Empowering Scientific Discovery

York Instruments

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhyMetrix
OriginUSA
ModelDPT-810 Series
Product TypeOnline Dew Point Transmitter
Measurement PrincipleCapacitive Polymer/Metal Oxide Thin-Film Sensor
Operating Temperature Range−20 °C to +60 °C
Accuracy±2 °C (at −40 °C to +20 °C dp)
Repeatability±0.5 °C
Dew Point Range−110 °C to +20 °C dp
Response Time (95% step)180 s
Output Signal4–20 mA (2-wire, 20–28 VDC)
Enclosure RatingIP68
Housing Material316 Stainless Steel
Process Connection3/4″–16 UNF
Max. Operating Pressure6 bar
Weight0.17 kg
Dimensions (L × Ø)138.4 mm × 30 mm
Resolution<0.01 °C dp
ComplianceCE, NIST-Traceable Calibration, ATEX/IECEx Optional (with certified housing variant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhyMetrix
OriginUSA
ModelDPT-990EX
Product TypeOnline Dew Point Meter
Measurement PrincipleChilled-Mirror–Based Electrochemical Metal Oxide Sensor (Nanoporous Metal Oxide Film)
Operating Temperature Range−110 °C to +20 °C (Dew Point)
Ambient Operating Temperature−20 °C to +60 °C
Accuracy±1 °C
Repeatability±1 °C
Enclosure RatingIP65
Power Supply90–260 VAC (47–63 Hz) or 12–24 VDC (10 VA)
Output Signal4–20 mA HART-enabled analog output
Pressure Limit≤68 bar (gauge)
Sample Flow Rate>1 NL/min
CertificationFM/CSA Class I, Div 1, Groups B, C, D
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhyMetrix
OriginUSA
ModelDPT-500
Product TypePortable Dew Point Meter
Measurement PrincipleCapacitive Metal Oxide Thin-Film Sensor (Nanoporous Al₂O₃)
Operating Temperature-20 °C to +60 °C
Accuracy±2 °C (dew point)
Repeatability±0.5 °C
Dew Point Range-110 °C to +20 °C
Response Time≤3 min to 95% of step change (dry-to-wet)
Gas Flow Rate>1 L/min
Temperature Sensor Range-40 °C to +70 °C
Pressure Sensor Option0–150 PSIA (0–10 bar), ±1% FS
Display Units°C(dp), °F(dp), ppmv, ppmw, µbar, g/m³, lb/1000 ft³
Data Logging Capacity>4000 records (dew point, temperature, pressure)
PowerRechargeable Li-ion battery (USB or AC adapter charging)
Enclosure RatingIP65 (body), IP67/IP68 (connector with cap)
ATEX CertificationEx II 2 G
Housing MaterialImpact-resistant polyamide 12
Wetted Materials316L stainless steel, PTFE
Dimensions187 × 106 × 50 mm (L×W×H)
Weight0.8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYork Instruments
OriginBeijing, China
Manufacturer TypeManufacturer
Product TypePortable Dew Point Meter
Measurement PrincipleChilled-Mirror Condensation
Operating Temperature-20 °C to +40 °C
Accuracy±0.1 °C (dew point)
Repeatability±0.05 °C (dew point)
DisplayHigh-Resolution Capacitive Touch LCD
User InterfaceGraphical, Multilingual (English/Chinese), Step-by-Step Guidance
Mirror ControlDigital Fuzzy Logic with Auto-Balance Algorithm
Mirror MaintenanceIntegrated Mirror Inspection and Automated Cleaning Sequence
DiagnosticsReal-Time Self-Diagnostic Engine with Fault Classification
Communication InterfacesRS-485, USB 2.0
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYork Instruments
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelDM9200
Product TypePortable Dew Point Meter
Measurement PrincipleChilled Mirror Condensation
Operating Temperature Range−30 to +90 °C
Accuracy±0.15 °C
Repeatability±0.05 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhyMetrix
OriginUSA
ModelDPT-910
TypeOnline Dew Point Analyzer
PrincipleChilled-Mirror Hygrometry (Nanoporous Metal Oxide Sensor)
Measurement Range−110 °C to +20 °C (dew point)
Accuracy±2 °C
Operating Temperature−20 °C to +60 °C
Enclosure RatingIP66 & IP68
Hazardous Area CertificationsFM/CSA Class I, Div 1, Groups B, C, D
ATEX/IECExEx d IIC T6 Gb / Ex d IIIC T6 Db
Gas Inlet/Outlet1/4″ Swagelok stainless steel fittings
Sample Flow Rate>1 L/min
Power Options90–260 VAC, 47–440 Hz
OutputsIsolated RS-422
HousingFiberglass-reinforced polymer (FRP) enclosure with large optical-grade viewport
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhyMetrix
OriginUSA
ModelDPT-600plus
TypePortable/Benchtop Dew Point Meter
PrincipleCapacitive Polymer Sensor (Nanoporous Metal Oxide Film)
Operating Temperature-20 °C to +60 °C
Accuracy±2 °C
Repeatability±0.5 °C
Dew Point Range-110 °C to +20 °C (standard), optional -60 °C to +20 °C
Response Time (T95)≤3 min (dry-to-wet)
Resolution0.1 °C
Temperature Compensation Range-40 °C to +70 °C
Flow Rate1–5 SCFH (recommended 2–4 SCFH)
Pressure MeasurementBuilt-in absolute pressure sensor with dew point correction
Data Storage>10,000 records (dew point, temperature, pressure)
Enclosure RatingIP67/IP68
Intrinsically SafeClass I, Div. 1, Groups A, B, C, D
Dimensions142 × 180 × 146 mm (L×W×H)
Weight2.6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYork
ModelDPT-70
TypePortable Dew Point Meter
PrincipleCapacitive Polymer Sensor
Measurement Range-70 to +30 °C (Dew Point)
Resolution0.01 °C (DP)
Accuracy±2.0 °C (DP)
Response Time (T90)<120 s
Operating Temperature-10 to +60 °C
Sample Pressure Range0–20 bar (absolute)
Power SupplyRechargeable Li-ion Battery (220 VAC charger included)
Weight0.7 kg
Dimensions (Handheld Unit)250 × 70 × 25 mm
DisplayBacklit LCD with Multi-parameter Readout
Data LoggingInternal storage with USB export to Excel-compatible CSV format
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYork Instruments
OriginBeijing, China
Manufacturer TypeManufacturer
Product TypePortable Dew Point Meter
Measurement PrincipleChilled-Mirror Hygrometry
Operating Temperature-10 °C to +35 °C
Accuracy±0.1 °C
Repeatability±0.05 °C
Dew Point Range-95 °C to +20 °C (at 20 °C ambient)
Display9.7" TFT LCD Touchscreen
Resolution0.01 °C
Output Options4–20 mA, 0–10 V, RS-485 (Modbus RTU), USB
Data StorageSD Card (FAT32, up to 32 GB)
Sample Flow Rate0.3–1 L/min
Sample Pressure0–200 kPa (abs)
Sample Temperature-20 °C to +40 °C
Mirror MaterialRhodium-plated Copper
EnclosureAluminum Alloy
Dimensions278 mm (H) × 483 mm (W) × 578 mm (D)
Weight40 kg
Power Supply198–254 VAC, 47–63 Hz, 1000 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYork Instrument
OriginUSA
ManufacturerYork Instrument
Product TypeImport
ModelFGS
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYork Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelYKDC220
ApplicationLaboratory-grade dew point calibration system
Measurement PrincipleChilled-mirror hygrometry
Operating Temperature20–25 °C
Accuracy±0.1 °C (dew point)
Repeatability±0.1 °C (dew point)
Dry Gas GeneratorGS-1000 with PSA drying
Minimum Achievable Dew Point≤ −80 °C
Input Pressure≥ 0.8 MPa
Output Pressure Range0–0.3 MPa
Power SupplyAC 220 V ±10%, 50 Hz
Power Consumption300 W
Dimensions (W×D×H)485 × 500 × 260 mm
Weight20 kg
InterfaceRS485
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYork Instrument
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelDPSS-6100
Product TypeOnline Dew Point Analyzer Sampling System
Measurement PrincipleCapacitive Polymer Sensor-Based Dew Point Detection
Pressure RatingUp to 20 MPa (for integrated pressure regulator)
Filtration Precision2 µm (stainless steel sintered filter element)
Flow Control Range0–2 L/min (adjustable via precision needle valve)
Compliance StandardsGB 50029-2014 (Compressed Air Station Design Code), GB 50093-2013 (Code for Construction and Quality Acceptance of Automation Instrumentation Engineering), GB 50030-2013 (Oxygen Station Design Code)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhyMetrix
ModelDPT-600
TypePortable/Tabletop Dew Point Meter
Measurement PrincipleCapacitive Nanoporous Metal Oxide Sensor
Dew Point Range−110 °C to +20 °C
Accuracy±2 °C
Repeatability±0.8 °C
Response Time (95% step)3 min
Operating Temperature−20 °C to +60 °C
Gas Flow Rate>1 L/min
Temperature Sensor Range−40 °C to +70 °C
Pressure Sensor Option0–150 PSIA (10 bar), ±1% FS
Enclosure RatingIP67/IP68
Dimensions199 × 162 × 84 mm (L×W×H)
Weight1.6 kg
PowerRechargeable Li-ion battery or 100–240 VAC adapter via USB Mini-B
Data Logging Capacity>4,000 records (dew point, temperature, pressure)
DisplayBacklit graphical LCD with auto-scaling bar chart
InterfaceUSB Mini-B (sealed cap), optional 4–20 mA (HART), optional ATEX-certified intrinsically safe version
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhyMetrix
OriginUSA
ModelDPT-900
Product TypeOnline Dew Point Analyzer
Measurement PrincipleElectrolytic (P2O5 Sensor)
Operating Temperature-20 °C to +60 °C
Accuracy±2 °C
Repeatability±0.5 °C
Dew Point Range-110 °C to +20 °C
Response Time≤3 min (to 95% of step change, dry-to-wet)
Gas Flow Rate>1 L/min
IP RatingIP66/IP68
Hazardous Area CertificationsFM/CSA Class I Div 1 Groups B, C, D
ATEX/IECExEx d IIC T6 Gb
Enclosure MaterialAluminum (standard), optional 316L stainless steel
Dimensions226 × 147 × 147 mm (L×W×H)
Weight2.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYork Instruments
OriginBeijing, China
Manufacturer TypeManufacturer
Product TypePortable Dew Point Meter
Measurement PrincipleChilled-Mirror Hygrometry
Operating Temperature-20 °C to +40 °C
Accuracy±0.1 °C
Repeatability±0.05 °C
Dew Point Range-70 °C to +20 °C
Resolution0.01 °C
Response Time≤60 s (for 10 °C step change)
Mirror MaterialChromium-Plated Copper
Flow Rate Range0–2 L/min (accuracy ±5%)
Pressure Sensor Range0–200 kPa (abs), accuracy ±0.25% FS
Remote Temperature Sensor4-wire PT100, accuracy ±0.1 °C, cable length <2 m
Power Supply80–264 VAC, 47–63 Hz, 400 W
Analog Outputs4–20 mA / 0–20 mA / 0–24 mA / 0–5 V / 0–10 V (3-channel, user-configurable)
Alarm Outputs2 programmable SPDT relays (250 VAC/5 A, 30 VDC/5 A, resistive load)
CommunicationUSB, RS-485, Modbus RTU protocol
Data StorageSD card (FAT32, up to 32 GB)
Display7" LCD touch screen, 1024×600 RGB WVGA, 16:9 aspect ratio
Supported Units°C, °F, ppmv, ppmw, %RH, g/kg, mg/m³
Sample Gas Temp-20 °C to +40 °C
Sample Gas Pressure0–200 kPa (abs)
Sample Flow Rate0.3–1 L/min
Environmental Humidity Limit<80% RH
Storage Temperature-20 °C to +50 °C (optimal at 20 °C)
Dimensions190 mm (H) × 483 mm (W) × 498 mm (D)
Weight15 kg
Gas Inlet Fitting1/4" stainless steel compression fitting
Enclosure MaterialAluminum alloy
Gas Path Materials316L stainless steel
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhyMetrix
OriginUSA
ModelDPT-830
Product TypeOnline Dew Point Analyzer
Measurement PrincipleCapacitive Metal Oxide Thin-Film Sensor (Nanoporous Al₂O₃-based)
Operating Temperature Range0 °C to +45 °C
Dew Point Range−110 °C to +20 °C
Accuracy±2 °C
Repeatability±0.8 °C
Response Time (T90)< 3 min
Minimum Flow Rate> 3 SCFH
Output Signals4–20 mA (user-configurable range), RS232 (configuration & data access), RS485 (Modbus RTU), Optional 433 MHz RF Wireless
Relay Outputs2 × 10 A / 240 V AC, fully user-configurable
Data LoggingOptional
Calibration TraceabilityNIST-traceable
Safety CertificationOptional Intrinsically Safe (IS) Rating
Probe ConfigurationOptional Remote-Mount Sensor Head
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYork Instruments
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryPortable Dew Point Meter
Measurement PrincipleChilled-Mirror Hygrometry
Operating Temperature10–35 °C
Accuracy±0.1 °C
Repeatability±0.05 °C
Dew Point Range−90 to +20 °C
Resolution0.01 °C
Response Time≤60 s (for ±10 °C step change)
Mirror MaterialChromium-Plated Copper
Flow Rate Range0–2 L/min (±5% FS)
Pressure Range0–200 kPa (abs), ±0.25% FS
Remote Temperature Sensor4-wire PT100, ±0.1 °C
Display9.7" LCD, 1024×768 RGB, 4:3 aspect ratio
Analog Outputs3-channel configurable (4–20 mA / 0–20 mA / 0–24 mA / 0–5 V / 0–10 V)
Digital InterfacesUSB, RS-485 (Modbus RTU)
Data StorageSD Card (FAT32, up to 32 GB)
Enclosure6U 19″ rack-mountable aluminum chassis (278 × 483 × 578 mm, 40 kg)
Gas Inlet/Outlet1/4″ VCR (in), 1/4″ stainless steel compression (out)
Wetted Materials316L stainless steel, chromium-plated copper mirror
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYork Instruments
OriginUSA
Manufacturer TypeManufacturer
Product CategoryImported
ModelSS4-A2
PricingUpon Request
Spectral RangeUV 185–260 nm, Visible 400–700 nm, IR 700–3500 nm
Detection Angle120° conical field of view
Sensitivity Options15 / 30 / 45 / 60 ft (1 ft² gasoline flame)
Response Time2–5 s at 60 ft
Operating Voltage24 VDC (20.5–34 VDC)
Relay Output1.0 A / 24 VAC
Operating Temperature−40 °C to +85 °C
Humidity Range10–90% RH (non-condensing)
Hazardous Location CertificationClass I, Div 1 & 2, Groups B, C, D
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0