- All
- Favorite
- Popular
- Most rated
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Dual-Channel Low-Temperature Cryo-Trap, 40-Position |
| Automation Level | Fully Automated |
| Desorption Temperature Range | 150–380 °C |
| Valve Injection Zone Temperature Range | Ambient to 240 °C |
| Transfer Line Temperature Range | Ambient to 240 °C |
| Cryo-Trap Temperature Range | −30 to 50 °C (1 °C increments) |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >95% |
| Sample Capacity | 40 adsorption tubes |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | 50–400 °C |
| Valve Injection Zone Temp Range | Ambient to 200 °C |
| Transfer Line Temp Range | Ambient to 200 °C |
| Cryo-Focusing Trap Temp Range | −35 to 50 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Desorption Recovery Efficiency | ≥98% |
| Sample Capacity | 50 positions |
| Brand | HuaSheng PuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Single-Stage Thermal Desorber |
| Desorption Temperature Range | –30 °C to 400 °C |
| Cold Trap Temperature Range | –30 °C |
| Desorption Recovery Rate | >95% |
| Sample Positions | 20 |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Secondary Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Zone Temperature Range | Ambient to 400 °C |
| Valve Injection Zone Temperature Range | Ambient to 240 °C |
| Transfer Line Temperature Range | Ambient to 240 °C |
| Cold Trap Temperature Range | −30 °C |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >95% |
| Sample Capacity | 20 adsorption tubes (dual-channel configuration) |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Primary Desorption Temp Range | Ambient to 350 °C |
| Valve Inlet Temp Range | Ambient to 220 °C |
| Transfer Line Temp Range | Ambient to 200 °C |
| Cryo-Focusing Trap Temp Range | −35 °C to 50 °C |
| Temperature Control Accuracy | ±1 °C |
| Desorption Recovery Rate | >98% |
| Sample Position Capacity | 1 |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Single-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Sample Zone Temperature Range | Ambient to 400 °C |
| Valve Injection System Temperature Range | Ambient to 180 °C |
| Transfer Line Temperature Range | Ambient to 200 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Desorption Recovery Rate | ≥95% |
| Sample Position Capacity | 1 |
| Dimensions | 170 × 390 × 400 mm |
| Weight | ~10 kg |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 350 °C |
| Secondary Desorption Temp Range | Ambient to 350 °C |
| Valve Inlet Temp Range | Ambient to 220 °C |
| Transfer Line Temp Range | Ambient to 200 °C |
| Cryo-Focusing Trap Temp Range | −30 °C to 50 °C |
| Temperature Control Accuracy | ±1 °C |
| Temperature Resolution | 1 °C |
| Sample Capacity | 30 positions |
| Desorption Recovery Rate | >98% (compound-dependent) |
| Cold Trap Cooling Rate | ≥2500 °C/min |
| Purge Flow Rate | 0–500 mL/min (continuously adjustable) |
| Dimensions | 520 × 520 × 500 mm (W × H × D) |
| Weight | ~45 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ATDS-3600A |
| Price Range | USD 14,000 – 42,000 |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorption Unit |
| Desorption Temperature Range | −30 °C to 400 °C |
| Cold Trap Temperature Range | −30 °C to 50 °C |
| Desorption Recovery Rate | >95% |
| Sample Capacity | 20 positions |
| Temperature Control Accuracy | <±0.1 °C |
| Heating Ramp Rate | >2000 °C/min |
| Carrier Gas Flow | 0–400 mL/min (continuously adjustable) |
| Dimensions | 450 × 360 × 510 mm |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Temperature Range | Ambient to 400 °C |
| Valve Injection Zone Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 240 °C |
| Cold Trap Temperature Range | −35 °C to Ambient |
| Temperature Control Accuracy | ±0.1 °C |
| Analyte Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | ≥10 positions |
Show next