| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 600 GHP |
| Measurement Principle | Guarded Hot Plate (GHP) |
| Compliance Standards | ASTM C177, ISO 8302, DIN EN 12667 |
| Operating Temperature Range | 90 °C to 250 °C |
| Sample Configuration | Single-specimen, symmetric arrangement |
| Thickness Measurement Method | Optical encoder-based digital displacement sensing |
| Temperature Uniformity Verification | 40 matched thermocouples |
| Thermal Stability Architecture | Dual-zone active temperature control with inert gas purge capability |
| Instrument Class | Primary-standard absolute thermal conductivity measurement system |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TMA 450 |
| Temperature Range | −150 to 1000 °C |
| Temperature Accuracy | ±1 °C |
| Force Range | 0.001–2 N |
| Frequency Range | 0.01–2 Hz |
| Displacement Resolution | 15 nm |
| Maximum Sample Length | 26 mm |
| Displacement Range | ±2.5 mm |
| Cooling Option | Mechanical Cooling Accessory (MCA 70) to −70 °C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | 3330 |
| Instrument Type | Dynamic Mechanical Tester (DMA/DMTA-Compatible Platform) |
| Frequency Range | 0.00001–100 Hz |
| Maximum Dynamic Load | ±3000 N |
| Maximum Dynamic Torque (with optional torsion module) | 28 N·m |
| Configuration Options | Benchtop or Floor-standing |
| Power Requirement | Standard 220 V AC outlet |
| Pneumatic Interface | Compressed air supply required |
| Structural Design | Rigid dual-column beam architecture |
| Vertical Stroke Adjustment | Integrated pneumatic/electric/manual lift mechanism |
| Multi-Axis Capability | Optional torsion motor for axial-torsional coupling |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 200 |
| Measurement Principle | Heat Flow Meter (HFM) Method |
| Thermal Conductivity Range | 0.005–0.35 W/m·K |
| Repeatability | ±0.5% |
| Accuracy | ±1% |
| Temperature Range | −20 °C to +75 °C |
| Minimum Sample Thickness | 0.025 mm |
| Compliance | ASTM C518, ISO 8301 |
| Control Modes | Standalone or PC-controlled |
| Software | WinTherm™ |
| Optional Automation | Robotic Auto-sampler |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 600 |
| Measurement Principle | Guarded Hot Plate / Heat Flow Meter Method (ASTM C518, ISO 8301) |
| Sample Thickness Range | Down to 0.025 mm (with digital thickness measurement) |
| Sensor Type | Dual thin-film heat flux sensors |
| Temperature Control | Responsive solid-state heating/cooling system |
| Software | WinTherm™ (compliant with 21 CFR Part 11 audit trail & user access control) |
| Automation Options | Optional auto-sampler and rotary sample stage |
| Compliance | ASTM C518, ISO 8301, ISO 8302 (guarded hot plate mode), GLP/GMP-ready configuration |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Nano ITC |
| Temperature Range | 2–80 °C |
| Cell Volume Options | 1.0 mL (standard) or 0.19 mL (low-volume) |
| Thermal Control | Solid-state Peltier heating/cooling |
| Injection System | Removable syringe with high-precision stepper motor drive |
| Software | ITCRun and NanoAnalyze™ |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DXF-200 / DXF-500 / DXF-900 |
| Measurement Principle | Laser Flash Method (Xenon Lamp-Based) |
| Maximum Sample Diameter | 25 mm |
| Pulse Width | 400–600 µs |
| Optical System | Reflective, Multi-Faceted Light Guide |
| Temperature Range Options | Up to 200 °C / 500 °C / 900 °C (Model-Dependent) |
| Compliance | ASTM E1461, ISO 22007-4, DIN EN 821-2 |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | 3500 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Frequency Range | 0.00001–100 Hz |
| Maximum Dynamic Load | 7.5 kN (standard), 15 kN (optional) |
| Dynamic Stroke | 50 mm |
| Cooling | Air-cooled |
| Motor Mounting Options | Upper Crosshead (3510), Base-Mounted (3520), High-Load Configuration (3550) |
| Brand | TA Instruments |
|---|---|
| Origin | Italy |
| Model | OPD 868 |
| Temperature Range | RT – 1650 °C |
| Heating Rate | 0.1 – 100 °C/min (up to 200 °C/sec in transient mode) |
| Temperature Accuracy | ±0.2 °C |
| Sample Length | 1 – 85 mm (mode-dependent) |
| Camera Resolution | 5 MP |
| Multi-sample Capability | Up to 8 ISO-standard specimens simultaneously |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 314 |
| Measurement Principle | Heat Flow Meter (HFM) Method |
| Thermal Conductivity Range | 0.005–0.35 W/m·K |
| Accuracy | ±1% |
| Temperature Range | Standard –20°C to 75°C |
| Thickness Resolution | 0.025 mm |
| Sensor Type | Dual Thin-Film Heat Flux Sensors |
| Compliance | ASTM C518, ISO 8301 |
| Software | WinTherm™ v5.x |
| Automation | Optional AutoSampler for unattended operation |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | TAM IV |
| Simultaneous Sample Capacity | Multiple |
| Temperature Range | 4–150 °C |
| Temperature Accuracy | ±0.1 °C |
| Brand | TA Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | FOX 801 |
| Price | Upon Request |
| Thermal Conductivity Range | 0.001–0.35 W/m·K |
| Accuracy | ±1% |
| Temperature Range | −10 to +65 °C |
| Thickness Measurement Resolution | 0.025 mm |
| Sensor Type | Dual Thin-Film Heat Flux Sensors |
| Compliance | ASTM C518, ISO 8301 |
| Cooling/Heating Method | Solid-State Peltier |
| Control Mode | Standalone or PC-Driven (WinTherm Software) |
| Optional Accessories | Automated Sample Changer, Rotational Sample Holder |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –10 °C to 130 °C |
| Heating/Cooling Rate | 0.001–2 K/min |
| Cell Volume | < 200 µL (capillary-based) |
| Pressure Control | Integrated solid-state linear actuator with ±0.1 psi regulation |
| Automation | Optional DSC Auto autosampler (HPLC-grade precision) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TGA 5500 |
| Temperature Range | Ambient to 1200 °C |
| Balance Sensitivity | < 0.1 µg |
| Heating/Cooling Rate | 0.1 to 500 °C/min |
| Maximum Sample Mass | 1 g |
| Baseline Drift | < 10 µg |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 821 / DIL 822 |
| Measurement Principle | Contact-based linear thermal expansion measurement using optical encoder and linear motor actuation |
| Resolution | 1 nm |
| Configuration | Vertical sample orientation |
| Force Control | Constant low-force contact via linear motor |
| Differential Capability | True differential measurement (DIL 822 only) |
| Compliance | ASTM E228, ISO 11359-1/-2, DIN 51045 |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | 3200 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA) / Dynamic Mechanical Thermal Analyzer (DMTA) |
| Temperature Range | −150 °C to +315 °C |
| Temperature Accuracy | ±0.3 °C |
| Force Range | ±225 N (optional ±450 N) |
| Displacement Range | ±6.5 mm |
| Frequency Range | 10⁻⁵ Hz to 300 Hz |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TMA 450 RH |
| Instrument Type | Thermomechanical Analyzer (TMA) |
| Temperature Range | −150 to 1000 °C |
| Temperature Accuracy | ±1 °C |
| Force Range | 0.001–2 N |
| Frequency Range | 0.01–2 Hz |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DLF 1600 |
| Measurement Principle | Laser Flash Method (LFA) |
| Maximum Operating Temperature | 1600 °C |
| Laser Pulse Energy | 1.35 J (Nd:Glass) |
| Pulse Width | 300–400 µs |
| Atmosphere Options | Air, Inert Gas, Vacuum (down to 10 Torr) |
| Furnace Heating Element | MoSi₂ |
| Insulation | High-Purity Alumina Hot Zone |
| Sample Capacity | Up to 6 positions with rotating carousel |
| Detector | Liquid Nitrogen-Cooled Infrared Detector |
| Beam Delivery | Patented Fiber-Optic Light Pipe (99% uniform transmission) |
| Compliance | ASTM E1461, ISO 22007-4, DIN EN 821-2 |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 200 HT |
| Measurement Principle | Heat Flow Meter (HFM) Method |
| Thermal Conductivity Range | 0.005–0.35 W/m·K |
| Repeatability | ±0.5% |
| Accuracy | ±1% |
| Temperature Range | −20 to 250 °C |
| Minimum Sample Thickness | 0.025 mm |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DMA 850 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | –160 to 600 °C |
| Force Range | 0.0001–18 N |
| Resolution (Displacement) | 0.1 nm over 25 mm travel |
| Bearing Type | Frictionless air bearing |
| Actuation | Non-contact lightweight motor |
| Control Technology | DirectStrain™, Auto-Ranging |
| Cooling | Integrated mechanical refrigeration (down to –100 °C without LN₂) |
| Software | TRIOS™ |
| Warranty | 5-year furnace warranty |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | RS-DSC |
| Sample Throughput | Multi-sample simultaneous measurement |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | 20–100 °C |
| Temperature Accuracy | ±0.02 °C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 50 |
| Thermal Conductivity Range | 0.1–10 W/m·K |
| Dimensions (L×W×H) | 250×170×360 mm |
| Accuracy | ±3% |
| Temperature Range | −10°C to 110°C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC 2500 |
| Instrument Type | Differential Scanning Calorimeter |
| Temperature Range | –180 °C to 725 °C |
| Temperature Accuracy | ±0.025 °C |
| Temperature Precision | ±0.005 °C |
| Heating/Cooling Rate | up to 200 K/min |
| DSC Heat Flow Range | ±500 mW |
| Sample Throughput | Single-sample configuration |
| Cooling Option | Mechanical refrigeration (optional, extends low-temperature operation without LN₂) |