| Brand | Wyatt |
|---|---|
| Origin | USA |
| Manufacturer | Wyatt Technology Corporation |
| Instrument Type | Differential Refractometer (dRI) |
| Wavelength | 658 nm (LED source) |
| Detection Method | Photodiode Array |
| Cell Volume | 7.4 µL |
| RI Range (Δn) | ±0.0047 RIU |
| Noise Level | <2.0 × 10⁻⁹ RIU |
| Response Time | 0.1–5 s |
| Absolute RI Range | 1.2–1.8 RIU |
| Temperature Stability | <±0.005 °C |
| Max System Pressure | 30 psi |
| Max Flow Cell Pressure | 100 psi |
| Interface | High-Resolution LCD Display |
| Brand | Wyatt |
|---|---|
| Origin | USA |
| Manufacturer | Wyatt Technology Corporation |
| Product Type | Laboratory Laser-Based Dynamic Light Scattering (DLS) Instrument |
| Measurement Range | 0.5–1000 nm |
| Repeatability | <1% |
| Measurement Time per Well | 1–5 s |
| Sample Format | 96-, 384-, or 1536-well microplates |
| Minimum Sample Volume | 4 µL |
| Scattering Angle | 150° |
| Laser Wavelength | 830 nm |
| Laser Power | 0–50 mW (programmable) |
| Minimum Concentration | 0.125 mg/mL |
| Dispersion Method | Wet Dispersion |
| Temperature Control | Ambient (no active thermostating) |
| Software Compliance | FDA 21 CFR Part 11, GLP/GMP-ready audit trail, electronic signature support |
| Brand | Wyatt |
|---|---|
| Origin | USA |
| Manufacturer | Wyatt Technology Corporation |
| Model | ViscoStar |
| Wavelength | 658 nm |
| Detection Principle | Four-Arm Capillary Bridge |
| Flow Rate | 1–3 mL/min |
| Delay Volumes | 4 mL, 12 mL, 27 mL (user-selectable) |
| Cell Volume | 33 µL per bridge arm |
| Operating Temperature Range | 4–60 °C |
| Temperature Stability | < 0.01 °C |
| Cooling Method | Air-cooled Peltier |
| Dimensions (H×W×D) | 168 mm × 357 mm × 595 mm |
| Weight | 11.5 kg |
| Analog Outputs | 2 channels (inlet pressure & differential pressure) |
| Display | Full-color LCD |
| Data Interface | Ethernet |
| Brand | Wyatt |
|---|---|
| Origin | USA |
| Manufacturer | Wyatt Technology Corporation |
| Model | DAWN (SEC-MALS) |
| Instrument Type | Ambient-Temperature GPC/SEC System |
| Pump Flow Range | 0.001–10 mL/min |
| Pump Pressure Range | 0–40 MPa |
| Refractive Index Detector Drift | <1.0 × 10⁻⁷ RIU/h |
| RI Detector Cell Volume | 7 µL |
| UV Detector Wavelength Range | 190–600 nm |
| UV Detector Noise | <0.25 × 10⁻⁵ AU |
| Column Oven Temperature Range | (Ambient −10) to 85 °C |
| Brand | Wyatt |
|---|---|
| Origin | USA |
| Manufacturer | Wyatt Technology Corporation |
| Product Type | Imported Instrument |
| Model | DAWN |
| Price | Upon Request |
| Molecular Weight Range | 200–10⁹ Da |
| Size Range | 10–500 nm |
| Laser Source | 100 mW GaAs linearly polarized laser |
| Wavelength | 658 nm |
| Detector Configuration | 18 angular detectors |
| Power Consumption | 400 W |
| Solvent Compatibility | Aqueous and organic solvents |
| Dimensions (L×W×H) | 58 × 36 × 25 cm |
| Shipping Weight | 23 kg |
| Brand | Wyatt |
|---|---|
| Origin | USA |
| Manufacturer | Wyatt Technology Corporation |
| Product Type | Imported Instrument |
| Model | Calypso II |
| Pricing | Available Upon Request |
| Brand | Wyatt |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DynaPro NanoStar II |
| Price Range | USD 55,000 – 68,000 |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 0.2–1000 nm |
| Measurement Duration | User-Configurable |
| Brand | Wyatt |
|---|---|
| Origin | USA |
| Manufacturer | Wyatt Technology Corporation |
| Type | Plate Reader III |
| Key | DLS & SLS Integration |
| Sample Throughput | 96-well and 384-well microplates |
| Detection Modes | Dynamic Light Scattering (DLS), Static Light Scattering (SLS), Temperature Ramp & Hold |
| Measurable Parameters | Hydrodynamic Radius (Rh), Radius of Gyration (Rg), Molecular Weight (Mw), Aggregation Onset Temperature (Tonset), Melting Temperature (Tm), Aggregation Temperature (Tagg), Diffusion Interaction Parameter (kD), Second Virial Coefficient (A2), B22, Turbidity, Viscosity (relative), Conformational Stability Index, Isothermal/Variable-Temperature Stability Profiles |
| Compliance | ASTM E2490, ISO 22412, USP <788>, FDA 21 CFR Part 11 Ready (with optional audit trail module) |
| Software Platform | Dynamics v8.x with GLP/GMP-compliant data handling |
| Brand | Wyatt Technology |
|---|---|
| Origin | USA |
| Manufacturer | Wyatt Technology Corporation |
| Type | Imported |
| Model | MÖBIUζ™ |
| Pricing | Available Upon Request |
| Brand | Wyatt |
|---|---|
| Origin | USA |
| Manufacturer | Wyatt Technology Corporation |
| Type | GPC/SEC-Compatible MALS Detector |
| Wavelength | 658 nm |
| Detection Method | Single-Beam |
| Light Source | 60 mW GaAs Linearly Polarized Laser |
| Angles | 3 (Low, 90°, High) + 2 Reference Angles |
| Molecular Weight Range | 10³ – 10⁷ Da |
| Size Range (Rg) | 10 – 50 nm |
| Data Interface | Ethernet |
| Display | Full-Color LCD |
| Brand | Wyatt |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DAWN 8 |
| Pricing | Available Upon Request |
| Angular Range | 23°–155° (8 fixed angles) |
| Molecular Weight Range | 10³–10⁷ Da |
| Root-Mean-Square Radius (Rg) Measurement Range | 10–300 nm |
| Laser Source | 50 mW GaAs linearly polarized laser, 658 nm |
| Data Interface | Ethernet |
| Display | Full-color LCD touchscreen |
| Brand | Wyatt Technology |
|---|---|
| Origin | USA |
| Manufacturer | Wyatt Technology Corporation |
| Instrument Compatibility | MALS, DLS, SEC/GPC, Viscometry, RI, UV Detectors |
| Model | ASTRA 7 |
| Compliance | FDA 21 CFR Part 11–Ready, GLP/GMP Support Enabled |
| Data Export Formats | CSV, Excel (.xlsx), PDF, SVG, PNG, XML |
| Operating System | Windows 10/11 (64-bit) |
| Brand | Wyatt |
|---|---|
| Origin | USA |
| Manufacturer | Wyatt Technology Corporation |
| Type | Imported Instrument |
| Model | miniDAWN |
| Instrument Category | Ambient-Temperature GPC/SEC Detector |
| Pump Flow Range | 0.001–10 mL/min |
| Pump Pressure Range | 0–40 MPa |
| RI Detector Drift | <3 × 10⁻⁷ RIU/h |
| RI Detector Cell Volume | 7 µL |
| UV Detector Wavelength Range | 190–600 nm |
| UV Detector Noise | <0.25 × 10⁻⁵ AU |
| Column Oven Temperature Range | Ambient to 85 °C |
| Scattering Angles | 3 (low-angle, 90°, high-angle) |
| Molecular Weight Range | 10³–10⁶ Da |
| Root-Mean-Square Radius (Rg) Range | 10–50 nm |
| Laser Source | 60 mW GaAs linearly polarized laser, 658 nm |
| Data Interface | Ethernet |
| Display | Full-color LCD |
| Brand | Wyatt |
|---|---|
| Origin | USA |
| Manufacturer | Wyatt Technology Corporation |
| Type | Benchtop Laboratory Instrument |
| Measurement Range | 1–80 NTU |
| Operating Temperature Range | −15 °C to +150 °C |
| Sample Volume | As low as 2 µL |
| Integrated Software | DYNAMICS Touch™ and DynaPro® NanoStar® |
| Brand | Wyatt |
|---|---|
| Origin | USA |
| Manufacturer | Wyatt Technology Corporation |
| Instrument Type | Asymmetric Flow Field-Flow Fractionation (AF4) Coupled with Multi-Angle Light Scattering (MALS) |
| Model | AF4-MALS System |
| Compliance | Fully Compatible with ASTM D7980, ISO 22412, USP <788>, and GLP/GMP Data Integrity Requirements |
| Fluid Compatibility | Aqueous and Organic Solvents (e.g., THF, DMF, Chloroform) |
| Separation Range | 1 nm – 10 µm |
| Typical Run Time | 10–30 min |
| Detection Integration | MALS (18-angle), UV-Vis, dRI, DLS, ICP-MS, MALDI-TOF (via fraction collection) |
| Control Interface | PC-driven Motorized Needle Valve, Dual Pressure Monitoring, Real-time LCD Display, Analog/Digital I/O Ports |
| Brand | Wyatt |
|---|---|
| Origin | USA |
| Manufacturer | Wyatt Technology Corp. |
| Type | Asymmetric Flow FFF (AF4) |
| Model | Eclipse AF4 |
| Separation Range | 2 nm – 20 µm |
| Crossflow Rate | 0–8.3 mL/min (up to 10 mL/min total with detector flow) |
| Channel Pressure Limit | 30 bar (auto-shutdown at 33 bar) |
| Spacer Thickness Options | 125, 190, 250, 350, 490 µm |
| Membrane Cutoffs | Regenerated cellulose (10 kDa, 30 kDa) |
| pH Compatibility | 1–14 |
| Materials | PEEK base, aluminum housing with polycarbonate inner membrane, stainless steel frit, Buna-N O-rings (Kalrez® optional for organics) |
| Solvent Compatibility | Aqueous and organic (with glass membrane & Kalrez® seals) |
| Pressure Sensor Range | 0–100 bar |
| LiquiFlow Inlet Flow Measurement | 0–1 mL/min |
| LiquiFlow Crossflow Control/Measurement | 0–8.3 mL/min |