Air Generator
Filter
Showing 31–60 of 109 results
| Brand | Hailong |
|---|---|
| Origin | Shanghai, China |
| Model Series | HLA-2LP, HLA-5LP, HLA-10LP, HLA-08LP |
| Output Flow | 0–2 L/min |
| Output Pressure | 0–0.5 MPa (HLA-2LP/5LP/10LP) |
| Hydrocarbon Content | < 0.1 ppm (v/v) |
| Dew Point | 0–40 °C |
| Power Consumption | 560–650 W |
| Noise Level | ≤45 dB(A) |
| Tank Volume | 23 L (HLA-08LP only) |
| Compliance | Designed for ISO 8573-1 Class 1:4:1 (compressed air purity for analytical instrumentation) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HLA-10LP |
| Price Range | USD 140–7,200 |
| Hydrocarbon Removal Principle | Catalytic Oxidation + Dual-Stage Adsorption |
| Output Flow Rate | 0–10 L/min |
| Output Pressure | 0–0.5 MPa |
| Total Hydrocarbon Content (THC) | ≤0.1 ppm (v/v) |
| Dew Point | –40 °C (at 0.5 MPa, verified per ISO 8573-1:2010 Class 2.2.2) |
| Brand | HLA |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 180C Ultra-Quiet |
| Price Range | USD $1,400 – $7,200 (FOB) |
| Hydrocarbon Removal Principle | Multi-Stage Precision Filtration (Activated Carbon + Catalytic Oxidation) |
| Output Flow Rate | 0–180 L/min |
| Output Pressure | 0–0.65 MPa (gauge) |
| Total Hydrocarbon Content | < 0.1 ppmv (as methane equivalent) |
| Dew Point | −40 °C to +40 °C (adjustable via integrated refrigerated dryer) |
| Noise Level | < 45 dB(A) at 1 m |
| Tank Volume | 35 L |
| Dimensions (W×D×H) | 970 × 520 × 750 mm |
| Weight | 200 kg |
| Brand | Hailong |
|---|---|
| Model | HLA-2000II / HLA-5000II |
| Origin | Shanghai, China |
| Compressor Type | Domestic oil-free scroll compressor |
| Output Flow | 0–2000 mL/min (HLA-2000II) / 0–5000 mL/min (HLA-5000II) |
| Output Pressure | 0–0.5 MPa (factory-set at 0.4 MPa) |
| Hydrocarbon Content | <0.1 ppm (v/v) |
| Dew Point | 0–40 °C |
| Power Consumption | 200 W (HLA-2000II) / 220 W (HLA-5000II) |
| Dimensions (W×D×H) | 460 × 290 × 380 mm |
| Weight | 20 kg |
| Operating Ambient | 0–40 °C, <85% RH |
| Brand | HLAL |
|---|---|
| Origin | Shanghai, China |
| Model | HLAL-1000, HLAL-2000 |
| Output Flow Rate | 1000 mL/min, 2000 mL/min |
| Maximum Input Air Pressure | 0–0.6 MPa |
| Hydrocarbon Content (e.g., methane) in Output Air | <0.1 ppm |
| Operating Ambient Temperature | 0–40 °C |
| Relative Humidity Limit | <85% RH |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Power Consumption | 350 W |
| Catalytic Bed Operating Temperature | 350–450 °C (factory-set at 400 °C) |
| Dimensions (W×D×H) | 380 × 360 × 260 mm |
| Net Weight | ~16 kg |
| Brand | HSPX |
|---|---|
| Model | HS-3 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Output Flow Rate | 3 L/min |
| Output Pressure Range | 0–0.4 MPa |
| Hydrocarbon Content | ≤0.1 ppm (as methane equivalent) |
| Dew Point | −60 °C |
| Purification Principle | Catalytic Cracking of Hydrocarbons |
| Power Consumption | <170 W |
| Input Voltage | 220 V ±10%, 50–60 Hz |
| Dimensions (L×W×H) | 420 × 230 × 350 mm |
| Net Weight | <26 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | PGA-2LB / PGA-5LB |
| Output Flow | 0–2 L/min (PGA-2LB) / 0–5 L/min (PGA-5LB) |
| Output Pressure | 0.4 MPa |
| Power Consumption | 145 W / 175 W |
| Noise Level | ≤42 dB(A) |
| Dimensions (L×W×H) | 500 × 260 × 380 mm |
| Weight | ~25 kg / ~28 kg |
| Air Purity | Oil-free, Triple-stage Purification |
| Cooling | Semiconductor-based Cold-drying System |
| Safety Features | Overpressure Protection, Thermal Cut-off, Low-pressure Soft-start, Automatic Drain Valve |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Model | GA-2009 |
| Hydrocarbon Removal Principle | Triple-stage air purification |
| Output Flow Rate | 0–3 L/min |
| Output Pressure | 0–0.4 MPa (adjustable) |
| Hydrocarbon Content | ≤0.1 ppm (v/v) |
| Dew Point | −60 °C |
| Dimensions | 450 × 270 × 390 mm |
| Pressure Stability | ±0.003 MPa |
| Safety Protection | Dual-stage overpressure and overcurrent protection |
| Operating Mode | Continuous or intermittent use |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Model | GA-2009S |
| Hydrocarbon Removal Principle | Molecular Sieve & Activated Carbon Adsorption |
| Output Flow Rate | 0–10 L/min (adjustable) |
| Output Pressure | 0–0.4 MPa (adjustable) |
| Hydrocarbon Content | <1 ppm (v/v) |
| Dew Point | >0 °C |
| Tank Capacity | 20 L Stainless Steel |
| Power Consumption | ≤600 W |
| Dimensions (W×D×H) | 400 × 470 × 660 mm |
| Brand | Huifen Instruments |
|---|---|
| Origin | Shandong, China |
| Model | ZAHF-3L |
| Hydrocarbon Removal Principle | Integrated physical adsorption (5A molecular sieve, silica gel, activated carbon), chemical absorption (sodium hydroxide asbestos), and catalytic oxidation (Pd/6201 catalyst) |
| Output Flow | 0–1000 mL/min (adjustable) |
| Output Pressure | A: 0–0.45 MPa |
| B | 0–0.45 MPa |
| Maximum Output Pressure | 7 bar (100 psi) |
| Hydrocarbon Content (as CH₄) | <0.1 ppm |
| Dew Point | −60 °C |
| Power Supply | 220 V, 50 Hz |
| Operating Temperature | 15–40 °C |
| Relative Humidity | ≤70% |
| Noise Level | ≤42 dB(A) |
| Rated Power | 800 W |
| Weight | ~25 kg |
| Dimensions | 5U rack-mountable form factor |
| Stabilization Time | <0.5 h |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic |
| Model | AIRCOMP30 |
| Price | Upon Request |
| Hydrocarbon Removal Principle | Pt-Pd Catalytic Cracking |
| Output Flow Rate | 30 L/min |
| Output Pressure Range | 0–7 bar |
| Total Hydrocarbon Content | < 0.1 ppm |
| Dew Point | –20 °C |
| Compressor Type | Oil-Free Imported Scroll Compressor |
| Noise Level | ≤ 52 dB(A) |
| Power Supply | 220 V AC, 50 Hz |
| Dimensions (W×D×H) | 480 × 420 × 620 mm |
| Weight | 42 kg |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | AIRCOMP60 |
| Pricing | Upon Request |
| Hydrocarbon Removal Principle | Pt-Pd Catalytic Cracking |
| Output Flow Rate | 60 L/min |
| Output Pressure Range | 0–7 bar |
| Total Hydrocarbon Content | < 0.1 ppm (as methane equivalent) |
| Dew Point | –20 °C |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | i-Lab |
| Type | Domestic |
| Model | ZeroAir1 |
| Price | Upon Request |
| Hydrocarbon Removal Principle | Pt-Pd Catalytic Cracking |
| Output Flow Rate | 1 L/min |
| Output Pressure Range | 0–6 bar |
| Total Hydrocarbon Content (THC) | <0.1 ppm |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | ZeroAir10 |
| Quotation | Upon Request |
| Hydrocarbon Removal Principle | Pt-Pd Catalytic Cracking |
| Output Flow Rate | 10 L/min |
| Output Pressure Range | 0–6 bar |
| Total Hydrocarbon Content | < 0.1 ppm (as methane equivalent) |
| Dew Point | –60 °C |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZeroAir35 |
| Quotation | Upon Request |
| Hydrocarbon Removal Principle | Pt-Pd Catalytic Oxidation |
| Output Flow Rate | 35 L/min |
| Output Pressure Range | 0–6 bar (adjustable) |
| Total Hydrocarbon Content (THC) | <0.1 ppm (as methane equivalent) |
| Residual THC after dual-stage purification | <0.05 ppm |
| Particulate Filtration | 0.01 µm absolute rating |
| Noise Level | ≤55 dB(A) |
| Continuous Operation Rating | 7×24 hours |
| Rated Service Life | >30,000 operating hours |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | ZeroAir5 |
| Pricing | Available Upon Request |
| Hydrocarbon Removal Principle | Pt-Pd Catalytic Cracking |
| Output Flow Rate | 5 L/min |
| Output Pressure Range | 0–6 bar |
| Total Hydrocarbon Content (THC) | <0.1 ppm |
| Brand | Jiedao/Kexiao |
|---|---|
| Model | WJK-2LB, WJK-5LB |
| Output Flow | 0–2000 mL/min (WJK-2LB), 0–5000 mL/min (WJK-5LB) |
| Output Pressure | 0–0.4 MPa |
| Noise Level | ≤42 dB(A) |
| Power Consumption | ≤150 W |
| Dimensions (L×W×H) | 390 × 210 × 340 mm |
| Weight | 25 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | <85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Model | JPA-3L |
| Output Flow Rate | 2.0–3000 mL/min |
| Output Pressure | 0.4 MPa |
| Noise Level | <30 dB(A) |
| Dimensions (L×W×H) | 415 × 200 × 370 mm |
| Weight | ~22 kg |
| Power Consumption | ≤150 W |
| Input Voltage | 220 ± 22 V AC, 50 ± 0.5 Hz |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤85% RH |
| Air Purity | Oil-free and desiccated |
| Brand | Jingke Ruida (Kyocera-branded distribution) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | JK-2L (2 L/min) / JK-5L (5 L/min) |
| Air Purity | Oil-Free, Triple-Stage Purification |
| Output Flow Rate | 0–2 L/min (JK-2L) / 0–5 L/min (JK-5L) |
| Output Pressure | 0–0.4 MPa (for GC instruments) or 0–0.5 MPa (for air inlet of nitrogen generators) |
| Noise Level | ≤42 dB(A) |
| Power Supply | 220 V, 50 Hz |
| Operating Temperature | 15–40 °C |
| Relative Humidity | ≤70% RH (non-condensing) |
| Rated Power | 150 W |
| Dimensions (L×W×H) | 490 × 240 × 380 mm |
| Weight | 23 kg |
| Safety Features | Dual-stage pressure relief protection, thermal cut-off control, manual drain valve |
| Filtration Stages | Pre-filter + activated carbon chamber + color-indicating silica gel chamber |
| Regulatory Compliance | Designed for GLP-compliant laboratory environments |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | ZR-5218 |
| Pricing | Upon Request |
| Brand | Leman Instruments |
|---|---|
| Origin | France |
| Model | AERO50LS |
| Hydrocarbon Removal Principle | High-Temperature Catalytic Cracking |
| Output Flow Rates | 20 / 40 / 80 L/min |
| Maximum Output Pressure | 5 bar |
| Total Hydrocarbon (THC) Content | < 0.05 ppm |
| Dew Point | –60 °C (DP) |
| Brand | Leman Instruments |
|---|---|
| Origin | France |
| Model | AERO60LS |
| Hydrocarbon Removal Principle | High-Temperature Catalytic Cracking |
| Output Flow Rates | 40, 80, 100, 120 L/min |
| Maximum Output Pressure | 5 bar |
| Total Hydrocarbons (HCnm) | ≤ 0.01 ppm |
| Dew Point | −70°C |
| Water Content | < 2 ppm (−70°C DP) |
| CO₂ | < 0.5 ppm |
| CO + CH₄ | < 0.03 ppm |
| NOₓ | < 2 ppb |
| O₃, SO₂, NH₃ | < 1 ppb |
| Particulates | < 0.1 µm |
| Brand | Leman Instruments |
|---|---|
| Origin | France |
| Model | AEROSTATION 50 TOC LC or RC |
| Hydrocarbon Removal Principle | High-Temperature Catalytic Cracking |
| Output Flow Rate | 1.5–3 L/min |
| Maximum Output Pressure | 5 bar |
| Total Hydrocarbon (THC) Content | <0.05 ppm |
| Dew Point | −60 °C (DP) |
| CO₂ Content | <1 ppm |
| Display & Connectivity | Full-color touchscreen interface |
| Brand | Leman Instruments |
|---|---|
| Origin | France |
| Model | AEROSTATION 50LC or RC |
| Hydrocarbon Removal Principle | High-Temperature Catalytic Cracking |
| Output Flow Rate | 1.5 L/min or 3 L/min |
| Maximum Output Pressure | 5 bar |
| Total Hydrocarbon (THC) Content | < 0.05 ppm (v/v) |
| Dew Point | −60 °C (DP) |
| Display & Interface | Full-color touchscreen, USB, RS485, Ethernet |
| Maintenance | Maintenance-free operation |
| Compliance | Designed for GC-FID, calibration gas standards, and permeation tube systems |
| Brand | Leman Instruments |
|---|---|
| Origin | France |
| Model | LISAS ZA |
| Hydrocarbon Removal Principle | High-Temperature Catalytic Cracking |
| Output Flow | 3 N·L/min or 6 N·L/min |
| Output Pressure | Adjustable 0.5–10 bar (7–145 psi) |
| Total Hydrocarbons (THC) | <0.05 ppm |
| CO & CH₄ | <0.05 ppm |
| Particulate Filtration | ≤0.01 µm |
| Dew Point | −60 °C |
| Power Supply | 90–260 V AC, 47–63 Hz |
| Max Power Consumption | 300 W |
| Dimensions (W×H×D) | 210 × 160 × 430 mm |
| Weight | 9 kg |
| Certifications | CE |
| Connectivity | Ethernet 10/100 + Wi-Fi |
| Display | 4.3″ TFT-LCD Touchscreen |
| Compressed Air Inlet Requirement | Oil-free, dry air per ISO 8573-1 Class 3 |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-YWF-01 |
| Hydrocarbon-Free Principle | Ultrasonic Atomization |
| Output Flow Rate | 1 L/min |
| Housing Material | Stainless Steel (SUS304) |
| Water Reservoir Capacity | 4.2 L |
| Power Supply | 220 V ±10%, 50 Hz |
| Power Consumption | 80 W |
| Dimensions (W×D×H) | 310 × 240 × 300 mm |
| Weight | 8 kg |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | A-3000 |
| Output Flow Rate | 3000 mL/min |
| Maximum Output Pressure | 0.6 MPa |
| Hydrocarbon Content | <0.1 ppm (as total hydrocarbons) |
| Oxygen Content | 20–22% (v/v) |
| Moisture Content | <3 ppm (v/v) |
| Total Hydrocarbons (THC) | <1 ppm (v/v) |
| Pressure Stability | ≤0.003 MPa |
| Rated Power | 185 W |
| Noise Level | ≤42 dB(A) |
| Dimensions (L×W×H) | 450 × 250 × 365 mm |
| Brand | Lunan Ruihong |
|---|---|
| Origin | Shandong, China |
| Model | RHA-2L (0–2 L/min) / RHA-5L (0–5 L/min) |
| Output Pressure | A Port 0–0.4 MPa, B Port 0–0.5 MPa |
| Hydrocarbon Content | <0.1 ppm (as total C1–C4, measured by GC-FID per ISO 8573-5) |
| Dew Point | −15 °C to +40 °C (adjustable via integrated refrigerated dryer and desiccant stage) |
| Noise Level | ≤42 dB(A) at 1 m |
| Power Consumption | 150 W (RHA-2L), 170 W (RHA-5L) |
| Dimensions (L×W×H) | 470 × 230 × 375 mm |
| Weight | 22 kg (RHA-2L), 23 kg (RHA-5L) |
| Input Power | 220 V AC, 50 Hz |
| Operating Ambient | 15–40 °C, RH ≤70%, non-corrosive, low-dust environment |
| Filtration Stages | Three-stage oil-free purification (particulate → coalescing → activated carbon + molecular sieve) |
| Brand | MNK |
|---|---|
| Model | MF600, MF601, MF610, MF640 |
| Origin | Beijing, China |
| Permeation Chamber | Φ24 mm × 130 mm (MF600/MF601/MF640), Φ25 mm × 170 mm (MF610) |
| Temperature Range | +5 °C to +100 °C above ambient (MF610/MF640), +10 °C to +100 °C above ambient (MF600/MF601) |
| Temp. Control Accuracy | ±0.1 °C |
| Gas Flow Rate | 0–1000 mL/min (MF600), 0–500 mL/min (MF601/MF640), 100 mL/min (MF610) |
| Flow Meter Accuracy | ±1% SP (0–10 L/min, MF610) |
| Dilution Ratio | 6:1 to 96:1 (MF610) |
| Carrier Gas Inlet | 1/4″ Swagelok (MF601/MF640) |
| Inlet Pressure | 0.3–0.4 MPa (MF601/MF640) |
| Chamber Material | PTFE-coated aluminum (MF600/MF601/MF640), stainless steel (MF610) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MF620 (Hg) / MF630 (HCHO) |
| Calibration Traceability | NIST-Traceable Permeation Tubes |
| Concentration Range | 0.1 ppb – 500 ppm (adjustable for both Hg and HCHO) |
| Flow Control | Precision Mass Flow Controllers (MFCs), 0–1000 mL/min, user-programmable or panel-controlled |
| Carrier Gas | Compressed air, nitrogen, or custom gas (dual inlet optional) |
| Configuration | Benchtop with portable footprint (W×D×H: 320×380×220 mm) |
| Permeation Tube Capacity | Up to 4 independent permeation tubes (standard: 1 Hg + 1 HCHO |
| Dilution Architecture | Dual independent dilution paths with separate temperature-controlled permeation chambers (±0.1 °C stability) |
| Output Modes | Zero gas, span gas, or alternating zero/span sequences |
| Compliance | Designed for ISO/IEC 17025-compliant calibration workflows |
