| Brand | XOS |
|---|---|
| Model | Phoebe |
| Instrument Type | Benchtop |
| Excitation Principle | Monochromatic Wavelength-Dispersive XRF |
| Target Element | Phosphorus (P) |
| X-ray Tube Power | 75 W |
| Detection Limit (LOD) | 0.4 ppm (at 600 s) |
| Quantification Range | 0.4 – 3000 ppm |
| Sample Volume | ≤10 mL |
| Sample Containment | Prolene film |
| Measurement Time | 30–900 s (user-selectable) |
| Calibration | Multi-curve storage |
| Motion Components | None |
| Gas/Combustion Required | No |
| Operating Environment | Standard laboratory AC power only |
| Brand | Teledyne Photon Machines |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | IRIDIA Ultra-Fast Imaging Excimer |
| Laser Type | ArF Excimer (193 nm) |
| Repetition Rate | 300 Hz / 500 Hz |
| Ablation Cell | Cobalt™ Fast-Washout Chamber (< 5 ms aerosol washout) |
| Gas Integration | Integrated ArF pre-mixed and He gas cabinets with active pressure relief and fully enclosed design |
| Gas Management | Patented ExiCheck™ automated ArF gas exchange module |
| Optical Path | Class 1 laser safety architecture |
| Beam Delivery | Dual-polarization optics (Geo Edition) or dual-attenuator configuration (BIO Edition) |
| Mirror Lifetime | 5× extended service life via multi-use reflective optics |
| Warranty | 2 years / 2 billion shots |
| Brand | ENTECH |
|---|---|
| Model | CS1200E |
| Type | 24-Hour Constant-Flow, Ambient-Pressure Gas Samplers |
| Configuration | Single-Channel Passive Canister Sampling System |
| Flow Control | Sapphire Orifice + Precision Pressure Regulator |
| Calibration Traceability | NIST-Traceable McDaniel Controls Flow Meter |
| Surface Treatment | Electropolished Stainless Steel with Silonite™ Fused-Silica Coating (Optional, denoted by “S” suffix) |
| Operating Range | 1–168 hours (adjustable via interchangeable sapphire orifices) |
| Inlet Protection | Hydrophobic Cap with Particulate Filtration |
| Compliance | Designed for EPA TO-14A, TO-15, ASTM D5466, and ISO 16017-1 Compliant Sampling |
| Brand | XOS |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop/Lab-Floor Standing |
| Configuration | Standard Model |
| Application Sector | Energy & Petrochemicals |
| Elemental Range | S, P, Cl, K, Ca, V, Cr, Mn, Fe, Co, Ni, Cu, Zn |
| Quantification Range | 5.7 ppm – 10 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | ≤2% RSD (at 100 ppm level) |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Brechbühler |
|---|---|
| Origin | Switzerland |
| Model | Sniffer9100 |
| Interface Tube Length | 80 cm or 140 cm |
| Control Module Dimensions | 350 × 375 × 195 mm |
| Temperature Control Range | 50–325 °C (1 °C resolution, max recommended 280 °C) |
| Output Signals | 0–1 V, 0–5 V, 0–10 V |
| I/O Synchronization | Start In, Stop In, Ready Out, Inhibit Ready In |
| Network Interface | TCP/IP LAN |
| Max Concurrent Units per GC | 3 |
| Brand | XOS |
|---|---|
| Model | Clora Online |
| Measurement Principle | Monochromatic Wavelength-Dispersive X-ray Fluorescence (MWD-XRF) |
| Detection Limit | 0.2 ppm (in hydrocarbon matrix), 0.6 ppm (in aqueous matrix) |
| Measurable Range | 0.2 ppm – 3000 ppm |
| Compliance | ASTM D7536-16, ASTM D4929-19 (Method C), SH/T 0977-2019 |
| Sample Types | Crude oil, naphtha, gasoline, diesel, and other liquid petroleum streams |
| Installation Options | Freestanding or wall-mounted |
| Explosion Protection | Configurable to ATEX Zone 1/21 or NEC Class I Div 1/2, Groups B–D, T4 |
| Optical System | Dual hyperbolic curved crystal monochromator |
| Detector Type | High-resolution silicon drift detector (SDD) |
| Excitation Source | Low-power sealed-tube X-ray source |
| Analysis Spot Size | < 5 mm diameter |
| Calibration Requirement | Single-point calibration sufficient for full-range quantification across crude oil and distillates |
| Brand | CETAC |
|---|---|
| Origin | Imported |
| Model | Aridus3 |
| Instrument Type | Multifunctional Autosampler for ICP-MS/ICP-OES |
| Construction Materials | PFA-only fluid path |
| Nebulizer Type | Low-flow, micro-consumption concentric nebulizer |
| Desolvation Technology | Heated hydrophobic membrane-based solvent removal |
| Waste Liquid Handling | Active vacuum-assisted back-purge |
| Gas Control | Integrated mass flow controllers (MFCs) for carrier and make-up gases |
| Software Interface | Aridus Link with remote temperature and flow setpoint control |
| Compliance | Compatible with GLP/GMP workflows |
| Safety | Full PFA compatibility enables direct analysis of HF-containing matrices (e.g., geological digests, semiconductor etchants) |
| Brand | LCTech |
|---|---|
| Origin | Germany |
| Model | D-EVA |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Control Accuracy | ±0.1 °C |
| Maximum Sample Volume per Position | 85 mL |
| Parallel Processing Capacity | 1–47 samples |
| Final Volume Control Range | 30–100 µL |
| Solvent Recovery | Cryogenic Cold Trap (−50 °C typical) |
| Rotor Compatibility | Multiple interchangeable rotors for vials, tubes, and microplates |
| Brand | LCTech |
|---|---|
| Origin | Germany |
| Model | FREESTYLE XANA |
| Automation Level | Fully Automated |
| Number of Channels | Multi-channel |
| SPE Format | Cartridge-based Solid Phase Extraction |
| Flow Rate Control | 0.1–30.0 mL/min |
| Solvent Selection | Up to 8 eluents |
| Sample Capacity | 24 positions |
| Sample Volume Range | 1–4 L |
| Wetted Materials | Stainless Steel (316), Polytetrafluoroethylene (PTFE), Borosilicate Glass |
| Brand | Thomas Cain |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | DEENA m |
| Instrument Type | Graphite Digestion System |
| Automation Level | Fully Automatic |
| Sample Positions | 60 (2 × 30-position racks) |
| Temperature Range | Ambient to 240 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Mechanism | PTFE-coated Graphite Block |
| Reagent Channels | 9 (with ≤1% volumetric accuracy, ≤0.025 mL or 1% precision, max. delivery rate 4 mL/s) |
| Final Volume Adjustment Precision | <1% at 50 mL |
| Digestion Vessel Capacity | 30 × 50 mL |
| Communication Interface | RS-232 or USB |
| Power Supply | 120–240 V AC, 15 A |
| Brand | IDES |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1016 |
| Pricing | Upon Request |
| Brand | LCTech |
|---|---|
| Origin | Germany |
| Model | DEXTech 16 |
| Weight | 280 kg |
| Compliance Standards | GB 5009.205–2013, GB 5009.190–2014, GB/T 28643–2012, HJ 77.1–2008, HJ 77.2–2008, HJ 77.3–2008, HJ 77.4–2008 |
| Brand | SEAL |
|---|---|
| Model | AQ700 |
| Instrument Type | Discrete Analyzer |
| Wavelength Range | 350–880 nm |
| Sample Capacity | 1 rack (up to 120 positions, configurable per tray) |
| Reagent Positions | 1 rack (up to 60 positions) |
| Cuvette Pathlength | 10 mm |
| Light Source | Tungsten-halogen lamp |
| Detection Principle | Photometric Absorption Spectrophotometry |
| Automation Architecture | 4-axis robotic arm with 4 independent sample trays |
| Operational Mode | Unattended batch processing with integrated reagent cooling and temperature-controlled reaction zones |
| Brand | Tekmar |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Detection Limit | 50 ppb |
| Linear Range | 0–20,000 ppm (with 0.5 mL injection volume) |
| Compliance Standards | EPA 415.1/415.3/9060A, ISO 8245, EN 1484, USP <643>, ASTM D2579, SM 5310B, HJ 501-2009, GB/T 32116-2015, AOAC 973.47 |
| Brand | Spark Holland |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Alias |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 48 × 2 mL vials (2 racks) |
| Minimum Injection Volume | 0.1 µL |
| Standard Loop Volume | 100 µL (optional up to 10 mL) |
| Positioning Accuracy | < 0.4 mm |
| Motion Architecture | XYZ three-axis robotic arm |
| Needle Wash | Internal and external needle wash with pressurized headspace purge |
| Repeat Injection Capability | Unlimited cycles per sample |
| Brand | XOS |
|---|---|
| Model | Sindie +Cl |
| Instrument Type | Benchtop WDXRF Spectrometer |
| Excitation | Monochromatic Wavelength-Dispersive XRF (MWDXRF) |
| X-ray Tube Power | 75 W |
| Elements Analyzed | Sulfur (S), Chlorine (Cl) |
| LOD | 0.4 ppm (S), 0.3 ppm (Cl) |
| Quantification Range | 0.4 ppm – 5 wt% (S), 0.3 ppm – 3000 ppm (Cl) |
| Sample Volume | ≤10 mL |
| Sample Membrane | Mylar film |
| Measurement Time | 30–900 s (user-configurable) |
| Detector Configuration | Dual independent solid-state detectors |
| Compliance | ASTM D7039-15, ASTM D2622, ASTM D7536-16, ASTM D4929-19, ISO 20884:2019, NB/SH/T 0842-2017, SH/T 0977-2019, GB 11140-2008 |
| Brand | LCTech |
|---|---|
| Origin | Germany |
| Model | FREESTYLE GPC EVA |
| Flow Rate | 0–40 mL/min |
| Maximum Pressure | 3000 psi |
| Flow Stability | ±0.1% |
| Auto-sampler Capacity | 30–60 vials |
| Auto-sampler Volume per Vial | 100 mL |
| Vacuum Pump | Chemically resistant diaphragm pump, variable-frequency controlled, pumping speed 0.8 m³/h, ultimate vacuum 2 mbar (1.5–760 torr) |
| Evaporation Principle | Low-temperature vacuum evaporation with PID-controlled jacketed heating block for room-temperature final volume adjustment |
| Brand | Brooks Rand Lab |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | MERX Total Mercury Analyzer |
| Instrument Type | Portable |
| Measurement Principle | Cold Vapor Atomic Fluorescence Spectrometry (CVAFS) |
| Detection Limit | 0.3 ng/m³ (equivalent to 0.3 pg/L at standard temperature and pressure) |
| Precision | RSD ≤ 3% at 500 pg loading |
| Linear Dynamic Range | 0.2–400 ng per sample |
| Analysis Time | < 4 minutes per sample |
| Airflow Control | 20–3,000 mL/min (±3% accuracy) |
| Sample Collection | Dual-bed gold-coated sand amalgamation traps |
| Compliance | EPA Method IO-5, ASTM D6784-22 (for mercury in ambient air), ISO 15202-2:2021 |
| Brand | Entech |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Entech 3100D |
| Pricing | Upon Request |
| Brand | SEAL |
|---|---|
| Origin | Imported |
| Model | AQ300 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 350–880 nm |
| Sample Capacity | 80 or 120 positions |
| Reagent Positions | 26 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | LCTech |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FREESTYLE QuEChERS |
| Automation Level | Fully Automatic |
| Channel Count | Single Channel |
| Extraction Mode | Column-Based SPE |
| Flow Rate Control | 120 mL/min |
| Elution Solvent Types | 5 |
| Sample Capacity | 60 positions |
| Sample Loading Volume | 0–50 mL |
| Wetted Materials | Stainless Steel, Polytetrafluoroethylene (PTFE), Borosilicate Glass |
| Brand | Tekmar |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Water & Soil Compatible |
| Sample Tray Capacity | 84 positions |
| Trap Temperature Range | Ambient to 350 °C |
| Purge Volumes | 5 mL and 25 mL selectable |
| Flow Control | Mass Flow Controller (MFC) with programmable pressure/flow profiles |
| Cleaning | High-Temperature Water Rinse |
| Optional Features | Foam Monitoring/Elimination, Multi-Application Traps |
| Regulatory Compliance | ASTM D6866, EPA Methods 502.2, 524.2, 524.4, 624, 8260D, 8270E |
| Brand | Spark Holland |
|---|---|
| Origin | Netherlands |
| Model | UHPLC Spark |
| Instrument Type | Ultra-High-Performance Liquid Chromatography–Online Solid-Phase Extraction (UHPLC–SPE) System |
| Flow Rate Range | 1–4000 µL/min |
| Maximum Pressure | 18,850 psi |
| Flow Precision | ≤ 0.075 % RSD (at 200–2000 µL/min) |
| Flow Accuracy | ±1 % (at 200–2000 µL/min) |
| Sample Tray Capacity | 96 positions × 1.5 mL vials |
| Injection Volume Range | 1–10,000 µL |
| Column Oven Temperature Range | 5–90 °C |
| UV-Vis Detector Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | XOS |
|---|---|
| Model | Sindie R2 |
| Instrument Type | Benchtop |
| Excitation Principle | Monochromatic WDXRF (MWD-XRF) |
| Target Element | Sulfur (S) |
| X-ray Tube Power | 75 W |
| Detection Limit | 0.4 mg/kg @ 300 s |
| Measuring Range | 0.4 mg/kg – 3000 mg/kg and 3000 mg/kg – 10 wt% |
| Sample Volume | ≤10 mL |
| Sample Membrane | Polyethylene (Mylar) |
| Measurement Time | 10–999 s (user-selectable) |
| Display | 10-inch color touchscreen |
| Data Storage Capacity | >50,000 test records |
| Compliance Standards | ASTM D7039-15a(2020), ASTM D2622-21, NB/SH/T 0842-2017, ISO 20884:2019, GB/T 11140-2008 |