Spectroscopy Instruments
Filter
Showing 691–720 of 1322 results
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MD100 |
| Pricing | Available Upon Request |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 2060NIR |
| Instrument Type | Online NIR Spectrometer |
| Application Scope | General-purpose (Academic & Research Laboratories) |
| Operating Principle | Grating-based, Non-scanning Array Detector |
| Wavelength Range | 1000–2250 nm |
| Scan Rate | 5000 spectra/s |
| Spectral Sampling Interval | 0.5 nm |
| Measurement Mode | Real-time In-line Analysis |
| Chemometrics Software | IMPACT / OMNIS |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Country of Origin | Imported (Switzerland) |
| Model | 2060 Raman |
| Laser Wavelength | 785 nm |
| Number of Simultaneous Sampling Channels | Up to 5 |
| Spectral Resolution | High-throughput optimized |
| Environmental Rating | NEMA 4X / IP66 |
| Calibration | Integrated reference channel with automated Raman shift correction |
| Analysis Time per Sample | ≤10 seconds |
| Communication Protocols | 4–20 mA, OPC UA, Modbus TCP, Profibus DP |
| Software Platform | Vision and IMPACT |
| Fluorescence Suppression | Advanced real-time algorithm |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Country of Origin | Imported |
| Model | DS2500 L |
| Instrument Type | Laboratory NIR Spectrometer |
| Principle | Grating-scanning monochromator |
| Wavelength Range | 400–2500 nm |
| Scan Speed | 32 scans per second |
| Data Sampling Interval | 0.5 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | Vision Air |
| Brand | Metrohm |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DS 2500 |
| Instrument Type | Laboratory |
| Principle | Grating Scanning |
| Wavelength Range | 400–2500 nm |
| Scan Speed | 2 scans/sec |
| Data Sampling Interval | 0.5 nm |
| Measurement Modes | Diffuse Reflectance / Transflectance |
| Chemometrics Software | Vision |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm |
| Product Type | Portable/Handheld Raman Spectrometer |
| Model | i-Raman NxG |
| Laser Options | 532 nm, 785 nm, or 1064 nm |
| Dual-Laser Configuration Available (i-Raman Duo) | 1064 nm + 860 nm |
| Software Platform | SpecSuite™ |
| Sample Interface | Fiber-optic probe compatible with vials, cuvettes, immersion probes, and fixed-stage holders |
| Compliance | Designed for GLP/GMP-aligned workflows, supports audit-trail-enabled data management per FDA 21 CFR Part 11 requirements |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm |
| Product Type | Portable / Handheld Raman Spectrometer |
| Model | i-Raman Plus |
| Spectral Range | 175–4000 cm⁻¹ |
| Spectral Resolution | 3.0 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Low-Wavenumber Cutoff | 65 cm⁻¹ |
| Spectral Reproducibility | <0.5 cm⁻¹ |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | B&W Tek (distributed by Metrohm) |
| Instrument Type | Portable/HANDHELD Raman Spectrometer |
| Spectral Range | 150–3400 cm⁻¹ |
| Spectral Resolution | < 8.0 cm⁻¹ @ 912 nm |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 150 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.15 cm⁻¹ |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Product Type | Handheld Raman Spectrometer |
| Model | Mira P |
| Spectral Range | 400–2300 cm⁻¹ |
| Spectral Resolution | 12–14 cm⁻¹ (FWHM) |
| Minimum Wavenumber | 400 cm⁻¹ |
| Spectral Reproducibility | ≤0.15 cm⁻¹ |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Instrument Type | Handheld Raman Spectrometer |
| Model | MIRA XTR |
| Spectral Range | 400–2300 cm⁻¹ |
| Spectral Resolution | 10 cm⁻¹ |
| Laser Wavelength | 785 nm |
| Database Size | >20,000 reference spectra |
| Standoff Distance | Up to 2 m |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 (software-enabled), ISO/IEC 17025-compatible workflows |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | OMNIS NIR |
| Instrument Type | Benchtop Laboratory Spectrometer |
| Principle | Fixed-grating array-detector non-scanning design |
| Wavelength Range | 1000–2250 nm |
| Scan Speed | 300 spectra/s |
| Data Sampling Interval | 0.5 nm |
| Sample Modes | Diffuse Reflectance / Transmission / Transflection |
| Chemometrics Software | OMNIS Platform |
| Brand | Metrohm |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PRO Online NIR |
| Instrument Type | Online Process Analyzer |
| Application Field | Petrochemical Industry |
| Operating Principle | Fixed Grating with Diode Array Detector (Non-Scanning) |
| Wavelength Range | 1100–1650 nm (Reflectance), 850–1050 nm (Transmittance) |
| Scan Speed | 0.5 s per spectrum |
| Spectral Sampling Interval | 0.5 nm |
| Sample Interface Modes | Diffuse Reflectance (Solids), Transflectance (Liquids), Transmission (Liquids) |
| Chemometrics Software | Vision with ISIcal™ |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Product Type | Portable/Handheld Raman Spectrometer |
| Model | TacticID-1064 |
| Spectral Range | 176–2900 cm⁻¹ |
| Spectral Resolution | 9 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 176 cm⁻¹ |
| Spectral Repeatability | ±1 cm⁻¹ |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Product Type | Portable/Handheld Raman Spectrometer |
| Model | TacticID-N |
| Spectral Range | 176 – 2900 cm⁻¹ |
| Spectral Resolution | ~9 cm⁻¹ at 912 nm |
| Compliance | Designed for forensic field use in accordance with ISO/IEC 17025–aligned operational protocols |
| Software | Embedded spectral library with remote update capability |
| Detection Technology | Conventional Raman + optional SERS (via TacPac™ accessory) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Easy UV |
| Price | Upon Request |
| Wavelength Range | 190–1000 nm |
| Photometric Accuracy (K₂Cr₂O₇) | ±0.005 A |
| Wavelength Accuracy | ±1.5 nm |
| Stray Light (KCl, 198 nm) | ≤2.5% |
| Light Source | Xenon Flash Lamp |
| Optical Path Lengths | 10 mm, 16 mm, 20 mm, 30 mm, 40 mm, 50 mm (1 inch equivalent) |
| Display | 4.3-inch capacitive touchscreen |
| Dimensions (H×W×D) | 176 × 201 × 362 mm |
| Weight | 4.25 kg |
| Max. Stored Methods | 80 |
| User-Defined Quick Keys | 10 |
| Supported Languages | English, Spanish, French, German, Italian, Portuguese, Polish, Japanese, Korean, Chinese, Thai, Indonesian |
| Colorimetric Standards | CIELAB, APHA, Gardner (30 pre-programmed color scales) |
| Compliance | Designed to support pharmacopeial workflows (USP <85>, EP 2.2.25, JP 2.04) |
| Connectivity | USB port for printer (USB-P25), barcode scanner (SQKitReader™), and peripheral storage |
| Sample Handling | Fixed cuvette holder (no autosampler or cuvette changer) |
| Application Scope | Quantitative analysis, spectral scanning, water quality testing (Spectroquant® integration), color measurement |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy VIS |
| Wavelength Range | 330–1000 nm |
| Photometric Accuracy (K₂Cr₂O₇) | ±0.005 A |
| Wavelength Accuracy | ±1.5 nm |
| Light Source | Tungsten Halogen Lamp |
| Optical Path Options | 10, 16, 20, 30, 40, 50 mm (1 inch) |
| Display | 4.3-inch capacitive touchscreen |
| Dimensions (H × W × D) | 176 × 201 × 362 mm |
| Weight | 4.25 kg |
| User-Defined Methods | Up to 80 |
| Quick Access Keys per User | 10 |
| Supported Languages | English, Spanish, French, German, Italian, Portuguese, Polish, Japanese, Korean, Chinese, Thai, Indonesian |
| Barcode Reader Compatibility | SQKitReader™ handheld scanner (optional) |
| Printer Interface | USB-P25 |
| USB Host Port | Yes |
| Cuvette Changer | Not integrated |
| Pharmacopeia Compliance | Not specified |
| Colorimetric Standards | 25 pre-programmed methods (CIELAB, APHA, Gardner, etc.) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | ReactIR 701L |
| Instrument Type | In-line / Flow-through Process Spectrometer |
| FTIR Architecture | Michelson Interferometer-Based |
| Wavenumber Range | 4000–650 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Scan Rate | 7 scans per second |
| Signal-to-Noise Ratio (SNR) | 2000:1 |
| Detector | High-Sensitivity, Liquid-Nitrogen-Cooled MCT (Mercury Cadmium Telluride) |
| Probe Compatibility | Fiber-Optic ATR, Transmission, and Reflectance Probes |
| Operating Environment | Lab-scale reactors (glass, stainless steel), flow cells, and microreactors |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | ReactIR 702L |
| Instrument Type | In-line / Flow-through Process Analytical Technology (PAT) System |
| Spectral Range | 4000–800 cm⁻¹ |
| Detector | Solid-State Cooled MCT (Mercury Cadmium Telluride) |
| Optical Interface | Fiber-Optic Probe Coupling (No Purge Gas Required) |
| Configuration | Benchtop, Stackable, Vent-Hood Compatible |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | ReactIR™ 45m, ReactIR™ 45p |
| Instrument Type | In-situ, Real-time Online FTIR Spectrometer |
| Wavenumber Range | 4000–650 cm⁻¹ |
| Resolution | 4 cm⁻¹ |
| Signal-to-Noise Ratio | 2000:1 |
| Scan Speed | Not specified (typical for high-stability process-grade FTIR) |
| Probe Materials | Diamond, Silicon, Zirconia ATR crystals |
| Wetted Materials | Hastelloy®, Gold |
| Temperature Range | −80 °C to 200 °C (optional up to 300 °C) |
| Pressure Rating | Vacuum to 7 bar (optional up to 350 bar) |
| Probe Diameters | 6.35 mm, 9.5 mm, 16 mm, 25.4 mm |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ReactRaman 802L |
| Instrument Type | Fourier Transform Raman Spectrometer |
| Spectral Range | 150–3400 cm⁻¹ |
| Spectral Resolution | 6 cm⁻¹ |
| Spatial Resolution | 2 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Repeatability | ±0.2 cm⁻¹ |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV5, UV7 |
| Optical Design | Single-beam with pulsed xenon lamp |
| Detector | 2048-pixel CCD array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm (UV5), ±0.8 nm (UV7) |
| Stray Light | <0.01% T at 198 nm (KCl) |
| Scan Speed | Full spectrum in ≤1 s |
| Photometric Accuracy | ±0.01 A (K₂Cr₂O₇) |
| Wavelength Resolution (toluene in n-hexane) | >1.5 nm (UV5), >1.9 nm (UV7) |
| Display | 7″ QVGA color TFT touchscreen (400 × 800 px) |
| Dimensions (L×W×H, without controller) | 208 × 255 × 228 mm |
| Weight (with controller) | 6.4 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV5 / UV7 / UV5Bio |
| Detector Type | CCD (Charge-Coupled Device) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.9 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | <0.03% T (at 220 nm, KI solution) |
| Automation Level | Automatic Wavelength Selection |
| Lamp Type | Xenon Flash Lamp |
| Warm-up Time | None |
| Dimensions | Compact footprint (~A4 size) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV5Bio / UV5Nano |
| Optical Design | Dual-wavelength |
| Detector | CCD array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Stray Light (at 198 nm, KCl) | >2.0 A |
| Scan Time (full spectrum) | 1 s |
| Automation | Automatic wavelength selection, integrated cuvette changer, FillPalMini peristaltic pump |
| Compliance | ASTM E275, ISO 6425, USP <857>, FDA 21 CFR Part 11 ready (via LabX®) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | UV5Nano |
| Detector Type | CCD (Charge-Coupled Device) |
| Wavelength Range | 190 nm – 1,100 nm |
| Wavelength Automation | Automatic |
| Spectral Bandwidth | 1.5 nm |
| Wavelength Accuracy | ±0.9 nm |
| Stray Light | <0.03% T (at 220 nm, KI solution) |
| Brand | Micheem / BEIJING MICHEM TECHNOLOGY LTD. |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | M4000 |
| Pricing | Upon Request |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MicroHSImager |
| Pricing | Available Upon Request |
| Brand | Microlink / BEIJING MICHEM TECHNOLOGY LTD. |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector | Scientific-grade CMOS array (replacing legacy CCD) |
| Focal Length | 1000 mm |
| Grating Density | 3600 lines/mm |
| Wavelength Range | 140 nm – 680 nm |
| Number of Simultaneous Detection Channels | 96 |
| Optical System | Dual-chamber vacuum-UV + UV-Vis configuration |
| Structural Material | Stress-relieved die-cast aluminum optical chamber (4-stage annealing) |
| Thermal Management | Active chamber temperature stabilization with laminar purge gas flow |
| Spectral Optimization | RTMC (Real-Time Multi-Channel) calibration and drift compensation algorithm |
| Compliance | Designed to support ISO/IEC 17025 workflows, ASTM E415, ASTM E1086, ASTM E3061, and GB/T 4336–2016 methodologies |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | microPHAZIR AS |
| Price Range | USD 70,000–140,000 (FOB) |
| Principle | Portable, Non-Contact Reflectance NIR Spectroscopy |
| Measurement Time | <10 s |
| Sampling Mode | Non-Contact Diffuse Reflectance |
| Weight | 1.25 kg |
| Housing | Ruggedized Dust-Resistant Polymer Enclosure |
| Light Source | Tungsten-Halogen Lamp (Class 1 LED-equivalent Safety) |
| Data Interface | Internal Flash Memory + USB 2.0 Host Interface |
| Operating Temperature | 5–40 °C (non-condensing) |
| Power Supply | Dual Hot-Swappable Li-ion Batteries (4.5 h typical runtime) |
| Optional Accessories | AC Battery Charger, Carrying Case with Belt Clip |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | QuickDrop |
| Wavelength Accuracy | ±2 nm |
| Wavelength Range | 190–1100 nm |
| Cuvette Compatibility | Yes |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MS-96 |
| Price Range | USD 42,000 – 70,000 |
