Spectroscopy Instruments
Filter
Showing 811–840 of 1322 results
| Brand | Perten |
|---|---|
| Origin | USA |
| Model | DA 7350 |
| Instrument Type | Online |
| Wavelength Range | 950–1650 nm |
| Scan Speed | >30 sub-spectra per second |
| Data Sampling Interval | User-Configurable |
| Measurement Modes | Near-Infrared Reflectance & Digital Color Imaging |
| Chemometrics Software | PerCAL |
| Compliance | Designed for GLP/GMP environments |
| Communication Protocols | OPC UA, PROFINET, Modbus TCP, Fieldbus |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | DA7250 |
| Instrument Type | Laboratory |
| Principle | Grating-based non-scanning diode array spectrometry |
| Wavelength Range | 950–1650 nm |
| Scan Speed | 100 spectra/sec |
| Data Sampling Interval | 0.008 s |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | Unscrambler |
| Detector | Thermoelectrically Cooled InGaAs Diode Array |
| Optical Resolution | Adjustable from 0.1 nm to 10 nm |
| Spectral Bandwidth | ~7 nm |
| Wavelength Accuracy | <0.05 nm |
| Wavelength Repeatability | <0.02 nm (per measurement), <0.2 nm/year |
| Absorbance Range | 0–2.5 AU |
| Noise Level | <20 µA (10 s continuous acquisition) |
| Light Source Lifetime | >10,000 h |
| Operating Temperature | 0–40 °C |
| IP Rating | IP65 |
| Sample Weight Capacity | 0.5–300 g (solids), 2–100 mL (liquids) |
| Standard Sample Area | 154 cm² (large cup), 44 cm² (small cup) |
| Analysis Time | ≤6 s per sample |
| Measurement Geometry | Non-contact rotating scan |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | DA7430M |
| Instrument Type | Online |
| Principle | Grating Scanning NIR Spectrometer |
| Wavelength Range | 950–1650 nm |
| Scan Speed | 30 subspectra/second |
| Sampling Interval | User-Configurable |
| Measurement Mode | Diffuse Reflectance / Transflectance |
| Chemometrics Software | Unscrambler X, Percal |
| Ingress Protection Rating | IP67 |
| Optical Spot Diameter | >10 cm |
| Light Source | Long-Life Xenon Lamp |
| Mounting Compatibility | Chutes, Screw Conveyors, Belt Conveyors, Mixers, Scrapers |
| Communication Protocols | OPC UA, Ethernet, Modbus TCP/IP, 4–20 mA Analog Output, Profibus |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | DA7440 |
| Instrument Type | Online |
| Principle | Grating Scanning |
| Wavelength Range | 950–1650 nm |
| Scan Speed | 30 subspectra/sec |
| Data Sampling Interval | User-Configurable |
| Measurement Mode | Diffuse Reflectance / Transflectance |
| Chemometrics Software | Unscrambler X, Percal |
| Brand | Perten |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FT 9700 |
| Instrument Type | Laboratory |
| Application Domain | General-purpose (Academic & Research) |
| Operating Principle | Fourier Transform (FT) |
| Wavelength Range | 700–2500 nm (14,300–4000 cm⁻¹) |
| Scan Speed | <1 minute per spectrum |
| Data Sampling Interval | Adjustable |
| Sample Measurement Modes | Diffuse Reflectance and Transflectance |
| Chemometrics Software | PerCal |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | IM 8800 |
| Instrument Type | Portable |
| Application Field | Cereals & Oilseeds |
| Measurement Principle | Grating-based diode array (non-scanning) |
| Wavelength Range | 850–1050 nm |
| Scan Time | 20 seconds |
| Data Sampling Interval | 5 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | Unscrambler® |
| GPS Integration | Yes |
| Power Supply | 12 V DC or internal rechargeable battery (2 h runtime) |
| Compliance | AACC Method 39-25 |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | IM9520 |
| Instrument Type | Benchtop Laboratory NIR Spectrometer |
| Application Domain | Cereal Grains & Milled Flour |
| Optical Principle | Grating Scanning Transmission NIR |
| Wavelength Range | 570–1100 nm |
| Scan Speed | 10 scans/minute |
| Data Acquisition Interval | 6 seconds per measurement |
| Sample Mode | Transmission |
| Chemometrics Software | Unscrambler® |
| Calibration Framework | NIST-traceable wavelength calibration |
| Compliance | ASTM D6341 (NIR for cereal analysis), ISO 12099:2017 (Animal feeding stuffs — General guidelines for the determination of chemical constituents by NIR spectroscopy), GLP-compliant data audit trail support via NetPlus™ |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | IM 9500plus |
| Instrument Type | Laboratory NIR Spectrometer |
| Application Domain | Cereal & Oilseed Analysis |
| Principle | Grating Scanning Transmission NIR |
| Wavelength Range | 570–1100 nm |
| Scan Speed | 10 scans/min |
| Data Acquisition Interval | 6 s/scan |
| Measurement Mode | Transmission |
| Chemometrics Software | Unscrambler X |
| Brand | Auniontech (HaoLiang) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PR-1050 SpectraScan |
| Pricing | Available Upon Request |
| Brand | PHXTEC |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AA68 A |
| Instrument Type | Flame AAS |
| Monochromator Element | Plane Grating |
| Optical System | Single-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal Method |
| Spectral Resolution | 0.1 nm |
| Sensitivity | >0.3 A (for Cu 0.5 µg/mL) |
| Repeatability (RSD) | ≤0.5% |
| Detection Limit | 0.003 µg/mL (for Cu) |
| Baseline Stability | ≤0.002 A / 30 min |
| Brand | PhysTech |
|---|---|
| Origin | Germany |
| Model | FT1030 |
| Instrument Type | Deep-Level Transient Spectroscopy System |
| Operating Modes | C-DLTS, CC-DLTS, I-DLTS, DD-DLTS, Zerbst-DLTS, O-DLTS, FET-Analysis, MOS-Analysis, ITS, PITS, TSC/TSCAP, DLOS, C/V(T), I/V(T), Richardson Plot, Capture Cross-Section Analysis |
| Key Software Features | 28 simultaneous correlation functions per temperature scan, Fourier-DLTS (F-DLTS), Laplace-DLTS, multi-exponential transient fitting, isothermal transient spectroscopy (ITS), signal overlap deconvolution (temperature-scan & isothermal), automatic contact check, real-time capacitance compensation, three-terminal FET current transient acquisition |
| Cooling Compatibility | Liquid nitrogen, closed-cycle cryocoolers, and programmable temperature controllers (4 K – 500 K typical range) |
| Compliance | Designed for GLP/GMP-aligned semiconductor defect characterization workflows |
| Brand | PIKE |
|---|---|
| Origin | USA |
| Model | 160-1900 |
| Type | Laboratory-Scale IR Sample Preparation Accessory |
| Material | Hardened Stainless Steel |
| Sample Diameter | 13 mm |
| Vacuum Interface | Standard Negative-Pressure Port |
| Includes | Stainless Steel Base with Vacuum Port, 13 mm Die Cavity, Two Polished Pressure Anvils, Precision-Machined Plunger, Two O-Rings (for Plunger Seal and Base Mounting) |
| Surface Finish | Mirror-Polished Contact Surfaces |
| Compliance | Designed for ASTM E1252 and USP <1119> FTIR Sample Preparation Protocols |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | PoolDirect 9-in-1 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PoolDirect |
| Pricing | Available Upon Request |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 1600 |
| Price | Upon Request |
| Wavelength Range | 325–1100 nm |
| Wavelength Repeatability | ≤1 nm |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.4% T |
| Optical System | Single-Beam with 1200 lines/mm Holographic Grating |
| Display | Large Backlit LCD (Wavelength Resolution: 1 nm) |
| Data Storage | Up to 100 calibration curves and 2000 measurement records |
| Interface | RS-232, USB flash drive support, Bluetooth 4.2 (for data export, mobile app sync, and optional thermal printer) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | Process Guardian™ |
| Instrument Type | In-line Raman Spectrometer |
| Laser Wavelength | 785 nm |
| Enclosure | 19-inch rack-mount industrial chassis |
| Control Architecture | Embedded real-time system with integrated display and HMI |
| Fiber Interface | FC/PC dual-fiber connector |
| Channel Expansion | Up to 8 channels via multiplexer integration |
| Safety Features | Laser fiber break detection, emergency stop interface |
| Optical Technology | HTVS™ (High-Throughput Virtual Slit) spectrograph |
| Regulatory Compliance | FDA 21 CFR Part 11 compliant data handling, ATEX/IECEx-certified options available for hazardous areas |
| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 185–900 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm) |
| Wavelength Repeatability | ≤0.05 nm (at D₂ line, 656.1 nm) |
| Spectral Bandwidth | Continuously Adjustable from 0.1 to 5.0 nm |
| Stray Light | ≤0.00004%T (NaI, 220 nm) |
| Stray Light | ≤0.00002%T (NaNO₂, 360 nm) |
| Photometric Range | –8 to +8 Abs |
| Baseline Flatness | ±0.0005 Abs |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.3%T (>1.0 Abs) |
| Photometric Repeatability | ≤0.001 Abs (0–0.5 Abs), ≤0.002 Abs (0.5–1.0 Abs), ≤0.1%T (>1.0 Abs) |
| Drift | ≤0.1%T/h |
| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TU-1901 / TU-1900 |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190 nm – 900 nm |
| Wavelength Accuracy | ±0.3 nm (auto-calibrated at startup) |
| Wavelength Repeatability | ≤0.15 nm |
| Spectral Bandwidth | 0.1 nm, 0.2 nm, 0.5 nm, 1.0 nm, 2.0 nm, 5.0 nm |
| Stray Light | ≤0.01%T at 220 nm (NaI), ≤0.05%T at 360 nm (NaNO₂) |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.3%T (0–100%T) |
| Photometric Range | –4.0 to +4.0 Abs |
| Baseline Flatness | ±0.001 Abs |
| Baseline Drift | 0.0004 Abs/h (at 500 nm, 0 Abs, after 2 h warm-up) |
| Photometric Noise | ±0.0004 Abs |
| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.3 nm (auto-calibrated at startup) |
| Wavelength Repeatability | ≤0.15 nm |
| Spectral Bandwidth | Continuously Variable from 0.1 to 5.0 nm (0.1 nm increments) |
| Stray Light | ≤0.01% T at 220 nm (NaI), ≤0.05% T at 360 nm (NaNO₂) |
| Baseline Flatness | ±0.001 Abs |
| Drift | ≤0.1%/h |
| Dimensions | 610 × 570 × 300 mm |
| Weight | 39 kg |
| Brand | Ocean Insight |
|---|---|
| Origin | USA |
| Detector Type | Back-Illuminated CCD |
| Spectral Range | Configurable from 185–1100 nm |
| Resolution | 18-bit ADC |
| Peak Quantum Efficiency | 90% |
| Signal-to-Noise Ratio | 1000:1 (full well, single acquisition) |
| Dynamic Range | 85,000 (typical, at full well capacity) |
| Stray Light | <0.08% at 600 nm |
| Cooling | Thermoelectrically cooled to –15 °C (stabilized ±0.1 °C) |
| Onboard Memory | 15,000 spectra buffer |
| Interface | USB 2.0 / USB 3.0 compatible |
| Slit Options | 5–200 µm (interchangeable) |
| Grating Options | Multiple groove densities and blaze wavelengths available |
| Internal Shutter | Optional for dark current optimization |
| Brand | Endress+Hauser |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RAMANRXN2 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Excitation Wavelength Options | 532 nm, 785 nm, or 1000 nm |
| Channel Configuration | Single-Channel (Standard), Optional 4-Channel Multiplexing |
| Probe Compatibility | Rxn-10 (with accessory optics), Rxn-30, Rxn-40, Rxn-41, Rxn-45, Rxn-46 |
| Hazardous Area Certifications | ATEX, IECEx, North American Class I Div 1/2, Class II Div 1/2 |
| Installation Form Factor | Benchtop or Mobile Cart-Mounted |
| Regulatory Compliance | Designed for cGMP/GLP environments, supports FDA 21 CFR Part 11–compliant audit trails when integrated with validated software platforms |
| Software Interface | Embedded touchscreen control with optional remote web-based access via Ethernet/Wi-Fi |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Nanophoton RAMANdrive |
| Instrument Type | Fourier Transform Raman Spectrometer |
| Spatial Resolution | 350 nm (X), 500 nm (Y), 1 µm (Z) |
| Brand | Rayleigh |
|---|---|
| Origin | Beijing, China |
| Model | WQF-600N |
| Instrument Principle | Fourier Transform (FT) |
| Wavenumber Range | 3300–10000 cm⁻¹ |
| Spectral Resolution | < 4 cm⁻¹ |
| Wavenumber Accuracy | Better than half the set resolution |
| Transmittance Repeatability | ±0.5% T |
| Signal-to-Noise Ratio (S/N) | >10,000:1 (RMS, 32 scans at 4300–4400 cm⁻¹) |
| Beam Splitter | CaF₂ |
| Detector Options | DTGS (PbS, InGaAs optional) |
| Light Source | Air-cooled tungsten-halogen lamp |
| Data System | PC-based with Windows OS |
| Software | Full-featured FT-NIR acquisition, preprocessing, chemometric modeling, and spectral analysis suite compliant with ASTM E1655 and ISO 12099 |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | inVia Basis |
| Instrument Type | Confocal Raman Microscope |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | XY ≈ 1 µm, Z ≈ 2 µm |
| Low-Wavenumber Limit | 10 cm⁻¹ |
| Spectral Reproducibility | ≤0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | inVia Qontor |
| Instrument Type | Confocal Raman Microscope |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | XY ≈ 1 µm, Z ≈ 2 µm |
| Low-Wavenumber Limit | 10 cm⁻¹ |
| Spectral Reproducibility | < ±0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | inVia Raman-AFM |
| Instrument Type | Confocal Micro-Raman Spectrometer with Integrated Atomic Force Microscopy |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | XY ≈ 1 µm, Z ≈ 2 µm |
| Low-Wavenumber Capability | down to 10 cm⁻¹ |
| Spectral Reproducibility | ≤0.1 cm⁻¹ |
| Coupling Architecture | Modular optical bridge for direct integration with third-party AFM/SPM platforms (e.g., Bruker Nano Surfaces, Nanonics, NT-MDT, JPK, Park Systems) |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | Raman-SCA-SEM |
| Instrument Type | Confocal Micro-Raman Spectrometer Integrated with Scanning Electron Microscope |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | XY ≈ 1 µm, Z ≈ 2 µm |
| Low-Wavenumber Capability | down to 10 cm⁻¹ |
| Spectral Reproducibility | ≤0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | inVia Reflex |
| Instrument Type | Confocal Raman Microscope |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | XY ≈ 1 µm, Z ≈ 2 µm |
| Low-Wavenumber Limit | 10 cm⁻¹ |
| Spectral Reproducibility | ≤0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | inVia™ InSpect |
| Instrument Type | Confocal Raman Microspectrometer |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | XY ≈ 1 µm, Z ≈ 2 µm |
| Low-Wavenumber Capability | down to 10 cm⁻¹ |
| Spectral Reproducibility | < ±0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | RA802 |
| Instrument Type | Confocal Micro-Raman Imaging System |
| Spectral Range | 100–3500 cm⁻¹ |
| Spectral Resolution | <2 cm⁻¹ |
| Spatial Resolution | ~500 nm |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | ≤±0.1 cm⁻¹ |