Water Quality Analysis
Filter
Showing 2011–2040 of 3714 results
| Brand | LoHua |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LH-T600 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Rapid Digestion Spectrophotometry |
| Wavelengths | 610 nm / 420 nm |
| COD Range | 0–15,000 mg/L |
| Accuracy | ≤5% |
| Repeatability | ≤±3% |
| LOD | 0.5 mg/L |
| Analysis Time per Batch | 20 min |
| Throughput | 30 samples per run |
| Brand | LoHua Tech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | 5B-3B(V11) |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Absorption Photometry (Multi-Wavelength Optical Detection) |
| Wavelength Range | Programmable Multi-Wavelength (e.g., 420 nm, 470 nm, 620 nm, 700 nm) |
| Measurement Range | 0–15,000 mg/L (COD equivalent) |
| Accuracy | ≤ ±5–10% of reading |
| Repeatability | ≤ ±5–10% RSD |
| Detection Limit | 2–15,000 mg/L (method-dependent) |
| Analysis Time | COD < 20 min |
| Batch Capacity | 16 / 25 / 30 samples (user-selectable cuvette rack configuration) |
| Brand | LoHua Tech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Rapid Digestion Spectrophotometry |
| Wavelength Configuration | Multi-Wavelength (610 nm for COD, 420 nm for Ammonia-N) |
| Measurement Range | COD: 0–15,000 mg/L (multi-range auto-segmentation) |
| Ammonia-N | 0–160 mg/L (multi-range auto-segmentation) |
| Accuracy | ≤ ±5% of reading |
| Repeatability | ≤ ±3% RSD |
| Detection Limit | 0.006 mg/L (Ammonia-N) |
| Analysis Time | <20 min (COD), <15 min (Ammonia-N) |
| Batch Capacity | 16 samples per run |
| Data Storage | 12,000 measurement records with timestamp, instrument parameters, and result metadata |
| Calibration | Onboard curve generation via standard solution input and linear/nonlinear regression |
| Connectivity | USB interface + optional infrared wireless module |
| Thermal Control | Adaptive power modulation for 16-position digestion block with over-temperature and time-delay safety cutoff |
| Built-in Thermal Printer | Supports on-demand printout of current/historical results |
| Brand | LoHua Tech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | 5B-6C(V10) |
| Instrument Type | Benchtop Laboratory Water Quality Analyzer |
| Measured Parameters | COD, Ammonia Nitrogen (NH₃-N), Total Phosphorus (TP), Turbidity |
| Data Storage Capacity | 16,000 measurement records |
| Integrated Digestion Unit | Yes, with intelligent heating control, programmable timer, and thermal delay protection |
| Calibration Method | Built-in curve generation and storage using standard reference solutions |
| Output Interface | USB port + infrared data transmission |
| Printing Capability | Integrated thermal printer |
| Optical System | Multi-channel interference-free optical path supporting both cuvette and tube colorimetry |
| Housing | Patented injection-molded enclosure |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | KS2202 |
| Price | USD 2,800 (FOB Qingdao) |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Instrument Type | Online Continuous Analyzer |
| Range | 10–5000 mg/L COD<sub>Cr</sub> |
| Repeatability | ≤3% RSD |
| Accuracy | ±5% of reading (≥100 mg/L) |
| LOD | 15 mg/L |
| Resolution | 1 mg/L |
| Cycle Time | 15 min per analysis |
| Compliance | HJ 377–2019, GB 11914–1989 |
| Auto-Standard Verification | Yes |
| Dual Waste Discharge | Cleaning Solution & Spent Reagent Separately Collected |
| Chloride Tolerance | Up to 35,000 mg/L Cl⁻ (with HgSO₄ masking) |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | LB-8000B |
| Instrument Type | Portable Automatic Water Sampler |
| Sampling Method | Quantitative Sampling |
| Single Sample Volume | 200–1000 mL (adjustable) |
| Sampling Volume Accuracy | ±1% |
| Pump Speed Range | 60–300 rpm (bidirectional) |
| Minimum Sampling Interval | 1 minute |
| Maximum Sampling Depth | 10 m |
| Power Supply | AC 220 V ±10%, 50/60 Hz (standard) |
| Power Consumption | <22 W |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <80% RH |
| Drive Unit Dimensions | 234 × 144 × 140 mm |
| Drive Unit Weight | 3 kg |
| Enclosure Rating | IP31 |
| Display | 3-digit LED (real-time speed) |
| Control Interface | Rotary pulse encoder |
| Memory Function | Power-loss data retention |
| Motor Type | Hybrid stepper motor |
| Pump Mechanism | High-reliability peristaltic pump |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | LB-Q102HB |
| Instrument Type | Portable |
| Detection Method | ISO 6703-2 / HJ 484–2009 (Isonicotinic Acid–Barbituric Acid Spectrophotometric Method) |
| Measurement Range | 0–1 mg/L CN⁻ |
| LOD | 0.004 mg/L |
| Measurement Time | 15–30 min |
| Accuracy | ±5% |
| Repeatability | ≤±5% |
| Optical Stability | ≤±0.001 A/20 min |
| Light Source | Imported Cold LED (100,000 h lifetime) |
| Cuvette Type | Integrated Digestion–Colorimetric Tube |
| Data Storage | 4,000 records + 96 customizable calibration curves |
| Connectivity | USB, LAN, Bluetooth (optional) |
| Display | Backlit LCD (Chinese/English switchable) |
| Power | Rechargeable 5000 mAh Li-ion battery (5 V, 0.3 W) |
| Dimensions | 240 × 95 × 80 mm |
| Weight | 0.5 kg |
| Operating Temp. | 5–40 °C |
| Operating Humidity | ≤85% RH (non-condensing) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | ET99700 |
| Stirring Positions | 4 |
| Speed Range | 10–150 rpm, continuously variable |
| Speed Accuracy | ±10 rpm |
| Operating Temperature | 10–45 °C |
| Power Supply | 220 V / 60 Hz |
| Dimensions | 230 × 245 × 325 mm |
| Weight | ~6.9 kg |
| Compliance | CE Marked |
| Standard Configuration | ET99700 unit, carrying case, user manual, warranty card (Chinese) |
| Note | 1500 mL low-temperature and high-temperature beakers (for ET99710) sold separately |
| Brand | Rikari Kagaku |
|---|---|
| Origin | Japan |
| Model | LQ-5Z Multi |
| Measurement Principle | Potentiometric Electrode Method |
| Analyte Range | THAM 0–5% w/w, NaOH 0–3% w/w, Na₂CO₃ 0–10% w/w, NH₃·H₂O 0–2% w/w |
| Sample Temperature Range | 0.0–40.0 °C |
| Calibration | Single-point zero calibration |
| Temperature Compensation | Automatic (NTC-based) |
| Enclosure Rating | IP66 |
| Power Supply | 3× LR03 (AAA) alkaline batteries |
| Auto-power-off | Yes |
| Electrode Type | 4C-series combination electrode |
| Electrode Cable Length | 1 m |
| Instrument Dimensions (H×W×D) | 38 × 75 × 180 mm |
| Electrode Dimensions (Ø × L) | 17 × 180 mm |
| Weight | Instrument ≈ 300 g, Electrode ≈ 50 g |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (PRC) |
| Model | LQ-5Z |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LQ-5Z-Multi |
| Pricing | Available Upon Request |
| Measurement Principle | Electrode-Based (Grab Sampling) |
| Measurement Range | TMAH: 0.00–5.0% / 0.0–50.0 g/L |
| NaOH | 0.00–3.00% / 0.0–30.0 g/L |
| Na₂CO₃ | 0.0–10.0% / 0–100 g/L |
| NH₃ | 0.0–2.00% / 0.0–20.0 g/L |
| H₂SO₄ | 0.0–2.00% / 0.0–20.0 g/L |
| HNO₃ | 0.0–2.00% / 0.0–20.0 g/L |
| Sample Temperature | 0.0–40.0 °C |
| Accuracy | ±5% FS |
| Calibration | Zero and Span Calibration |
| Temperature Compensation | Automatic |
| Enclosure Rating | IP66 |
| Power Supply | 3×AAA batteries with auto power-off |
| Electrode Type | 4C-type, 1 m standard cable |
| Dimensions (Instrument) | 75(W)×180(D)×38(H) mm |
| Electrode Dimensions | φ17×180(L) mm |
| Weight (Instrument) | ~300 g |
| Weight (Electrode) | ~50 g |
| Standard Kit | Analyzer with batteries, 4C electrode, user manual, certificate of conformity |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LTX Unique |
| Price Range | USD 55,000 – 69,000 (FOB) |
| Measurement Principle | Combustion-Coulometric Titration |
| Measurement Range | 0.1–200 µg Cl⁻ per sample |
| Accuracy | Better than ±1.5% (for 10–50 µg Cl⁻ or S) |
| Repeatability | <1% RSD |
| Detection Limit | 0.1–200 µg Cl⁻ |
| Resolution | 0.01 µg Cl⁻ |
| AOX/TX/EOX/POX Quantification Range | 0.1–320 mg Cl⁻ (absolute) |
| Analysis Time | 3–6 min per sample |
| Electrolytic Signal Resolution | 5 mV |
| Titration Current Range | 0–2000 µA |
| Electrolyte Volume | 5–35 mL |
| Software | ENGINE XS v5.2 |
| Max. Liquid Sample Volume | 100 mL (AOX/POX) |
| Max. Solid Sample Mass | 5 g |
| Dual-Furnace System | High-Temperature Combustion Furnace (up to 1200 °C |
| Power Supply | 230 V / 50 Hz, max. 1000 W (6 A) |
| Dimensions (L×W×H) | 1070 × 360 × 385 mm |
| Standard Configuration | Main analyzer unit with dual-furnace module, coulometric titration cell, integrated gas purification system, and ENGINE XS software suite |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory-Grade |
| Model | LIC100 |
| Measurement Principle | Rapid Digestion–Spectrophotometric Method (HJ/T 399–2007) |
| Measurement Range | 4–10,000 mg/L COD (segmented auto-ranging) |
| Sample Throughput | 16 samples per batch |
| Calibration | Onboard Auto-Standardization |
| Connectivity | Wi-Fi, Bluetooth, USB, Cloud API, WeChat Mini-Program Integration |
| Display | 7-inch Capacitive Touchscreen |
| Compliance | HJ/T 399–2007, ISO 6060, ASTM D1252–22 (Method B) |
| Brand | Yoke (Shanghai Youke Instrument Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Benchtop Laboratory Water Quality Analyzer |
| Detection Parameters | COD, Total Phosphorus (TP), Total Nitrogen (TN), Ammonia-Nitrogen (NH₃-N) |
| Measurement Principle | Spectrophotometric Analysis with Integrated Auto-Digestion |
| Display | 7-inch Capacitive Touchscreen |
| COD Range | 4–10,000 mg/L (segmented) |
| NH₃-N Range | 0–100 mg/L (segmented) |
| TN Range | 0–50 mg/L (segmented) |
| TP Range | 0–20 mg/L (segmented) |
| Compliance | GB/T 11914–1989, HJ 399–2007, HJ 535–2009, HJ 636–2012, HJ 670–2013 |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic (China) |
| Model | M907 |
| Instrument Type | Benchtop |
| Ion Capability | Multi-ion |
| Pricing | Upon Request |
| IP Rating | IP54 |
| Display | 7-inch Color Touchscreen |
| Accuracy Class | 0.01 Grade |
| pH/pX Range | −2.00 to 20.00 |
| mV Range | −1999.9 to +1999.9 mV |
| pH/pX Resolution | 0.01 / 0.1 |
| mV Resolution | 0.1 mV |
| Temperature Compensation | Integrated High-Stability Temperature Electrode (Auto-Recognition & Manual Input) |
| Endpoint Detection | Configurable Stability Criteria |
| Measurement Modes | Direct Concentration, Standard Addition, Sample Addition, Gran Plot |
| Units | mg/L, g/L, mol/L, pX |
| Calibration Logging | Automatic Electrode History & Expiry Alert |
| GLP Compliance | Full Audit Trail, User ID, Timestamp, Method Storage |
| Connectivity | USB Host (U-disk), RS232/USB-C for Printer & PC Sync |
| Stirring | Built-in Magnetic Stirrer |
| Enclosure Protection | IP54 (Dust & Splash Resistant) |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AKMC-1 |
| Price Range | USD 13,500 – 40,500 |
| Measurement Principle | Potentiometric Titration |
| Detection Range | 0.25–250 ppm (as CaCO₃) |
| Sampling Frequency | 1–4 times/hour |
| Operating Temperature | +10 to +35 °C |
| Relative Humidity (at +25 °C) | <80% |
| Sample Pressure | 0.1–10 atm |
| Sample Temperature | +5 to +40 °C |
| Power Supply | 110/220 VAC, 50/60 Hz |
| Power Consumption | 100 W |
| Dimensions | 300 × 400 × 150 mm |
| Weight | 20 kg |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | CRAB |
| Type | Online Oil Film Monitoring System |
| Measurement Range | 0–111 mg/L (as mineral oil, typical calibration) |
| Detection Limit | 0.2 mg/L |
| Accuracy | ±1 mg/L |
| Resolution | 0.1 mg/L |
| Measurement Frequency | 1 Hz |
| Minimum Detectable Oil Film Thickness | ≥0.5 µm |
| Maximum Sensor-to-Water Distance | 25 m |
| Maximum Communication Distance (RS485) | 300 m |
| Operating Temperature | −10 to +50 °C |
| Relative Humidity | Up to 100% |
| Power Supply | 187–242 VAC, 50 Hz |
| Power Consumption | 20 W |
| Dimensions | 160 × 160 × 110 mm |
| Weight | 2 kg |
| Optical Field Tilt Tolerance | ±20° |
| Communication Interfaces | RS232, RS485 |
| Alarm Output | Relay + Visual/Audible Alert |
| Mounting Options | Fixed, pendant, angled, or UAV-integrated |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | FLUORAT-02 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Detection Methods | Fluorometry, Photometry, Chemiluminescence |
| Measured Parameters | Oil in Water, Volatile Phenols, Anionic Surfactants, COD, Turbidity, Cyanide, Uranium, Vanadium, Molybdenum, Nickel, Manganese, Chromium |
| Spectral Range | 250–900 nm |
| Cuvette Pathlengths | 10, 20, and 40 mm |
| Power Supply | 200–240 VAC, 50 Hz |
| Dimensions | 305 × 320 × 110 mm |
| Weight | 6.5 kg |
| Power Consumption | 36 W |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | Fluorat-02-5M |
| Instrument Type | Portable |
| Measurement Principle | UV Spectrophotometry & Fluorescence Detection |
| Detection Limit | 0.2 mg/L |
| Accuracy | ±1% |
| Resolution | 0.01 mg/L |
| Measurement Frequency | 2 samples/min |
| Spectral Range | 250–900 nm |
| Cuvette Pathlengths | 10, 20, and 40 mm |
| Power Supply | 200–240 VAC, 50 Hz |
| Dimensions | 305 × 320 × 110 mm |
| Weight | 6.5 kg |
| Power Consumption | 36 W |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | Fluorat-AE-2 |
| Instrument Type | Online |
| Measurement Principle | UV Fluorescence with Patented Signal Separation Technology |
| Measurement Range | 0.001–500 mg/L |
| Detection Limit | 0.01 mg/L |
| Accuracy | <2% |
| Resolution | 0.1 mg/L |
| Measurement Frequency | 8 samples/hour |
| Sample Input | Up to 10 parallel aqueous streams |
| Power Supply | 187–242 VAC, 50 ±1 Hz / 12 VDC |
| Power Consumption | 100 W |
| Dimensions | 500 × 660 × 200 mm |
| Weight | 50 kg |
| Brand | LUMEX |
|---|---|
| Model | FLUORAT® AA-2 |
| Origin | Russia |
| Detection Range | 0.04–2 mg/L Al |
| Operating Temperature | +5 to +50 °C |
| Sample Flow Pressure | 0.1–10 atm |
| Cycle Time | 10–30 min |
| Output Interfaces | RS-485, RS-232, 4–20 mA (0–20 mA) |
| Power Supply | 187–242 V, 50 Hz ±1%, 12 V DC |
| Power Consumption | 100 W |
| Dimensions | 600 × 600 × 250 mm |
| Weight | ≤ 50 kg |
| MTBF | ≥ 10,000 h |
| IP Rating | Dust-protected and splash-resistant |
| Compliance | PND F 14.1:2.4.181-02, PND F 14.1:4.1.1255-03 |
| Brand | LUMEX |
|---|---|
| Model | RA-915WM |
| Principle | High-Temperature Thermal Decomposition Coupled with Zeeman Atomic Absorption Detection |
| Detection Limit | 0.3 µg/L |
| Measurement Range | 0–200 µg/L |
| Analysis Frequency | Once every 0.5–3 hours |
| Calibration | Fully Automatic |
| Baseline Verification | Fully Automatic |
| Max. Dissolved Solids Tolerance | 1000 mg/L |
| Communication Interfaces | RS-232/485, LAN, Isolated 4–20 mA |
| Protocols | Modbus, GESYTEC |
| Output Relays | Open/Closed |
| Operating Temperature | 5–40 °C |
| Atmospheric Pressure Range | 84–106.7 kPa |
| Relative Humidity | <98% at +35 °C |
| Power Supply | 110/240 VAC, 50/60 Hz |
| Dimensions (L×W×H) | 1000 × 400 × 2000 mm |
| Brand | ZHUOCHI |
|---|---|
| Origin | Zhejiang, China |
| Model | SK3-2.5-13 Complete System |
| Type | Laboratory Benchtop Tube Furnace |
| Temperature Range | 100–1300 °C |
| Temperature Stability | ±1 °C |
| Display Resolution | 1 °C |
| Furnace Chamber Dimensions | φ22 mm × 380 mm |
| Heating Zone Length | 280 mm |
| Max Ramp Rate | ≤50 °C/min (adjustable) |
| Power Rating | 2.5 kW |
| Supply | 220 V, 50 Hz |
| Weight | ~22 kg |
| Control System | LTDE Programmable PID Controller with SSR Output, Dual-Stage Over-Temperature Protection |
| Thermal Insulation | High-Efficiency Ceramic Fiber Blanket |
| Heating Element | Oxidation-Resistant High-Temperature Resistance Wire |
| Thermocouple Type | S-Type (Platinum-Rhodium/Platinum) |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Model | SK3-2.5-13 |
| Type | Laboratory Benchtop Tube Furnace System |
| Temperature Range | 100–1300 °C |
| Temperature Uniformity | ±1 °C |
| Heating Zone Length | 280 mm |
| Tube ID Compatibility | φ22 mm |
| Max Ramp Rate | 50 °C/min (adjustable) |
| Power Rating | 2.5 kW |
| Supply | 220 V, 50 Hz |
| Weight | ~22 kg |
| Compliance | Designed for LYT 1255–1999 (Forestry Industry Standard of the People’s Republic of China: Determination of Total Sulfur in Soils by High-Temperature Combustion–Infrared Absorption Method) |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Type | Laboratory Benchtop Combustion-Based Total Sulfur Analyzer |
| Model | LYT 1255-1999 compliant SK3-2.5-13 |
| Temperature Range | 100–1300 °C |
| Temperature Stability | ±1 °C |
| Furnace Tube ID | φ22 mm |
| Heating Zone Length | 280 mm |
| Max Ramp Rate | ≤50 °C/min (adjustable) |
| Power | 2.5 kW |
| Voltage/Frequency | 220 V, 50 Hz |
| Weight | ~22 kg |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M90S |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Principles | Photometric (Colorimetric), Ion-Selective Electrode (ISE), and Specialized High-Purity Water Analysis Modules |
| Brand | Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | BioFix Lumi-10 |
| Instrument Type | Laboratory |
| Biological Agent | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) |
| Operating Temperature | 18–25 °C |
| Reagent Storage & Assay Temperature | 20–25 °C |
| Coefficient of Variation (CV) | ≤5% (RSD) |
| Batch Capacity | 10 samples per run |
| Assay Duration | 30 minutes per batch |
| Detection Principle | Bioluminescence Inhibition/Enhancement |
| Photomultiplier Detector | Ultrafast Single-Photon Counter |
| Wavelength Range | 380–630 nm |
| Light Intensity Range | 0–120,000,000 photons/s |
| Detection Limit | 1 RLU |
| Display | Backlit monochrome LCD (128 × 64 pixels) |
| Data Storage | 2000 test records |
| Environmental Operating Range | 15–30 °C, 10–90% RH (non-condensing) |
| Power Supply | Rechargeable battery or AC adapter (230 V/50 Hz or 115 V/60 Hz) |
| Dimensions | 170 × 150 × 280 mm |
| Weight | 2.0 kg (including battery) |
| Compliance | EN ISO 11348-1/2/3, CE marked per 2006/95/EC (LVD) and 2004/108/EC (EMC) |
| Brand | Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | Lumi-10 |
| Detector | Ultra-high-speed single-photon-counting photomultiplier tube (PMT) |
| Wavelength Range | 380–630 nm |
| Display | LED, 128 × 64 pixels |
| Data Storage Capacity | 2,000 measurements |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 10–90 % RH (non-condensing) |
| Power Supply | 3 × rechargeable Ni-Cd batteries or AC adapter (230 V/50 Hz or 115 V/60 Hz) |
| Dimensions (H×W×D) | 170 × 150 × 280 mm |
| Weight | 2.0 kg (including batteries) |
| Dynamic Range | >6 decades |
| Interface | RS-232 serial port |
| Preloaded Assay Templates | 6 |
| Language Options | English and German |
| Security | Password-protected user access |
| Compliance | EN ISO 11348-3, Directive 73/23/EEC (Low Voltage), Directive 89/336/EEC (EMC, incl. 92/31/EEC amendment) |
| Brand | Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | BioFix® Lumi-10 |
| Instrument Type | Portable |
| Biological Agent | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria |
| Operating Temperature Range | 15–30 °C (recommended), functional range: 0–40 °C |
| Reagent Storage & Use Temperature | 0–40 °C |
| Coefficient of Variation (CV) | <10% |
| Photon Detection Speed | 5,000 photons per 0.1 s |
| Assay Duration | Default 10 s (adjustable from 0.5–20 s) |
| Detector | Fast single-photon-counting photomultiplier tube (PMT) |
| Wavelength Sensitivity | 380–630 nm |
| Display | LED, 128 × 64 pixels |
| Data Storage Capacity | 2,000 measurement records |
| Power Supply | 3× rechargeable Ni-Cd batteries or AC adapter (230 V/50 Hz or 115 V/60 Hz) |
| Dimensions (H×W×D) | 170 × 150 × 280 mm |
| Weight | 2.0 kg (including batteries) |
| Compliance | Low Voltage Directive 73/23/EEC, EMC Directive 89/336/EEC (incl. amendment 92/31/EEC) |
| Brand | Macherey-Nagel |
|---|---|
| Origin | Germany |
| Model | Vario mini |
| Digestion Method | Rapid Digestion |
| Heating Module | Single Block Heater |
| Batch Capacity | 6 samples |
| Temperature Range | 70–160 °C |
| Temperature Accuracy | ±1 °C |
| Sample Vessel Capacity | 60 mL |
| Timer Accuracy | ±1 min |
| Display | Graphical LCD (124 × 64 px) |
| Preset Temperatures | 70, 100, 120, 148, 150, 160 °C |
| Temperature Stability | ±1 °C (compliant with DIN, EN, ISO, and EPA standards) |
| Ramp Time | ≤25 min (20 °C → 160 °C at ambient 20 °C) |
| Digestion Durations | 30, 60, 120 min selectable |
| Safety Features | Lockable hinged safety lid, overheat protection |
| Interface | Mini-USB |
| Calibration Support | NANOCOLOR USB T-Set included for automated temperature verification and traceable calibration |
| Power Supply | 12 V DC, 5 A |
| Power Consumption | 60 W |
| Dimensions (W×D×H) | 105 × 125 × 170 mm |
| Weight | 0.67 kg (without power adapter) |
| Operating Environment | 10–40 °C, ≤80% RH (non-condensing) |
| Certification | CE |
| Warranty | 1 year |