| Brand | ECM |
|---|---|
| Origin | USA |
| Model | miniPEMS2 |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Sensing |
| Dimensions (Case) | 535 mm × 445 mm × 222 mm |
| Weight (Fully Loaded) | ~13 kg |
| Power Supply | Four Parallel 12 V Batteries + External Charger & AC Input |
| Data Logging | Integrated CAN-based Recorder with Remote Control Interface |
| Modular Sensor Capacity | Up to 7 Simultaneous Measurement Modules |
| Communication | CAN 2.0B, GPS (10 Hz, WAAS-enabled), OBD-II Gateway Support |
| Compliance Context | Designed for field-deployable RDE (Real Driving Emissions) testing per UN Regulation No. 83, EU 2016/427, and EPA 40 CFR Part 1065 subpart J |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | 5240 |
| Measurement Range | NOx 0–5000 ppm, NH₃ 0–1000 ppm, O₂ 0–25% vol, λ 0.4–25, AFR 6–364, φ 0.04–2.5 |
| Accuracy | NOx ±5 ppm (0–1000 ppm), ±1% FS (other) |
| Response Time | <1 s (NOx/NH₃), <150 ms (O₂/λ/AFR/φ) |
| Output | 6 × 0–5 V analog, CAN 2.0B, USB 2.0 |
| Power | 11–28 VDC |
| Sensor Thread | M20×1.5 or M18×1.5 |
| Dimensions (H×W×D) | 64 × 105 × 165 mm |
| Weight | 676 g (main unit), 244 g (sensor module) |
| Operating Temp. | −40 to +85 °C (electronics), up to 950 °C (sensor tip) |
| Optional | Pressure compensation kit, extended cable (up to 100 m), AC/DC adapter |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | NH3 5250 |
| Detection Principle | Electrochemical |
| Measurement Range | 0–2000 ppm NH₃ (λ > 1 only) |
| Pressure Range | 0–517 kPa (0–75 psia) |
| Accuracy | ±5 ppm NH₃ (0–200 ppm), ±5.2 kPa pressure |
| Response Time | <1 s |
| Analog Outputs | Six 0–5 V linearized channels |
| Communication Interfaces | High-speed CAN (configurable protocol), USB, RS232 |
| Power Supply | 11–28 VDC |
| Sensor Thread | M18×1.5 |
| Dimensions (H×W×D) | 64 mm × 105 mm × 165 mm |
| Weight | 676 g (main unit), 244 g (sensor module) |
| Operating Temperature | −40 to +85 °C (electronics), up to 450 °C (sensor tip) |
| Optional Accessories | Dual-channel NH₃ module, pressure compensation kit, mounting bracket, calibration tool, NH₃ sensor simulator, extended cable (up to 100 m), AC/DC adapter |
| Brand | ECM |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NH3CAN |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Electrochemical Sensing |
| Input | 1 Ceramic NH₃ Sensor, 1 Optional Pressure Sensor |
| Range | NH₃: 0–2000 ppm (λ > 1), Pressure: 0–517 kPa (0–75 psia) |
| Accuracy | NH₃: ±5 ppm (0–200 ppm), Pressure: ±5.2 kPa (±0.75 psia) |
| Response Time | <1 s |
| Communication | High-Speed CAN Bus (ISO 11898 Compliant) |
| Configuration | CAN-Based via PC Software, Configurable Node ID |
| Dimensions | 145 mm × 120 mm × 40 mm |
| Enclosure Rating | IP67 |
| Operating Temperature | −55 °C to +125 °C |
| Sensor Cable Length | Standard 1 m (2 m optional) |
| Sensor Max Exposure Temperature | 450 °C |
| Sensor Thread | M18 × 1.5 |
| Power Supply | 11–28 VDC (AC/DC Adapter Optional) |
| Optional Accessories | Pressure Compensation Kit, Display Heads (Single- or Dual-Module Support) |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | NOx/NH3 5241 |
| Detection Principle | Electrochemical Sensing |
| Measurement Range | NOx/NO/NO₂: 0–5000 ppm |
| NH₃ | 0–2000 ppm (λ > 1 only) |
| O₂ | 0–25% vol |
| λ | 0.4–25 |
| AFR | 6–364 |
| φ | 0.04–2.5 |
| Accuracy | NOx/NO/NO₂/NH₃: ±5 ppm (0–1000 ppm), ±1% FS (other) |
| O₂ | ±0.2% abs |
| λ/AFR/φ | ±0.8% at stoichiometric, ±1.8% avg |
| Response Time | <1 s (NOx/NO/NO₂/NH₃), <150 ms (O₂/λ/AFR/φ) |
| Operating Temperature | –40°C to +85°C (electronics), up to 950°C (sensor tip) |
| Power Supply | 11–28 VDC |
| Analog Outputs | Six 0–5 V linearized channels |
| Communication | High-speed CAN (configurable protocol) |
| Sensor Interface | M18×1.5 threaded probe |
| Dimensions (H×W×D) | 64 × 105 × 165 mm |
| Weight | 676 g (main unit), 244 g (sensor module) |
| Cable Length | Standard 4 m, extendable to 100 m |
| Optional Accessories | Pressure compensation kit, mounting bracket, calibration station, NOx/NH₃ sensor simulator, extended cable, AC/DC adapter |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | NOx5210g |
| Measurement Principle | Direct-insertion electrochemical (ceramic zirconia-based) sensing |
| NOₓ Range | 0–5000 ppm (NGK sensor, λ > 1 only) |
| Lambda (λ) Range | 0.4–25 |
| Air–Fuel Ratio (AFR) | 6–364 |
| Equivalence Ratio (Φ) | 0.04–2.5 |
| O₂ Range | 0–25% vol |
| NOₓ Accuracy | ±15 ppm (0–1000 ppm), ±1.5% FS (remaining range) |
| λ Accuracy | ±0.008 @ λ=1, ±0.016 @ λ=0.8–1.2, ±0.018 elsewhere |
| AFR Accuracy | ±0.15 @ 14.6, ±0.4 @ 12–18, ±1 elsewhere |
| Φ Accuracy | ±0.008 @ Φ=1, ±0.016 @ Φ=0.8–1.2, ±0.018 elsewhere |
| O₂ Accuracy | ±0.4% @ 0–2% O₂, ±0.8% elsewhere |
| Response Time | <1 s (NOₓ), <150 ms (λ/Φ/AFR/O₂) |
| Fuel Flexibility | Configurable H:C, O:C, N:C, H₂ ratios |
| Analog Outputs | 6 × 0–5 V (linearized, user-assignable) |
| Digital Interfaces | CAN 2.0B (user-configurable protocol), USB 2.0, RS-232 |
| Power Supply | 11–28 VDC |
| Sensor Mounting | M20×1.5 thread (NGK NOₓ probe) |
| Dimensions (Analyzer) | 105 mm W × 64 mm H × 165 mm D |
| Cable Length | Standard 4 m |
| Weight | Analyzer 676 g, Sensor Module 244 g |
| Operating Temperature | −40 °C to +85 °C |
| Optional Accessories | Pressure compensation module, dual-channel configuration, AC/DC power adapter |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | NOx5210t |
| Measurement Principle | Electrochemical (Ceramic Zirconia-based Dual-Chamber NOx Sensor) |
| NOx Range | 0–5000 ppm |
| Lambda (λ) Range | 0.4–25 |
| AFR Range | 6–364 |
| Equivalence Ratio (φ) | 0.04–2.5 |
| O₂ Range | 0–25% vol |
| NOx Accuracy | ±15 ppm (0–1000 ppm, NGK), ±20 ppm (0–1000 ppm, NTK Type T), ±30 ppm (0–1000 ppm, NTK) |
| Lambda Accuracy | ±0.008 @ λ=1 |
| Response Time | <1 s (NOx, NGK/NTK-T), 700 ms (NTK), <150 ms (λ/φ/AFR/O₂) |
| Analog Outputs | 6 × 0–5 V (linearized, user-assignable) |
| Digital Interfaces | CAN 2.0B (configurable protocol), USB 2.0, RS-232 |
| Power Supply | 11–28 VDC |
| Operating Temperature | −40 °C to +85 °C |
| Sensor Mounting Thread | 20 mm × 1.5 mm (NGK), 18 mm × 1.5 mm (NTK) |
| Dimensions (H×W×D) | 64 × 105 × 165 mm |
| Weight | 676 g (main unit), 244 g (sensor module) |
| Max Sensor Cable Length | 100 m (standard 4 m included) |
| Fuel Flexibility | Configurable H:C, O:C, N:C, H₂ ratios |
| Optional Features | Dual-channel measurement, pressure compensation, AC/DC adapter |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | NOxCAN |
| Sensor Type | NTK Ceramic NOx Sensor (1), Optional Pressure Sensor (1) |
| Measurement Range | NOx: 0–5000 ppm (λ ≥ 1) |
| Lambda | 0.40–25 |
| AFR | 6.0–364 |
| O₂ | 0–25% vol |
| Pressure | 0–517 kPa (0–75 psia) |
| Accuracy | NOx: ±30 ppm (0–1000 ppm), ±3% FS (other) |
| Lambda | ±0.008 (λ = 1), ±0.016 (λ = 0.8–1.2), ±0.018 (other) |
| AFR | ±0.15 (14.6), ±0.4 (12–18), ±1.0 (other) |
| O₂ | ±0.4% (0–2% O₂), ±0.8% (other) |
| Pressure | ±5.2 kPa (±0.75 psia) |
| Response Time | <700 ms (NOx), <150 ms (Lambda/AFR/O₂) |
| Fuel Composition Parameters | Configurable H:C, O:C, N:C, and H₂ ratios |
| CAN Interface | High-Speed CAN per ISO 11898, User-Assignable Node ID, Multi-Module Bus Support |
| Operating Temperature | −55 °C to +125 °C |
| Dimensions | 145 mm × 120 mm × 40 mm |
| Power Supply | 11–28 VDC |
| Sensor Mounting | 18 mm × 1.5 mm thread (NOx), 1/4" NPT (pressure) |
| Cable Length | Standard 1 m (2 m optional) |
| Calibration | Onboard EEPROM in sensor connector for zero/span calibration data storage |
| Software | PC-based configuration, real-time control, calibration, and parameter monitoring (CAN adapter required, sold separately) |
| Optional Accessories | Analog-output display head (supports up to two NOxCAN modules) |
| Brand | ECM |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | NOxCANg |
| Instrument Type | Online |
| Detection Principle | Electrochemical Sensing |
| Input | 1× NGK-type Ceramic NOx Sensor, 1× Optional Pressure Sensor |
| Range | NOx: 0–5000 ppm (λ > 1) |
| Lambda | 0.40–25 |
| AFR | 6.0–364 |
| O₂ | 0–25% vol |
| Pressure | 0–517 kPa (0–75 psia) |
| Accuracy | NOx: ±15 ppm (0–1000 ppm), ±1.5% FS (other) |
| Lambda | ±0.008 (λ = 1), ±0.016 (λ = 0.8–1.2), ±0.018 (other) |
| AFR | ±0.15 (14.6 AFR), ±0.4 (12–18 AFR), ±1.0 (other) |
| O₂ | ±0.4% (0–2% O₂), ±0.8% (other) |
| Pressure | ±5.2 kPa / ±0.75 psia |
| Response Time | <1 s (NOx), <150 ms (Lambda/AFR/O₂/Φ) |
| Fuel Composition Settings | Adjustable H:C, O:C, N:C, and H₂ ratios |
| CAN Interface | High-Speed CAN per ISO 11898 |
| Configuration | Via CAN bus and PC configuration software (CAN adapter not included) |
| Node ID | User-assignable |
| Dimensions | 145 × 120 × 40 mm |
| IP Rating | IP67 |
| Operating Temperature | −55 °C to +125 °C |
| Sensor Cable | Standard 1 m (2 m optional) |
| Power Supply | 11–28 VDC (AC/DC adapter optional) |
| Sensor Thread | 20 mm × 1.5 mm (NOx), 1/4" NPT (pressure) |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | NOxCANt |
| Communication | High-Speed CAN (ISO 11898) |
| Input | 1× NTK T-type ceramic NOx sensor (18 mm × 1.5 mm thread) + optional pressure sensor (1/4" NPT) |
| Measurement Range | NOx: 0–5000 ppm (λ ≥ 1 and λ < 1) |
| Lambda | 0.40–25 |
| AFR | 6.0–364 |
| O₂ | 0–25% vol |
| Pressure | 0–517 kPa (0–75 psia) |
| Accuracy | NOx: ±20 ppm (0–1000 ppm), ±2% FS (remaining range) |
| Lambda | ±0.008 @ λ=1, ±0.016 @ λ=0.8–1.2, ±0.018 (elsewhere) |
| AFR | ±0.15 @ 14.6, ±0.4 @ 12–18, ±1.0 (elsewhere) |
| O₂ | ±0.4% (0–2% O₂), ±0.8% (elsewhere) |
| Pressure | ±5.2 kPa (±0.75 psia) |
| Response Time | <1 s (NOx), <150 ms (Lambda/AFR/O₂) |
| Fuel Composition Configurability | H:C, O:C, N:C, H₂ ratios user-definable |
| Operating Temperature | −55 °C to +125 °C |
| Dimensions | 145 mm × 120 mm × 40 mm |
| Power Supply | 11–28 VDC |
| Sensor Cable | Standard 1 m (2 m optional) |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | OXY6200 |
| Measurement Range | 0.0–25.0% O₂ |
| Accuracy | ±0.1% FS |
| Response Time | <150 ms |
| Output | Linearized 1.0–5.5 V DC |
| Sensor Thread | M18 × 1.5 mm |
| Dimensions | 102 × 89 × 25 mm |
| Weight | 160 g |
| Power Supply | 11–28 VDC |
| Calibration | Ambient Air (20.95% O₂) |
| Includes | UEGO Sensor, Control Module, 3 m Cable, Mounting Sleeve & Bolt, User Manual |
| Brand | ECM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | pmCAN |
| Instrument Type | Online |
| Measurement Principle | Electrostatic Charge Detection |
| Maximum Permissible Error | ±10% |
| Mass Concentration Range | 0.05–100 mg/m³ |
| Number Concentration Range | 0.24–480 M/cc |
| Installation Thread | M18×1.5 |
| Exhaust Gas Temperature Limit | 850 °C |
| Module Operating Temperature | −55 to 100 °C |
| Cable Temperature Rating | −55 to 220 °C |
| Electronics Dimensions | 114 × 120 × 35 mm |
| Weight | 540 g |
| Enclosure Rating | IP27 |
| Communication Interface | CANopen (configurable baud rate and Node ID) |
| Power Supply | 6–32 VDC, 0.14 A @ 12 V |
| Brand | TCT (Xiamen Tongchuang) |
|---|---|
| Origin | Fujian, China |
| Model | NRPT700(H) |
| Type | Fixed-mount online telematics unit |
| Detection Principle | CAN-bus-based emission data acquisition and OBD-II/EOBD-compliant diagnostic protocol parsing |
| Communication | LTE-FDD/TDD (B1/B3/B5/B8/B38/B39/B40/B41), WCDMA, TD-SCDMA, CDMA, GSM |
| Positioning | GPS & BeiDou dual-mode, sensitivity −162 dBm, horizontal accuracy ≤10 m (open sky), cold start <38 s |
| Environmental Rating | IP67 |
| Operating Temperature | −30 °C to +75 °C |
| Storage Temperature | −40 °C to +85 °C |
| Humidity | 5–95% RH (non-condensing) |
| Power Supply | DC 9–36 V |
| Standby Current | ≤1 mA @ 24 VDC |
| Average Operating Current | ≤55 mA @ 24 VDC |
| Backup Battery Runtime | ≥1 h |
| Compliance | HJ 1014–2018, HJ 1322–2023, GB 20891–2014, GB 17691, GB 32960, DB11/1476, DB11/122 |
| Protocols | SAE J1939, ISO 15765, ISO 27145 (WWH-OBD), ISO 14229 (UDS), ISO 15031 |
| Interfaces | 1–2× CAN, 1× K-Line, 1× L-Line, 1× RS232, 40-pin expansion header |
| Security | CC EAL5+, GM/T 0028–2014 Level 2, AES/DES/SM1/SM2/SM4 support |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | FGA-4100A |
| Pricing | Upon Request |
| Gas Measurement | HC (0–9999 ppm), CO (0–9.99%), CO₂ (0–20%), O₂ (0–25%), NO (0–5000 ppm), λ (0.5–3.0), Oil Temperature (0–150 °C), RPM (250–10000 rpm) |
| Opacity Measurement | N (0–99.9%), k (0–16 m⁻¹) |
| Resolution | HC (1 ppm), CO (0.01% / 0.001%), CO₂ (0.1% / 0.01%), O₂ (0.1% / 0.01%), NO (1 ppm), λ (0.001), Oil Temp (0.1 °C), RPM (1 rpm), N (0.1%), k (0.001 m⁻¹) |
| Accuracy | HC (±12 ppm or ±5%), CO (±0.06% or ±5%), CO₂ (±0.5% or ±5%), O₂ (±0.1% or ±5%), NO (±25 ppm or ±4%), N (±2%) |
| Response Time | HC/CO/CO₂ ≤10 s |
| Warm-up Time | 15 min |
| Power Supply | AC 220 V ±10%, 50 Hz ±1%, 10 A |
| Power Consumption | ~50 W |
| Weight | Main Unit 9 kg (Control Unit 3 kg + Measurement Unit 4.5 kg) |
| Operating Environment | 5–40 °C, RH 0–95% non-condensing |
| Interfaces | RS-232C, RS-485 |
| Data Storage | 300 test records with timestamp, real-time clock, curve logging, optional EOB-D diagnostics, programmable firmware update via serial port |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GB-5030 |
| Price Range | USD 1,400 – 2,800 |
| Instrument Type | Portable |
| Detection Principle | Non-Dispersive Infrared (NDIR) and Electrochemical (O₂, NO) |
| Maximum Permissible Error | ±10% of full scale |
| Zero Drift | ±1% FS / 8 h |
| Span Drift | ±3% FS / 24 h |
| Repeatability | ≤2% RSD |
| Brand | HA-Ai |
|---|---|
| Model | HA-H2 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Detection Principle | Thermal Conductivity Detection (TCD) |
| Maximum Permissible Error | ±1%–±10% FS |
| Zero Drift | ≤1% FS/24h |
| Span Drift | ≤3% FS/24h |
| Repeatability | ≤2% RSD |
| Compliance | GB/T 37154–2018, GB/T 24549–2009 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | MEXA-584L |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Compliance | OIML Class O |
| Weight | ~4 kg |
| Display | Backlit LCD with Icon-Based Interface |
| Communication | RS-232C Serial Port |
| Output | Analog Voltage Signals (0–1 V or 0–5 V) |
| Optional Accessories | Motorcycle Sampling Probe, Oil-Water Separator, Precision Oil Temperature Sensor, Engine RPM Sensor, Thermal Printer |
| Regulatory Certification | PRC Type Approval Certificate for Measuring Instruments |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Infralyt N |
| Instrument Type | Portable |
| Detection Principle | Dual-Mode NDIR + Electrochemical Sensing |
| Maximum Permissible Error | ±1% FS |
| Zero Drift | ±1% FS / 24 h |
| Span Drift | ±1% FS / 24 h |
| Repeatability | ±1% FS |
| Brand | JBS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM/ODM Producer |
| Product Category | Domestic |
| Model | HPC201 |
| Instrument Type | Online Fixed-Mount Analyzer |
| Measurement Principle | Non-Dispersive Infrared (NDIR) for CO |
| Maximum Permissible Error | ±5% of reading |
| Zero Drift | ±3% FS/8h |
| Span Drift | ±3% FS/8h |
| Repeatability | ≤±2% FS |
| Measurement Range | HC: 0–10,000 ppm (v/v) |
| CO | 0–10% (v/v) |
| Accuracy | HC: ±12 ppm or ±5% (whichever greater) |
| CO | ±0.06% or ±5% (whichever greater) |
| Resolution | HC: 1 ppm |
| CO | 0.01% |
| Response Time (t₉₅) | ≤10 s |
| Warm-up Time | 8 min (3 min emergency mode) |
| Operating Environment | –5°C to +50°C, RH ≤90% non-condensing |
| Power Supply | AC 100–240 V, 50/60 Hz or DC 12 V (with optional inverter) |
| Power Consumption | 40 VA |
| Dimensions | 420 × 310 × 170 mm (L×W×H) |
| Weight | ~9 kg |
| Display | High-brightness digital LED |
| Output Interfaces | Built-in thermal printer |
| Auto Functions | Auto-zero calibration |
| Measurement Modes | Free idle and dual-idle testing per GB 18285–2018 and ISO 3930 |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AUTO5-1 |
| Pricing | Available Upon Request |
| Brand | Pegasor |
|---|---|
| Origin | Finland |
| Model | Mi2 |
| Instrument Type | Online |
| Detection Principle | Electrostatic Detection with Integrated Heated Sampling |
| Particle Size Range | ~1 nm – 2.5 µm |
| Mass Concentration Range | 1 µg/m³ – 250 mg/m³ (at T = −20°C to +700°C) |
| Number Concentration Range | 10² – 10⁸ particles/cm³ (derived) |
| Sampling Frequency | 100 Hz (24-bit ADC) |
| Response Time | ≤ 0.2 s |
| Heated Sampling Line | 2 m, maintained at 200 °C |
| Operating Ambient Temperature | −20 °C to +55 °C |
| Power Supply | 24 VDC / 16 A (Mi2 unit) |
| Dimensions (L×W×H) | 798 × 484 × 208 mm |
| Weight | ~29 kg |
| Display | 4-inch color touchscreen |
| Outputs | 4-channel 4–20 mA analog |
| Interface | USB for PPS software connectivity |
| Auto-zero function | Yes |
| Compliance | Designed for EN 16454, ISO 8502-12, and EPA Method 202–compatible deployment in regulatory-grade exhaust monitoring |
| Brand | Pegasor |
|---|---|
| Origin | Finland |
| Model | PPS-M |
| Particle Size Range | ~nm–2.5 µm |
| Mass Concentration Range | 1 µg/m³–500 mg/m³ (dependent on sample gas temperature) |
| Number Concentration | Supported via Faraday cup current differential |
| Response Frequency | Up to 100 Hz |
| Operating Sample Gas Temperature | Standard version up to 200 °C |
| Ambient Temperature Range | −20 °C to +50 °C |
| Sample Gas Pressure | 1–10 bar (absolute) |
| Power Consumption | 6 W |
| Output Interface | USB (standard), analog output optional |
| Sensor Housing Material | Stainless steel |
| Dimensions | 400 mm (length) |
| Weight | 2.6 kg |
| Gas Inlet/Outlet | G1/4″ (inlet), G3/8″ (outlet), G1/8″ (clean air supply) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PMP1000 |
| Pricing Range | USD 135,000–205,000 (FOB) |
| Instrument Type | Online Continuous Monitoring System |
| Measurement Principle | Condensation Particle Counting (CPC) with Volatile Particle Remover (VPR) |
| Maximum Permissible Error | <1% |
| Zero Drift | <1% per 24 h |
| Span Drift | <1% per 24 h |
| Repeatability | <1% (CV) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PM2.5 |
| Instrument Type | Portable |
| Detection Principle | Laser Light Scattering |
| Maximum Permissible Error | ±10% |
| Zero Drift | ±1% FS |
| Span Drift | ±3% |
| Repeatability | ≤2% |
| Measurement Range | 0.001–10 mg/m³ or 0.001–100 mg/m³ |
| Sampling Flow Rate | 2.83 L/min (±2%) |
| Minimum Resolution | 0.001 mg/m³ |
| LOD | 2 µg/m³ |
| Data Interface | RS-232 |
| Display | Real-time LCD with large-format concentration readout |
| Calibration Method | NIST-traceable optical membrane standard |
| Humidity Compensation | Automatic correction under high-humidity conditions |
| [Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PPS |
| Instrument Type | Portable |
| Measurement Principle | Electrospray Ionization + Charged Particle Detection |
| Max. Permissible Error | ±1% FS |
| Zero Drift | ±1% FS/24h |
| Span Drift | ±1% FS/24h |
| Repeatability | ±1% FS] |
| Brand | Ratfisch |
|---|---|
| Origin | Germany |
| Model | RS55-T |
| Measurement Principle | Catalytic Combustion (Flame Ionization Detection alternative configuration available per customization) |
| Range | 0–10 / 100 / 1,000 / 10,000 / 100,000 ppm C₃H₈ (propane-equivalent) |
| Linearity | ±2% of full scale up to 10,000 ppm |
| Cross-sensitivity to O₂ | <±2% of full scale |
| Detection Limit | <2% of lowest full-scale range |
| Zero Drift | <2% FS/week |
| Span Drift | <4% FS/week |
| Response Time (T₉₀) | ~1–2 s (sample line excluded) |
| Sample Flow Rate | ~220 L/h |
| Operating Temperature | +5 °C to +35 °C |
| Power Supply | 230 V / 50 Hz, 800 W |
| Dimensions | 483 mm (W) × 267 mm (H) × 500 mm (D) |
| Weight | ~26.5 kg |
| Certified Compliance | TÜV-certified per German 17. BImSchV |
| EPA Method Compatibility | Compliant with EPA Method 25A and 25B requirements for THC monitoring |
| Output Signals | 0–10 V analog, 0/4–20 mA isolated current loop |
| Status Contacts | Pre-alarm, Alarm, Range Identification, Flame-Out Indication, Calibration Mode (Zero/Gas), System Health (Pressure/Temperature/Flame Monitoring) |
| Brand | SAXON |
|---|---|
| Origin | Germany |
| Model | SMG200M |
| Instrument Type | Portable |
| Measurement Principle | Laser Light Scattering |
| PM Size Range | 40 nm to >10 µm |
| Measurement Range | 0–250 mg/m³ |
| Resolution | 10 µg/m³ ± 1 digit |
| Accuracy | ±5% of full scale |
| Repeatability | ≤±3% |
| Exhaust Gas Temperature Limit | <500 °C |
| Dew Point Tolerance | ≤80 °C |
| Sample Flow Rate | 2.88 L/min (±5%, electronically controlled) |
| Response Time (T90) | <15 s (with 3 m heated line) |
| Zero Calibration Time | 15 s |
| Heating Time | <10 min |
| Data Interfaces | RS232, USB, Bluetooth |
| Display | Color touchscreen |
| Operating Language | English / German |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Power Supply | 230 VAC / 50 Hz, max. 250 VA (including probe) |
| Enclosure | IP40-rated aluminum housing with shock-absorbing rubber edging |
| Dimensions (W×H×D) | approx. 210 × 275 × 375 mm |
| Weight | approx. 7.5 kg |
| Brand | Schütz SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Model | S-ANALYZER 200 NDUV |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Non-Dispersive Ultraviolet (NDUV) Absorption |
| Maximum Permissible Error | ≤ ±2% FS |
| Zero Drift | ≤ ±2% FS / 24 h |
| Span Drift | ≤ ±2% FS / month |
| Repeatability | ≤ ±1% FS |
| Response Time | <25 s (at 60 L/h stable flow) |
| Warm-up Time | 3–30 min (at 20°C, depending on detector configuration) |
| Resolution | 0.01% (O₂ channel), 0.1 µmol/mol (for SO₂/NO/NO₂/etc.) |
| Operating Flow Rate | (0.2–1.2) L/min (±0.02 L/min stability required) |
| Inlet Temperature | 5–35°C |
| Inlet Pressure | ≤116 kPa |
| Dew Point | 5°C ±0.1°C (mandatory for SO₂/NO channels) |
| Particulate Load | ≤100 µg/m³, ≤1 µm |
| Zero Gas | 99.999% N₂ |
| Span Gas | 75–125% of full scale |
| Mid-point Calibration Gas | 37.5–62.5% of full scale |
| Analog Output | 4–20 mA (normal operation), 2 mA (fault/alarm/preheat) |
| Digital Outputs | 6 relay channels (configurable for fault, auto-calibration control, and concentration alarms) |
| Communication | RS232 (DB9 female), RS485 Modbus RTU |
| Power Supply | 198–242 V AC, 50/60 Hz, <125 W |
| Enclosure Rating | IP41 (EN 60529) |
| Weight | ~10 kg (net), ~19 kg (packaged) |
| Display | 5.6" color LCD touchscreen with tri-screen interface (numerical status, detailed parameters, real-time concentration curves) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VEM-100 |
| Instrument Type | Portable |
| Measurement Principle | Optical Transmission (Light Absorption) |
| Max. Permissible Error | ±2.0% |
| Zero Drift | ≤1.0% |
| Span Drift | ≤1.0% |
| Repeatability | ≤1.0% |
| Light Absorption Coefficient (k) Resolution | 0.001 m⁻¹ |
| Opacity (N) Resolution | 0.01% |
| Operating Temperature Compensation | Integrated |
| Optional NOₓ Module | Available |
| Remote Control Interface | Industrial-grade Wi-Fi (up to 100 m) & Bluetooth |
| Data Output | Real-time cloud upload, QR code sharing, thermal printing |
| Dimensions | 470 × 195 × 280 mm |
| Weight | ~7.5 kg |