
| Beamsplitter | KBr substrate with Ge coating |
| Detector | Imported high-sensitivity deuterated triglycine sulfate (DLaTGS) |
| Source | Imported long-life, air-cooled high-intensity IR source |
| Interferometer | Sealed 30°-incidence Michelson interferometer with integrated auto-alignment optics |
| A/D Conversion | 24-bit, 500 kHz |
| Communication Interface | USB 2.0 (backward compatible with USB 3.0) |
| Dimensions | 450 × 350 × 235 mm (L×W×H) |
| Weight | 14 kg |
| Operating Temperature | 15–35 °C |
| Power Consumption | <30 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | L9 |
| Wavelength Range | 190–1100 nm |
| Optical Design | Czerny-Turner Monochromator |
| Focal Length | 200 mm |
| Grating Density | 1600 lines/mm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5 nm (standard at 2 nm) |
| Wavelength Accuracy | ±0.3 nm (typical ≤±0.2 nm) |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.02% T (at 220 nm, NaI |
| Photometric Range | 0.0–200.0% T, –0.301–4.000 A, 0.000–9999 C |
| Photometric Accuracy | ±0.2% T, ±0.0009 A (0–0.5 A), ±0.002 A (0.5–1 A) |
| Photometric Repeatability | ≤0.08% T, ≤0.0004 A (0–0.5 A), ≤0.008 A (0.5–1 A) |
| Baseline Flatness | ±0.0006 A |
| Noise | 0.03% T / 0.00015 A |
| Baseline Drift | 0.0003 A/h (after 2 h warm-up at 250 nm & 500 nm) |
| Light Source | Imported deuterium lamp + tungsten-halogen lamp, auto-switching at 340 nm (adjustable) |
| Detector | Imported photodiode array or silicon photodetector |
| Display | 10.1″ capacitive touch screen, Android 10 OS, 262k-color, 178° viewing angle |
| Data Storage | 8 GB internal memory |
| Connectivity | USB port, Wi-Fi, Bluetooth |
| Software Options | UVWin8 PC software (optional), GLP-compliant data logging and audit trail support |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 7800–350 cm⁻¹ |
| Resolution | <1.0 cm⁻¹ |
| Scan Speed | 4 cm⁻¹ |
| Signal-to-Noise Ratio | 15,000:1 / 30,000:1 (at 4 cm⁻¹, 1 min scan) |
| Beamsplitter | KBr substrate with Ge coating |
| Detector | Imported high-sensitivity deuterated L-alanine triglycine sulfate (DLaTGS) |
| Source | Imported long-life, air-cooled high-intensity IR source |
| Interferometer | Sealed 30°-incidence Michelson interferometer with built-in auto-alignment optics |
| A/D Conversion | 24-bit, 500 kHz |
| Communication Interface | USB 2.0 (backward compatible with USB 3.0) |
| Dimensions | 450 × 350 × 235 mm (L×W×H) |
| Weight | 14 kg |
| Operating Temperature | 15–35 °C |
| Power Consumption | <30 W |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GDA 150 HR |
| Price Range | USD 210,000 – 280,000 |
| Brand | GDANA |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | SPEAR 500 |
| Pricing | Upon Request |
| Brand | Chemlab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GenesisRaman |
| Price Range | USD 630,000 – 775,000 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Resolution | ≤2 cm⁻¹ |
| Spatial Resolution | Lateral 1 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ≤±0.2 cm⁻¹ |
| Brand | Gentec-EO |
|---|---|
| Origin | Canada |
| Product Type | Laser Beam Diagnostic System |
| Model | BeamWatch Active |
| Wavelength Range | 190 nm – 11 µm |
| Measurement Principle | Non-contact, real-time camera-based beam profiling with ISO 11146-compliant M² calculation |
| Compliance | ISO 11146-1:2005, ISO 11146-2:2005, ANSI Z136.1 |
| Software | BeamWatch Studio v4.x (FDA 21 CFR Part 11 compliant audit trail, GLP/GMP-ready export) |
| Detector Type | High-dynamic-range CMOS sensor array with motorized neutral density filter wheel |
| Spatial Resolution | ≤ 5 µm (system-limited) |
| Frame Rate | Up to 60 Hz at full resolution |
| Data Output | ASCII, CSV, HDF5, TIFF, PNG |
| Interface | GigE Vision, USB 3.2 Gen 1 |
| Brand | GIT (Gas Imaging Technology) |
|---|---|
| Origin | USA |
| Model | Sherlock SF6 |
| Detector Type | Photomultiplier Tube (PMT) |
| Spectral Range | 10.5 µm |
| Spectral Bandwidth | 10.5 µm |
| Wavelength Accuracy | ±1 mL/min (7 lbs/year SF₆ detection limit) |
| Wavelength Repeatability | ±1 mL/min (7 lbs/year SF₆ detection limit) |
| Spatial Resolution | 320 × 240 pixels |
| Instantaneous Field of View (IFOV) | 0.4 mrad |
| Full Field of View (FOV) | 7.3° × 5.5° |
| Focal Length | 70 mm @ 8 µm |
| Aperture | f/2.38 @ 8 µm |
| NETD | <35 mK |
| Weight (w/o battery) | 12 lb (5.4 kg) |
| Weight (with battery) | 17 lb (7.7 kg) |
| Dimensions | 12″ L × 6″ W × 8″ H (305 × 152 × 203 mm) |
| Power Supply | 12 V rechargeable battery or AC adapter |
| Brand | GIT (Gas Imaging Technology) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Sherlock VOC |
| Price | Upon Request |
| Weight (without battery) | 6.8 kg (15 lbs) |
| Weight (with battery) | 8.6 kg (19 lbs) |
| Dimensions | 30.5 × 17.8 × 20.3 cm |
| Power Supply | 12 V rechargeable battery or AC adapter |
| Spectral Range | Pre-tuned to hydrocarbon absorption bands (MWIR, ~3 µm) |
| Aperture | f/2.5 at 3 µm |
| Focal Length | 75 mm at 3 µm |
| Instantaneous Field of View (IFOV) | 0.4 mrad |
| Total Field of View (FOV) | 7.3° × 5.5° |
| Spatial Resolution | 320 × 240 pixels |
| Minimum Detectable Leak Rate | 1 mL/min (≈1 g/hr for methane-equivalent VOCs) |
| Display | 640 × 480 LCD |
| Video Capture | Internal 14-bit frame grabber |
| Interfaces | Ethernet, RS-232, NTSC, S-Video, USB |
| Software | HyPAT™ for spectral analysis and quantitative gas mapping |