Water Quality Analysis
Filter
Showing 2101–2130 of 3714 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 450TOC |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Measurement |
| Oxidation Method | UV Photolysis (185 nm) |
| Measurement Range | 0.05 – 1000 ppb C (μg C/L) |
| Accuracy | ±0.1 ppb C for TOC < 2.0 ppb |
| Resolution | 0.001 ppb C (μg C/L) |
| Detection Limit | 0.025 ppb C |
| Repeatability | ±0.05 ppb C (< 5 ppb), ±1.0% (> 5 ppb) |
| Sample Temperature | 0–70 °C |
| Particle Size Limit | < 100 µm |
| Conductivity Requirement | ≥0.5 MΩ·cm (≤2 µS/cm) |
| pH Limit | < 7.5 |
| Flow Rate | 20 mL/min |
| Inlet Pressure | 4–85 psig (0.3–5.8 bar) |
| Dimensions | 334 × 185 × 324 mm |
| Weight (with base) | 7.0 kg |
| Enclosure Material | UL 94 V-0 Flame-Retardant Polystyrene |
| Wetted Materials | 316 Stainless Steel, Quartz, PEEK, Titanium, PTFE, Silicone, FFKM, EPDM |
| Environmental Operating Range | 5–50 °C / 5–80% RH (non-condensing) |
| Power | 100–240 VAC, 50/60 Hz, max. 40 W |
| Certifications | CE, cULus |
| Traceability | NIST-traceable conductivity & temperature sensors per ASTM D1125 and D5391 |
| Compliance | ASTM D5173, USP <643>, EP 2.2.44, JP 2.59, ChP 0912 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | 770MAX |
| Input Channels | 6 (up to 16 measured parameters) |
| Sensor Types Supported | 8 (e.g., conductivity/resistivity, pH/ORP, dissolved oxygen, ozone, TOC, flow, temperature, pressure, level) |
| Output Options | 4 or 8 × 0/4–20 mA analog outputs |
| Communication | RS232 serial interface |
| Relay Outputs | 4 (optional) |
| Display | Multi-line scrolling LCD with customizable parameter naming |
| Power Supply | Universal 100–240 VAC, 50–60 Hz |
| Enclosure | 1/4 DIN, IP65-rated with sealed rear cover |
| Calibration Support | NIST-traceable verification via optional 1875 Smart Calibrator |
| Brand | Micro Emission |
|---|---|
| Origin | Japan |
| Model | MH-5000 |
| Instrument Type | Portable |
| Detection Principle | Liquid Electrode Capillary Plasma Optical Emission Spectrometry (LECP-OES) |
| Target Analytes | Multi-element (≥40 metals, including As, Cd, Cr, Cu, Fe, Pb, Mn, Ni, Zn, etc.) |
| Analysis Time | ≤5 s per sample |
| Sample Volume | 40 µL |
| Power Supply | 6 × AA batteries or AC adapter |
| Weight | 1.4 kg (including battery) |
| Dimensions | 20 × 10 × 11 cm |
| Gas Requirement | None |
| Cooling | Air-cooled, no water circulation |
| Exhaust | No dedicated fume hood required |
| Compliance | Designed for field-deployable environmental testing in accordance with EPA Method 200.7–derived protocols and ISO 17294-2:2016 principles |
| Brand | Micro Emission |
|---|---|
| Origin | Japan |
| Model | MH-6000A |
| Instrument Type | Portable |
| Detection Principle | Optical Emission Spectrometry (OES) with Liquid Electrode Capillary Plasma (LECP) Excitation |
| Target Analytes | Multi-element (≥40 metals, including As, Cd, Cr, Cu, Fe, Pb, Zn, Ni, Mn, Al, Si, etc.) |
| Analysis Time | ≤5 s per sample |
| Detection Limit | Sub-ppm to ppm range |
| Power Requirement | 100 W AC/DC |
| Weight | 4.4 kg |
| Dimensions | 31 × 16 × 20 cm |
| Gas-Free Operation | Yes |
| Cooling System | None required |
| Exhaust Ventilation | Not required |
| Sample Introduction | Peristaltic pump |
| Detector Configuration | Dual-detector array (UV–Vis–NIR extended range) |
| Optional Accessory | Sapphire flow cell (for alkaline and high-silica matrices) |
| Brand | microLAN |
|---|---|
| Origin | Netherlands |
| Model | ALGcontrol |
| Measurement Parameters | Chlorophyll a (Chl-a), Dissolved Organic Matter (DOM), Turbidity |
| Wavelengths | 365, 450, 525, 570, 590, 615, 710 nm |
| Chl-a Range | 0–200 µg/L |
| Chl-a Resolution | 0.2 µg/L |
| Turbidity Range | 0–400 NTU |
| Detector | DTGS with 24-bit ADC sampling |
| Interface | LAN, CAN-Bus, RS232, RS485, Modbus TCP/RTU |
| Analog Outputs | 2 × 4–20 mA |
| Power Supply | 24 VDC |
| Power Consumption | 45 W |
| Enclosure Material | Aluminum |
| IP Rating | IP54 (optional IP65) |
| Dimensions (H×W×D) | 450 × 450 × 260 mm |
| Operating Sample Temp. | 10–35 °C |
| Ambient Temp. | 15–30 °C |
| Sample Flow Rate | 2–10 L/h |
| Cleaning System | Automated NaOCl-based (≤0.05% active chlorine) |
| OS | Embedded Linux |
| Software | SQL-based PC software with audit-ready data logging |
| Brand | microLAN |
|---|---|
| Country of Origin | Netherlands |
| Model | BACTcontrol |
| Measurement Principle | Enzymatic Fluorescence Assay |
| Target Analytes | β-Galactosidase (coliforms), β-Glucuronidase (E. coli), Alkaline Phosphatase (total viable biomass) |
| Measurement Cycle | 1–2 h |
| Detection Method | Substrate-specific fluorogenic enzymatic reaction |
| Sample Flow Rate | 3 L/h |
| Sample Temperature Range | 10–35 °C |
| Ambient Operating Temperature | 15–30 °C |
| Power Supply | 220 V / 50 Hz or 110 V / 60 Hz |
| Power Consumption | <100 W |
| Enclosure Rating | IP54 (optional IP65) |
| Dimensions (H×W×D) | 460 × 450 × 321 mm |
| Weight | 25 kg |
| Housing Material | Aluminum |
| Max. Sample Pressure | 0.05 bar |
| Interface | 2× USB 2.0 (Type A), 2× Gigabit Ethernet (RJ45), Modbus TCP/RTU, 2× digital inputs, 2× relay outputs, 1× 4–20 mA analog output |
| Optional | UMTS/ISDN modem slot, dual-sample inlet with auxiliary cleaning module, climate control unit (>30 °C ambient), automated NaOCl-based cleaning system (≤0.05% active chlorine) |
| Brand | microLAN |
|---|---|
| Origin | Netherlands |
| Model | iTOXcontrol |
| Instrument Type | Online |
| Biological Indicator | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) |
| Operating Temperature | 5–40 °C |
| Reagent Temperature Range | 15–30 °C |
| Repeatability | Relative Error ≤5% |
| Sample Throughput | 10 mL/h (4.5 mL per test, 2 tests/h) |
| Measurement Duration | 40 min |
| Enclosure Rating | IP31 |
| Power Supply | 220 VAC, 50 Hz or 110 VAC, 60 Hz |
| Dimensions (D×W×H) | 50×50×110 cm (plus 73 cm with trolley) |
| Weight | 90 kg (excl. optional air conditioning unit: +20 kg) |
| Brand | microLAN |
|---|---|
| Origin | Netherlands |
| Model | TOX mini |
| Instrument Type | Portable |
| Biological Indicator | Aliivibrio fischeri (formerly Vibrio fischeri) |
| Operating Temperature | 15–30 °C |
| Reagent Storage & Use Temperature | 15–30 °C |
| Detection Principle | Bioluminescence Inhibition Assay |
| Compliance | EN ISO 11348-3 |
| Detector | Ultrafast Single-Photon Counting Photomultiplier Tube (PMT) |
| Wavelength Range | 380–630 nm |
| Data Storage Capacity | 2000 measurements |
| Power Supply | Rechargeable 3×Ni-Cd battery or external AC adapter (230 V/50 Hz or 115 V/60 Hz) |
| Dimensions (H×W×D) | 170×150×280 mm |
| Weight | 2.0 kg (with battery) |
| Sample Vessel | Standard 15 mm diameter × 47–75 mm height test tubes |
| Humidity Range | 10–90 % RH (non-condensing) |
| Onboard Templates | 6 preconfigured toxicity test protocols |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TOXmini |
| Instrument Type | Portable |
| Biological Indicator | Aliivibrio fischeri (formerly Vibrio fischeri) |
| Operating Temperature Range | +15 °C to +30 °C |
| Reagent Storage & Handling Temperature | +2 °C to +8 °C |
| Repeatability | ≤15% RSD (Relative Standard Deviation) at 50% inhibition level |
| Batch Capacity | 1–12 samples per run |
| Typical Measurement Time | 15–30 min per sample (ISO 11348-3 compliant) |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Micromac 1000 |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Principle | Colorimetric Flow Analysis (CFA) with Loop Flow Reactor (LFA) |
| Max Parameters per Cycle | 4 |
| Detection Limit | Sub-ppb to ppm range (method-dependent) |
| Sample Volume per Analysis | 20–30 mL |
| Reagent Consumption | < 500 µL per test |
| Dilution Ratio | Up to 1:100 (factory-calibrated) |
| Data Storage Capacity | 400 records (date, time, absorbance, concentration) |
| Output Signals | 4–20 mA (400 Ω load), 0–5 V, RS-232 (RS-485 optional) |
| Power Supply | 12 V DC |
| Power Consumption | 3 W (standby), 10 W (active) |
| Operating Temperature | 5–40 °C |
| IP Rating | IP55 (IP65 optional) |
| Dimensions (L×H×W) | 550 × 350 × 110 mm |
| Weight | 13 kg (excluding reagents) |
| Sample Temp. Range | 10–30 °C |
| Sample Turbidity/Color | No restriction (blank correction applied) |
| pH Range (method-dependent) | 3–12 |
| Reaction Cell Pathlength | 10–50 mm (50 mm for seawater) |
| Detector | Dual-beam silicon photodetector, multi-wavelength LED source |
| Flow System | Integrated peristaltic sampling pump + LFA reactor (10 mL volume) |
| Compliance | EPA, ISO, and DIN standard methods implemented |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MICROMAC 1000 |
| Pricing | Upon Request |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYSTEA Micromac C |
| Pricing | Upon Request |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China (Distributed) |
| Model | SYSTEA Micromac C |
| Measurement Principles | Colorimetric Spectrophotometry (UV-Vis) |
| Analytes | Nitrate-N, Nitrite-N, Ammonia-N, Orthophosphate, Silicate, Sulfate, Total Phosphorus, Total Nitrogen |
| Detection Method | Batch-type Flow-Through Cell with LED-based Photometric Detection |
| Operating Modes | Manual, Cyclic, Triggered, Continuous |
| Communication Interfaces | RS232, RS485, 4–20 mA analog output |
| Optional | Ethernet interface, Pre-treatment module, Dual-waste separation (toxic/non-toxic), Leak detection sensor, Reagent level monitoring |
| Compliance Support | Designed for continuous unattended operation in GLP-aligned environmental monitoring labs |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Micromac C |
| Pricing | Available Upon Request |
| Brand | Micrometrix |
|---|---|
| Origin | USA |
| Model | SCM-1 |
| Measurement Range | −1000 to +1000 mV |
| Output | 4–20 mA, ±10 V, 0–10 V |
| Display | LED, millivolt resolution |
| Flow Rate | 1 L/min (standard), 5 GPM (optional) |
| Inlet/Outlet | 1/2″ barb inlet, 3/4″ barb outlet |
| Response Time | 1 second |
| Accuracy | ±0.1% of full scale |
| Enclosure | NEMA 4X, IP65 |
| Power | 230 VAC |
| Probe Materials | Delrin®, 316 stainless steel, PTFE |
| Sensor Serviceability | Replaceable piston, disposable PTFE sleeve, field-swappable electrodes |
| Communication | Modbus RTU (optional) |
| Alarm Outputs | Dual SPDT relays with adjustable setpoints |
| Zero & Sensitivity Adjustment | Front-panel accessible, continuous analog tuning |
| Diagnostic Indication | Flashing LED status indicator |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SCM-2 |
| Pricing | Upon Request |
| Brand | Microwise |
|---|---|
| Origin | Denmark |
| Model | BallastWISE |
| Portability | Portable |
| Biological Target | Algal and zooplanktonic organisms |
| Operating Temperature | 0–40 °C |
| Reagent Storage Temperature | 0–40 °C |
| Repeatability | ±1% |
| Sample Throughput | Per batch |
| Analysis Time | 5 s |
| Detection Principle | Dual-mode fluorescence imaging + motility-based viability assessment |
| Size Classes Quantified | 10–50 µm and >50 µm |
| Brand | Millipore |
|---|---|
| Origin | Germany |
| Model | Cement Waste Heat Power Generation Water Quality Test Kit |
| Measurement Principle | Visual Colorimetric Analysis (Standardized Reagent-Based Method) |
| Test Parameters | Phosphate (3–120 ppm), Chloride (2 mg/L detection limit |
| Test Frequency | 190–300 determinations per reagent vial |
| Compliance | Designed for routine industrial water monitoring in accordance with ISO 9001-supported QA/QC workflows and aligned with ASTM D511 (chloride), ASTM D5845 (phosphate), and ISO 6059 (hardness) test method principles |
| Brand | Millipore |
|---|---|
| Origin | Germany |
| Model | NOVA 60 |
| Instrument Type | Online Water Quality Analyzer |
| Measurable Parameters | COD, Heavy Metals, Ammonia-Nitrogen (NH₄-N), Cyanide |
| Key Features | Integrated photometric measurement platform with 12-wavelength LED optical system (240–820 nm), 126 pre-programmed methods covering 50 water quality parameters, 1000-test data storage, compatibility with 16 mm tubes and 10/20/50 mm cuvettes, temperature-compensated optics, battery-powered (9 V, 40 h continuous operation) |
| Brand | Starwood |
|---|---|
| Model | ZLFI00001 |
| Membrane Diameter | 47 mm |
| Membrane Pore Size | 0.45 µm |
| Test Pressure | 2.0–2.2 bar (29–32 psi) |
| SDI Calculation Interval | 0–5–15 min |
| Compliance | ASTM D4189-95 |
| Includes | Pressure Regulator, 47 mm Filter Holder, ASTM-Compliant Mixed Cellulose Ester (MCE) Membranes |
| Accessories Required | 500 mL Graduated Cylinder (±5 mL graduation), Stopwatch (±0.2 s resolution) |
| Brand | Millipore |
|---|---|
| Origin | Germany |
| Model | Pharo 100 |
| Wavelength Range | 320–1100 nm |
| Light Source | Tungsten Halogen Lamp |
| Optical System | Stabilized Single-Beam |
| Spectral Bandwidth | 4 nm |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | ±3.3 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Accuracy | ±0.003 A (A < 0.600) |
| Cuvette Compatibility | 16 mm round, 10/20/50 mm square (auto-recognized) |
| Scan Increment | 1 nm |
| Data Storage | 1000 measurement results + 4 MB for spectral/dynamic data |
| Interfaces | 1× USB-A, 1× USB-B, 1× RS-232 |
| IP Rating | IP31 |
| Operating Temperature | +10 °C to +35 °C |
| Dimensions | 404 × 197 × 314 mm (L×H×W) |
| Weight | ~3.7 kg |
| Brand | Millipore |
|---|---|
| Origin | Germany |
| Model | Pharo 300 |
| Wavelength Range | 190–1100 nm |
| Light Source | Xenon flashlamp |
| Optical System | Stabilized single-beam |
| Spectral Bandwidth | 4 nm |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | ±3.3 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Accuracy | ±0.003 A (A < 0.600 A) |
| Scan Increment | 1 nm |
| Cuvette Types | 16 mm round |
| Barcode Recognition | Full support for Spectroquant® pre-filled tubes and reagent sets |
| AQA Levels | AQA 1 (wavelength verification), AQA 2 (system performance verification), AQA 3 (matrix interference screening) |
| Data Storage | 1000 measurement results |
| Interfaces | 1× USB-A, 1× USB-B, 1× RS-232 |
| Display | Backlit graphical LCD |
| Languages | English, German, Spanish, French, Italian, Simplified Chinese |
| IP Rating | IP31 |
| Operating Temperature | +10 °C to +35 °C |
| Dimensions | 404 × 197 × 314 mm (L × H × W) |
| Weight | ~3.7 kg (without battery) |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Model | Aluminum Ion Detector |
| Type | Portable Multi-Ion Analyzer |
| Measurement Sensitivity | 1 ng/Hz @ 10 MHz |
| Channel Configuration | Single-, Dual-, or Multi-Channel Options Available |
| Compliance | Designed for Field-Deployable Water Quality Monitoring per ISO 10523, ASTM D3590, and EPA Method 200.7 (ICP-OES reference correlation) |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Quartz Crystal Microbalance (QCM) with Gold-Plated Fluoride-Specific Sensor Chip |
| Measurement Sensitivity | 1 ng/Hz @ 10 MHz |
| Channel Configuration | Single-, Dual-, or Multi-Channel Options Available |
| Regulatory Compliance | Designed for ISO 10523, ASTM D4192, and EPA Method 300.0–compatible workflows |
| Software Interface | USB-C–enabled embedded firmware with real-time data streaming and CSV export |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPS Endotoxin Detection System |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Impedance Spectroscopy (EIS) with Functionalized Gold-Quartz Microfluidic Sensor Chip |
| Sensitivity | 0.00742 EU/mL |
| Channel Configuration | Single-, Dual-, or Multi-Channel Options Available |
| Compliance | Designed to support USP <85>, EP 2.6.14, and ISO 11737-1 workflows |
| Sample Format | Aqueous liquid samples only |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Data Interface | USB-C & Bluetooth 5.0 |
| Software Platform | MIPS EndoTrack™ v3.2 (Windows/macOS compatible) |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPS Pesticide Detection System |
| Instrument Type | Multi-Ion Analyzer |
| Detection Principle | Electrochemical Impedance Spectroscopy (EIS) with Functionalized Gold-Quartz Microsensor Chips |
| Sample Matrix | Aqueous Solutions |
| Configurations | Single-, Dual-, or Multi-Channel Options Available |
| Integrated Components | Micro-peristaltic Pumps, Multi-Functional Microfluidic Analysis Chamber, Embedded Signal Processing Unit |
| Brand | MN |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 500D |
| Instrument Type | Laboratory & Field-Deployable Water Quality Analyzer |
| Detection Parameters | >100 parameters including heavy metals (e.g., Cr, Cd, Pb, Ni, Cu, Zn), nutrients (NO₃⁻, NO₂⁻, NH₄⁺, PO₄³⁻), organic indicators (COD, TOC, BOD surrogate), turbidity, chlorine species, pH (via optional electrode module), and colorimetric ions (Fe, Mn, Al, SiO₂) |
| Wavelength Range | 340–860 nm (10 fixed-band interference filters at 345/365/436/470/520/540/585/620/690/800 nm) |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 10–12 nm |
| Light Source | Tungsten halogen lamp |
| Detector | Silicon photodiode |
| Photometric Accuracy | ±1% FS |
| Drift Stability | <0.002 Abs/h |
| Sample Holders | 16-mm round cuvettes (NANOCOLOR® certified), plus 10-mm, 20-mm, and 50-mm rectangular cuvettes |
| Data Storage | 500 measurement records with GLP-compliant metadata (date/time, operator ID, method ID, calibration status) |
| Display | Graphic LCD (64 × 128 pixels), backlight, 10-language UI (English, German, French, Spanish, Italian, Portuguese, Dutch, Polish, Czech, Turkish) |
| Connectivity | USB 1.1 + bidirectional RS-232 |
| Power | AC 100–240 V, 50/60 Hz or internal rechargeable Li-ion battery (6 V, 3.2 Ah) |
| Dimensions | 227 × 282 × 105 mm |
| Weight | 2.4 kg |
| Brand | MN |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 91913 |
| Price | Upon Request |
| Display | 2-line LED, 6 mm character height |
| Voltage | 110–230 V~, 50/60 Hz |
| Power Consumption | 125 / 250 VA |
| Dimensions (W × D × H) | 150 × 250 × 140 mm |
| Sample Capacity | 12 positions |
| Predefined Temperatures | 70 / 100 / 120 / 148 / 160 °C |
| Predefined Timings | 1 / 2 h (at lower T), 1 / 2 h (at higher T) |
| User-Defined Temperature Range | 30–160 °C (1 °C increment) |
| User-Defined Time Range | 00:01–66:59 h (1 second increment) |
| Compliance | EN 61326-1:2013 (EMC), Directive 2014/30/EU (EMC), GLP-supporting firmware and interface logging |
| Brand | MN |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioFix Lumi-10 |
| Instrument Type | Portable |
| Biological Agent | Bioluminescent Bacteria (Aliivibrio fischeri) |
| Operating Temperature Range | 0°C to 40°C |
| Reagent Storage & Usage Temperature | 0°C to 40°C |
| Coefficient of Variation (CV) | <10% |
| Photon Detection Rate | 5,000 photons per 0.1 second |
| Default Measurement Duration | 10 seconds (adjustable from 0.5 to 20 seconds) |
| Detector | Fast Single-Photon-Counting Photomultiplier Tube (PMT) |
| Spectral Sensitivity Range | 380–630 nm |
| Display | LED monochrome, 128 × 64 pixels |
| Data Storage Capacity | 2,000 measurement records |
| Relative Humidity Tolerance | 10–90% RH (non-condensing) |
| Recommended Operational Ambient Temperature | 15–30°C |
| Power Supply | 3× rechargeable Ni-Cd batteries or AC adapter (230 V/50 Hz or 115 V/60 Hz) |
| Dimensions (H×W×D) | 170 × 150 × 280 mm |
| Weight | 2.0 kg (including batteries) |
| Compliance | EU Low-Voltage Directive 73/23/EEC, EMC Directive 89/336/EEC (as amended by 92/31/EEC) |
| Brand | Macherey-Nagel (Germany) |
|---|---|
| Origin | Germany |
| Model | PF-3 919342 |
| Instrument Type | Portable |
| Measurement Principle | UV Absorption Spectrophotometry |
| Wavelength | 365 nm |
| Measurement Range | 2–60,000 mg/L COD |
| Repeatability | High precision |
| Detection Limit | Low (optimized for high-sensitivity UV absorption) |
| Measurement Time | <5 seconds per sample |
| Sample Throughput | Single-sample mode |
| Optical System | LED-based photometer with interference filters (365/450/595 nm) |
| Wavelength Accuracy | ±2 nm |
| Bandwidth (FWHM) | 10–12 nm |
| Detector | Silicon photodiode |
| Cuvette Format | 16 mm round tubes |
| Data Storage | 50 measurement records |
| Display | Graphical LCD (64 × 128 pixels) |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Power Supply | 3×AA batteries (alkaline or rechargeable), USB bus power, optional internal rechargeable battery |
| Enclosure Rating | IP68 |
| Dimensions | 170 × 95 × 68 mm |
| Weight | 0.5 kg |
| Compliance | CE-marked |
| Warranty | 12 months |