Thermomechanical Analyzer
Filter
Showing 31–51 of 51 results
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | TMA 4000 SE |
| Temperature Range | –150 to 1700 °C |
| Temperature Accuracy | ±0.1 °C |
| Force Range | 0–4.9 N |
| Displacement Range | ±2.5 mm |
| Dynamic Frequency Range | 0.01–0.5 Hz |
| Measurement Modes | Expansion, Compression, Tension, Penetration, Bending, Dynamic Oscillation, Curing |
| Load Profiles | Constant Force, Sinusoidal (0.01–0.5 Hz), Triangular (0.01–0.2 Hz), Rectangular (0.01–0.1 Hz), Ramp Force (0–0.49 N/min) |
| Deformation Modes | Constant Strain, Strain Ramp (0–50 mm/min), Combined Modes |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TMA 402 F1 Hyperion |
| Temperature Range | −150 °C to 1550 °C (with interchangeable furnaces) |
| Temperature Accuracy | ±0.1 °C |
| Force Range | ±3 N |
| Displacement Range | ±2.5 mm |
| Displacement Resolution | 1.25 nm |
| Force Resolution | 0.01 mN |
| Heating Rate | 0–50 °C/min |
| Vacuum Level | 10⁻⁴ mbar |
| Measurement Atmospheres | Oxidizing, Reducing, Inert, Vacuum |
| Dual-Furnace Capability | Yes |
| Compatible with DSC/STA Furnaces | Yes |
| Dynamic Force Mode | Optional |
| Rate-Controlled Sintering (RCS) | Optional |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TMA 402 F3 Hyperion |
| Temperature Range | -150°C to 1550°C |
| Temperature Accuracy | ±0.1°C |
| Force Range | ±3 N |
| Displacement Range | ±2.5 mm |
| Displacement Resolution | 0.125 nm |
| Force Resolution | 0.01 mN |
| Heating Rate | 0–50°C/min |
| Measurement Atmosphere | Oxidizing, Reducing, Inert, Vacuum (down to 10⁻⁴ mbar) |
| Dual-Furnace Capability | Yes |
| Compatible Furnaces | Interchangeable with DSC and STA systems |
| Optional Modes | Dynamic Force, Rate-Controlled Sintering (RCS), Compression/Indentation/Bending/Tension |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Model | DMA 8000 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | –196 °C to 600 °C (with LN₂ cryogenic cooling) |
| Frequency Range | 0.01–300 Hz |
| Cooling Rate | ≤15 min from ambient to –190 °C |
| Liquid Nitrogen Consumption | ~1 L per typical low-temperature DMA run |
| Sample Modes | Dual/Triple Cantilever, 3-Point Bending, Tension, Compression, Shear, and TMA Mode |
| Humidity Control Range | 10–90 % RH (optional humidity generator) |
| Optical Access | Quartz furnace viewport for in-situ visual monitoring and UV-curable sample testing |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TMA 4000 |
| Pricing | Available Upon Request |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | TMA8310 |
| Sample Capacity | Ø9 mm × 20 mm |
| Heating Rate | Up to 100 °C/min |
| Cooling Rate | From 1000 °C to 50 °C in ≤15 min |
| Temperature Control | Pre-emptive temperature regulation with hold-mode overshoot compensation |
| Calibration | Integrated temperature and dimensional calibration routines |
| Power Mode | ECO standby mode (30% energy reduction) |
| Multi-unit Control | Single PC controls up to 8 units |
| Safety | Dual-stage furnace safety alarm + emergency stop switch |
| Software | Fully integrated thermal analysis suite with auto-diagnosis, dual data backup, and remote firmware update capability |
| Compliance | Designed for GLP/GMP environments |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | TMA8311 |
| Maximum Measurement Temperature | 1500 °C |
| Measurement Principle | Dual-rod Differential Dilatometry |
| Instrument Type | Thermomechanical Analyzer (TMA) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | 96line TMA |
| Instrument Type | Thermomechanical Analyzer |
| Temperature Range | Ambient to 2100 °C |
| Displacement Range | ±2 mm |
| Maximum Force | 1.5 N (electromagnetically controlled) |
| Sample Dimensions | L = 50 mm, Ø = 18 mm (recommended Ø = 15 mm) |
| Displacement Resolution | 1.6 nm RMS |
| Displacement Noise | 10 nm RMS |
| Specific Noise | 0.2 × 10⁻⁶ |
| Probe Types | Al₂O₃ (up to 1750 °C), Graphite (≥1750 °C) |
| Probe Geometry | Spherical-tip compression probe |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Setsys Evo TMA |
| Temperature Range | −150 °C to 2400 °C |
| Heating/Cooling Rate | 0–100 °C/min |
| Displacement Resolution | 0.2 nm |
| Displacement Noise | 5 nm |
| Force Range | 0–3.5 N (controllable) |
| Sample Length | 0–20 mm |
| Sample Diameter | ≤10 mm |
| Maximum Displacement Range | ±2 mm |
| Load Capacity | −150 g to +350 g |
| Measurement Modes | Compression, Penetration, 3-Point Bending, Tensile, Dilatometric, Volumetric Expansion |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | THEMYS TMA |
| Instrument Type | Thermomechanical Analyzer (TMA) |
| Temperature Range | –150 to 2400 °C (configurable up to 2400 °C with high-temp furnace option) |
| Heating/Cooling Rate | 0–100 °C/min |
| Displacement Resolution | 0.2 nm |
| Displacement Noise | 5 nm |
| Force Range | 0–3.5 N (bidirectional, programmable) |
| Sample Length | 0–20 mm |
| Sample Diameter | ≤10 mm |
| Maximum Displacement Range | ±2 mm |
| Load Capacity | –150 to +350 g (equivalent force range) |
| Probe Options | Compression, Penetration, 3-Point Bending, Tensile, Dilatometric, and Volumetric probes |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TMA-60/60H |
| Temperature Range | Ambient to 1000 °C / 1500 °C (optional cryo stage down to −150 °C) |
| Displacement Range | ±5 mm |
| Load Range | ±5 N |
| Sample Dimensions | Ø8 mm × 20 mm (cylindrical) or 5 mm (W) × 1 mm (T) × 20 mm (L) (rectangular) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Compliance | ASTM D4065, ASTM D7028, ISO 6721, ISO 11359, USP <1031> |
| Cooling Range | –100 °C to 600 °C |
| Force Range | 0.1 mN to 18 N |
| Displacement Resolution | 0.1 nm over 25 mm dynamic range |
| Environmental Options | Dual configurable environmental chambers (inert gas, humidity, vacuum) |
| Control Architecture | Non-contact voice-coil motor with continuous force control |
| Bearing System | Low-compliance air bearing |
| Strain Sensing | Direct optical encoder-based strain measurement |
| Software Platform | TRIOS v5.x with 21 CFR Part 11 compliant audit trail and GLP/GMP-ready workflows |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TMA 450 RH |
| Instrument Type | Thermomechanical Analyzer (TMA) |
| Temperature Range | −150 to 1000 °C |
| Temperature Accuracy | ±1 °C |
| Force Range | 0.001–2 N |
| Frequency Range | 0.01–2 Hz |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TMA 450 |
| Temperature Range | −150 to 1000 °C |
| Temperature Accuracy | ±1 °C |
| Force Range | 0.001–2 N |
| Frequency Range | 0.01–2 Hz |
| Displacement Resolution | 15 nm |
| Maximum Sample Length | 26 mm |
| Displacement Range | ±2.5 mm |
| Cooling Option | Mechanical Cooling Accessory (MCA 70) to −70 °C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DuraPulse |
| Instrument Type | Dynamic Mechanical Durability Tester for Cardiovascular Devices |
| Compliance | ISO 5840-1:2021, ISO 5840-2:2021, ISO 5840-3:2021 |
| Test Stations | Configurable as 2-, 4-, or 6-channel modular units |
| Actuation Principle | Electromagnetic linear motor with closed-loop digital servo control |
| Waveform Fidelity | ≤ ±0.5% deviation from target physiological waveform (e.g., sinusoidal, pulsatile, or patient-specific waveforms) |
| Environmental Control | Independent, sealed test chambers with integrated temperature and fluid medium monitoring |
| Warranty | 10-year limited warranty on linear motor assemblies |
| Software Platform | DuraPulse Control Suite v4.x with audit trail and 21 CFR Part 11–compliant user access controls |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | 3200 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA) / Dynamic Mechanical Thermal Analyzer (DMTA) |
| Temperature Range | −150 °C to +315 °C |
| Temperature Accuracy | ±0.3 °C |
| Force Range | ±225 N (optional ±450 N) |
| Displacement Range | ±6.5 mm |
| Frequency Range | 10⁻⁵ Hz to 300 Hz |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | 3330 |
| Instrument Type | Dynamic Mechanical Tester (DMA/DMTA-Compatible Platform) |
| Frequency Range | 0.00001–100 Hz |
| Maximum Dynamic Load | ±3000 N |
| Maximum Dynamic Torque (with optional torsion module) | 28 N·m |
| Configuration Options | Benchtop or Floor-standing |
| Power Requirement | Standard 220 V AC outlet |
| Pneumatic Interface | Compressed air supply required |
| Structural Design | Rigid dual-column beam architecture |
| Vertical Stroke Adjustment | Integrated pneumatic/electric/manual lift mechanism |
| Multi-Axis Capability | Optional torsion motor for axial-torsional coupling |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | 3450 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA) / DMTA |
| Force Range | ±3 kN (standard), ±6 kN (high-load option) |
| Displacement Range | up to ±22 mm |
| Frequency Range | 0.0001 Hz to 200 Hz |
| Temperature Range | –150 °C to 300 °C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | 3500 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Frequency Range | 0.00001–100 Hz |
| Maximum Dynamic Load | 7.5 kN (standard), 15 kN (optional) |
| Dynamic Stroke | 50 mm |
| Cooling | Air-cooled |
| Motor Mounting Options | Upper Crosshead (3510), Base-Mounted (3520), High-Load Configuration (3550) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ElectroForce |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Control | Physiological Saline Bath |
| Loading Mode | Displacement-Controlled Tension-Tension or Compression-Compression |
| Sample Capacity | Multiple Independent Test Stations |
| Cycle Resolution | High-Resolution Linear Encoder-Based Displacement Measurement |
| Compliance | Designed for ISO 14242-1, ASTM F2129, and FDA Guidance for Cardiovascular Implant Fatigue Testing |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Techcomp RJY-1P |
| Instrument Type | Static Thermomechanical Analyzer (TMA) |
| Temperature Range | Ambient to 1000 °C |
| Temperature Accuracy | ±0.1 °C |
| Applied Load Range | Up to 250 g (static force) |
| Displacement Measurement Range | 0–2500 µm |