Empowering Scientific Discovery

York Instruments

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhyMetrix
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelPGA530
Sensor TypeElectrochemical
Measurement Accuracy±1% FS
Response TimeT90 < 15 s, T95 < 25 s
Resolution0.001% O₂
Measurement Ranges0–1%, 0–5%, 0–10%, 0–25%, 0–100% O₂ (auto-ranging)
Repeatability±0.5% FS
Operating Temperature0–45 °C with full-range temperature compensation
Power Supply110–220 VAC or 12–36 VDC
Dimensions200 × 80 × 102 mm (H × W × D)
Weight1.6 kg
Process Connection1/4" Swagelok compression fitting (male thread)
Enclosure RatingIP67
DisplayFull-color LCD with adjustable backlight
Output Options4–20 mA analog, relay alarm (SPDT), RS485 Modbus RTU
Environmental ComplianceCE, RoHS, UL-listed power input
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhyMetrix
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelPGA500
Sensor TypeElectrochemical
Measurement Accuracy±1% FS (@20°C)
Response TimeT90 < 15 s, T95 < 25 s
Resolution0.01 ppm
Measurement Ranges0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–1% vol (auto-ranging)
Interface1/8" Swagelok compression fitting
Operating Temperature0–45°C with full-range temperature compensation
Power Supply110–220 VAC or 12–36 VDC
Dimensions200 mm (H) × 80 mm (W) × 102 mm (D)
Weight1.85 kg
Pressure Rating1 MPa (integrated needle valve)
Enclosure RatingIP67
Output Signal4–20 mA analog
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhyMetrix
OriginUSA
ModelPOA300
Sensor TypeElectrochemical
Measurement Accuracy±1% FS
Response TimeT90 < 15 s, T95 < 25 s
Resolution0.001%
Measurement Ranges0–1%, 0–5%, 0–10%, 0–25%, 0–100% O₂ (auto-ranging)
Operating Temperature0–45 °C with full-range temperature compensation
Power SupplyRechargeable Li-ion battery (USB-C charging)
Ingress ProtectionIP67
Hazardous Area CertificationATEX/IECEx compliant — Class I, Div. 1, Groups A, B, C, D
Maximum Pressure Rating (Needle Valve)1 MPa
Weight2.0 kg
Dimensions (W×D×H)138 × 185 × 112 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhyMetrix
OriginUSA
ModelPOA200
Sensor TypeElectrochemical
Measurement Accuracy±1% FS (@20°C)
Response Time<10 s (100 ppm–1%), <25 s (0–10 ppm)
Resolution0.01 ppm
Operating Temperature Range0–45°C (32–113°F)
Sample Pressure5–30 psig
Flow Rate0.2–2.0 SCFH
DisplayBacklit graphical LCD with auto-scaling trend plot
Data Storage>10,000 records (O₂, temperature, pressure)
PowerRechargeable Li-ion battery (USB/AC adapter charging), intrinsic safety certified
Enclosure RatingIP67/IP68
Hazardous Area CertificationClass I, Div. 1, Groups A, B, C, D
Dimensions142 × 185 × 140 mm (L×W×H)
Weight2.45 kg
Internal Wetted Materials316 stainless steel
Inlet/Outlet Fitting1/8" Swagelok® compression (optional)
CalibrationDual-mode (auto/manual), traceable to NIST-certified 80% O₂ standard gas
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhyMetrix
OriginUSA
ModelPOA3500
Sensor TypeParamagnetic
Measurement Range0–100% O₂
Accuracy<±0.1% FS
Repeatability<±0.1% FS
Resolution0.01% O₂
Response Time (T90)<15 s
Zero Drift<±0.1% FS/week
Span Drift<±0.15% FS/week
Operating Temperature−20 to +40 °C
Sample Pressure1–10 psig
Sample Flow Rate1–2 L/min
Display5″ LCD Touchscreen
Power SupplyRechargeable Li-ion Battery (220 VAC, 50 Hz, 50 W charger)
Dimensions298 mm (H) × 154 mm (W) × 336 mm (D)
Weight3.7 kg
Enclosure MaterialAnodized Aluminum Alloy
Output SignalsRS-232 digital, 4–20 mA analog
Data Storage Capacity10,000 records
Flow Sensitivity±0.1% FS
Tilt Sensitivity±0.15% FS per 15°
Optional AccessoriesIntegrated sample pump, external thermal printer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhyMetrix
OriginUSA
ModelPGA500-Ex
Measurement PrincipleElectrochemical Sensor
Range Options0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–1% O₂ (auto-ranging)
Resolution0.01 ppmv
Accuracy≤ ±2% FS
Repeatability±1% FS
Response Time (T90)<180 s (10,000 → 1,000 ppm)
Operating Temperature−20 to +60 °C
IP RatingIP65
Ingress PressureMax. 1 bar (gauge)
Sample Flow Rate>1 NL/min
Display3.5″ color LCD
Power Supply176–264 VAC / 47–63 Hz or 15–28 VDC
Power Consumption5 W
Output Signals4–20 mA (HART-enabled), 0–20 mA, 0–24 mA (Rₗ < 500 Ω)
Alarm Outputs2 × programmable SPDT relays (250 VAC/5 A, 30 VDC/5 A, resistive load)
CommunicationRS-485, Modbus RTU
Enclosure CertificationEx d IIC T4
Dimensions355 × 224 × 172 mm (H × W × D)
Weight10.95 kg
Inlet/Outlet Fitting316 stainless steel 1/4″ compression