Thermogravimetric Analyzer
Filter
Showing 61–90 of 102 results
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1200 °C |
| Balance Sensitivity | 0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Balance Range | 0.1 mg–3 g (extendable to 30 g) |
| Isothermal Hold Duration | Up to 72 h (0–300 min programmable in 0.1 min increments) |
| Atmosphere Control | Dual-gas manifold with mass flow regulation (inert, oxidative, reductive, static, dynamic) |
| Data Acquisition | 48-bit quadruple-channel ADC for simultaneous TG, DTG, DSC (optional), and temperature signals |
| Interface | USB 2.0 (bidirectional) |
| Display | 7-inch 24-bit color touchscreen (Chinese/English UI) |
| Calibration | On-screen TG baseline and temperature multi-point calibration |
| Power Supply | AC 220 V, 50 Hz (customizable) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DZ-TGA101 |
| Price Range | USD 7,000–14,000 (FOB) |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single-sample |
| Instrument Type | General-purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Balance Sensitivity | 0.1 mg to 3 g (standard), extendable to 30 g |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Atmosphere Control | Dual-gas channel with mass flow control (inert, oxidizing, reducing, static, dynamic) |
| Data Interface | USB 2.0 |
| Software | Proprietary TGA analysis suite with TG/DTG curve fitting, Excel/PDF export, GLP-compliant audit trail, multi-point temperature calibration, and remote instrument control |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1200 °C |
| Balance Sensitivity | 0.1 mg to 3 g (standard range), 1 mg to 2 g (high-precision range) |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Balance Accuracy | 0.01 mg |
| Minimum Mass Resolution | 0.1 µg |
| Isothermal Hold Duration | Up to 72 h (0–300 min programmable in 0.1 min increments) |
| Atmosphere Control | Dual-gas channel with integrated mass flow meters |
| Display | 7-inch high-resolution Chinese-language LCD touchscreen |
| Data Interface | Standard USB port |
| Software | Proprietary TGA analysis suite with TG/DTG curve fitting, Excel export, PDF report generation, thermal calibration correction (multi-point), and FDA 21 CFR Part 11–compliant audit trail (optional module) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Balance Range | 0.01 mg–2 g (extendable to 30 g) |
| Balance Resolution | 0.1 µg |
| Isothermal Hold Time | 0–500 min (expandable to 72 h) |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Atmosphere Control | Dual-gas flow regulation with inert/oxidizing/reducing/static/dynamic options |
| Data Interface | USB 2.0 |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA103 |
| Sample Capacity | 1 |
| Instrument Type | General-purpose |
| Temperature Range | Ambient to 1450 °C |
| Balance Sensitivity | 0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Balance Range | 0.1 mg–2 g (extendable to 30 g) |
| Atmosphere Control | Dual-gas manifold with mass flow regulation (inert, oxidative, reductive, static, dynamic) |
| Data Interface | USB |
| Software | Proprietary TGA analysis suite with TG/DTG curve generation, multi-point temperature calibration, Excel export, report printing, and GLP-compliant audit trail |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TGA-103 |
| Price Range | USD 12,500–16,800 (FOB) |
| Operating Environment | High-Temperature |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Ambient to 1350 °C |
| Temperature Accuracy | ±0.01 K |
| Balance Sensitivity | 0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA105 |
| Sample Capacity | 1 |
| Instrument Type | Dedicated TGA System |
| Temperature Range | Ambient to 1550 °C |
| Balance Sensitivity | 0.01 mg (full range: 0.1 mg–2 g, extendable to 30 g) |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time | ≤15 min (from 1000 °C to 100 °C) |
| Data Interface | USB 2.0 |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | DZ-TGA105 |
| Structure Type | Top-Loading (Upper-Positioned) |
| Test Environment | High-Temperature |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Ambient to 1450 °C |
| Temperature Accuracy | ±0.01 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Balance Range | 1 mg–2 g (expandable to 5 g) |
| Balance Resolution | 0.1 µg |
| Isothermal Hold Time | 0–300 min |
| Atmosphere Options | Inert, Oxidizing, Reducing, Static, Dynamic |
| Gas Control | Dual-channel integrated mass flow controllers with adjustable flow rates |
| Data Interface | RS-232 |
| Software | Proprietary TGA analysis suite with automated curve acquisition, kinetic modeling, derivative (DTG) calculation, report generation, and free periodic updates |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-TGA105 |
| Structure Type | Top-loading (upright) |
| Ambient Pressure Operation | Yes |
| Sample Capacity | 1 sample per run |
| Instrument Class | General-purpose TGA |
| Temperature Range | Ambient to 1550 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Baseline Repeatability | High reproducibility |
| Balance Sensitivity | 0.01 mg |
| Balance Dynamic Range | 0.1 mg–2 g (extendable to 30 g) |
| Cooling Time | ≤15 min (from 1000 °C to 100 °C) |
| Data Interface | USB 2.0 |
| Control Processor | STM32 microcontroller |
| ADC Resolution | 48-bit, quad-channel for TG, DSC (if equipped), and temperature signals |
| Display | 7-inch 24-bit color touchscreen |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TGA 101 |
| Sample Capacity | Single-sample |
| Instrument Type | Dedicated TGA System |
| Temperature Range | Ambient to 1550 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Balance Range | 0.1 mg–2 g (extendable to 30 g) |
| Mass Sensitivity | 0.01 mg |
| Cooling Time | ≤15 min (from 1000 °C to 100 °C) |
| Data Interface | Standard USB 2.0 |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TGA 101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1200 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Balance Range | 0.01 mg–2 g (expandable to 30 g) |
| Balance Sensitivity | 0.01 mg |
| Minimum Detection Limit | 0.1 µg |
| Isothermal Hold Duration | 0–500 min (extendable to 72 h) |
| Atmosphere Control | Dual-gas inlet with integrated mass flow meters |
| Display | 7-inch Chinese-language LCD |
| Data Interface | Standard USB |
| Software | Proprietary TGA analysis suite with TG/DTG curve processing, Excel export, PDF report generation, temperature multi-point calibration, and free version upgrades |
| Power Supply | AC 220 V, 50 Hz (customizable) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TG 309 Libra Classic |
| Temperature Range | 10 °C to 1025 °C |
| Temperature Accuracy | ±0.15 K |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TG 309 Libra Select |
| Temperature Range | 10 °C to 1025/1100 °C |
| Temperature Accuracy | ±0.15 K |
| Heating/Cooling Rate | 0–200 K/min |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TG 309 Libra Supreme |
| Temperature Range | 10 °C to 1100 °C |
| Temperature Accuracy | ±0.15 K |
| Heating/Cooling Rate | 0–200 K/min |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TG209F1 Libra |
| Temperature Range | 10 °C to 1100 °C |
| Temperature Accuracy | ±0.2 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0–200 K/min |
| Cooling Time | <15 min (1100 °C → RT) |
| Vacuum Level | 10⁻² mbar |
| Maximum Sample Mass | 2 g |
| Furnace Material | Corrosion-Resistant Ceramic |
| Baseline Correction | BeFlat® Intelligent Baseline Compensation |
| Differential Thermal Signal | c-DTA® Function |
| Optional Automation | ASC Auto-Sampler (192 positions) |
| Optional Module | Temperature-Modulated TGA (TM-TG) |
| Brand | PerkinElmer |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Pyris™ |
| Pricing | Available upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TGA 4000 |
| Temperature Range | Ambient to 1000 °C |
| Balance Capacity | 1500 mg |
| Balance Resolution | 0.2 µg |
| Balance Accuracy/Precision | ±0.02% / ±0.01% |
| Heating Rate | 0.1–200 °C/min |
| Temperature Accuracy/Precision | ±1 °C / ±0.8 °C |
| Sample Pan Volume | 180 µL |
| Atmosphere Options | Static or dynamic, including N₂, Ar, He, CO₂, air, O₂, and other inert or reactive gases |
| Integrated Mass Flow Controller | Standard |
| Optional Autosampler | 45-position |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TGA 8000 |
| Instrument Type | General-Purpose |
| Temperature Range | –20 °C to 1200 °C |
| Heating Rate | 0.1–500 °C/min |
| Gas Control | Dual-path mass flow control (balance purge + sample purge), optional 3-gas mixing module |
| Automation | 48-position autosampler with AccuPik™ compatibility |
| 联用接口 | Integrated heated divert valve and sniffer for FTIR/MS/GC-MS coupling |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TGA-790 |
| Pricing | Upon Request |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 700 °C |
| Balance Sensitivity | ±0.01 µg |
| Temperature Calibration Method | Curie Point Reference |
| Heating/Cooling Rate | 0.01–50 °C/min |
| Mass Range | ±200 mg |
| Mass Resolution | ±0.02 µg |
| Atmosphere Control | Dual Independent Mass Flow Controllers (MFCs), Software-Programmable Gas Switching |
| Crucible Options | Alumina, Platinum |
| Furnace Cooling | Water-Cooled |
| Furnace Liner | Dust-Free Recirculating Cooling System |
| Power Supply | 220 V, 50/60 Hz |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | TG-DTA |
| Heating Rate | Up to 100 °C/min |
| Cooling Rate | 1500 °C → 50 °C in ≤20 min |
| Balance Type | Horizontal Differential Triple-Coil Microbalance |
| Temperature Control | Pre-Compensated PID with Isothermal Overshoot Compensation |
| Calibration | Integrated Temperature & Mass Calibration Functions |
| Power Mode | ECO Standby (30% Energy Reduction) |
| Software | Multi-Station Control (Up to 8 Units), Auto-Diagnosis, Dual Data Backup, Remote Firmware Update |
| Sample Handling | Plug-and-Play Sample Holder, Front-Access Sample Placement, Drop-Tolerant Horizontal Design |
| Optional Accessories | ASC Automatic Sample Changer, TG-DTA/GC-MS Hyphenated Interface |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Rubotherm-DynTHERM |
| Price | Upon Request |
| Brand | Scinco |
|---|---|
| Origin | USA |
| Model | TGA N-1000 / TGA N-1250 / TGA N-1500 |
| Temperature Range | Ambient to 1000°C / 1250°C / 1500°C |
| Balance Sensitivity | 0.1 µg |
| Maximum Sample Mass | 400 mg |
| Heating Rate | 0.1–300 °C/min (N-1000/N-1250) or 0.1–60 °C/min (N-1500) |
| Cooling Method | Water-cooled furnace housing |
| Gas Control | 4-channel automated gas switching valve |
| Simultaneous Analysis Compatibility | FT-IR and Quadrupole Mass Spectrometry (EGA-ready) |
| Sample Capacity | Single-sample vertical configuration |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Labsys Evo-TGA |
| Temperature Range | RT–1600 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.02 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Brand | SETARAM |
|---|---|
| Origin | Beijing, China (Manufactured under France-China joint development) |
| Model | Setline TGA |
| Temperature Range | Ambient to 1100 °C |
| Temperature Accuracy | ±0.3 K |
| Temperature Precision | ±0.1 °C |
| Heating/Cooling Rate | 0.01–50 K/min |
| Dynamic Mass Range | ±20 mg / ±200 mg |
| Balance Sensitivity | 0.0023 µg |
| Mass Accuracy | 0.01% |
| Mass Precision | 0.005% |
| Maximum Sample Mass | 0.3 g |
| Baseline Drift | 25 µg |
| Baseline Repeatability | ±5 µg |
| Atmosphere Options | Inert (N₂, Ar, He) or Oxidizing (air, O₂) |
| Gas Flow Rate | 10–100 mL/min |
| Crucible Materials | Al, Al₂O₃, Pt, Quartz (130–250 µL volume) |
| Cooling | Integrated water-cooled furnace |
| Software | CALISTO 2.0 Thermal Analysis Suite |
| Power Supply | 230 V, 50/60 Hz |
| Dimensions (H×W×D) | 650(850)×400×500 mm |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Setsys EVO |
| Temperature Range | −150 °C to 1750 °C (upgradable to 2400 °C) |
| Heating Rate | 0–100 K/min (full range) |
| Max. TG Sample Capacity | 35 g / 100 g |
| TG Resolution | 0.002 µg / 0.02 µg |
| TG Baseline Repeatability | <10 µg (RT to 1750 °C) |
| DSC Resolution | 1 µW |
| DTA Resolution | 0.4 µW |
| Gas Lines | 3 carrier + 1 auxiliary/reactive gas, controlled via MFCs and solenoid valves |
| Atmosphere Options | inert, oxidative, reductive, steam, corrosive gases |
| Vacuum System | up to 10⁻⁴ mbar (10⁻² torr) |
| EGA Compatibility | MS, FT-IR, GC |
| Optional Modules | Wetsys humidity control, H₂-safe operation kit, corrosive gas kits (SO₂, NH₃, H₂S) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Setsys Evolution |
| Temperature Range | RT to 2400 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.03–0.3 µg |
| Heating/Cooling Rate | 0–100 K/min |
| Atmosphere Options | Inert, Oxidizing, Reducing, Steam, Corrosive Gases |
| Vacuum Capability | Down to 10⁻⁴ mbar |
| Modular Compatibility | DTA, DSC, TMA |
| Gas Mixing | Dual purge + protective gas with mass flow control (50/50 to 1/99 ratio) |
| Humidity Integration | Optional RH-controlled module |
| Evolved Gas Analysis (EGA) | Heated capillary transfer up to 200 °C for FTIR/MS/GC-MS coupling |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | THEMYS DUO (formerly TAG) |
| Temperature Range | Ambient to 1750 °C |
| Temperature Accuracy | ±0.25 K |
| Balance Sensitivity | 0.002 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Maximum Sample Mass | 35 g |
| Baseline Drift | ≤5 µg at 1750 °C |
| Simultaneous Sample Capacity | Multiple |
| Atmosphere Control | 3-channel mass-flow-controlled carrier gas (4–200 mL/min) + 1 auxiliary/reactive gas channel (0.3–16 mL/min) |
| Crucible Options | Al₂O₃, W, graphite, Pt, quartz, Al (55–1500 µL) |
| Sensor Configurations | TGA, DTA, and DSC rods (interchangeable) |
| Dimensions (H×W×D) | 170 × 60 × 55 cm |
| Weight | 145 kg |
| Power Supply | 230 V, 50/60 Hz |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Themys Flash |
| Operating Environment | Ambient Pressure |
| Simultaneous Sample Capacity | Up to 5 |
| Instrument Type | Universal TGA |
| Temperature Range | Room Temperature to 1200 °C |
| Dynamic Weighing Range | ±20 mg, ±200 mg |
| Balance Sensitivity | 0.0023 µg |
| Heating/Cooling Rate | Up to 600 K/min |
| Maximum Sample Mass | 35 g |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Themys |
| Temperature Range | 0–1750 °C (up to 2400 °C in optional configurations) |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.00059 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Maximum Sample Mass | 100 g |
| Baseline Drift | ±3 µg |
| Simultaneous Measurement Capability | TGA, DTA, DSC, STA, TMA, EGA |
| Atmosphere Options | Inert, oxidizing, reducing, corrosive (e.g., H₂, NH₃, SO₂, H₂S), vacuum (primary <5×10⁻² mbar |
| Gas Control | Up to 3 independent mass flow controllers (MFCs), programmable gas switching, heated EGA interfaces (4×, up to 300 °C) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | THEMYS HP |
| Temperature Range | Ambient to 1200 °C |
| Pressure Range | Up to 150 bar |
| Sample Capacity | 35 g |
| Balance Sensitivity | 0.0023 µg |
| Baseline Drift | ±200 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Crucible Volume | 1300 µL |
| Gas Configuration | 3-channel mass flow controlled (2 MFCs standard with auxiliary gas option) |
| Vacuum Capability | <1 mbar (primary), <5×10⁻² mbar (forced) |
| Safety Compliance | EU PED 2014/68/EU, Group 2 gases |
