BrandTA Instruments
OriginUSA
ModelNano ITC
Temperature Range2–80 °C
Cell Volume Options1.0 mL (standard) or 0.19 mL (low-volume)
Thermal ControlSolid-state Peltier heating/cooling
Injection SystemRemovable syringe with high-precision stepper motor drive
SoftwareITCRun and NanoAnalyze™
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTA Instruments
OriginUSA
ModelTAM IV
Simultaneous Sample CapacityMultiple
Temperature Range4–150 °C
Temperature Accuracy±0.1 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTA Instruments
OriginUSA
Instrument TypeDifferential Scanning Calorimeter (DSC)
Temperature Range–10 °C to 130 °C
Heating/Cooling Rate0.001–2 K/min
Cell Volume< 200 µL (capillary-based)
Pressure ControlIntegrated solid-state linear actuator with ±0.1 psi regulation
AutomationOptional DSC Auto autosampler (HPLC-grade precision)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTA Instruments
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelRS-DSC
Sample ThroughputMulti-sample simultaneous measurement
Instrument TypeDifferential Scanning Calorimeter (DSC)
Temperature Range20–100 °C
Temperature Accuracy±0.02 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTA Instruments
OriginUSA
ModelDiscovery DSC 2500
Instrument TypeDifferential Scanning Calorimeter
Temperature Range–180 °C to 725 °C
Temperature Accuracy±0.025 °C
Temperature Precision±0.005 °C
Heating/Cooling Rateup to 200 K/min
DSC Heat Flow Range±500 mW
Sample ThroughputSingle-sample configuration
Cooling OptionMechanical refrigeration (optional, extends low-temperature operation without LN₂)
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTA Instruments
OriginUSA
ModelDiscovery X3 DSC
Sample CapacityUp to 3 simultaneous samples
Instrument TypeHeat-Flow DSC
Temperature Range–180 °C to 550 °C
Temperature Accuracy±0.025 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTA Instruments
OriginUSA
ModelDiscovery DSC 25
Sample CapacitySingle
Instrument TypeDifferential Scanning Calorimeter (DSC)
Temperature Range−180 °C to 725 °C
Temperature Accuracy±0.1 °C
Heating/Cooling RateUp to 200 K/min
Temperature Precision±0.01 °C
DSC Heat Flow Range±500 mW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTA Instruments
OriginUSA
ModelDiscovery DSC 250
Instrument TypeDifferential Scanning Calorimeter (DSC)
Temperature Range−180 °C to 725 °C
Temperature Accuracy±0.05 °C
Temperature Precision±0.008 °C
Heating/Cooling Rateup to 200 K/min
DSC Heat Flow Range±500 mW
Sample CapacitySingle-sample configuration
Cooling OptionMechanical refrigeration (optional, extends low-temperature operation without liquid nitrogen)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTA Instruments
OriginUSA
ModelDiscovery DSC2500
Temperature Range–180 to 725 °C
Temperature Accuracy±0.025 °C
Temperature Precision±0.005 °C
Baseline Flatness (–50 to 300 °C)<5 μW
Baseline Repeatability (–50 to 300 °C)<10 μW
Enthalpy Accuracy±0.04 %
Heating/Cooling Rate0.1–100 K/min
Modulated DSCStandard
Tzero® TechnologyAdvanced (T4P)
Direct Cp MeasurementSupported
User-Replaceable FurnaceYes
54-Position AutosamplerStandard
Dual-Gas Delivery ModuleStandard
Color Touchscreen InterfaceStandard
Optical Accessory CompatibilityOptional
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTA Instruments
OriginUSA
ModelTAM 48
Simultaneous Sample CapacityUp to 48
Temperature Range4–150 °C
Temperature Accuracy±0.1 °C
Instrument TypeIsothermal Titration & Reaction Microcalorimeter
ComplianceDesigned for GLP/GMP environments with audit-trail-ready software architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTA Instruments
OriginUSA
ModelAffinity ITC / ITC Auto
Temperature Range2–80 °C
Cell Volume Options1.0 mL (standard) or 190 µL (low-volume)
Sample ThroughputMulti-sample via integrated 96-well autosampler
Temperature ControlActive solid-state heating/cooling with ±0.01 °C stability
Automation LevelFully automated titration, injection, cleaning, and cell positioning
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTA Instruments
OriginUSA
ModelDiscovery DSC 25P
Sample CapacitySingle
Instrument TypeDifferential Scanning Calorimeter (DSC)
Temperature Range–130 °C to 550 °C
Temperature Accuracy±0.1 °C
Heating/Cooling RateUp to 200 K/min
DSC Heat Flow Range±500 mW
Pressure Range1 Pa to 7 MPa (0.0001–1,000 psi)