- All
- Favorite
- Popular
- Most rated
| Brand | CorrTest |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | CS310X |
| Price Range | USD 14,000–28,000 |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±200 mA (8-channel mode) / ±500 mA (4-channel mode) |
| Current Accuracy | 0.1% of full-scale reading |
| Potential Accuracy | 0.1% of full-scale reading ±1 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 mHz to 1 MHz |
| Input Impedance (Reference Electrode) | 10¹² Ω |
| Channel Isolation Resistance | >100 MΩ |
| Data Acquisition | 16-bit @ 1 MHz, 20-bit @ 1 kHz |
| ADC Resolution | 16-bit DAC with 1 ms settling time |
| Low-Pass Filter | 8 programmable stages |
| Communication Interface | Ethernet |
| Brand | CorrTest |
|---|---|
| Model | CS300M |
| Current Range | ±2 A |
| Current Accuracy | ±0.1% of full-scale reading |
| Potential Accuracy | ±0.1% of full-scale reading ±1 mV |
| Potentiostatic Range | ±10 V |
| Potentiodynamic Scan Rate (CV/LSV) | 0.001 mV/s to 10 V/s |
| Current Sensitivity | 1 pA |
| Potential Resolution | 3 mV (<10 Hz), 10 mV (>100 Hz) |
| EIS Frequency Range | Not specified |
| AD Acquisition | 16-bit @ 1 MHz, 20-bit @ 1 kHz |
| DA Resolution | 16-bit |
| Rise Time | <1 ms (<10 mA), <10 ms (<2 A) |
| Reference Electrode Input Impedance | 10¹² Ω |
| Voltage Compliance | ±21 V |
| Communication Interface | USB 2.0 |
| Low-Pass Filter | 8-stage programmable |
| Brand | CorrTest |
|---|---|
| Origin | Hubei, China |
| Model | CS350M |
| Current Range | ±2.0 A |
| Current Accuracy | 0.1% of full-scale reading |
| Potential Accuracy | 0.1% of full-scale reading ±1 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| ADC Resolution | 16-bit @ 1 MHz, 20-bit @ 1 kHz |
| DAC Resolution | 16-bit |
| Input Impedance (Reference Electrode) | 10¹² Ω |
| Minimum Current Sensitivity | 1 pA |
| CV/LSV Scan Rate | 0.001 mV/s to 10 V/s |
| Pulse Width (CA/CC) | 0.0001 s to 65,000 s |
| EIS Signal Amplitude | 1–2500 mV RMS |
| DC Bias Range | –10 V to +10 V |
| Communication Interface | USB 2.0 |
| Low-Pass Filter | 8 programmable bandwidth settings |
| Brand | CorrTest |
|---|---|
| Origin | Hubei, China |
| Model | CS310M |
| Current Range | ±2.0 A |
| Current Accuracy | 0.1% of full-scale reading |
| Potential Accuracy | 0.1% of full-scale reading ±1 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Potential Resolution | 3 mV (<10 Hz), 10 mV (>100 Hz) |
| Current Sensitivity | 1 pA |
| Rise Time | <1 ms (<10 mA), <10 ms (<2 A) |
| Reference Electrode Input Impedance | 10¹² Ω |
| Current Ranges | 2 nA–2 A (10 decades) |
| Compliance Voltage | ±21 V |
| CV/LSV Scan Rate | 0.001 mV/s to 10 V/s |
| CA/CC Pulse Width | 0.0001–65,000 s |
| AD Acquisition | 16-bit @ 1 MHz, 20-bit @ 1 kHz |
| DA Resolution | 16-bit, settling time: 1 µs |
| EIS Signal Generator | Sine/triangle/square wave |
| AC Amplitude | 1–2500 mV RMS |
| DC Bias | −10 to +10 V |
| Bandwidth | 8 programmable settings |
| Interface | USB 2.0 |
| Software | CorrTest CS Studio v4.x with GLP-compliant audit trail, method validation, and CFR Part 11–ready user access control |
| Brand | CorrTest |
|---|---|
| Origin | Hubei, China |
| Model | CS2350M |
| Instrument Type | Dual-Channel Electrochemical Workstation |
| Number of Channels | 2 Independent Potentiostat/Galvanostat Units |
| Current Range | ±1.0 A |
| Current Accuracy | ±0.1% of full-scale reading |
| Potential Accuracy | ±0.1% of full-scale reading ±1 mV |
| Potentiostatic Control Range | ±10 V |
| Electrochemical Impedance Spectroscopy (EIS) Frequency Range | 10 µHz to 1 MHz |
| Input Impedance (Reference Electrode) | 10¹² Ω |
| Current Sensitivity | 1 pA |
| Potential Sensitivity | 3 µV (<10 Hz), 10 µV (>100 Hz) |
| Potentiostat Rise Time | <1 µs (<10 mA), <10 µs (<2 A) |
| Current Ranges | 2 A to 2 nA (10 decades) |
| DA/AD Resolution | 16-bit DAC / 16-bit @ 1 MHz, 20-bit @ 1 kHz ADC |
| Communication Interface | Ethernet |
| Dimensions (W×D×H) | 36.5 × 30.5 × 16 cm |
| Net Weight | 7.5 kg |
| Brand | CorrTest |
|---|---|
| Origin | Hubei, China |
| Model | CS300X |
| Channel Count | 2–8 (configurable) |
| Current Range | ±500 mA (Ch. 1–3), ±200 mA (Ch. 4–8) |
| Current Accuracy | 0.1% of full-scale reading |
| Potential Accuracy | 0.1% of full-scale reading ±1 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Data Acquisition | 16-bit @ 1 MHz, 20-bit @ 1 kHz |
| Input Impedance (Reference) | 10¹² Ω |
| Output Compliance Voltage | ±21 V (expandable to ±200 V) |
| Communication Interface | USB 2.0 / Ethernet |
| Brand | CorrTest |
|---|---|
| Model | CS150M |
| Current Range | ±2.0 A |
| Current Accuracy | 0.1% of full-scale reading |
| Potential Accuracy | 0.1% of full-scale reading ±1 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 115 kHz |
| Potential Resolution | 3 mV (<10 Hz), 10 mV (>100 Hz) |
| Current Sensitivity | 1 pA |
| Rise Time | <1 ms (<10 mA), <10 ms (<2 A) |
| Reference Electrode Input Impedance | 10¹² Ω |
| Current Ranges | 2 nA–2 A (10 decades) |
| Compliance Voltage | ±21 V |
| CV/LSV Scan Rate | 0.001 mV/s–10 V/s |
| CA/CC Pulse Width | 0.0001–65,000 s |
| AD Acquisition | 16-bit @ 1 MHz, 20-bit @ 1 kHz |
| DA Resolution | 16-bit, Settling Time: 1 ms |
| Minimum CV Potential Increment | 0.075 mV |
| SWV Frequency | 0.001–100 kHz |
| DPV/NPV Pulse Width | 0.0001–1000 s |
| Low-Pass Filter | 8-stage programmable |
| Communication Interface | USB 2.0 |
Show next