| Brand | PhyMetrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PGA530 |
| Sensor Type | Electrochemical |
| Measurement Accuracy | ±1% FS |
| Response Time | T90 < 15 s, T95 < 25 s |
| Resolution | 0.001% O₂ |
| Measurement Ranges | 0–1%, 0–5%, 0–10%, 0–25%, 0–100% O₂ (auto-ranging) |
| Repeatability | ±0.5% FS |
| Operating Temperature | 0–45 °C with full-range temperature compensation |
| Power Supply | 110–220 VAC or 12–36 VDC |
| Dimensions | 200 × 80 × 102 mm (H × W × D) |
| Weight | 1.6 kg |
| Process Connection | 1/4" Swagelok compression fitting (male thread) |
| Enclosure Rating | IP67 |
| Display | Full-color LCD with adjustable backlight |
| Output Options | 4–20 mA analog, relay alarm (SPDT), RS485 Modbus RTU |
| Environmental Compliance | CE, RoHS, UL-listed power input |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CPH 6300 |
| Price | Upon Request |
| Pressure Range | 0–10 kPa to 0–100 MPa |
| Pressure Types | Gauge (positive/negative), Absolute, Differential |
| Accuracy | ±0.2 % FS (standard), optional ±0.1 % FS with calibration certificate |
| Sensor Interface | Plug-and-play interchangeable pressure sensor module |
| Included Software | GSoft Data Logging & Evaluation Software |
| Accessories | Comprehensive service kit including hand pump (CT12.01) |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Pascal 100 |
| Pricing | Upon Request |
| Display | Large Capacitive Touchscreen |
| Pressure Generation | Integrated Internal Pressure/Vacuum Source |
| Channels | 4 Independent Measurement Channels |
| Input/Output Modules | Up to 2 Inputs + 2 Outputs (Galvanically Isolated) |
| Pressure Sensors | 4 Internal + 2 External |
| Data Logging | Onboard Memory with Calibration Report Storage |
| Certification | ATEX II 2G Ex ib IIC T4 (Optional IS Version) |
| Communication | USB & RS232 for Remote Control and Report Export |
| Compliance | Fully Supports ISO/IEC 17025 Traceable Calibration Documentation |
| Brand | York Instruments |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CPG2500 |
| Price | Upon Request |
| Internal Pressure Range | 2.5 kPa to 290 MPa |
| External Pressure Range | 2.5 kPa to 40 MPa |
| Sensor Configuration | Three-channel (two internal, one external) |
| Accuracy Options | 0.008 % IS-33 / 0.008 % IS-50 / 0.01 % IS-50 (k=2, total measurement uncertainty) |
| Uncertainty Components | Intrinsic instrument performance, reference standard uncertainty, long-term stability, environmental influence (temperature, ambient pressure), zero-drift compensation range, thermal effects |
| Brand | York Instruments |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CPG 500 |
| Pricing | Available Upon Request |
| Brand | PhyMetrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PGA500 |
| Sensor Type | Electrochemical |
| Measurement Accuracy | ±1% FS (@20°C) |
| Response Time | T90 < 15 s, T95 < 25 s |
| Resolution | 0.01 ppm |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–1% vol (auto-ranging) |
| Interface | 1/8" Swagelok compression fitting |
| Operating Temperature | 0–45°C with full-range temperature compensation |
| Power Supply | 110–220 VAC or 12–36 VDC |
| Dimensions | 200 mm (H) × 80 mm (W) × 102 mm (D) |
| Weight | 1.85 kg |
| Pressure Rating | 1 MPa (integrated needle valve) |
| Enclosure Rating | IP67 |
| Output Signal | 4–20 mA analog |
| Brand | Beamex |
|---|---|
| Origin | Finland |
| Model | MC2-II |
| Measurement & Output Isolation | Yes |
| Display | 3.5" High-Resolution TFT Color Screen |
| Operating Temperature | -10 °C to 50 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | <90% RH (non-condensing) |
| Power Supply | Rechargeable Li-ion battery or 12 V DC adapter (battery charging during AC operation) |
| Dimensions | 208 mm × 101 mm × 55 mm |
| Weight | ~700 g |
| Electrical Connections | 4 mm banana jacks (measurement/output), 2.1 mm DC charging port, DB9 RS232 serial port, 7-pin aviation connector for optional pressure modules (e.g., SPMK518/SPMK517) |
| Thermocouple Interface | Miniature flat thermocouple socket with integrated automatic cold-junction compensation (CJC) module |
| Resistance Measurement | 3-wire and 4-wire modes |
| Signal Accuracy (20 °C ±5 °C) | Current ±(0.01% RD + 0.005% FS), Voltage ±(0.01% RD + 0.005% FS), Resistance (4-wire) ±(0.01% RD + 0.005% FS), Frequency ±(0.005% RD + 0.002% FS), Pulse ±1 count |
| Thermocouple Temp Accuracy (K-type, -100–600 °C) | ±0.3 °C (meas), ±0.2 °C (sim) |
| Pt100 (−100–200 °C) | ±0.14 °C (meas, 4-wire) |
| DC24V Loop Power | 24.0 V ±0.5 V |
| Data Logging | Internal storage with timestamped records |
| Firmware Upgrade | Over-the-air via RS232 or USB-to-serial adapter |
| Compliance | Designed for use in accordance with IEC 61000-4 (EMC), IEC 61010-1 (Safety), and supports audit-ready documentation per ISO/IEC 17025 and ANSI/NCSL Z540 requirements |
| Brand | PhyMetrix |
|---|---|
| Origin | USA |
| Model | POA300 |
| Sensor Type | Electrochemical |
| Measurement Accuracy | ±1% FS |
| Response Time | T90 < 15 s, T95 < 25 s |
| Resolution | 0.001% |
| Measurement Ranges | 0–1%, 0–5%, 0–10%, 0–25%, 0–100% O₂ (auto-ranging) |
| Operating Temperature | 0–45 °C with full-range temperature compensation |
| Power Supply | Rechargeable Li-ion battery (USB-C charging) |
| Ingress Protection | IP67 |
| Hazardous Area Certification | ATEX/IECEx compliant — Class I, Div. 1, Groups A, B, C, D |
| Maximum Pressure Rating (Needle Valve) | 1 MPa |
| Weight | 2.0 kg |
| Dimensions (W×D×H) | 138 × 185 × 112 mm |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | GPS-III |
| Price | Upon Request |
| Pressure Range | 200 / 276 / 500 MPa |
| Pressure Medium | Hydraulic Oil or Water |
| Control Stability | 0.005 % FS (0.05 % FS at 500 MPa) |
| Accuracy | 0.01 % FS (0.1 % FS at 500 MPa) |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | CPC8000-H |
| Pricing | Upon Request |
| Pressure Range | 60 / 100 / 160 MPa |
| Pressure Medium | Hydraulic Oil or Water |
| Control Stability | 0.003 % FS |
| Accuracy | 0.01 % FS |
| Brand | PhyMetrix |
|---|---|
| Origin | USA |
| Model | POA200 |
| Sensor Type | Electrochemical |
| Measurement Accuracy | ±1% FS (@20°C) |
| Response Time | <10 s (100 ppm–1%), <25 s (0–10 ppm) |
| Resolution | 0.01 ppm |
| Operating Temperature Range | 0–45°C (32–113°F) |
| Sample Pressure | 5–30 psig |
| Flow Rate | 0.2–2.0 SCFH |
| Display | Backlit graphical LCD with auto-scaling trend plot |
| Data Storage | >10,000 records (O₂, temperature, pressure) |
| Power | Rechargeable Li-ion battery (USB/AC adapter charging), intrinsic safety certified |
| Enclosure Rating | IP67/IP68 |
| Hazardous Area Certification | Class I, Div. 1, Groups A, B, C, D |
| Dimensions | 142 × 185 × 140 mm (L×W×H) |
| Weight | 2.45 kg |
| Internal Wetted Materials | 316 stainless steel |
| Inlet/Outlet Fitting | 1/8" Swagelok® compression (optional) |
| Calibration | Dual-mode (auto/manual), traceable to NIST-certified 80% O₂ standard gas |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CPP1000-M,L |
| Price | Upon Request |
| Pressure Range | 0–100 MPa |
| Medium | Oil |
| Connection | 2 × G 1/2" Female Thread |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CPP30 |
| Pricing | Upon Request |
| Pressure Range | –95 kPa to +3.5 MPa |
| Mounting Interface | G 1/2" (male) for reference gauge |
| Test Port Connection | G 1/4" internal thread via included 0.5 m test hose (CT91.06 kit) |
| Brand | York Instruments |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CPH 6000 |
| Price | Upon Request |
| Pressure Range | 0–25 kPa to 0–600 MPa |
| Accuracy | ±0.025 % of reading (including accredited calibration certificate) |
| Sensor Interface | Hot-swappable internal/external pressure sensors with automatic range recognition |
| Cable Length for Remote Sensor | ~1 m |
| Operating Modes | Measurement, Calibration, Pressure Switch Test |
| Included Accessories | Dedicated calibration software, comprehensive maintenance kit (including hand pump) |
| Brand | PhyMetrix |
|---|---|
| Origin | USA |
| Model | POA3500 |
| Sensor Type | Paramagnetic |
| Measurement Range | 0–100% O₂ |
| Accuracy | <±0.1% FS |
| Repeatability | <±0.1% FS |
| Resolution | 0.01% O₂ |
| Response Time (T90) | <15 s |
| Zero Drift | <±0.1% FS/week |
| Span Drift | <±0.15% FS/week |
| Operating Temperature | −20 to +40 °C |
| Sample Pressure | 1–10 psig |
| Sample Flow Rate | 1–2 L/min |
| Display | 5″ LCD Touchscreen |
| Power Supply | Rechargeable Li-ion Battery (220 VAC, 50 Hz, 50 W charger) |
| Dimensions | 298 mm (H) × 154 mm (W) × 336 mm (D) |
| Weight | 3.7 kg |
| Enclosure Material | Anodized Aluminum Alloy |
| Output Signals | RS-232 digital, 4–20 mA analog |
| Data Storage Capacity | 10,000 records |
| Flow Sensitivity | ±0.1% FS |
| Tilt Sensitivity | ±0.15% FS per 15° |
| Optional Accessories | Integrated sample pump, external thermal printer |
| Brand | PhyMetrix |
|---|---|
| Origin | USA |
| Model | PGA500-Ex |
| Measurement Principle | Electrochemical Sensor |
| Range Options | 0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–1% O₂ (auto-ranging) |
| Resolution | 0.01 ppmv |
| Accuracy | ≤ ±2% FS |
| Repeatability | ±1% FS |
| Response Time (T90) | <180 s (10,000 → 1,000 ppm) |
| Operating Temperature | −20 to +60 °C |
| IP Rating | IP65 |
| Ingress Pressure | Max. 1 bar (gauge) |
| Sample Flow Rate | >1 NL/min |
| Display | 3.5″ color LCD |
| Power Supply | 176–264 VAC / 47–63 Hz or 15–28 VDC |
| Power Consumption | 5 W |
| Output Signals | 4–20 mA (HART-enabled), 0–20 mA, 0–24 mA (Rₗ < 500 Ω) |
| Alarm Outputs | 2 × programmable SPDT relays (250 VAC/5 A, 30 VDC/5 A, resistive load) |
| Communication | RS-485, Modbus RTU |
| Enclosure Certification | Ex d IIC T4 |
| Dimensions | 355 × 224 × 172 mm (H × W × D) |
| Weight | 10.95 kg |
| Inlet/Outlet Fitting | 316 stainless steel 1/4″ compression |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Product Origin | Imported |
| Model | CPP700-H, CPP1000-H |
| Pricing | Upon Request |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CEP6000 |
| Pricing | Upon Request |