- All
- Favorite
- Popular
- Most rated
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Model | NDJ-1 / NDJ-4 |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | 330XM |
| Heating Source | Halogen Lamp |
| Display | High-Contrast VFD Screen |
| Weighing System | Integrated 320XB Precision Electronic Balance |
| Sensor Technology | MFR Electromagnetic Force Restoration |
| Construction | Full Die-Cast Aluminum Housing |
| Calibration | External Calibration Mode |
| Compliance | Supports 3Q Validation (IQ/OQ/PQ) |
| Regulatory Features | Real-Time Clock, Password Protection, Mechanical Safety Interlock |
| Connectivity | Standard RS232 & USB |
| Brand | Dynamica |
|---|---|
| Origin | Germany |
| Model | V30R |
| Instrument Type | Benchtop High-Speed Refrigerated Centrifuge |
| Speed Range | 200–30,000 rpm (10 rpm increments) |
| Max RCF | 66,410 × g |
| Max Capacity | 6 × 250 mL |
| Temperature Range | −20 °C to +40 °C (1 °C increment) |
| Temperature Accuracy | ±1 °C |
| Acceleration/Deceleration Steps | 10/10 |
| Noise Level | <60 dB(A) |
| Dimensions (L×D×H) | 715 × 510 × 420 mm |
| Net Weight | 91 kg |
| Power Supply | 230 V, 50/60 Hz |
| Drive System | Brushless Induction Motor |
| Control System | Microprocessor-Based |
| Rotor Auto-Recognition | Yes (with overspeed protection) |
| Imbalance Detection | Yes |
| Timer Range | 30 s – 99 h 59 min + HOLD |
| Speed/RCF Conversion | Yes |
| Programmable Methods | 99 |
| Display | LCD |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | BC |
| Pricing | Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DNA800 |
| Pricing | Available Upon Request |
| Heating Temperature | Ambient to 300 °C |
|---|---|
| Heater Type | Band Heater |
| Sample Volume Capacity | ≤20 mL |
| Carrier Gas | Dry Nitrogen or Dry Air |
| Gas Flow Rate | 0–300 L/min |
| Maximum Gas Pressure | ≤0.8 MPa |
| Nitrogen Purity | ≥99.99% (High-Purity Grade) |
| Desiccant | 100 g Molecular Sieve |
| Safety Protections | Overtemperature Protection, Overpressure Gas Safety Cut-off |
| Power Supply | AC 100–240 V, 50/60 Hz, 100 W |
| Brand | Edinburgh Analytical |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory Benchtop FTIR Spectrometer |
| Wavenumber Range | 350–8000 cm⁻¹ |
| Spectral Resolution | 0.5 cm⁻¹ |
| Signal-to-Noise Ratio (SNR) | 20,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector) |
| Wavenumber Accuracy | ±0.05 cm⁻¹ |
| Optical Design | Michelson Interferometer with KBr Beamsplitter and Dynamically Aligned Mirror Drive |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Gascard NG |
| Operating Range | 0–5000 ppm to 0–100% (gas-dependent) |
| Pressure Compensation | 800–1150 mbar |
| Supply Voltage | 7–30 V DC |
| Communication Interface | RS232 |
| Light Source | Field-replaceable infrared source |
| Display Support | 4-bit and 128 × 64 pixel graphical LCD via expansion port |
| Target Gases | CO, CO₂, CH₄, N₂O (customizable) |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | EM120-HR |
| Heating Source | Halogen Lamp |
| Display | Backlit LCD with Graphical Real-Time Moisture Trend Plot |
| Construction | Full Cast-Aluminum Housing |
| Calibration | Fully Automatic Smart Calibration System (SCS) |
| Compliance | Supports 3Q Validation (IQ/OQ/PQ), GxP-Compliant Real-Time Clock, Multi-Level User Access Control with Password Protection |
| Software Features | Built-in Automatic Repeatability Test (ART), Checkweighing, Statistical Analysis |
| Connectivity | Standard RS232 & USB |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Mini-Tau |
| Spectral Dispersion | Interference Filter-Based |
| Instrument Type | Steady-State and Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 0–60 nm |
| Spectral Resolution | 50 nm |
| Signal-to-Noise Ratio | 3000:1 |
| Wavelength Accuracy | ±5 nm |
| Brand | Dynamica |
|---|---|
| Origin | Australia |
| Model | DB20R |
| Optical Design | Dual-beam |
| Detector Type | Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.0 nm |
| Stray Light | ≤0.05% (at 220 nm with NaI, 340 nm with NaNO₂) |
| Wavelength Accuracy | ±0.3 nm |
| Absorbance Range | –3.0 to +3.0 A |
| Transmittance Range | 0–300% T |
| Concentration Range | 0.000–9.999 units |
| Scan Speeds | 10–3600 nm/min (8 selectable rates) |
| Baseline Stability | 0.0003 A/hr (500 nm, 2 h) |
| Noise Level | 0.0003 A (500 nm, RMS) |
| Light Sources | Deuterium Lamp + Tungsten-Halogen Lamp |
| Automatic Lamp Switching | 325–370 nm |
| Interface | PC-controlled (no built-in display) |
| Dimensions (W×D×H) | 505 × 705 × 225 mm |
| Net Weight | 29 kg |
| Power Supply | 110–220 V AC, 50/60 Hz |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | FLS1000 |
| Dispersion Element | Grating Monochromator |
| Instrument Type | Steady-State and Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 0–30 nm |
| Optical Resolution | 0.05 nm |
| Sensitivity | 35,000:1 (RMS method) |
| Wavelength Accuracy | ±0.2 nm |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | UV2600 |
| Price Range | USD 9,800–13,900 (FOB Shanghai) |
| Optical Design | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Wavelength Scanning | Motorized, Software-Controlled |
| Spectral Bandwidth | 0.2, 0.5, 1, 2, 5 nm (Auto-Selectable) |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Stray Light | <0.010% T (at 220 nm, NaI |
| Brand | Nuaire |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | NU-543-300S / 400S / 500S / 600S |
| Instrument Type | Class II A2 Biological Safety Cabinet |
| External Dimensions (L×W×H, mm) | 1057 / 1362 / 1669 / 1972 × 799 × 1572 |
| Internal Dimensions (L×W×H, mm) | 873 / 1178 / 1483 / 1788 × 654 × 724 |
| Filter Efficiency | ≥99.995% at 0.3 µm |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrumentation |
| Model | Boxed Gascard |
| Operating Voltage Range | 7–30 V DC |
| Communication Interface | RS232 (optional) |
| Onboard Pressure Compensation Range | 800–1150 mbar |
| Infrared Source | Field-replaceable |
| Temperature Compensation | Wide-range, integrated |
| Brand | Scion |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 8500-GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Maximum Ramp Rate | 170 °C/min |
| Maximum Cooling Rate | 150 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic UHPLC System |
| Model | LC6000-FLD |
| Instrument Type | Ultra-High Performance Liquid Chromatograph with Fluorescence Detection |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Pressure | 60 MPa |
| Flow Precision | <0.05% RSD |
| Sample Tray Capacity | 200 positions (1.5 mL vials) |
| Optional | 128 positions (4 mL vials), 288 positions (96-well microplate), 1152 positions (384-well microplate) |
| Injection Volume Range | 0.1–100 µL (standard) |
| Excitation Wavelength Range | 200–850 nm |
| Emission Wavelength Range | 250–900 nm |
| Data Acquisition Frequency | Multi-step adjustable |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | YLS-B Series |
| Price Range | USD 700 – 1,400 (FOB) |
| Heating Method | Halogen Lamp |
| Max Capacity | 60 g (YLS-B Plus) / 20 g (YLS-B Standard) |
| Readability | 1 mg (60 g model) / 2 mg (20 g model) |
| Moisture Resolution | 0.02–0.1% |
| Temperature Range | 50–160 °C (1 °C increments) |
| Heating Time | 0–99 min (1 min steps) |
| Display | Backlit dot-matrix LCD with dual blue/white background |
| Data Storage | 50 sample profiles |
| Interface | RS232C |
| Calibration | External weight calibration (20 g for YLS-B |
| Compliance | Supports IQ/OQ/PQ validation |
| Power Supply | 220 VAC (±15%/+10%), 50 Hz |
| Power Consumption | 300 W |
| Operating Environment | 5–40 °C, 25–85% RH (non-condensing) |
| Recommended Ambient | 15–30 °C, 50–75% RH (non-condensing) |
| Dimensions (W×D×H) | 458 × 278 × 246 mm |
| Net Weight | 5.5 kg |
| Brand | Dynamica |
|---|---|
| Origin | Shanghai, China |
| Model | VELOCITY 18R |
| Instrument Type | Benchtop Centrifuge |
| Function | Refrigerated Centrifugation |
| Configuration | Horizontal Rotor System |
| Max. Capacity | 4 × 300 mL |
| Max. Speed | 18,000 rpm |
| Max. RCF | 30,318 × g |
| Dimensions (L×W×H) | 730 × 610 × 380 mm |
| Net Weight | 100 kg |
| Power Supply | AC 220 V, 50/60 Hz, 10 A |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±2 °C |
| Noise Level | <58 dB(A) |
| Acceleration | 9 levels |
| Deceleration | 10 levels |
| Rotor Recognition | Automatic, non-contact |
| Imbalance Detection | Non-contact electronic sensing |
| Speed Range | 300–18,000 rpm (100 rpm increments) |
| Speed Accuracy | ±20 rpm |
| Timer | 1 min – 99 h 59 min + Hold function |
| Memory | 9 programmable protocols |
| Drive | Brushless induction motor |
| Display | Backlit LCD panel |
| Pre-cool Function | Yes |
| Sample Temperature Monitoring | Real-time rotor-based temperature measurement |
| Brand | ISOTOPX |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Phoenix |
| Instrument Type | Thermal Ionization Mass Spectrometer (TIMS) |
| Resolution | >450 |
| Dynamic Range (ATONA Amplifier) | 100 V |
| Mass Drift | <20 ppm over 40 min |
| Faraday Cup Lifetime | ≥10 years (Phoenix X62) |
| Vacuum Pumping Speed | Highest among commercial TIMS systems |
| Sample Capacity | 20-position rotatable carousel orthogonal to ion beam axis |
| Optional Detectors | Daly detector, Secondary Electron Multiplier (SEM), Multi-Collector Ion Counter with Conversion Dynode technology |
| Optional WARP Retarding Field Filter | Enables abundance sensitivity <1×10⁻⁸ for ²³⁷U/²³⁸U |
| Ion Extraction Slit | Enlarged for enhanced sensitivity |
| Focal Plane Rotation | Motorized, orthogonal to ion trajectory |
| Sample Chamber | Stainless steel with multiple auxiliary ports (pre-heating, cryo-trap, oxygen inlet) |
| Software | Fully integrated, GLP-compliant, remote operation enabled |
| Regulatory Compliance | Designed to support 21 CFR Part 11 audit trails, ISO/IEC 17025 data integrity requirements, and ASTM D7938 (TIMS-based isotope ratio analysis) |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model Series | FIR-295, FIR-395, FIRL100 |
| Core Technology | CO₂-laser-pumped molecular gas laser |
| Wavelength Range | 40 µm – 1.22 mm (0.25–7.5 THz) |
| Output Power | ≥150 mW (PL5-pumped), ≥500 mW (PL6-pumped) at selected lines (e.g., 118.8 µm, 184.3 µm) |
| Construction | Invar-stabilized resonator frame, hollow metallic waveguide, dichroic output coupler |
| Cooling | Integrated water-cooling system |
| Vacuum Level | High-vacuum operation (<10⁻⁵ mbar) |
| Compliance | Designed for laboratory-based THz research under ISO/IEC 17025-aligned environments |
| Brand | Dynamica |
|---|---|
| Origin | Australia |
| Model | DB-30 |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1–5.0 nm (6 selectable slits) |
| Stray Light | ≤0.01%T (220 nm NaI, 340 nm NaNO₂) |
| Wavelength Accuracy | ±0.3 nm |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs, NIST 900D) |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs, NIST 930D) |
| Baseline Flatness | ±0.001 Abs (200–850 nm) |
| Baseline Stability | 0.0004 Abs/hr (500 nm, after 2 hr) |
| Noise Level | ±0.0003 Abs (500 nm) |
| Scan Speeds | 1–2,000 nm/min (8 selectable rates) |
| Light Sources | Tungsten-halogen & Deuterium lamps with automatic switching (325–370 nm) |
| Detector | Photomultiplier tube (PMT) |
| Control OS | Windows XP or Windows 7 Pro |
| Dimensions | 710 × 630 × 268 mm (W×D×H) |
| Net Weight | 50 kg |
| Power | 110–220 V AC, 50/60 Hz, 300 VA |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Guardian NG |
| Price Range | USD 3,800 – 5,100 (FOB UK) |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | FS5 v2 |
| Dispersion Element | Grating |
| Instrument Type | Steady-State and Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 0–30 nm |
| Optical Resolution | 0.01 nm |
| Sensitivity | 4000:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±0.5 nm |
| Excitation Sources | Xenon Arc Lamp, Pulsed Laser Diodes (e.g., 375 nm, 405 nm, 445 nm, 485 nm, 635 nm), Optional OPO/UV Laser Systems |
Show next