Automotive Exhaust Gas Analyzer
Filter
Showing 31–60 of 90 results
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9801 |
| Instrument Type | Online Emission Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR), Non-Dispersive Ultraviolet (NDUV), Chemiluminescence Detection (CLD), Flame Ionization Detection (FID) |
| Measured Gases | THC, CH₄, NOₓ, CO, CO₂, O₂ |
| Max. Permissible Error | ≤±2.0% of Reading Span (RS) or ≤±0.3% of Full Scale (FS) |
| Zero Drift | ≤±1% FS / 8 h |
| Span Drift | ≤±1% FS / 8 h |
| Repeatability | ≤±0.5% FS |
| Response Time (T₁₀–₉₀) | <2.5 s |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80% RH |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9801 |
| Instrument Type | Online Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR), Non-Dispersive Ultraviolet (NDUV), Chemiluminescence Detection (CLD), Flame Ionization Detection (FID) |
| Measured Gases | THC, CH₄, NOₓ, CO, CO₂, O₂ |
| Maximum Permissible Error | ≤±2.0% of Reading Span (RS) or ≤±0.3% of Full Scale (FS) |
| Zero Drift | ≤±1% FS / 8 h |
| Span Drift | ≤±1% FS / 8 h |
| Repeatability | ≤±0.5% FS |
| Response Time (T₁₀–₉₀) | <2.5 s |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80% RH |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9801 |
| Instrument Type | Online Continuous Emission Monitoring System (CEMS) |
| Detection Principle | Non-Dispersive Infrared (NDIR), Non-Dispersive Ultraviolet (NDUV), Chemiluminescence Detection (CLD), Flame Ionization Detection (FID) |
| Measured Gases | THC, CH₄, NOₓ, CO, CO₂, O₂ |
| Max. Permissible Error | ≤±2.0% R.S. or ≤±0.3% F.S. |
| Zero Drift | ≤±1% F.S./8 h |
| Span Drift | ≤±1% F.S./8 h |
| Repeatability | ≤±0.5% F.S. |
| Response Time (T₁₀–₉₀) | <2.5 s |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80% RH |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9802 |
| Instrument Type | Online |
| Measurement Principle | Constant-volume dilution sampling with gravimetric and volumetric flow control |
| Max. Permissible Error | ±2% (propane spike verification) |
| Measured Species | Diluted exhaust emissions from vehicles and engines |
| Dilution Exhaust Flow Ranges | 1–12 m³/min |
| Diluted Exhaust Temperature Control | 40 ± 5 °C |
| Bag Sampling Flow Rates | 3 / 6 / 9 L/min |
| Sample Bag Configuration | 3 diluted air bags + 3 diluted exhaust bags |
| Bag Chamber Temperature Control | 35 ± 5 °C |
| Particulate Sampling Flow | 35–65 L/min |
| Particulate Sampling Channels | 3 diluted exhaust + 1 diluted air |
| Particulate Sampling Chamber Temp. | 47 ± 5 °C |
| Dilution Air Filtration | Activated carbon + pre-filter + H13 HEPA filter |
| Operating Environment | 5–35 °C ambient temperature |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-9802 |
| Instrument Type | Online Fixed Installation |
| Measurement Principle | Constant Volume Sampling with Dilution Air Conditioning and Thermal Regulation |
| Max. Permissible Error | ±2% (Propane Spike Verification) |
| Measured Species | Diluted Exhaust Emissions from Vehicles and Engines |
| Dilution Exhaust Flow Ranges | 1–12 m³/min |
| Dilution Exhaust Temperature Control | 40 ± 5 °C |
| Bag Sampling Flow Rates | 3 / 6 / 9 L/min |
| Sample Bag Configuration | 3 Dilution Air Bags + 3 Diluted Exhaust Bags |
| Bag Chamber Temperature Control | 35 ± 5 °C |
| Particulate Sampling Flow | 35–65 L/min |
| Particulate Sampling Channels | 3 Diluted Exhaust + 1 Dilution Air |
| Particulate Sampling Box Temperature | 47 ± 5 °C |
| Dilution Air Filtration | Activated Carbon Filter + Pre-filter + H13 HEPA Filter |
| Operating Environment | 5–35 °C Ambient Temperature |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Gasboard-9802 |
| Instrument Type | Online Fixed Installation |
| Measurement Principle | Constant Volume Sampling with Dilution Air Conditioning & Flow Control |
| Max. Permissible Error | ±2% (Propane Spike Verification) |
| Measured Species | Diluted exhaust emissions from engines and vehicles |
| Dilution Exhaust Flow Ranges | 1–12, 3–24, 9–60, or 30–150 m³/min |
| Diluted Exhaust Temperature Control | 40 ± 5 °C |
| Bag Sampling Flow Rates | 3 / 6 / 9 L/min |
| Sample Bag Configuration | 3 dilution air bags + 3 diluted exhaust bags |
| Bag Chamber Temperature Control | 35 ± 5 °C |
| Particulate Sampling Flow | 35–65 L/min |
| Particulate Sampling Channels | 3 diluted exhaust + 1 dilution air |
| Particulate Sampling Box Temp. | 47 ± 5 °C |
| Dilution Air Filtration | Activated Carbon + Pre-filter + H13 HEPA |
| Operating Environment | 5–35 °C ambient temperature, ≤80% RH, 80–102 kPa atmospheric pressure |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9802 |
| Instrument Type | Online |
| Measurement Principle | Dilution-based gravimetric/volumetric sampling per ISO 8178 & UNECE R49 |
| Max. Permissible Error | ±2% (propane spike verification) |
| Measured Species | Diluted exhaust emissions from engines and vehicles |
| Dilution Exhaust Flow Range | 1–12, 3–24, 9–60, or 30–150 m³/min (configurable) |
| Diluted Exhaust Temperature Control | 40 ± 5 °C |
| Bag Sampling Flow Rates | 3, 6, or 9 L/min |
| Sample Bag Configuration | 3 dilution air bags + 3 diluted exhaust bags |
| Bag Chamber Temperature Control | 35 ± 5 °C |
| Particulate Sampling Flow | 35–65 L/min |
| Particulate Sampling Channels | 3 diluted exhaust + 1 dilution air |
| Particulate Chamber Temperature Control | 47 ± 5 °C |
| Dilution Air Filtration | Activated carbon + pre-filter + H13 HEPA |
| Operating Environment | 5–35 °C, ≤80% RH, 80–102 kPa |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-9802 |
| Instrument Type | Online System |
| Measurement Principle | Dilution-based gravimetric/volumetric sampling with thermal and flow stabilization |
| Max. Permissible Error | ±2% (propane spike verification) |
| Measured Emission Sources | Laboratory-based exhaust testing of newly manufactured mobile sources (engines & light/heavy-duty vehicles) |
| Dilution Exhaust Flow Ranges | 1–12, 3–24, 9–60, or 30–150 m³/min |
| Diluted Exhaust Temperature Control | 40 ± 5 °C |
| Bag Sampling Flow Rates | 3, 6, or 9 L/min |
| Sample Bag Configuration | 3 dilution air bags + 3 diluted exhaust bags |
| Bag Chamber Temperature Control | 35 ± 5 °C |
| Particulate Sampling Flow | 35–65 L/min |
| Particulate Sampling Channels | 3 diluted exhaust + 1 dilution air |
| Particulate Sampling Box Temperature | 47 ± 5 °C |
| Dilution Air Filtration | Activated carbon + pre-filter + H13 HEPA filter |
| Operating Environment | 5–35 °C ambient temperature, ≤80% RH, 80–102 kPa atmospheric pressure |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9805 |
| Instrument Type | Portable |
| Measurement Principles | NDIR (CO, CO₂, O₂), Electrochemical (O₂), UV-LED Differential Optical Absorption Spectroscopy (DOAS) for NO/NO₂ |
| Measured Gases | CO, CO₂, O₂, NO, NO₂, NOₓ (calculated) |
| Zero Drift (CO) | ≤±50 ppm / 4 h |
| Span Drift (CO) | ≤±2% of reading or ≤±50 ppm / 4 h |
| Resolution | CO/NO/NO₂: 0.1 ppm |
| CO₂/O₂ | 0.01% |
| Response Time (T₉₀) | ≤2.5 s (gas module) |
| Repeatability | Not specified |
| Optional Modules | Particulate Number (PN) counter (6×10²–1.3×10⁹ #/cm³, 23 nm–2.5 µm), Total Hydrocarbons (THC), Exhaust Flow Meter (EFM) with thermal mass flow principle, integrated GPS and environmental sensors (T, RH, Pₐₜₘ) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9805 |
| Instrument Type | Portable |
| Measured Gases | CO, CO₂, NO, NO₂, NOₓ, O₂, THC |
| Zero Drift | ≤±1% FS/8 h |
| Span Drift | ≤±1% FS/8 h |
| Repeatability | ≤±0.5% FS |
| Detection Principle | NDIR (CO, CO₂), NDUV (NO, NO₂), HFID (THC), Corona Charging + CPC (PN), Electrochemical/NDIR (NH₃/N₂O) |
| Operating Temperature | −10 to 45 °C |
| Relative Humidity | ≤90% RH |
| Altitude Range | 0–3000 m |
| Exhaust Flow Range | 10–2000 kg/h |
| THC Range | 0–10,000 ppmC |
| PN Size Cut-off | 10 nm or 23 nm |
| NH₃ Range | 0–1000 ppm |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Portable |
| Measurement Principle | NDIR (CO, CO₂), NDUV (NO, NO₂), HFID (THC), Corona Charging + CPC (PN), Electrochemical/NDIR (NH₃/N₂O) |
| Measured Gases | CO, CO₂, NO, NO₂, NOₓ, O₂, THC, NH₃, N₂O, PN (≥10 nm or ≥23 nm) |
| Accuracy | ≤±2.0% of Reading or ≤±0.3% of Full Scale |
| Zero Drift | ≤±1% FS / 8 h |
| Span Drift | ≤±1% FS / 8 h |
| Repeatability | ≤±0.5% FS |
| Response Time (T₁₀–₉₀) | <2.5 s (gas), <1 s (flow), <5 s (PN) |
| Operating Temperature | –10 to +45 °C |
| Relative Humidity | ≤90% RH |
| Altitude Range | 0–3000 m |
| Exhaust Flow Range | 10–2000 kg/h |
| Exhaust Temp Range | –5 to +500 °C |
| Battery Life | >8 h (Li-ion) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9805* |
| Instrument Type | Portable |
| Measurement Principles | NDIR (CO, CO₂), NDUV (NO, NO₂), HFID (THC), Corona Discharge CPC (PN), Electrochemical/NDIR (NH₃/N₂O) |
| Measured Gases | CO, CO₂, NO, NO₂, NOₓ, O₂, THC, NH₃, N₂O, PN (≥10 nm or ≥23 nm) |
| Max. Permissible Error | ≤±2.0% of Reading Span (RS) or ≤±0.3% of Full Scale (FS) |
| Zero Drift | ≤±1% FS / 8 h |
| Span Drift | ≤±1% FS / 8 h |
| Repeatability | ≤±0.5% FS |
| Operating Temperature | −10 to +45 °C |
| Relative Humidity | ≤90% RH |
| Altitude Range | 0–3000 m |
| Exhaust Flow Range | 10–600 kg/h or 100–2000 kg/h |
| Exhaust Temp. Range | −5 to +500 °C |
| Battery Life | >8 h (Li-ion) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | CUBIC-EMX-4N |
| Instrument Type | Online Continuous Emission Monitoring System (CEMS) |
| Detection Principle | Integrated TDLAS + UV-DOAS + GFC Infrared Spectroscopy |
| Measured Components | NH₃, NO, NO₂, N₂O |
| Measurement Range (NH₃) | 0–100 ppm (low), 0–5000 ppm (high) |
| Measurement Range (NO) | 0–200 ppm (low), 0–5000 ppm (high) |
| Measurement Range (NO₂) | 0–200 ppm (low), 0–3000 ppm (high) |
| Measurement Range (N₂O) | 0–200 ppm (low), 0–5000 ppm (high) |
| Sample Gas Line Temperature | 113 °C ± 6 °C |
| Sample Flow Rate | 8.0 L/min ± 1.0 L/min |
| Operating Ambient Temperature | 5–40 °C |
| Operating Relative Humidity | ≤80 % RH |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Portable Engine Emission Analyzer |
| Instrument Type | Portable |
| Detection Principle | UV-DOAS / NDUV / NDIR |
| Max. Permissible Error | NO/NO₂: ±2% rel. or ±25 ppm abs. |
| CO₂ (0–16%) | ±3% rel. or ±0.3% abs., (16–18%): ±5% rel. |
| Opacity (K) | ±2.0% rel. |
| Measurement Range | NO: 0–4000 ppm |
| NO₂ | 0–1000 ppm |
| CO₂ | 0–18% vol |
| K | 0–16 m⁻¹ |
| Resolution | NO/NO₂: 1 ppm |
| CO₂ | 0.1% vol |
| K | 0.01 m⁻¹ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Standalone Version |
| Instrument Type | Portable |
| Measurement Principle | Optical Transmission (Nephelometric Absorption) |
| Maximum Permissible Error | ±2.0% |
| Display | Integrated LCD Monitor |
| Sampling Probe | Fixed-length, heat-resistant stainless steel probe |
| Optional | Built-in thermal printer |
| Compliance | GB 3847–2018, GB 36886–2018 |
| Electrical Interface | RS-232 / RS-485 digital output & print port |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Measurement Range | Opacity N: 0–99.99% |
| Absorption Coefficient K | 0–16 m⁻¹ |
| Resolution | N: 0.1% |
| K | 0.01 m⁻¹ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Standard Edition |
| Instrument Type | Portable |
| Measurement Principle | Optical Transmission (Filter-Based Nephelometry) |
| Max. Permissible Error | ±2.0% for Opacity (N) and Absorption Coefficient (K) |
| Opacity Range | 0–99.99% (Resolution: 0.1%) |
| K-Value Range | 0–16 m⁻¹ (Resolution: 0.01 m⁻¹) |
| Engine Speed | 400–6000 rpm (Resolution: 1 rpm |
| Accuracy | ±10 rpm or ±1%) |
| Ambient Temperature | −20–60 °C (Resolution: 0.1 °C |
| Accuracy | ±4% rel. or ±0.5 °C abs.) |
| Relative Humidity | 5–99% RH (Resolution: 0.1% RH |
| Accuracy | ±5% rel. or ±3% RH abs.) |
| Atmospheric Pressure | 70–106 kPa (Resolution: 0.01 kPa |
| Accuracy | ±5% rel. or ±2 kPa abs.) |
| Oil Temperature (optional) | 0–200 °C (Resolution: 1 °C |
| Accuracy | ±5 °C abs.) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Instrument Type | Online Fixed-Position Analyzer |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Maximum Permissible Error | ≤±2.0% of Reading Span (RS) or ≤±0.3% of Full Scale (FS) |
| Measured Gases | NH₃, N₂O |
| Zero Drift | ≤±1% FS / 8 h |
| Span Drift | ≤±1% FS / 8 h |
| Repeatability | ≤±0.5% FS |
| Minimum Range | 0–50 ppm (NH₃), 0–100 ppm (N₂O) |
| Maximum Range | 0–2000 ppm (both) |
| Response Time (T₁₀–₉₀) | <2.5 s |
| Linearity | R² ≥ 0.998 |
| Operating Environment | 5–40 °C, ≤80% RH |
| Brand | ECM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | AFM1000 |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Electrochemical (Wideband Lambda/UEGO Sensor) |
| Measurement Range | 8.0–18.0 AFR |
| Accuracy | ±1.5% of reading |
| Output Signal | Linearized 0–5 V DC (AFR-proportional) |
| Sensor Thread | M18 × 1.5 mm |
| Dimensions | 4″ × 3.5″ × 1″ (101.6 × 88.9 × 25.4 mm) |
| Weight | 160 g |
| Power Supply | 11–28 VDC |
| Calibration | Single-point zero calibration in ambient air |
| Kit Includes | UEGO sensor, control module, shielded cable assembly, mounting adapter sleeve, blanking plug, and user manual |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | AFM1600D |
| Measurement Range | 0–25% O₂ |
| Accuracy | ±0.2% absolute |
| Calibration | ambient air (20.95% O₂) |
| Output | 0–5 V linear analog |
| Power Supply | 11–28 VDC |
| Operating Temperature | −20 to +85 °C |
| Sensor Thread | M18×1.5 |
| Dimensions | 68 mm × 32 mm × 100 mm |
| Weight | 125 g |
| Sensor Type | Bosch LSU 4.2 wideband lambda sensor |
| Cable Length | 3 m |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | AFRecorder1200 |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Sensing |
| Measurement Range | AFR 6–150 |
| Accuracy | ±0.6% (stoichiometric), ±0.9% (full range) |
| Response Time | <150 ms |
| Calculation Interval | 1 ms |
| Fuel Flexibility | Configurable H:C, O:C, N:C ratios and H₂ content |
| Analog Output | Linearized 0–5 V (BNC female) |
| Digital Interface | RS232 (bidirectional) |
| SEGO Sensor Output | User-configurable |
| Data Logging | Integrated |
| Statistical Functions | Mean, Min, Max, Standard Deviation |
| Power Supply | 11–28 VDC (with 100–250 VAC/DC adapter) |
| Dimensions | 190.5 × 101.6 × 30.5 mm (W × H × D) |
| Weight | 290 g |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | baroCAN |
| Sensor Inputs | 1× RH/T, 1× Absolute Pressure, 1× O₂ |
| Measurement Parameters | Relative Humidity (0–100% RH), Temperature (−40 to +125 °C), Absolute Pressure (0–500 kPa), Dew Point (0–125 °C), Water Vapor Pressure, Oxygen Concentration (0–20.946% vol), Accuracy: ±2% RH, ±0.3 °C, ±0.2 kPa, ±0.88 °C dew point, ±0.02% O₂ |
| Response Time | 1 s (RH/T/dew point/O₂), 25 ms (pressure) |
| Communication | High-Speed CAN 2.0B, ISO 11898 compliant |
| Enclosure Rating | IP67 |
| Operating Temp | −55 to +125 °C |
| Power | 6–32 VDC |
| Dimensions | 145 × 120 × 40 mm |
| Weight | 234 g |
| Threaded Ports | 1/4″ NPT/ISO for RH/T and pressure sensors |
| Configuration & Data Logging | Dedicated PC software via CAN interface |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | CO/CO2CAN |
| Instrument Type | Online |
| Detection Principle | Electrochemical Sensing |
| Max. Permissible Error | ±0.9% |
| Repeatability | ±0.15% |
| Measurement Ranges | %CO 0–20, %CO₂ 0–20, λ 0.40–25, AFR 6.0–364, %O₂ 0–25 |
| Accuracy | %CO/%CO₂ ±0.15% (abs), λ/AFR ±0.6% (theoretical), ±0.9% (mean), %O₂ ±0.1% (abs) |
| Response Time | <200 ms |
| Operating Temperature | −55 °C to +125 °C |
| Enclosure Rating | IP67 |
| Dimensions | 145 × 120 × 40 mm |
| Power Supply | 11–28 VDC |
| Communication | High-Speed CAN Bus (ISO 11898 compliant) |
| Sensor Interface | Integrated ceramic CO/CO₂ sensor with onboard EEPROM calibration memory |
| Optional | Pressure compensation kit, dual-module display head, extended sensor cable (2 m), AC/DC adapter |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | EGR 5230 |
| Instrument Type | Online Analyzer |
| Detection Principle | Electrochemical Sensing |
| Maximum Permissible Error | ±0.5% |
| Repeatability | 0.5% |
| Measurement Range | EGR 0–100% |
| Response Time | <1 s (%EGR) |
| Output | 6-channel linearized 0–5 V analog |
| Power Supply | 11–28 VDC |
| Operating Temperature | −40 °C to +85 °C |
| Sensor Mounting | 18 mm × 1.5 mm threaded O₂ sensors |
| Dimensions | 105 mm (W) × 64 mm (H) × 165 mm (D) |
| Weight | 676 g (main unit), 244 g (sensor module) |
| Cable Length | Standard 4 m, optional up to 100 m |
| Brand | ECM |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FastTEMP |
| Instrument Type | Online |
| Detection Principle | Active-Drive Thermocouple Signal Conditioning |
| Max. Permissible Error | ±1°C |
| Measurement Range | –60°C to +1370°C |
| Response Time | <50 ms (10–90%, fast mode) |
| Output | 5 mV/°C (fast & standard), output impedance <500 Ω |
| Input–Output Isolation | 200 V (sensor input to output), 500 V (power supply referenced) |
| Cold-Junction Compensation | Built-in |
| Sensor Compatibility | Grounded K-type thermocouples, minimum probe diameter 1.5 mm (1/16″), standard length 150 mm (6″) |
| Power Supply | 6–35 VDC, 200 mW |
| Enclosure Rating | IP67 |
| Operating Ambient Temp | –55°C to +125°C |
| Relative Humidity | 100% RH |
| Dimensions | 152 × 70 × 30 mm |
| Weight | 360 g |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | Lambda 5220 |
| Type | Online Analyzer |
| Detection Principle | Electrochemical (Zirconia-based Wideband Sensor) |
| Max. Permissible Error | ±0.5% of reading |
| Zero Drift | ±1% FS/24h |
| Span Drift | ±1% FS/24h |
| Repeatability | ±0.2% FS |
| Measurement Ranges | λ 0.4–25, AFR 6–364, Φ 0.04–2.5, O₂ 0–25% vol, Pressure 0–517 kPa (optional) |
| Accuracy | λ ±0.005 (at λ=1), ±0.008 (λ=0.8–1.2), ±0.009 (elsewhere) |
| Response Time | <150 ms (t₉₀) |
| Operating Temperature | −40 °C to +85 °C |
| Power Supply | 11–28 VDC |
| Analog Outputs | Six isolated 0–5 V linearized channels |
| Communication Interfaces | CAN 2.0B (user-configurable protocol), USB, RS-232 |
| Sensor Interface | M18×1.5 (Lambda probe), 1/4" NPT (pressure transducer) |
| Max. Cable Length | 100 m (sensor to analyzer) |
| Fuel Composition Parameters | Adjustable H:C, O:C, N:C, H₂ ratios |
| Compliance | Designed for R&D and production environments requiring traceable calibration per ISO/IEC 17025 practices |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | Lambda PRO |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Sensor (NTK Wideband) |
| Measurement Range | AFR 8.0–25.5 |
| Accuracy | ±1% of stoichiometric value, ±2% for non-stoichiometric conditions |
| Response Time | <150 ms |
| Calculation Interval | 2 ms |
| Fuel Compatibility | Gasoline, Methanol, and other combustible fuels (with appropriate sensor calibration) |
| Analog Output | Linearized 0–5 V DC, BNC female connector |
| SEGO Sensor Interface | Supported |
| Data Logging | Min/Max AFR and λ values |
| Power Supply | 11–28 VDC |
| Dimensions | 190.5 × 101.6 × 30.5 mm (W × H × D) |
| Weight | 340 g |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | LambdaCAN |
| Input Channels | Up to 8 lambda sensors + up to 8 optional pressure sensors |
| Lambda Range | 0.40–25 |
| AFR Range | 6.0–364 |
| O₂ Range | 0–25% |
| Pressure Range (optional) | 0–517 kPa |
| Lambda Accuracy | ±0.005 at λ=1, ±0.008 at λ=0.8–1.2, ±0.009 elsewhere |
| AFR Accuracy | ±0.1 at 14.6, ±0.2 at 12–18, ±0.5 elsewhere |
| O₂ Accuracy | ±0.2 (0–2% O₂), ±0.4 (other) |
| Pressure Accuracy | ±5.2 kPa |
| Response Time | <150 ms |
| Fuel Composition Parameters | Configurable H:C, O:C, N:C, and H₂ ratios |
| CAN Interface | High-speed CAN per ISO 11898 |
| Operating Temperature | −40 °C to +105 °C |
| Power Supply | 11–28 VDC |
| Sensor Thread | 18 mm × 1.5 mm (lambda), 1/4" NPT (pressure) |
| Module Dimensions | 145 mm × 120 mm × 40 mm |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | LambdaCAN |
| Interface | High-Speed CAN (ISO 11898) |
| Input | 1 lambda sensor + optional pressure sensor |
| Lambda Range | 0.40–25.0 |
| AFR Range | 6.0–364.0 |
| O₂ Range | 0–25% |
| Pressure Range (optional) | 0–517 kPa |
| Accuracy (λ) | ±0.005 @ λ=1, ±0.008 @ λ=0.8–1.2, ±0.009 elsewhere |
| Accuracy (AFR) | ±0.1 @ 14.6, ±0.2 @ 12–18, ±0.5 elsewhere |
| Accuracy (O₂) | ±0.2 @ 0–2%, ±0.4 elsewhere |
| Accuracy (Pressure) | ±5.2 kPa |
| Response Time | <150 ms |
| Fuel Composition Parameters | Configurable H:C, O:C, N:C, H₂ ratios |
| Operating Temperature | −40 °C to +105 °C |
| Dimensions | 145 mm × 120 mm × 40 mm |
| Power Supply | 11–28 VDC |
| Sensor Thread | 18 mm × 1.5 mm (lambda), 1/4" NPT (pressure) |
| Cable Length | Standard 0.6 m (1 m / 2 m optional) |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | LambdaCANp |
| Instrument Type | Online |
| Detection Principle | Electrochemical |
| Input | 1 lambda sensor + 1 optional pressure sensor |
| Lambda Range | 0.40–25 |
| AFR Range | 6.0–364 |
| φ Range | 0.04–2.5 |
| %O₂ Range | 0–25 |
| Pressure Range | 0–517 kPa |
| Lambda Accuracy | ±0.005 (λ=1), ±0.008 (λ=0.8–1.2), ±0.009 (other) |
| AFR Accuracy | ±0.1 (14.6 AFR), ±0.2 (12–18 AFR), ±0.5 (other) |
| %O₂ Accuracy | ±0.2 (0–2% O₂), ±0.4 (other) |
| Pressure Accuracy | ±5.2 kPa |
| Response Time | <150 ms |
| Fuel Ratio Configurability | H:C, O:C, N:C, H₂ |
| Communication | High-Speed CAN (ISO 11898 compliant) |
| Operating Temperature | −55 °C to +125 °C |
| Enclosure Rating | IP67 |
| Dimensions | 145 mm × 120 mm × 40 mm |
| Power Supply | 11–28 VDC |
| Sensor Thread | 18 mm × 1.5 mm (lambda), 1/4" NPT (pressure) |
| Cable Options | 1 m (standard), 2 m or 3 m (optional) |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | miniPEMS2 |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Sensing |
| Dimensions (Case) | 535 mm × 445 mm × 222 mm |
| Weight (Fully Loaded) | ~13 kg |
| Power Supply | Four Parallel 12 V Batteries + External Charger & AC Input |
| Data Logging | Integrated CAN-based Recorder with Remote Control Interface |
| Modular Sensor Capacity | Up to 7 Simultaneous Measurement Modules |
| Communication | CAN 2.0B, GPS (10 Hz, WAAS-enabled), OBD-II Gateway Support |
| Compliance Context | Designed for field-deployable RDE (Real Driving Emissions) testing per UN Regulation No. 83, EU 2016/427, and EPA 40 CFR Part 1065 subpart J |