| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Flexar |
| Price Range | USD 13,500 – 40,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | 3–4 Years |
| Warranty | 6 Months |
| Detector Type | UV/Vis |
| Pump Configuration | Quaternary Solvent Manager |
| Power Supply | 50/60 Hz |
| Included Modules | Flexar Solvent Manager (5-Channel, N₂ Degasser, P/N N2600580) |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | FLEXAR™ |
| Product Category | Fluorescence Detector (not Mass Spectrometer) |
| Usage Duration | 3–4 years |
| Warranty | 1 year |
| Condition | Refurbished & Fully Tested |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GeneAmp PCR System 9700 |
| Age | 4 years |
| Warranty | 6 months |
| Sample Block | Replaceable 96-well 0.2 mL block |
| Display | Blue LCD graphical display with real-time thermal profile visualization |
| Method Storage | Up to 100 user-defined protocols |
| Compliance | Designed to meet ISO/IEC 17025 laboratory requirements for thermal cycling validation |
| Software Interface | Native ABI-style keypad navigation with soft-touch buttons |
| Certification Status | Fully refurbished and functionally verified per ASTM E2873-22 (Standard Guide for Verification of Thermal Cyclers) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 12 |
| Instrument Type | UV-Visible Spectrophotometer |
| Optical Range | 190–1100 nm |
| Typical Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Complete system with standard cuvette holder, quartz cuvettes, and control software |
| Compliance | Designed to meet ASTM E275, ISO 6223, and USP <857> photometric accuracy requirements |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 2 |
| Product Category | Spectroscopy |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Complete system, fully tested and calibrated |
| Compliance | Meets original factory specifications for optical performance and photometric accuracy |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 20 |
| Product Category | Spectroscopy |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Fully Tested & Certified Refurbished System |
| Compliance | Meets Original OEM Performance Specifications |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 25 |
| Wavelength Range | 190–1100 nm |
| Slit Width | Fixed 1 nm |
| Detector Type | Solid-State Detector (SCD) |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Compliance | ASTM E275, ISO 6425, USP <857> |
| Software Platform | UV WinLab v6.x |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Imported |
| Model | Lambda 25 UV/Vis |
| Spectral Range | 190–1100 nm |
| Optical Resolution | 1 nm (fixed slit) |
| Photometric Accuracy | ±0.005 A (at 0.5 A, NIST-traceable standards) |
| Stray Light | <0.05% T at 220 nm and 340 nm |
| Scan Speed | Up to 2400 nm/min |
| Detector | Silicon photodiode |
| Data Interface | RS-232 or USB (via optional adapter) |
| Software Compatibility | WinUV v4.x (legacy), third-party spectral acquisition via ASCII export |
| Warranty | 6 months limited parts and labor |
| Service History | Refurbished and fully performance-verified per ASTM E275 and ISO 17025-aligned protocols |
| Operational Age | 4–5 years |
| Compliance | Meets requirements for routine QC in pharmaceutical, environmental, and academic laboratories under GLP and ISO/IEC 17025 frameworks |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 2S |
| Product Category | Spectrophotometer |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Fully Tested & Certified Refurbished System |
| Compliance | Meets ASTM E275, ISO 9001 Calibration Traceability Standards |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 35 |
| Wavelength Range | 190–1100 nm |
| Slit Width Options | 0.5, 1, 2, 4 nm |
| Detector Type | Solid-State Detector (SCD) |
| Typical Service Life | 4 years |
| Warranty | 6 months |
| Compliance | ASTM E275, ISO 6233, USP <857> |
| Application Domain | UV-Vis Spectroscopy, Quantitative & Qualitative Analysis, Method Validation, QC/QA in Pharma, Chemical & Academic Labs |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 40 |
| Instrument Type | UV-Visible Spectrophotometer |
| Optical Range | 190–1100 nm |
| Typical Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Complete system with standard cuvette holder, quartz cuvettes, and control software |
| Compliance | Meets ASTM E275, ISO 6223, and USP <857> for photometric accuracy verification |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 4A |
| Product Category | Spectroscopy |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Complete system with standard accessories |
| Compliance | Fully refurbished and performance-verified per ISO/IEC 17025-aligned internal protocols |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 850 |
| Wavelength Range | 175–900 nm |
| Optical Design | Dual-beam, dual-monochromator ratio system |
| Detector | High-sensitivity photomultiplier tube (UV/Vis), PbS detector (NIR) |
| Stray Light | <0.00008% T at 220 nm and 340 nm |
| Photometric Accuracy | ±0.002 A (0–0.5 A), ±0.004 A (0.5–2 A) |
| Baseline Flatness | ±0.0004 A (190–900 nm) |
| Wavelength Accuracy | ±0.08 nm (UV/Vis), ±0.2 nm (NIR) |
| Data Sampling Interval | 0.1–5.0 nm adjustable |
| Software | UV WinLab (standard), ASSP optional modules |
| Warranty | 6 months limited hardware warranty |
| Service History | Fully refurbished and performance-verified by SpectraLab Scientific |
| Operational Age | 4 years |
| Compliance | ASTM E275, ISO 6223, USP <857>, GLP-ready audit trail support in UV WinLab |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda Bio |
| Instrument Type | UV-Visible Spectrophotometer |
| Age | 4 years |
| Warranty | 6 months |
| Configuration | Complete system with standard accessories |
| Compliance | Meets original factory specifications for optical performance and photometric accuracy |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda EZ150 |
| Product Category | Spectroscopy |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Configuration | Fully Tested & Certified Refurbished System |
| Compliance | Meets ASTM E275 and ISO 6233 for photometric accuracy verification |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | LS-45 |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.5 nm |
| Excitation Slit Width | 2.5–15 nm (0.1 nm step) |
| Emission Slit Width | 2.5–20 nm (0.1 nm step) |
| Scan Speed | 10–1500 nm/min (1 nm step) |
| Standard Emission Filters | 290, 350, 390, 430, 515 nm + 1% neutral density filter |
| S/N Ratio | ≥750:1 RMS (water Raman peak at 350 nm excitation), ≥2500:1 RMS (baseline) |
| Lamp Type | Pulsed Xenon |
| Typical Service Life | 4 years |
| Warranty | 6 months |
| Compliance | Fully refurbished to OEM functional specifications |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | NexION 300Q |
| Instrument Type | Inductively Coupled Plasma Mass Spectrometer (ICP-MS) |
| Operational Age | 4 years |
| Warranty | 6 months |
| Compliance | Fully refurbished and performance-verified per ASTM D5673 and ISO/IEC 17025-aligned protocols |
| Software | Syngistix v3.5 or later (FDA 21 CFR Part 11 compliant configuration available) |
| Detection Limit Performance | Sub-femtogram-level sensitivity for key isotopes (e.g., ⁹Be, ¹¹⁵In, ²⁰⁸Pb) under optimized conditions |
| Vacuum System | Dual-stage turbomolecular pumping with integrated cryo-trapping capability |
| Ion Optics | Triple-cone interface + three quadrupole mass filters (Q1: ion/molecule separation |
| Q2 | universal cell reaction/collision zone |
| Q3 | high-resolution mass filtering) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | NexION 300X |
| Product Category | Inductively Coupled Plasma Mass Spectrometer (ICP-MS) |
| Operational Age | 4 years |
| Warranty | 6 months |
| Compliance | Fully tested and certified per ASTM D5673 and ISO/IEC 17025 laboratory protocols |
| Software | Syngistix v3.5 with full audit trail, 21 CFR Part 11–compliant user management |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Optima 2000 DV |
| Instrument Type | ICP Optical Emission Spectrometer |
| Year of Manufacture | ~2016–2017 (based on 7-year age as of 2024) |
| Operational Age | 3–4 years in current configuration |
| Warranty | 6 months limited hardware warranty |
| Compliance | Designed to meet ASTM D1976, ISO 11885, USP <232>/<233>, and EPA Methods 200.7, 200.8, and 6010D requirements |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | Optima 2100 DV |
| Product Category | Spectroscopy |
| Operational Age | 4 years |
| Warranty | 6 months |
| Detection Limit | 0.1–1 ppb for most elements |
| Wavelength Range | 160–900 nm |
| Resolution | <0.003 nm at 200 nm, <0.007 nm at 450 nm |
| Stability | RSD <1% over 1 hour |
| Precision | RSD ≤0.5% |
| RF Frequency | 40.68 MHz |
| Sample Introduction | Dual-view axial/lateral observation with air-cut torch interface and Smart Rinse software |
| Software Platform | WinLab 32 (Windows XP-based) with audit trail, data immutability, and multivariate spectral fitting (MSF) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Imported |
| Model | Optima 3000 DV |
| Product Type | Optical Emission Spectrometer |
| Operational Age | 3–4 years (in current configuration) |
| Total Service Life | ~7 years |
| Warranty | 6 months post-delivery |
| Compliance | Fully refurbished to OEM functional specifications |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Optima 3300 DV |
| Instrument Type | ICP-OES |
| Operational Age | 2–3 years (verified functional history) |
| Warranty | 6 months limited warranty |
| Configuration | Dual-view (radial and axial) optical path |
| Detector | Solid-state CCD array |
| RF Generator | 27.12 MHz solid-state |
| Cooling | Air-cooled torch interface |
| Sample Introduction | Standard nebulizer + cyclonic spray chamber |
| Compliance | Designed to meet ASTM D1976, ISO 11885, EPA Methods 200.7 & 6010D requirements |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Optima 4300 DV |
| Product Category | Spectroscopy |
| Operational Age | 2–3 years (refurbished unit, verified operational history ≤4 years) |
| Warranty | 6 months limited hardware warranty |
| RF Generator | 40 MHz self-oscillating solid-state |
| RF Power Range | 750–1500 W (1 W increments) |
| Detector | Solid-State Charge-Coupled Device (SCD) |
| Short-Term Stability (1 hr) | RSD < 1% |
| Precision (RSD) | ≤ 0.5% |
| Typical Detection Limits | 0.1–1 ppt (ng/L) for most elements |
| Wavelength Range | 160–782 nm |
| Optical Resolution | < 0.006 nm at 200 nm |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Optima 5300 DV |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Detection Principle | ICP-OES |
| Sample Introduction | Pneumatic nebulization with peristaltic pump |
| Observation Mode | Dual-view (axial and radial) |
| RF Generator Frequency | 40.68 MHz |
| Cooling System | External recirculating chiller |
| Software Interface | Fully localized Chinese GUI with automated report generation |
| Compliance | Designed to meet ASTM D1976, ISO 11885, USP <232>/<233>, and EPA Methods 200.7 & 6010D requirements |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Optima 7300DV |
| Instrument Type | Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) |
| Warranty | 1 Year |
| Compliance | ASTM D1976, ISO 11885, USP <232>/<233>, EPA Methods 200.7, 200.8, 6010D |
| Sample Introduction System | GemCone™ Nebulizer with Sapphire Tip & Corrosion-Resistant Polymer Spray Chamber |
| RF Generator | 40.68 MHz Solid-State Self-Oscillating Design |
| Optical System | Dual-Path UV/Vis Spectrometer with Echelle Grating (80 × 160 mm), 75 mm Collimating Mirror |
| Detector | SCD (Solid-State Charge-Detector) Array |
| Detection Limits | <1 ppt for most metals |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | PinAAcle 900Z |
| Configuration | Flame + Graphite Furnace (Dual-Mode) |
| Background Correction | Longitudinal Zeeman Effect |
| Lamp Compatibility | Lumina™ HCL & EDL |
| Software | WinLab32 v3.5+ |
| Warranty | 6 months |
| Operational Age | 3–4 years |
| Compliance | ASTM D1576, ISO 8288, USP <731>, FDA 21 CFR Part 11 (audit trail enabled) |
| Detection Principle | Atomic Absorption Spectroscopy (AAS) with Electrothermal Vaporization (ETV) and Air-Acetylene Flame Atomization |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Pyris 1 TGA |
| Balance Sensitivity | 0.1 µg |
| Balance Repeatability | ±2 mg |
| Balance Accuracy | <0.1% |
| Balance Precision | <0.02% |
| Balance Capacity | 1300 mg |
| Weighing Resolution | 10 ppm |
| Sample Capacity | up to 60 µL (standard furnace), up to 250 µL (high-temperature furnace) |
| Temperature Range | RT–1000 °C (standard), 50–1500 °C (high-temp furnace) |
| Heating/Cooling Rate | 0.1–200 °C/min (standard), 0.1–100 °C/min (high-temp) |
| Temperature Accuracy | ±2 °C (standard), ±5 °C (high-temp) |
| Cooling Time | <15 min (1000 °C → 50 °C, standard), <30 min (1500 °C → 100 °C, high-temp) |
| Atmosphere Options | Static/dynamic, N₂, Ar, He, CO₂, air, O₂, or other inert/reactive gases |
| Temperature Sensor | K-type thermocouple (standard), Pt/Rh (10%) thermocouple (high-temp) |
| Heating Element | Pt/30%Rh with PRTD control |
| Cooling Method | Forced-air cooling |
| Sample Form | Solid, liquid, powder, thin film, or fiber |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | 200 |
| Instrument Age | 4–7 years |
| Warranty | 6 months |
| Configuration | Binary Pump + Autosampler with Sample Cooler + UV Detector + N2000 Chromatography Data System |
| Compliance | Fully Tested and Verified by SpectraLab Scientific |
| Condition | Refurbished & Functionally Certified |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Model | 200A |
| Product Category | Chromatography Detector |
| Type | Fluorescence Detector |
| Age | 4–5 years |
| Warranty | 6 months |
| Condition | Refurbished and Fully Tested |
| Regulatory Compliance | Meets original OEM specifications for operation in GLP-compliant laboratories |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | SIMAA 6000 |
| Optical System | Tetrahedral Echelle Grating (TEP) |
| Wavelength Range | 190–860 nm |
| Spectral Bandwidth | 0.2 nm at 200 nm |
| Grating Grooves | 79 lines/mm |
| Blaze Angle | 63.4° |
| Focal Length | 500 mm |
| Detector | 61-element Zeeman-corrected photodiode array |
| Graphite Furnace | Transversely Heated Graphite Atomizer (THGA) with True Temperature Control (TTC) |
| Max Atomization Temp | 2600 °C (programmable in 10 °C increments) |
| Background Correction | AC Zeeman modulation, ≥0.8 T magnetic field |
| Carrier Gas | Argon, min. inlet pressure 300 kPa, max. flow 600 mL/min |
| Autosampler | PerkinElmer AS-72 (80-position, 0.1–198 µL injection range) |
| Software | WinLab32 for AA |
| Power Requirement | 220 V, 50 Hz, 3-phase, 25 A, 7.7 kVA |
| Instrument Age | 4 years |
| Warranty | 6 months |