| Brand | XOS |
|---|---|
| Model | Phoebe |
| Instrument Type | Benchtop |
| Excitation Principle | Monochromatic Wavelength-Dispersive XRF |
| Target Element | Phosphorus (P) |
| X-ray Tube Power | 75 W |
| Detection Limit (LOD) | 0.4 ppm (at 600 s) |
| Quantification Range | 0.4 – 3000 ppm |
| Sample Volume | ≤10 mL |
| Sample Containment | Prolene film |
| Measurement Time | 30–900 s (user-selectable) |
| Calibration | Multi-curve storage |
| Motion Components | None |
| Gas/Combustion Required | No |
| Operating Environment | Standard laboratory AC power only |
| Brand | XOS |
|---|---|
| Model | Sindie +Cl |
| Instrument Type | Benchtop WDXRF Spectrometer |
| Excitation | Monochromatic Wavelength-Dispersive XRF (MWDXRF) |
| X-ray Tube Power | 75 W |
| Elements Analyzed | Sulfur (S), Chlorine (Cl) |
| LOD | 0.4 ppm (S), 0.3 ppm (Cl) |
| Quantification Range | 0.4 ppm – 5 wt% (S), 0.3 ppm – 3000 ppm (Cl) |
| Sample Volume | ≤10 mL |
| Sample Membrane | Mylar film |
| Measurement Time | 30–900 s (user-configurable) |
| Detector Configuration | Dual independent solid-state detectors |
| Compliance | ASTM D7039-15, ASTM D2622, ASTM D7536-16, ASTM D4929-19, ISO 20884:2019, NB/SH/T 0842-2017, SH/T 0977-2019, GB 11140-2008 |
| Brand | XOS |
|---|---|
| Model | Sindie R2 |
| Instrument Type | Benchtop |
| Excitation Principle | Monochromatic WDXRF (MWD-XRF) |
| Target Element | Sulfur (S) |
| X-ray Tube Power | 75 W |
| Detection Limit | 0.4 mg/kg @ 300 s |
| Measuring Range | 0.4 mg/kg – 3000 mg/kg and 3000 mg/kg – 10 wt% |
| Sample Volume | ≤10 mL |
| Sample Membrane | Polyethylene (Mylar) |
| Measurement Time | 10–999 s (user-selectable) |
| Display | 10-inch color touchscreen |
| Data Storage Capacity | >50,000 test records |
| Compliance Standards | ASTM D7039-15a(2020), ASTM D2622-21, NB/SH/T 0842-2017, ISO 20884:2019, GB/T 11140-2008 |
| Brand | XOS |
|---|---|
| Model | Clora 2XP |
| Instrument Type | Benchtop |
| Excitation Principle | Monochromatic WDXRF (Single-Wavelength XRF) |
| Target Element | Chlorine (Cl) |
| X-ray Tube Power | 75 W |
| Detection Limit | 0.07 ppm (at 600 s) |
| Quantification Range | 0.07 ppm – 2 wt% |
| Sample Volume | ≤10 mL |
| Sample Membrane | Ethylene Tetrafluoroethylene (ETFE) film |
| Measurement Time | Adjustable from 30 to 900 seconds |
| Calibration | Multi-curve storage with automatic high-sulfur/low-chlorine correction |
| Motion-Free Optics | Dual hyperbolic bent-crystal optics (monochromator + analyzer) |
| Compliance | ASTM D7536-16, ASTM D4929-19 (Method C), SH/T 0977-2019 |
| Brand | XOS |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop |
| Excitation Source | 75 W Low-Power X-ray Tube |
| Analyte Element | Sulfur (S) |
| Detection Principle | Monochromatic Wavelength-Dispersive XRF |
| Compliance | ASTM D7039, ASTM D2622, NB/SH/T 0842, ISO 20884, GB/T 11140 |
| LOD | 0.18 mg/kg @ 300 s |
| Quantification Range | 0.18 mg/kg – 10 wt% (dual-range mode) |
| Sample Volume | ≤10 mL |
| Sample Cell | Accucell™ with Mylar® film |
| Measurement Time | 10–999 s (user-defined) |
| Data Storage | >50,000 test records |
| Display | 10-inch capacitive color touchscreen |
| Moving Parts | None in analyzer core |
| Calibration | Multi-curve storage, infrequent recalibration required |
| Brand | XOS |
|---|---|
| Model | Clora |
| Instrument Type | Benchtop WDXRF Analyzer |
| Excitation | Monochromatic X-ray Beam |
| Target Element | Chlorine (Cl) |
| X-ray Tube Power | 75 W |
| Detection Limit (LOD) | 0.13 ppm |
| Measuring Range | 0.13 ppm – 3000 ppm (standard), up to 4 wt% (optional) |
| Sample Volume | ≤10 mL |
| Measurement Time | 30–900 s (user-configurable) |
| Sample Form | Liquid hydrocarbons, aqueous solutions, solid powders (with AccuCell cup) |
| Compliance | ASTM D7536-16, ASTM D4929-19 (Method C), SH/T 0977-2019 |
| Optical System | Dual Hyperbolic Bent-Crystal Monochromators |
| Detector | High-resolution proportional counter or scintillation detector (configuration-dependent) |
| Calibration | Multi-curve storage, manual high-sulfur/low-chlorine correction |
| Optional Accessories | AccuFlow™ suspension compensation module, AccuCell™ sample cups, automated sample changer |
| Brand | XOS |
|---|---|
| Model | Signal |
| Instrument Type | Benchtop |
| Excitation | Monochromatic WDXRF |
| Target Element | Silicon (Si) |
| X-ray Tube Power | 75 W |
| Detection Limit (LOD) | 0.65 ppm (at 600 s) |
| Measurable Range | 0.65–3000 ppm |
| Sample Volume | ≤10 mL |
| Sample Membrane | Prolene film |
| Measurement Time | 30–900 s (user-configurable) |
| Compliance | ASTM D7757-17, NB/SH/T 0993-2019 |