Used Liquid Chromatograph
Filter
Showing 211–240 of 523 results
| Brand | OtO |
|---|---|
| Origin | Taiwan |
| Model | SW2860-050 |
| Wavelength Range | 900–1700 nm |
| Detector | 256-pixel InGaAs linear array |
| Cooling | Thermoelectric (TE) |
| Usage Duration | 2 years |
| Warranty | ≥3 years |
| Condition | Refurbished, Fully Tested |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 200 |
| Price Range | USD 13,500 – 40,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty | 6 months limited parts and labor |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AAnalyst 200 |
| Instrument Type | Atomic Absorption Spectrometer (Flame & Graphite Furnace Capable) |
| Optical System | True Dual-Beam Stepped Optics with Solid-State Detector |
| Gas Control | Fully Automated Flame Gas Management with Integrated Safety Interlocks |
| Warranty | 6 Months Limited Hardware Warranty |
| Operational Age | 3–4 Years |
| Compliance | Designed to meet ASTM E1941, ISO 8288, and USP <731> requirements for elemental analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AAnalyst 200 / AAnalyst 400 |
| Optical System | Echelle grating double-beam monochromator |
| Wavelength Range | 190–900 nm |
| Spectral Bandpass | 0.15 nm (AAnalyst 200), 0.12 nm (AAnalyst 400) |
| Focal Length | 300 mm |
| Grating Size | 36 × 185 mm, 79 lines/mm |
| Detector | Segmented solid-state detector |
| Lamp Support | Dual power supply for hollow-cathode lamps (HCLs) and electrodeless discharge lamps (EDLs) |
| Safety | Full flame interlock system with gas flow, burner head, drain level, and flame monitoring |
| Operating Temperature | 15–35 °C |
| Relative Humidity | 20–80 % RH (non-condensing) |
| Dimensions | 70 × 65 × 65 cm |
| Weight | 49 kg |
| Power | 100–230 V AC, ±10 %, 50/60 Hz, ≤300 VA |
| Refurbishment Age | 3–4 years |
| Warranty | 6 months |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AAnalyst 400 |
| Operational Age | 4–5 Years |
| Warranty | 6 Months |
| Configuration | Fully Refurbished with PC and AA Software |
| Compliance Status | Fully Tested and Certified per ASTM E1908-22 and ISO/IEC 17025 Calibration Protocols |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AAnalyst 600 |
| Instrument Type | Atomic Absorption Spectrometer |
| Age | 4 years |
| Warranty | 6 months |
| Compliance | ASTM E2173, ISO/IEC 17025-compatible operation |
| Software | WinLab32 v3.52 with instrument control and data reporting modules |
| Lamp Compatibility | Hollow Cathode Lamps (HCLs) and Electrodeless Discharge Lamps (EDLs) |
| Atomization | Flame and Graphite Furnace (with optional GF-3000 upgrade path) |
| Detection Limit (Flame) | Sub-ppb for Cu |
| (GF) | Low-pg range for Cd/Pb |
| Optical System | Double-beam, monochromator with 0.1/0.2/0.5/1.0 nm slit widths |
| Wavelength Range | 190–900 nm |
| Data Output | CSV, XML, PDF reports compliant with GLP audit trails |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AAnalyst 800 |
| Wavelength Range | 189–900 nm |
| Detector | Array-type CCD with integrated low-noise CMOS charge amplifier |
| Slit Width & Height | Motorized automatic selection |
| Lamp Compatibility | Hollow Cathode Lamps (HCL) and Electrodeless Discharge Lamps (EDL) |
| Flame System | Titanium burner head, inert pre-mix chamber, adjustable nebulizer |
| Graphite Furnace | Integrated power supply, IR temperature monitoring with voltage and resistance compensation, STPF platform-coated graphite tubes |
| Sample Introduction | Direct suspension injection for flame and furnace modes |
| Hydride Generation Compatibility | Fully compatible with domestic HG systems (e.g., As, Sb, Se, Hg) |
| FIAS-GF Coupling | Supported for online preconcentration |
| Software | WinLab32 v3.50+ (peak area/height quantitation, lamp auto-identification, method automation) |
| Compliance | Designed to support GLP/GMP workflows |
| Warranty | 6 months limited hardware warranty |
| Operational Age | 4 years |
| Certification | Factory-tested and performance-verified by SpectraLab Scientific |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Altus HPLC A10 |
| Instrument Age | 4–5 years in service (7-year total design life) |
| Warranty | 6 months |
| Configuration | PDA Detector, Solvent & Sample Module, Column Module, LabSolutions-compatible PC, tubing and interconnects included |
| Compliance | Fully tested per ASTM E2653-22 (Standard Guide for Verification of HPLC Systems) |
| Software Environment | Compatible with Waters Empower 3 (via standard ASCII/CSV export) and PerkinElmer’s legacy Turbochrom software |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S/SL |
| Product Category | Chromatography |
| Usage Duration | 4–5 Years |
| Warranty Period | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AutoSystem GC |
| Instrument Type | Gas Chromatograph |
| Year of Manufacture | ~2016–2018 (7-year-old unit) |
| Warranty | 6 months |
| Configuration | Capillary/Split-Splitless Inlet, Programmable Temperature Vaporizing (PTV) Inlet, Cold-On-Column Inlet, Packed Column Inlet, Autosampler, FID/PID/NPD/ECD/TCD/FPD Detectors |
| Compliance | Fully refurbished and functionally validated per ISO/IEC 17025-aligned internal protocol |
| Software | Turbochrom v6.3.2 (or later compatible version) |
| Delivery Status | Ready-to-ship, bench-tested and calibrated |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem ECD |
| Instrument Type | Gas Chromatograph |
| Detector Configuration | Dual Electron Capture Detector (ECD) |
| Age | 4–5 years |
| Warranty | 6 months |
| Condition | Refurbished and Fully Tested |
| Regulatory Compliance | Designed to meet ASTM D5845, EPA Method 8081B/8270, and ISO 10380 requirements for trace halogenated compound analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem GC with NPD & FID |
| Detector Types | Nitrogen-Phosphorus Detector (NPD), Flame Ionization Detector (FID) |
| Instrument Category | Gas Chromatograph (GC) |
| Age | 4–5 years |
| Warranty | 6 months |
| Condition | Refurbished and Fully Tested |
| Compliance | Meets original PerkinElmer factory specifications for GC operation and detector performance |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem TCD |
| Instrument Category | Gas Chromatograph |
| Detector Type | Thermal Conductivity Detector (TCD) |
| Automation | Integrated Autosampler |
| Condition | Refurbished & Fully Tested |
| Operational Age | >7 years |
| Warranty | 6 months |
| Regulatory Compliance | Designed to meet ASTM D1945, ISO 6974, and USP <621> gas chromatography requirements |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem GC |
| Detector Configuration | Dual FID |
| Instrument Category | Gas Chromatograph |
| Age | 5–7 years |
| Warranty | 6 months |
| Condition | Refurbished and Fully Tested |
| Regulatory Compliance | Meets ASTM D3606, ISO 15528, and USP <621> for hydrocarbon and volatile organic compound analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Model 40 Headspace |
| Product Category | Chromatography |
| Operational Age | 5–7 Years |
| Warranty | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PID-ELCD |
| Product Category | Chromatography |
| Operational Age | 5–7 Years |
| Warranty Period | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | AutoSystem XL |
| Instrument Category | Gas Chromatograph |
| Age | 5–7 years |
| Warranty | 6 months |
| Configuration | Refurbished, Fully Tested |
| Regulatory Compliance | Designed to meet ASTM D3606, ISO 6416, and USP <621> chromatographic system suitability requirements |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Autosystem XL |
| Instrument Type | Gas Chromatograph |
| Year of Manufacture | ≥7 years old |
| Warranty | 6 months |
| Regulatory Compliance | Designed to meet ASTM D3606, ISO 10301, and USP <621> chromatographic system suitability requirements |
| Software Compatibility | Native support for TurboChrome v5.x and optional migration to Chromeleon CDS (via hardware interface adapter) |
| Detector Options Supported | FID, TCD, ECD, NPD, FPD, PID |
| Injector Types Supported | Split/splitless capillary inlet, programmable temperature vaporizing (PTV) inlet, cold-on-column (COC) inlet, packed column inlet |
| Automation | Compatible with PerkinElmer AS-100/AS-200 series autosamplers |
| Operating Environment | 15–35 °C, 20–80% RH non-condensing |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Clarus 500 |
| Instrument Type | Gas Chromatograph |
| Age | 4 years |
| Warranty | 6 months |
| Detector Options | FID, ECD, TCD, NPD, FPD, PID |
| Injector Types | Capillary Split/Splitless, PTV, Cold On-Column, Packed Column |
| Automation | TurboMatrix Headspace Autosampler, TurboMatrix Thermal Desorber, Standard Liquid Autosampler |
| Software | TotalChrom™ or Chromeleon™ (version-dependent) |
| Operating Environment | Lab-grade controlled temperature and humidity |
| Compliance | Designed to support ASTM D3612, USP <467>, ISO 11843, EPA Methods 502.2, 524.2, 8240, 8260, and GLP/GMP data integrity requirements |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | Clarus 500 |
| Instrument Type | Gas Chromatograph (GC) |
| Detector Configuration | FID & ECD |
| Age | 4–5 years |
| Warranty | 6 months |
| Condition | Refurbished & Fully Tested |
| Regulatory Compliance | Meets ASTM D3606, ISO 10301, and USP <621> for GC method execution |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Clarus 500 GC/MS |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Detection Principle | Electron Ionization (EI) Mass Spectrometry coupled with Capillary Gas Chromatography |
| Software | TurboMass v8.x |
| Compliance | Designed to meet ASTM D3699, EPA Method 8270D, and ISO 17025 laboratory requirements for trace organic analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | Clarus 500 FID |
| Product Category | Gas Chromatograph |
| Usage Duration | 5–7 years |
| Warranty | 6 months |
| Configuration | Includes FID and autosampler |
| Condition | Refurbished & Fully Tested |
| Regulatory Compliance | Meets ASTM D3606, ISO 10301, and USP <621> for hydrocarbon analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Clarus 600/600T |
| Mass Range | 1–1200 u |
| Scan Rate | Up to 60 scans/sec |
| Detection Limit | <1 pg octafluoronaphthalene (OFN), S/N ≥ 180:1 RMS |
| Column Oven | Fast heating and cooling capability |
| Warranty | 6 months |
| Operational Age | 4 years |
| Instrument Type | Quadrupole GC/MS |
| Compliance | Designed for ASTM, ISO 17025, USP <621>, and GLP/GMP-aligned workflows |
| Software | TurboMass™ v8.x with 21 CFR Part 11-compliant audit trail and electronic signature support |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Clarus 680/600T |
| Mass Range | 1–1200 u |
| Scan Speed | Up to 60 scans/sec |
| Detection Limit | <1 pg octafluoronaphthalene (OFN), S/N ≥ 180:1 RMS |
| Column Oven | Rapid heating and cooling capability |
| Warranty | 6 months |
| Operational Age | 4 years |
| Instrument Type | Quadrupole GC/MS |
| Compliance | Designed for ASTM, ISO 17025, USP <621>, and FDA 21 CFR Part 11–ready software environments |
| Software | TurboMass™ v8.x with GLP/GMP audit trail support |
| Included Components | GC unit (Clarus 680), MS detector (Clarus 600T), autosampler, vacuum pump, dedicated workstation PC, GC/MS interface hardware, and consumables kit |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Elan 5000 |
| Instrument Type | Inductively Coupled Plasma Mass Spectrometer (ICP-MS) |
| Operational Age | 7 years |
| Refurbishment Age | 3–4 years |
| Warranty | 6 months |
| Condition | Fully Tested & Certified by SpectraLab Scientific |
| Compliance | Meets original OEM performance specifications for routine trace elemental analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Elan 6100 |
| Instrument Type | Inductively Coupled Plasma Mass Spectrometer (ICP-MS) |
| Operational Age | 5–7 years |
| Warranty | 6 months |
| Included Accessories | AS-series autosampler, Gilson Minipuls 3 peristaltic pump, Neslab CFT-75 chiller unit |
| Compliance Status | Fully refurbished and functionally validated per ISO/IEC 17025-aligned protocols |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | ELAN DRC II |
| Technique | ICP-MS |
| Resolution | 0.3–3 amu (AutoRes, online adjustable) |
| Linear Dynamic Range | 9 orders of magnitude |
| DRC Reaction Gases | H₂, He, CH₃, NH₃, O₂, N₂O, CO₂ |
| Interference Reduction Capability | >7 orders of magnitude |
| Mass Resolving Power | >150,000 (chemical resolution) |
| Isotopic Ratio Precision (¹⁰⁷Ag/¹⁰⁹Ag) | <0.08% RSD |
| Vacuum System | Dual mechanical pumps + dual turbomolecular pumps (total pumping speed >380 L/min) |
| Warm-up Time | ≤10 min |
| Sample Introduction | GemClean® cross-flow nebulizer + Ryton® Scott-type double-pass spray chamber |
| Cone Design | Largest orifice in industry for high-salt matrix robustness |
| RF Generator | Built-in 40.68 MHz self-tuned solid-state generator |
| Key Technologies | PlasmaLok™ interface, AutoLens™ lens bias optimization, SimulScan™ synchronous scanning, EasyGlide™ torch auto-positioning |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | ELAN DRC-e |
| Instrument Type | ICP-MS |
| Year of Manufacture | ~2005–2010 (typical for DRC-e production cycle) |
| Operational Age | ≤3 years (post-refurbishment) |
| Resolution Range | 0.3–3 amu (electronically tunable in real time) |
| Linear Dynamic Range | 9 orders of magnitude |
| Interference Reduction Factor | >10⁷ for polyatomic interferences (e.g., ⁴⁰Ar¹⁶O⁺ on ⁵⁶Fe⁺, ⁴⁰Ar⁴⁰Ca⁺ on ⁸⁰Se⁺) |
| Warranty | 6 months limited hardware warranty |
| Compliance | Designed to meet ASTM D5673, ISO/IEC 17025 method validation requirements, and supports GLP/GMP data integrity practices when paired with compliant software |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Flexar FX-20 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Maximum Operating Pressure | 18,000 psi |
| Detection Speed | 100 pts/sec (UV/Vis), 200 Hz (PDA) |
| Column Oven Temperature Range | 5–90 °C (Peltier), ±0.2 °C stability |
| Autosampler Injection Volume | 1–100 µL |
| Injection Cycle Time | ≤8 s |
| Solvent Channels | 3 or 5 with integrated degasser |
| Software Platform | Chromera CDS or TotalChrom CDS |
| Regulatory Compliance | 21 CFR Part 11 ready (TotalChrom), GLP/GMP-supporting audit trail and user access control |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Flexar HPLC |
| Configuration | Quaternary Pump, Autosampler, Column Oven with Cooling, UV Detector, Solvent Manager, PC with Chromera Software |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Compliance | Fully refurbished and performance-verified per ISO/IEC 17025-aligned protocols |
| Certifications | Factory-calibrated |
| Software | Chromera CDS v2.5+ (21 CFR Part 11 compliant audit trail enabled) |