Spectroscopy Instruments
Filter
Showing 781–810 of 1322 results
| Brand | PerkinElmer |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LAMBDA 750 |
| Instrument Architecture | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Scanning | Motorized Automatic |
| Wavelength Range | 175 nm to 3300 nm |
| Brand | PerkinElmer |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LAMBDA 850+ |
| Instrument Architecture | Double-Beam |
| Detector Type | R6872 Photomultiplier Tube (PMT) |
| Automation Level | Motorized Wavelength Scanning |
| Wavelength Range | 175–900 nm |
| Wavelength Accuracy | ±0.025 nm |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Imported |
| Model | Lambda 950 |
| Optical Design | Double-Beam, Dual-Monochromator |
| Detector | R6872 Photomultiplier Tube (PMT) |
| Wavelength Range | 175–3300 nm (185 nm minimum under nitrogen purge) |
| Spectral Bandwidth | Variable (0.01–8 nm), software-selectable |
| Wavelength Accuracy | ±0.08 nm (UV/Vis), ±0.2 nm (NIR) |
| Stray Light | <0.00008% T at 220 nm (NaI), <0.0001% T at 340 nm (NaNO₂) |
| Photometric Linearity | Up to 8.0 A (absorbance) |
| Baseline Flatness | ±0.0004 A (190–3300 nm, 1 nm SBW) |
| Automation | Fully motorized optics, auto-lamp switching (D₂ & W/Tungsten), auto-correcting chopper, PC-controlled |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LS-55 |
| Pricing | Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame AAS |
| Model | PinAAcle 500 |
| Monochromator | Echelle Grating |
| Optical System | Dual-Beam |
| Detector | Solid-State CCD Array |
| Background Correction | Deuterium Lamp |
| Flame System | FAST Flame Automated Burner Head Positioning and Gas Control |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer | PerkinElmer |
| Country of Origin | Imported |
| Model | PinAAcle 900 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Solid-State Detector |
| Background Correction | D₂ Lamp + Longitudinal Zeeman |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | PinAAcle D900 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp Correction |
| Safety Interlocks | 7 Integrated Sensors |
| Automation | Dual-Mode Autosampler Compatible with Both Flame and GF Modes |
| Software Interface | Touchscreen-Controlled Method Wizard with Real-Time Camera Integration |
| Reporting | Customizable PDF Reports Including Calibration Curves and Sample Data |
| Brand | PerkinElmer |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | PinAAcle™ 950D |
| Pricing | Available upon request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Spectrum 3 |
| Instrument Type | Laboratory FT-IR Spectrometer |
| Instrument Category | Fourier Transform Type |
| Wavenumber Range | Not Specified |
| Resolution | Not Specified |
| Scan Speed | Up to 100 scans/sec |
| Signal-to-Noise Ratio | Not Specified |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Spectrum Two |
| Instrument Type | Benchtop Laboratory FTIR Spectrometer |
| Instrument Category | Fourier Transform Infrared (FTIR) Spectrometer |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Spectrum Two N |
| Instrument Type | Laboratory Benchtop |
| Operating Principle | Fourier Transform (FT-NIR) |
| Wavelength Range | 680–4800 nm |
| Data Sampling Interval | 1/4 resolution or user-defined |
| Sample Introduction | Direct sampling (reflectance, transmission, remote probe) |
| Software | Spectrum 10™ Suite (including Spectrum 10 ES, Spectrum Touch™, Spectrum Adulterant Screen, Spectrum Quant™ Advanced Algorithms Pack, Spectrum AssureID) |
| Brand | Perten |
|---|---|
| Origin | United Kingdom |
| Model | Spectrum Two N |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform (Interferometric) |
| Wavelength Range | 680–4800 nm |
| Data Sampling Interval | 1/4 resolution or user-defined |
| Sample Introduction | Direct sampling |
| Software | Spectrum 10™ Suite (including Spectrum 10 ES, Spectrum Touch™, Spectrum Adulterant Screen, Spectrum Quant™ Advanced Algorithms Pack, Spectrum AssureID) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Spotlight 400/400N |
| Instrument Type | Laboratory FT-IR Imaging System |
| Detector Architecture | Patented Linear Array MCT Detector |
| Spectral Range | Up to 720 cm⁻¹ (Mid-IR) and Extended NIR Capability |
| Spatial Resolution | 1.56 µm (ATR mode), 6.25 µm / 25 µm / 50 µm (Transmission/Reflection modes) |
| Imaging Speed | Up to 170 spectra/sec |
| Scan Modes | Single-region, Multi-region, Unattended Overnight Acquisition |
| Sample Stage | Motorized, High-Precision, Repeatability ±0.001% |
| Optional Accessories | Imaging ATR, Large-Area Sample Stage |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal |
| Wavelength Accuracy | ±0.15 nm |
| Baseline Stability | ±0.002 A/30 min (static) |
| RSD (Repeatability) | ≤0.6% for Cu (air-acetylene), ≤1.0% for Cu (LPG-air) and Ba (N₂O-acetylene), ≤2.0% for Cu and Cd (graphite furnace) |
| Characteristic Concentration | Cu < 0.02 µg/mL/1% (air-acetylene & LPG-air), Ba < 0.15 µg/mL/1% (N₂O-acetylene) |
| Detection Limit | Cu < 0.004 µg/mL (flame), Cd < 0.4 pg (graphite furnace) |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Cu Sensitivity | >0.3 A at 5 ppm |
| Precision (RSD) | <0.4% |
| Cu Detection Limit | <0.004 µg/mL |
| Baseline Drift | <0.0008 A/30 min |
| Peak-to-Peak Baseline Noise | <0.0008 A/30 min |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | CPG2/CPG2S |
| Instrument Type | Graphite Furnace Atomic Absorption Spectrometer (GFAAS) |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Solid-State Detector |
| Background Correction | Automatic Deuterium/Hollow Cathode Lamp Dual-Beam Background Correction |
| Detection Limits | Pb: 0.02 mg/kg, Cd: 0.002 mg/kg |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Persee General Instrument Co., Ltd. |
| Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Gravity-driven |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn |
| Relative Standard Deviation (RSD) | <1% (for As, Sb, Bi, Hg) |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | ≤0.01 ng/mL (As, Sb, Bi) |
| Photomultiplier Tube | Hamamatsu R7154, spectral response range 160–320 nm |
| Atomizer Temperature Control Range | Ambient to 400 °C |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PF5 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Liquid Discharge | Gravity-driven (Static) |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn |
| Relative Standard Deviation (RSD) | <1% for representative elements (As, Sb, Bi, Hg) |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | ≤0.01 ng/mL for As, Sb, Bi |
| Photomultiplier Tube (PMT) | R7154, spectral response range 160–320 nm |
| Atomizer Temperature Control Range | Ambient to 400 °C |
| [Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction Mode | Dual Sequential Injection Pump |
| Waste Liquid Disposal | Gravity-driven (Static) |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn |
| Relative Standard Deviation (RSD) | <1% for As, Sb, Bi, Hg |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | ≤0.01 ng/mL for As, Sb, Bi |
| Photomultiplier Tube (PMT) | Hamamatsu R7154, spectral response range 160–320 nm |
| Atomizer Temperature Control Range | Ambient to 400 °C] |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SA7/5 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Pneumatic Flow Injection System (replaces peristaltic pump) |
| Waste Disposal | Gravity-driven dual-port drainage |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Hg, Se, Sb |
| RSD | ≤1.0% (at 0.01 ng/mL for As, Sb, Bi |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As/Sb/Bi ≤ 0.01 ng/mL |
| PMT Spectral Range | Hamamatsu R7154, 160–320 nm |
| Atomizer Temperature Control | Ambient to 100 °C, adjustable in 0.1 °C increments |
| UV Digestion Cell | Quartz plate-type flow-through reactor with high UV photon utilization |
| Dual-Channel Waste Separation | Organic and inorganic waste streams isolated via dedicated tubing paths |
| Certified Performance Data Source | Public Service Platform for Enterprise Standard Information (China) |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Solid Sample Testing Solution |
| Price Range | USD 14,000 – 21,000 (FOB) |
| Optical Architecture | Dual-Wavelength Configuration |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Scanning Mode | Automatic |
| Stray Light | < 0.0004% (4 × 10⁻⁴ %) |
| Compatible Accessories | 150 mm Integrating Sphere (Standard), 60 mm Integrating Sphere (Standard), Eyewear-Specific Measurement Fixture |
| Sample Types | Opaque/Translucent Solids, Powders, Turbid Liquids |
| Measurement Modes | Diffuse Reflectance, Specular Reflectance, Total Transmittance, Diffuse Transmittance |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | T400 / T500 |
| Price Range | USD 1,400 – 4,200 |
| Optical Design | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 325–1100 nm (T400) / 190–1100 nm (T500) |
| Wavelength Accuracy | ±0.2 nm (T400) / ±0.1 nm (T500) |
| Wavelength Repeatability | ≤0.4 nm (T400) / ≤0.2 nm (T500) |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.05%T at 360 nm (T400) / ≤0.05%T at 220 nm (T500) |
| Wavelength Scanning Speed | 2500 nm/min |
| Wavelength Setting Speed | 7000 nm/min |
| Dimensions (W×D×H) | 470 × 400 × 210 mm |
| Weight | 11 kg |
| Display | 7-inch Color Touchscreen |
| Data Export | USB Flash Drive Support |
| Sample Compartment | Open-Design with Integrated Cuvette Storage Rack |
| Software Interface | PC-Connectable Workstation with GLP Compliance Features |
| Firmware Upgradability | Over-the-Air (OTA) for Application Module Expansion (e.g., Protein Quantitation, Pesticide Residue Analysis, Water Quality Testing) |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Domestic |
| Model | T6 Series |
| Price Range | USD 1,400–2,800 |
| Optical Design | Pseudo-Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Positioning |
| Spectral Bandwidth | 2.0 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | 0.05% T at 220 nm |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | T700/T600 |
| Optical Design | Dual-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 5 nm / 2 nm / 1 nm / 0.5 nm / 0.2 nm (selectable) |
| Stray Light | ≤0.01% T at 220 nm |
| Absorbance Range | –4 to +4 Abs |
| Scan Speed | Up to 30,000 nm/min |
| Interface | Ethernet port |
| Display | 9.7-inch capacitive touchscreen |
| Compliance | Meets JJG 178–2015 (Chinese National Verification Regulation for UV-Vis Spectrophotometers, Class I accuracy) |
| [Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 185 nm – 900 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm) |
| Wavelength Repeatability | ≤0.05 nm (at D₂ line, 656.1 nm) |
| Spectral Bandwidth | Continuously Adjustable from 0.1 nm to 5.0 nm |
| Stray Light | ≤0.0001% T (NaI, 220 nm) |
| Photometric Range | –6 Abs to +6 Abs |
| Baseline Flatness | ±0.0008 Abs |
| Absorbance Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.3% T (>1.0 Abs) |
| Absorbance Repeatability | ≤0.001 Abs (0–0.5 Abs), ≤0.002 Abs (0.5–1.0 Abs), ≤0.1% T (>1.0 Abs) |
| Drift | ≤0.1% T/h |
| Optical System | Hybrid Czerny-Turner Dual-Monochromator with High-Reflectivity Coated Optics |
| Light Sources | Integrated Deuterium Lamp, Tungsten-Halogen Lamp, and Mercury Calibration Lamp (Auto-Switching)] |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal Method |
| Wavelength Accuracy | ±0.25 nm |
| Spectral Bandwidth | ≤0.15 nm |
| Detection Limit (Flame, Cu) | 0.006 µg/mL |
| Detection Limit (GFAAS, Cd) | 1.0 pg |
| Characteristic Concentration (Cu) | <0.04 µg/mL per 1% absorption |
| Baseline Stability (Static) | ±0.004 A/30 min |
| RSD (Flame Cu) | <1% |
| RSD (GFAAS Cu) | <3.0% |
| RSD (GFAAS Cd) | <4.0% |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Persee General Instrument Co., Ltd. |
| Model | TAS-990 |
| Instrument Type | Dual-mode (Flame + Electrothermal Graphite Furnace) |
| Monochromator | Concave Grating |
| Optical System | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-reversal Method |
| Wavelength Accuracy | ±0.25 nm |
| Baseline Stability (Static) | ±0.004 A / 30 min |
| RSD (Repeatability) | ≤1.0% (Flame, Cu), ≤3.0% (GFAAS, Cu) |
| Characteristic Concentration (Cu) | <0.04 µg/mL per 1% absorption |
| Detection Limit (Flame, Cu) | <0.006 µg/mL |
| Detection Limit (GFAAS, Cd) | <1.0 pg |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Architecture | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Motorized Automatic Wavelength Drive |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 5.0 nm (TU-1810S models, variable slit) |
| Wavelength Accuracy | ±0.3 nm (with automatic on-boot wavelength calibration) |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.02% T at 220 nm (using NaI solution), ≤0.05% T at 360 nm (using NaNO₂ solution) |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | UV-Vis Automated Liquid Sampling Solution |
| Price Range | USD 14,000 – 21,000 |
| Optical Design | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.8 nm (typical) |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | <0.05% T at 220 nm and 360 nm |
| Automation Level | Fully Automated Wavelength Scanning & Sample Handling |
| Sample Capacity | Three Independent Sample Carriers Supporting Configurable Racks (50 mL × 10 wells, 25 mL × 18 wells, or 20 mL × 18 wells) |
| Positioning System | Programmable 3-Axis Robotic Arm with Sub-millimeter Repeatability |
| Cleaning Mechanism | Peristaltic Pump–Driven Dynamic Immersion Rinse with Solvent Exchange Protocol |
| Brand | Perser-Tech |
|---|---|
| Origin | Fujian, China |
| Model | PERS-F700 |
| Instrument Type | Handheld Raman Spectrometer |
| Spectral Range | 175–3500 cm⁻¹ |
| Spectral Resolution | ≤7 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 175 cm⁻¹ |
| Spectral Reproducibility | ±1 cm⁻¹ |
| Operating Temperature | 5–45 °C |
| Relative Humidity | <90% RH |
| Excitation Wavelength | 785 nm (standard, fixed-frequency diode laser) |
| Integration Time & Laser Power | Continuously Adjustable |
| Sample Interface | Non-contact, focus-adjustable collimated beam |