Empowering Scientific Discovery

Yizhen Analytical Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXOS
ModelPhoebe
Instrument TypeBenchtop
Excitation PrincipleMonochromatic Wavelength-Dispersive XRF
Target ElementPhosphorus (P)
X-ray Tube Power75 W
Detection Limit (LOD)0.4 ppm (at 600 s)
Quantification Range0.4 – 3000 ppm
Sample Volume≤10 mL
Sample ContainmentProlene film
Measurement Time30–900 s (user-selectable)
CalibrationMulti-curve storage
Motion ComponentsNone
Gas/Combustion RequiredNo
Operating EnvironmentStandard laboratory AC power only
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXOS
ModelSindie +Cl
Instrument TypeBenchtop WDXRF Spectrometer
ExcitationMonochromatic Wavelength-Dispersive XRF (MWDXRF)
X-ray Tube Power75 W
Elements AnalyzedSulfur (S), Chlorine (Cl)
LOD0.4 ppm (S), 0.3 ppm (Cl)
Quantification Range0.4 ppm – 5 wt% (S), 0.3 ppm – 3000 ppm (Cl)
Sample Volume≤10 mL
Sample MembraneMylar film
Measurement Time30–900 s (user-configurable)
Detector ConfigurationDual independent solid-state detectors
ComplianceASTM D7039-15, ASTM D2622, ASTM D7536-16, ASTM D4929-19, ISO 20884:2019, NB/SH/T 0842-2017, SH/T 0977-2019, GB 11140-2008
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXOS
ModelSindie R2
Instrument TypeBenchtop
Excitation PrincipleMonochromatic WDXRF (MWD-XRF)
Target ElementSulfur (S)
X-ray Tube Power75 W
Detection Limit0.4 mg/kg @ 300 s
Measuring Range0.4 mg/kg – 3000 mg/kg and 3000 mg/kg – 10 wt%
Sample Volume≤10 mL
Sample MembranePolyethylene (Mylar)
Measurement Time10–999 s (user-selectable)
Display10-inch color touchscreen
Data Storage Capacity>50,000 test records
Compliance StandardsASTM D7039-15a(2020), ASTM D2622-21, NB/SH/T 0842-2017, ISO 20884:2019, GB/T 11140-2008
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXOS
ModelClora 2XP
Instrument TypeBenchtop
Excitation PrincipleMonochromatic WDXRF (Single-Wavelength XRF)
Target ElementChlorine (Cl)
X-ray Tube Power75 W
Detection Limit0.07 ppm (at 600 s)
Quantification Range0.07 ppm – 2 wt%
Sample Volume≤10 mL
Sample MembraneEthylene Tetrafluoroethylene (ETFE) film
Measurement TimeAdjustable from 30 to 900 seconds
CalibrationMulti-curve storage with automatic high-sulfur/low-chlorine correction
Motion-Free OpticsDual hyperbolic bent-crystal optics (monochromator + analyzer)
ComplianceASTM D7536-16, ASTM D4929-19 (Method C), SH/T 0977-2019
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXOS
OriginImported
Manufacturer TypeAuthorized Distributor
Instrument TypeBenchtop
Excitation Source75 W Low-Power X-ray Tube
Analyte ElementSulfur (S)
Detection PrincipleMonochromatic Wavelength-Dispersive XRF
ComplianceASTM D7039, ASTM D2622, NB/SH/T 0842, ISO 20884, GB/T 11140
LOD0.18 mg/kg @ 300 s
Quantification Range0.18 mg/kg – 10 wt% (dual-range mode)
Sample Volume≤10 mL
Sample CellAccucell™ with Mylar® film
Measurement Time10–999 s (user-defined)
Data Storage>50,000 test records
Display10-inch capacitive color touchscreen
Moving PartsNone in analyzer core
CalibrationMulti-curve storage, infrequent recalibration required
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXOS
ModelClora
Instrument TypeBenchtop WDXRF Analyzer
ExcitationMonochromatic X-ray Beam
Target ElementChlorine (Cl)
X-ray Tube Power75 W
Detection Limit (LOD)0.13 ppm
Measuring Range0.13 ppm – 3000 ppm (standard), up to 4 wt% (optional)
Sample Volume≤10 mL
Measurement Time30–900 s (user-configurable)
Sample FormLiquid hydrocarbons, aqueous solutions, solid powders (with AccuCell cup)
ComplianceASTM D7536-16, ASTM D4929-19 (Method C), SH/T 0977-2019
Optical SystemDual Hyperbolic Bent-Crystal Monochromators
DetectorHigh-resolution proportional counter or scintillation detector (configuration-dependent)
CalibrationMulti-curve storage, manual high-sulfur/low-chlorine correction
Optional AccessoriesAccuFlow™ suspension compensation module, AccuCell™ sample cups, automated sample changer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXOS
ModelSignal
Instrument TypeBenchtop
ExcitationMonochromatic WDXRF
Target ElementSilicon (Si)
X-ray Tube Power75 W
Detection Limit (LOD)0.65 ppm (at 600 s)
Measurable Range0.65–3000 ppm
Sample Volume≤10 mL
Sample MembraneProlene film
Measurement Time30–900 s (user-configurable)
ComplianceASTM D7757-17, NB/SH/T 0993-2019
Show next