Thermogravimetric Analyzer
Filter
Showing 91–102 of 102 results
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | THEMYS LV |
| Temperature Range | Room Temp to 2000 °C (TGA/DTA/TG-DTA), up to 1600 °C (TG-DSC/DSC/TMA) |
| Sample Capacity | Up to 100 g / 18.1 mL |
| Balance Sensitivity | 0.02 µg |
| Heating/Cooling Rate | 0.01–20 K/min |
| Maximum Crucible Volume | 18.1 mL |
| TMA Resolution | 1.6 nm |
| TMA Measurement Range | ±6 mm |
| Gas Control | 3-channel MFC-controlled gas lines (including optional corrosive gas path) |
| Vacuum Capability | Primary vacuum (< 5×10⁻² mbar), secondary vacuum optional |
| Balance Load Capacity | ±200 mg (low-load mode), ±2000 mg (high-load mode) |
| DSC/DTA Accuracy | ±2% (heat flow), ±1 °C (temperature, calibrated vs. metal standards) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery HP-TGA 75 / 750 / 7500 |
| Temperature Range | Up to 1100 °C |
| Balance Sensitivity | 0.1 µg |
| Operating Environment | Controlled High-Pressure Atmosphere (up to 75, 750, or 7500 psi) |
| Instrument Type | Benchtop Integrated High-Pressure TGA System |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software architecture |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TGA 550 |
| Temperature Range | Ambient to 1000 °C |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 1 g |
| Baseline Drift | <25 µg |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TGA 5500 |
| Temperature Range | Ambient to 1200 °C |
| Balance Sensitivity | < 0.1 µg |
| Heating/Cooling Rate | 0.1 to 500 °C/min |
| Maximum Sample Mass | 1 g |
| Baseline Drift | < 10 µg |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | RZY-1 / RZY-2 |
| Price Range | USD 7,000 – 14,000 |
| Temperature Range | Ambient to 1400 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 1–50 °C/min |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Themy HP TGA |
| Temperature Range | RT to 1200 °C |
| Maximum Operating Pressure | ≤150 bar |
| Balance Sensitivity | 0.023 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Mass Resolution | ≤0.03 µg |
| Sample Capacity | up to 100 g |
| Mass Dynamic Range | ±2000 mg / ±200 mg |
| Vacuum Level | <10⁻² mbar |
| Atmosphere Compatibility | O₂, H₂, CO, CO₂, CH₄, N₂, Ar, He, and reactive/corrosive gases |
| Cooling Method | Integrated water cooling (cool-down time <20 min) |
| Temperature Accuracy | ±0.1 K |
| Baseline Noise | Ultra-low, enabling high-fidelity kinetic analysis under pressure |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q5000IR, Q500, Q50 |
| Pricing | Upon Request |
| Brand | NANJING DAZHAN |
|---|---|
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1200 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Max Sample Mass | 30 g |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidative, reductive, static/dynamic) |
| Balance Resolution | 0.1 µg |
| Balance Accuracy | ±0.01 mg |
| Temperature Stability | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Display | 7-inch 24-bit color touchscreen |
| Communication | USB 2.0 bidirectional interface |
| Software | Integrated TGA analysis suite with TG/DTG curve fitting, multi-point temperature calibration, Excel/PDF export, GLP-compliant report generation |
| Brand | ISI |
|---|---|
| Origin | USA |
| Model | TGA 1000 |
| Temperature Range | RT–1000°C |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.1–300 K/min |
| Maximum Sample Mass | 0.4 g |
| Sample Capacity | Single |
| Environment | High-Temperature/Controlled-Atmosphere |
| Construction | Stainless Steel Gas Pathway |
| Cooling | Water-Cooled Furnace |
| Software Platform | Infinity Pro for Windows |
| Compliance | ASTM E1131, ISO 11358, USP <691>, GLP-Ready |
| Brand | ISI |
|---|---|
| Origin | USA |
| Model | TGA 1500 |
| Temperature Range | RT–1000 °C |
| Balance Sensitivity | 0.1 μg |
| Heating/Cooling Rate | 0.1–300 K/min |
| Maximum Sample Mass | 0.4 g |
| Sample Capacity | Single |
| Environment | High-Temperature/Controlled-Atmosphere |
| Construction | Stainless-Steel Dual-Gas Purge System |
| Software Platform | Infinity Pro for Windows |
| Optional Modules | EGA Interface with Heated Transfer Line, Auto Gas Switching, Step ISO Compliance Mode, Water-Cooled Furnace |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | YT-TCD-101 |
| Temperature Range | Ambient to 1150 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating Rate | 1–80 °C/min |
| Cooling Time | 15 min (from 1000 °C to 100 °C) |
| Balance Capacity | 1 mg–2 g (extendable to 30 g) |
| Balance Resolution | 0.1 µg |
| Isothermal Hold Duration | 0–300 min (user-configurable) |
| Atmosphere Control | Dual-gas inlet with mass flow control (inert, oxidizing, reducing, static, dynamic) |
| Data Interface | RS-232 |
| Software | Integrated TGA analysis suite with automated curve recording, baseline correction, derivative (DTG) calculation, kinetic modeling (e.g., Kissinger, Ozawa), and GLP-compliant reporting |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Zhonglu |
|---|---|
| Model | TGA-1250Q |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Temperature Range | Ambient to 1350 °C |
| Temperature Accuracy | ±0.01 °C |
| Temperature Resolution | 0.1 °C |
| Dynamic Weighing Range | 0.01 mg to 30 g |
| Balance Sensitivity | 0.1 μg |
| Mass Accuracy | ±0.00001 g |
| Heating/Cooling Rate | 1–80 °C/min |
| Maximum Sample Mass | 30 g |
| Baseline Repeatability | 25 ppm/10 °C |
| Baseline Drift | 25 ppm/10 °C |
| Atmosphere Control | Dual-gas inlet with mass flow control (inert, oxidizing, reducing, static/dynamic) |
| Cooling Time | ≤15 min (1000 °C → 100 °C) |
| Data Interface | RS-232 |
| Compliance | Patented in China (CN Patent No. disclosed upon request) |