Thermogravimetric Analyzer
Filter
Showing 31–60 of 102 results
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-TGA-101 |
| Temperature Range | Ambient to 1150 °C (optional upgrade to 1450 °C) |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.01 mg |
| Heating/Cooling Rate | 1–80 °C/min |
| Balance Capacity | 1 mg–2 g (expandable to 30 g) |
| Isothermal Hold Time | 0–300 min |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidizing, reducing, static, dynamic) |
| Data Interface | USB |
| Compliance | ASTM E1131, ISO 11358, USP <41>, GLP-ready software audit trail |
| Brand | Jiubin Instruments |
|---|---|
| Temperature Range | Ambient to 1450 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating Rate | 1–80 °C/min |
| Cooling Time | 15 min (from 1000 °C to 100 °C) |
| Balance Capacity | 1 mg–2 g (expandable to 30 g) |
| Mass Sensitivity | 0.01 mg |
| Isothermal Hold Time | 0–300 min |
| Atmosphere Control | Dual-gas manifold with mass flow regulation (inert, oxidative, reductive, static, dynamic) |
| Data Interface | USB |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 489 × 400 × 343 mm |
| Brand | JByq |
|---|---|
| Origin | Shanghai, China |
| Model | JB-TGA-1550 |
| Temperature Range | Ambient to 1550 °C |
| Balance Sensitivity | 0.01 µg |
| Heating/Cooling Rate | 0.1–80 K/min |
| Atmosphere | Ambient pressure, dual-gas control (N₂/O₂) |
| Sample Capacity | Single sample, 0.1 mg–2 g (expandable to 50 g) |
| Temperature Stability | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Isothermal Duration | 0–300 min adjustable |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Data Interface | USB |
| Software | Proprietary TGA analysis suite with TG/DTG overlay, % mass conversion, Excel export, and report generation |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TGA801 |
| Price | Upon Request |
| Temperature Range | 100 °C to 1000 °C |
| Temperature Accuracy | ±0.5 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | Up to 15 K/min |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | STA/TGA L86 |
| Instrument Type | Universal Simultaneous Thermal Analyzer |
| Temperature Range | −150 °C to 2400 °C |
| Balance Sensitivity | 0.01 µg |
| Maximum Sample Capacity | 35 g / ±20000 mg |
| Vacuum Capability | 10⁻² mbar (pump-dependent) |
| Pressure Range (optional) | up to 5 bar |
| Heating Rate | 0.01–100 K/min |
| TG Resolution Options | 0.01 µg / 0.02 µg / 0.1 µg |
| DSC Sensor Types | E, K, S, B, C (C = DTA-only) |
| DSC Resolution | 0.3–1.2 µW |
| DTA Resolution | 0.03 nV |
| DTA Sensitivity | 1.5 µV/mW |
| DTA Range | ±250 µV / ±2500 µV |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TGA HP L85 |
| Temperature Range | RT to 1200 °C |
| Pressure Range | up to 150 bar |
| Balance Sensitivity | 0.1 µg |
| Maximum Sample Mass | 5 g |
| Vacuum Level | 10⁻⁴ mbar |
| Heating Rate | up to 300 K/min |
| Cooling Rate | up to 150 K/min |
| TG Sensor Types | E, K, S, B, C |
| TG-DSC Sensor Types | E, K, S, B, C |
| Interface | USB or Ethernet |
| Gas Configuration | 1–3 configurable gas channels (customizable) |
| Optional Accessories | Steam Generator, H₂/HC Auto-Vent & Gas Safety System |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TGA L81 |
| Temperature Range | –150 to 2400 °C |
| Balance Sensitivity | 0.1 µg |
| Maximum Sample Mass | 25 g |
| Vacuum Tightness | 10⁻² mbar |
| Optional DTA Calculation | Yes |
| Interface | USB |
| Compatibility | MS and/or FTIR for Evolved Gas Analysis (EGA) |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TGA L83 |
| Temperature Range | RT to 1100 °C |
| Heating/Cooling Rate | 0.001–250 °C/min |
| Maximum Sample Mass | 5 g |
| Cooling Time | <12 min (1100 °C → 100 °C) |
| Vacuum Capability | up to 10⁻³ mbar |
| Atmosphere Control | Inert, oxidative, reductive, vacuum |
| Gas Dosing | Integrated MFC module with 3 gas channels (1 purge + 2 reactive) |
| Sample Autosampler | Up to 90 positions |
| Crucible Materials | Pt, Al₂O₃, Au, Ag, Al, graphite, W, stainless steel (HP) |
| EGA Compatibility | FTIR, MS, GC-MS |
| Interface | USB |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TGA L87 MSB |
| Temperature Range | –196 to 2400 °C |
| Balance Sensitivity | 1 µg |
| Maximum Sample Mass | 10 g (standard balance) |
| Measurement Environment | Ultra-High Vacuum (UHV) to 150 bar (metal version) |
| Gas Analysis Compatibility | Mass Spectrometry (MS) and FTIR coupling supported |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKC-G1A |
| Price Range | USD 14,000–28,000 (FOB) |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | Dedicated Microwave TGA System |
| Temperature Range | 0–300 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Uniformity | ±3 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | Up to 100 K/min |
| Maximum Sample Mass | 500 g |
| Microwave Frequency | 2450 MHz |
| Rated Microwave Power | 800 W (Continuously Adjustable, Non-Pulsed) |
| Cavity Volume | ~20 L |
| Balance Resolution | 0.01 g |
| Exhaust Mode | Negative-Pressure Ventilation |
| Safety Leakage | <5 mW/cm² (per GB 10436 & IEC 62233) |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dedicated Microwave TGA |
| Temperature Range | 0–900 °C |
| Temperature Accuracy | ±3 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | Up to 100 K/min |
| Microwave Frequency | 2450 MHz |
| Rated Microwave Power | 800 W (Continuously Adjustable, Non-Pulsed) |
| Balance Capacity | 50 g |
| Balance Resolution | 0.001 g |
| Chamber Volume | ~8 L |
| Microwave Leakage | <5 mW/cm² (Compliant with GB 10436 & IEC 62233) |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKC-R1A |
| Price Range | USD 14,000–28,000 |
| Temperature Range | 0–900 °C |
| Temperature Accuracy | ±3 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | Up to 100 K/min |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | MKC-R1B |
| Price Range | USD 14,000–28,000 (FOB) |
| Temperature Range | 0–800 °C (up to 900 °C for short-term operation) |
| Temperature Accuracy | ±3 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | Up to 100 K/min |
| Microwave Frequency | 2450 MHz |
| Rated Microwave Power | 800 W (continuously adjustable, non-pulsed) |
| Balance Capacity | 50 g |
| Internal Cavity Volume | ~500 mL |
| Microwave Leakage | <5 mW/cm² |
| Compliance | ISO 9001 certified |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 3 Excellence Series |
| Temperature Range | −150 °C to 700 °C |
| Data Acquisition Rate | Up to 50 data points per second |
| Sensor Type | MultiSTARe™ DSC sensor with 56 or 120 thermocouple pairs (Au/Au-Pd) |
| Cooling Rate | 0.02 K/min to 50 K/min |
| Calibration | FlexCal® (fully automated, multi-point, reference-based) |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1/1100 |
| Temperature Range | Ambient to 1100 °C |
| Temperature Accuracy | ±0.25 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| Baseline Repeatability | ±10 µg (full temperature range) |
| Sensor Type | Single-disk SDTA with Pt–Pt/Rh thermocouples |
| Modular Configuration | Optional autosampler, vacuum pump, MS/FTIR coupling, humidity control module |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1/1600 |
| Temperature Range | Ambient to 1600 °C |
| Temperature Accuracy | ±0.5 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| Baseline Repeatability | ±10 µg (full temperature range) |
| Sensor Type | Single-Pan SDTA (Simultaneous Differential Thermal Analysis) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 2 |
| Instrument Type | Universal |
| Temperature Range | RT to 1100 °C or 1600 °C |
| Balance Sensitivity | 0.1 µg / 1 µg (model-dependent) |
| Heating/Cooling Rate | 0.02–150 K/min (standard furnace) / up to 250 K/min (fast furnace) |
| Dynamic Weighing Range | 1 g / 5 g (model-dependent) |
| Balance Accuracy | 0.005% |
| Balance Precision | 0.0025% |
| Resolution | Sub-microgram across full weighing range |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ Advanced |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02–150 K/min / 0.02–250 K/min |
| DSC Sensor | 6-pair Pt/Pt-Rh thermocouples |
| Simultaneous Measurement Capability | Yes |
| Modular Configuration | Standard |
| Compliance Ready | ASTM E1131, ISO 11358, USP <1163>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02–150 K/min / 0.02–250 K/min |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Sample Capacity | Multi-sample (with optional autosampler) |
| Instrument Type | Modular, general-purpose simultaneous TGA/DSC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ Standard |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02 to 150 K/min / 0.02 to 250 K/min |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Simultaneous Measurement Capability | Yes |
| Modular Configuration | Yes |
| Compliance Ready | ASTM E1131, ISO 11358, USP <1227>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 LF (Large Furnace) / TGA2 SF (Small Furnace) |
| Temperature Range | Up to 1100 °C (LF), Up to 600 °C (SF) |
| Temperature Accuracy | ±0.5 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.001–100 K/min |
| Furnace Type | Dual-furnace modular architecture |
| Compliance | ASTM E1131, ISO 11358, USP <41>, FDA 21 CFR Part 11 ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 |
| Temperature Range | RT to 1100 °C |
| Balance Sensitivity | 0.1 µg / 1 µg (depending on balance module) |
| Heating/Cooling Rate | 0.02 to 150 K/min |
| Temperature Accuracy | ±1 K |
| Blank Curve Repeatability | < ±10 µg across full temperature range |
| Sensor Type | Single-pan SDTA (Simultaneous Differential Thermal Analysis) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 |
| Temperature Range | 30 °C – 1,100 °C |
| Sampling Rate | 10 data points/second |
| Atmosphere Control | Integrated Mass Flow Controller (MFC) for programmable gas switching |
| Buoyancy Correction | Automatic, model-based, no blank required |
| One-Click Method Launch | Yes |
| Optional Couplings | FTIR, MS, Micro GC, GC/MS |
| Sensor Output | Mass & Temperature |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | DZ-TGA 101 |
| Structure Type | Top-loading / Upper-mounted |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single-sample |
| Instrument Type | General-purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Temperature Accuracy | ±0.01 K |
| Balance Sensitivity | 0.01 mg |
| Heating/Cooling Rate | 1–80 °C/min |
| Maximum Sample Mass | 30 g |
| Baseline Drift | ≤0.1 mg |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.01 °C |
| Mass Range | 0.1 mg–30 g |
| Atmosphere Control | Dual-gas channel with integrated mass flow meters and manual flow regulation |
| Data Interface | Standard USB |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 500×400×430 mm |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1150 °C |
| Temperature Accuracy | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Dynamic Weight Range | 0.01 mg to 3 g |
| Balance Sensitivity | 0.01 mg (up to 2 g), extendable to 30 g |
| Mass Accuracy | 0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass Capacity | 30 g |
| Baseline Drift | Negligible (<0.1 µg over 60 min at constant temperature) |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidizing, reducing, static/dynamic) |
| Cooling Time | ≤15 min (1000 °C → 100 °C) |
| Isothermal Hold Duration | 0–500 min (extendable to 72 h) |
| Data Acquisition | 24-bit quadruple-channel ADC for TG, DTG, DSC (optional), and temperature signals |
| Controller Architecture | 32-bit ARM Cortex-M3 microcontroller + dedicated 8-bit MCU for water-cooling subsystem |
| Interface | USB 2.0 (bidirectional), touch-screen and PC remote control supported |
| Software | Integrated Windows-based analysis suite with ASTM/ISO-compliant reporting, multi-point temperature calibration, Excel/PDF export, GLP audit trail logging |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | DZ-TGA101 |
| Test Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 3 g |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Baseline Repeatability | Excellent |
| Baseline Drift | Negligible |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | DZ-TGA101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Dynamic Weighing Range | 0.01 mg to 2 g (extendable to 30 g) |
| Mass Accuracy | 0.01 mg |
| Mass Resolution | 0.1 µg |
| Isothermal Hold Time | 0–500 min (expandable to 72 h) |
| Cooling Time | ≤15 min (from 1000 °C to 100 °C) |
| Atmosphere Control | Dual-gas inlet with integrated mass flow meters |
| Display | 7-inch Chinese-language LCD touchscreen |
| Data Interface | Standard USB port |
| Software | Proprietary TGA analysis suite with multi-point temperature calibration, TG/DTG curve processing, Excel export, PDF report generation, and audit-ready experimental logging |
| Power Supply | AC 220 V, 50 Hz (customizable) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | DZ-TGA101 |
| Test Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 3 g |
| Mass Accuracy | ±0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Mass Resolution | 0.01 mg |
| Maximum Sample Mass | 30 g |
| Baseline Repeatability | Excellent |
| Baseline Drift | Negligible |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Atmosphere Control | Dual-Gas Flow Regulation (Inert, Oxidizing, Reducing, Static, Dynamic) |
| Data Interface | USB 2.0 |
| Software | Integrated TG/DTG Analysis Suite with Excel Export, PDF Report Generation, Multi-Point Temperature Calibration, and GLP-Compliant Audit Trail |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA101 |
| Price Range | USD 7,000–14,000 (FOB) |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1200 °C |
| Balance Sensitivity | 0.1 µg (Resolution), 0.01 mg (Accuracy) |
| Mass Range | 0.01 mg–2 g (expandable to 30 g) |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Isothermal Hold Duration | 0–500 min (extendable to 72 h) |
| Atmosphere Control | Dual-gas inlet with mass flow control (inert, oxidizing, reducing, static, dynamic) |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Data Interface | Standard USB 2.0 |
| Software | Proprietary Windows-based TGA analysis suite with ASTM/ISO-compliant reporting, Excel export, PDF report generation, multi-point temperature calibration, and full remote instrument control |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DZ-TGA101 |
| Testing Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 3 g |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |