Spectroscopy Instruments
Filter
Showing 841–870 of 1322 results
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | RA816 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 100–3500 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ |
| Spatial Resolution | ~500 nm |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | Virsa Raman Analyzer |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 50–4000 cm⁻¹ |
| Spectral Resolution | <2.5 cm⁻¹ |
| Spatial Resolution | XY <0.5 µm, Z <2 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | <±0.1 cm⁻¹ |
| Brand | Ruihai Photonics (Oceanhood) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PL980 |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Spectral Resolution | ~4 nm @ 25 µm slit |
| Wavelength Accuracy | ≤3% peak-to-peak (@ 2 hrs) |
| Excitation Wavelength | 976 ± 3 nm, Linewidth < 0.2 nm |
| Laser Power Stability | ≤3% P-P (@ 2 hrs) |
| Laser Lifetime | 10,000 hrs |
| Output Power Range | 0–500 mW adjustable |
| Optical Density (OD) of Notch Filter | OD8 |
| Probe Working Distance | 7.5 mm |
| Probe Fiber Length | ~1.5 m |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 5–80% RH |
| Excitation Fiber Core | 105 µm VIS-NIR |
| Emission Collection Fiber Core | 200 µm VIS-NIR |
| Spectral Range | 1000–1700 nm |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable |
| Instrument Category | Fourier Transform |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | 0.01 cm⁻¹ |
| Scan Speed | 1 scan per 60 seconds |
| Signal-to-Noise Ratio (SNR) | 45,000:1 |
| Wavenumber Accuracy | ≤0.5 cm⁻¹ |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Instrument Type | Portable Handheld Raman Spectrometer |
| Model | AT-RS200 |
| Spectral Range | 200–3200 cm⁻¹ (Raman), 190–1100 nm (UV-Vis) |
| Spectral Resolution | ≤1 cm⁻¹ (Visible Raman), ≤2 cm⁻¹ (UV Raman) |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Repeatability | ≤±0.15 cm⁻¹ |
| Detection Modalities | Surface-Enhanced Raman Scattering (SERS), UV-Vis Absorption Spectrophotometry, Colloidal Gold Immunochromatographic Assay (CGIA) |
| Total Assay Coverage | ~600 analytes across food safety, environmental monitoring, and veterinary medicine |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Excitation Wavelength | 785 nm |
| Spectral Range | 200–3350 cm⁻¹ |
| Spectral Resolution | 4.5–10 cm⁻¹ (best ≤4.5 cm⁻¹ at 912 cm⁻¹) |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.15 cm⁻¹ |
| Brand | Sciencetech |
|---|---|
| Origin | Canada |
| Model | 9030 Series |
| Spectral Range | 250–700 nm |
| Stray Light | 1.00E−03 |
| Grating Configuration | Dual Grating (Subtractive Mode) |
| Focal Length | 100 mm (Input & Output) |
| Optical Layout | Seya-Namioka |
| Grating Type | Concave Holographic |
| f-number | f/3.2 |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.25 nm |
| Slit Options | Removable fixed-width slits (100 µm to 3 mm) |
| Detector Interface | Single-channel PMT-compatible output |
| Software Control | USB 2.0 (motorized version only) |
| Compliance | Designed for GLP/GMP-aligned spectroscopic workflows requiring traceable wavelength calibration and audit-ready operation |
| Brand | SEI |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | OreX |
| Price Range | USD 85,000 – 170,000 |
| Spectral Range | 350–2500 nm |
| Brand | AML |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SEMETROL HERA-DLTS |
| Price Range | USD 120,000 – 280,000 |
| Instrument Class | Semiconductor Defect Characterization System |
| Brand | AML |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SEMETROL HERA-DLTS |
| Price Range | USD 120,000 – 280,000 |
| Instrument Class | Semiconductor Defect Characterization System |
| Brand | SEMERSUN |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SEMETROL HERA-DLTS |
| Price Range | USD $105,000 – $210,000 |
| Instrument Class | Semiconductor Defect Characterization System |
| Brand | Serstech |
|---|---|
| Origin | Sweden |
| Model | Serstech 100 Indicator |
| Instrument Type | Handheld Raman Spectrometer |
| Spectral Range | 400–2300 cm⁻¹ |
| Spectral Resolution | 8–10 cm⁻¹ |
| Spatial Resolution | <1 nm |
| Minimum Wavenumber | 400 cm⁻¹ |
| Spectral Reproducibility | <1 cm⁻¹ |
| Laser Excitation Wavelength | 785 nm |
| Laser Power Class | Class 3B (max. 300 mW) |
| Detector | Linear CCD Array |
| Onboard Memory | 16 GB (up to 100,000 spectra) |
| Data Formats | Text, .txt, .csv, .jcamp |
| Interface | USB 2.0 |
| Battery Life | >8 hours continuous operation |
| Weight | 650 g |
| Dimensions | 15.8 × 10.1 × 2.9 cm |
| Brand | Serstech |
|---|---|
| Origin | Sweden |
| Model | Arx+ |
| Instrument Type | Handheld Raman Spectrometer |
| Spectral Range | 400–2300 cm⁻¹ |
| Spectral Resolution | 8–10 cm⁻¹ |
| Minimum Wavenumber | 400 cm⁻¹ |
| Spectral Repeatability | <1 cm⁻¹ |
| Laser Excitation Wavelength | 785 nm |
| Display | 3.5-inch color TFT with LED backlight |
| Onboard Storage | 16 GB (up to 100,000 spectra) |
| Operating Temperature | −20 to +50 °C |
| Storage Temperature | −30 to +50 °C |
| Battery Life | Up to 8 hours continuous operation |
| Weight | 590 g |
| IP Rating | IP67 |
| Focus Mechanism | Automatic focus |
| Detection Time | 0.01–60 s (manual or auto-triggered) |
| Sample Compatibility | Solids, liquids, powders, tablets |
| Regulatory Compliance | Fully compliant with FDA 21 CFR Part 11, supports IQ/OQ/PQ documentation |
| Brand | Shanda |
|---|---|
| Model | SD-FP7450 |
| Origin | Shandong, China |
| Detection Elements | K, Na, Li, Ca, Ba |
| Number of Channels | 5 |
| Measurement Range | 0.000–999.9 / 0–65535 (arbitrary units) |
| Detection Limits (mmol/L) | K ≤ 0.004, Na ≤ 0.008, Li ≤ 0.015, Ca ≤ 0.050, Ba ≤ 0.044 |
| Linearity Error (mmol/L) | K ≤ 0.005, Na ≤ 0.03, Li ≤ 0.021, Ca ≤ 0.075, Ba ≤ 0.066 |
| Response Time | ≤ 8 s |
| Nebulization Rate | < 6 mL/min |
| Stability | ≤ 3% RSD over 15 s |
| Repeatability | ≤ 3% RSD |
| Display | 7-inch capacitive color touchscreen |
| Output | Concentration values and relative emission intensity |
| Data Output | Built-in Bluetooth thermal printer, USB interface, optional PC software |
| Graphical Display | Real-time calibration curve and signal trend plotting |
| Compliance | Designed for routine quantitative analysis in accordance with ISO 11097:2010 (Water quality — Determination of sodium and potassium — Flame photometric method) and ASTM D1293 (Standard Test Methods for Electrical Conductivity and pH of Water) |
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Model | SD-ND600 |
| Wavelength Range | 185–910 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Resolution | ≤1.8 nm (FWHM at Hg 546 nm) |
| Absorbance Accuracy | ±1% (7.332 Abs at 260 nm) |
| Absorbance Precision | 0.002 Abs |
| Sample Volume | 0.5–2.0 µL |
| Pathlength Options | 0.02, 0.05, 0.1, 0.5, and 1.0 mm (automatically selected) |
| Measurement Time | ≤5 s per sample |
| Cuvette Mode OD600 Range | 0–4 A |
| dsDNA Quantitation Range | 2–38,880 ng/µL |
| BSA Protein Range | 0.06–820 mg/mL |
| Light Source | Pulsed Xenon Lamp (10-year lifetime) |
| Detector | 3648-pixel Linear CCD Array |
| Display | 7-inch Capacitive Touchscreen (Android OS) |
| Data Export | USB flash drive, SD-RAM card |
| Optional Fluorescence Module | Ex 460 nm / Em 525 nm |
| Dimensions (W×D×H) | 270 × 210 × 196 mm |
| Weight | 3.5 kg |
| Brand | INESA |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FP6410 / FP640 / 6400A |
| Price | Upon Request |
| Measurement Range | 0–100 ppm |
| Response Time | < 8 s |
| Repeatability | ≤2% |
| Sample Flow Rate | < 4 mL/min |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-2500 |
| Optical Design | Dual-beam with dual detectors |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1, 0.2, 0.5, 1, 2, and 4 nm (selectable) |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | ≤0.01% T |
| Automation | Automatic wavelength scanning and energy calibration |
| Light Source | Imported deuterium and tungsten-halogen lamps |
| Software | Integrated PC-based acquisition and analysis platform with GLP-compliant data handling |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3520AA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Reversal Method |
| Compliance | Meets GB/T 21187–2007 (Chinese National Standard for AAS), ASTM E1941, ISO 8288 |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3530AA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Absorption Method |
| Background Correction Capacity | >80× |
| Software Platform | Win-AAS Workstation |
| Data Output Modes | Time-Averaged Signal, Peak Height, Peak Area, Statistical Summary |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3590AA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical System | Single-beam, All-reflective Achromatic Optics |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-reversal (Self-absorption) Method |
| Safety Features | Automatic Lamp Switching, Graphite Tube Auto-diagnosis, Multi-point Radiation Shielding |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3801 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Absorption Method |
| Background Correction Efficiency | >50× (D₂), >100× (Self-Absorption) |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3802 |
| Instrument Type | Graphite Furnace AAS |
| Optical System | Dual-beam |
| Monochromator | Plane Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-absorption Method |
| Compliance | Designed for GLP/GMP-aligned laboratory workflows |
| Software | SPWin-AAS v3.x (Windows-based, 21 CFR Part 11-ready audit trail option) |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3803AA (Parallel Configuration) |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Echelle Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal (Self-Absorption) Method |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Software | Integrated PC-based workstation with audit trail capability |
| Regulatory Alignment | Supports GLP/GMP data integrity requirements per FDA 21 CFR Part 11 principles |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3887ZAA |
| Instrument Type | Flame–Graphite Furnace Hybrid AAS |
| Optical System | Single-beam |
| Monochromator | Not specified (conventional grating-based) |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Absorption + Transverse AC Magnetic Field Zeeman Correction |
| Graphite Furnace Configuration | Integrated Horizontal DC-heated Furnace with Automatic Resistance Compensation |
| Background Correction Modes | Three-mode selectable (D₂, Self-Absorption, Zeeman) |
| Safety | Multi-level hardware interlocks, STPF-compliant temperature control platform, Full PC automation with real-time monitoring |
| Lamp System | Motorized 8-lamp turret with auto-alignment |
| Viewing System | Integrated furnace viewing camera (real-time graphite tube status monitoring) |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-722 |
| Optical System | Single-beam |
| Detector | Photocell |
| Wavelength Range | 325–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | ≤0.5% T |
| Wavelength Adjustment | Manual |
| Compliance | CE-marked for laboratory use in accordance with IEC 61010-1 |
| Data Interface | RS-232 (optional USB adapter available) |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SP-723 |
| Optical System | Single-beam self-collimating optical path with 1200 lines/mm holographic grating |
| Detector | Photodiode array |
| Wavelength Setting | Automatic |
| Sample Chamber Capacity | Accommodates cuvettes from 5 mm to 100 mm pathlength |
| Minimum Sample Volume | 200 µL (with optional ultra-micro cuvette holder) |
| Display | 2-line × 20-character LCD |
| Data Output | Analog output + RS-232C serial interface |
| Compliance | Designed for educational, industrial QC, and environmental monitoring applications per standard laboratory practice guidelines (e.g., ISO/IEC 17025–aligned operation) |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | SP-752 |
| Price Range | USD 1,400–2,800 |
| Optical Design | Single-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Scanning Mode | Motorized Automatic Wavelength Selection |
| Wavelength Calibration | Self-Referencing Auto-Calibration via Spectral Feature Recognition |
| Displayed Parameters | Transmittance (%T), Absorbance (A), Concentration (c), Wavelength (nm) |
| Software Modules | Spectrum Scan, Kinetic (Time) Scan, Quantitative Analysis, Nucleic Acid (DNA/RNA) Analysis |
| Expandability | Modular Accessory Interface (e.g., cuvette holders, fiber-optic probes, temperature-controlled cells) |
| Compliance Framework | Designed to support GLP documentation workflows and basic ISO/IEC 17025 alignment for routine QC labs |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | SP-756P |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Optical Design | Dual-Beam with Ratio Monitoring |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 2 nm (nominal) |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | ≤0.05% T at 220 nm and 340 nm |
| Brand | Shanghai Youke |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Graphite Furnace AAS |
| Optical System | Single-beam |
| Background Correction | Deuterium Lamp + Self-reversal (SR) Dual-mode |
| Resolution | 0.2 nm |
| Characteristic Mass (for Graphite Furnace) | 0.05 pg for 1% absorption (Ag) |
| Repeatability (RSD) | ≤3% |
| Lamp Positions | 8-position motorized rotatable turret |
| Software Platform | RG-WinAAS for Windows OS |
| Compliance Context | Designed to support GLP-compliant workflows with audit-ready data logging and instrument parameter traceability |
| Brand | Shanghai Youke |
|---|---|
| Origin | Shanghai, China |
| Model | T-N6000SPlus |
| Optical System | Dual-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5 nm (selectable) |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Stray Light | ≤0.02% T at 220 nm & 360 nm |
| Display | 7-inch color TFT-LCD touchscreen |
| Data Storage | Internal 8 GB flash memory (supports ≥5000 absorbance readings or 500 calibration curves) |
| Processor | 32-bit ARM Cortex-M3 @ 120 MHz |
| Lamp Life | ≥2000 h (tungsten & deuterium lamps, auto-switched) |
| Grating | 1200 lines/mm holographic plane grating |
| Sample Compartment | Extra-large, compatible with 5-cell wide rack and 8-position rotating carousel |
| Connectivity | RS-232 printer port, USB Host (Type-B), USB Device (Type-A), optional Ethernet/WiFi module |
| Data Export Formats | .CSV, .QUA, .TXT, .BMP |
| Software | PC-based spectral acquisition & analysis suite with GLP-compliant audit trail, method validation tools, and FDA 21 CFR Part 11-ready optional modules |