- All
- Favorite
- Popular
- Most rated
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QC-1S |
| Price Range | USD 140–700 (FOB) |
| Instrument Type | Conventional Gas Sampler |
| Configuration | Single-Channel Sampling System |
| Flow Rate Range | 0.1–1.5 L/min |
| Maximum Vacuum Pressure | >26 kPa |
| Flow Stability | ≤±5% |
| Flowmeter Accuracy Class | 2.5 |
| Service Life (at Max Flow & Backpressure) | 5–10 Years |
| Continuous Operation Duration (at Max Flow & Rated Resistance) | 2–8 h |
| Load Capacity | >1 L/min at 4 kPa Backpressure |
| Timing Accuracy | <0.1% |
| Operating Temperature | −10 to +45 °C |
| Dimensions (W×H×D) | 100 × 150 × 52 mm |
| Net Weight (incl. Rechargeable Battery) | 550 g |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | DYM3 |
| Pricing | Upon Request |
| Pressure Range | 800–1064 hPa |
| Operating Temperature | −10 to +40 °C |
| Temperature Scale Range | −11 to +41 °C |
| Max. Pressure Error (after correction) | ≤2.0 hPa |
| Pressure Scale Division | 1 hPa |
| Temperature Scale Division | 1 °C |
| Weight | ≤1.5 kg |
| Dimensions | 156 mm × 156 mm × 115 mm |
| Standard Package | 1 unit barometer, 1 instruction manual, 1 certificate of conformity, 1 protective carrying case |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | HD-2001 |
| Instrument Type | Gamma Spectrometer |
| Detector | Ø75 × 75 mm NaI(Tl) Scintillation Crystal |
| Total Channels | Selectable (512 / 1024 / 2048 / 4096), Default Operational Configuration: 2048 channels |
| Energy Resolution | <7.5% at 662 keV (¹³⁷Cs) |
| Differential Nonlinearity | <0.05% |
| Integral Nonlinearity | <0.1% |
| Max. Throughput | >333 kcps |
| Pulse Pile-up Rejection | 500 ns |
| Measurement Uncertainty | <10% (for sample activity >37 Bq/kg) |
| Radionuclide Quantification Ranges | ²³⁸U (37–1×10⁶ Bq/kg), ²²⁶Ra (37–1×10⁶ Bq/kg), ²³²Th (12–4×10⁵ Bq/kg), ⁴⁰K (0.1–100 wt%), Air Radon (4–100,000 Bq/m³), Soil Radon (300–200,000 Bq/m³) |
| Operating Environment | 5–40 °C, ≤90% RH, 220 V ±10%, 50 Hz |
| Lead Shielding Chamber | Ø580 × 850 mm, Wall Thickness: 100 mm, Mass: ~900 kg |
| Compliance | GB 6566–2010, GB 50325–2010, JJG 417–2019 (Calibration Verified by National Institute of Metrology, China) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QC-2B |
| Price Range | USD 140–700 (FOB) |
| Instrument Type | Conventional Gas Sampler |
| Configuration | Dual-Independent-Channel Sampling System |
| Flow Range | 0.1–1.5 L/min |
| Maximum Vacuum Pressure | >26 kPa |
| Flow Stability | ≤5% |
| Flowmeter Accuracy Class | 2.5 |
| Service Life Under Max Load & Backpressure | 5–10 years |
| Continuous Operation Duration at Max Flow & Rated Resistance | 2–8 h |
| Rated Flow | 2.5 L/min @ 4.5 kPa Backpressure |
| Timing Range | 1–99 h (adjustable in 1-min increments) |
| Timing Accuracy | ≤0.01% (based on real-time clock) |
| Dimensions | 210 × 125 × 95 mm |
| Power Supply | AC/DC dual-mode (rechargeable Ni-MH battery included) |
| Battery Runtime | ≥6 h continuous operation |
| Operating Temperature | −10 °C to +40 °C |
| Net Weight | 2.8 kg (including battery) |
| Control Architecture | Dual-channel independent electronic timer with synchronized start/stop capability |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | 24-Hour Temperature- and Flow-Controlled Gas Sampler |
| Configuration | Dual-Channel Sampling System |
| Flow Range | 0.4–0.6 L/min |
| Maximum Vacuum Pressure | >20,000 Pa |
| Load Capacity | >0.6 L/min at 10,000 Pa |
| Flow Stability | ≤5% |
| Flowmeter Accuracy | ≤±5% (within 6,000 Pa backpressure) |
| Timer Range | 1–99 min (timing error <0.1%) |
| Power Supply | AC 220 V, 50 Hz / DC 7.4 V Li-ion rechargeable battery |
| Continuous Operation Time | ≥6 h (battery-powered) |
| Operating Temperature | −10 °C to +45 °C |
| Dimensions | 210 × 125 × 80 mm |
| Weight (incl. battery) | 1470 g |
| Rated Service Life at Max Flow & Resistance | 5000 h |
| Runtime at Max Flow & Max Resistance | 2–8 h |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BS-H2 |
| Quotation | USD 920 (FOB Beijing) |
| Instrument Type | 24-Hour Temperature- and Flow-Controlled Gas Sampler |
| Instrument Configuration | Dual-Independent Sampling Channels |
| Flow Range | 100–500 sccm |
| Maximum Vacuum Pressure | >26 kPa |
| Flow Stability | ≤±1% FS |
| Flowmeter Accuracy | ±2.5% FS |
| Service Life Under Max Load & Resistance | 5–10 years |
| Continuous Operation Duration at Max Flow & Backpressure | 2–8 h |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QC-2 / QC-2A |
| Price Range | USD 140–700 |
| Instrument Type | Conventional Gas Sampler |
| Configuration | Dual-Channel Portable Sampler |
| Flow Rate Range | 0.1–1.5 L/min |
| Maximum Vacuum Pressure | >26 kPa |
| Flow Stability | ≤5% fluctuation (under load) |
| Flowmeter Accuracy | Class 2.5 (per GB/T 1226–2017 / equivalent to ISO 5167 Class 2.5) |
| Service Life (at max flow & resistance) | 5–10 years |
| Continuous Operation Duration (at max flow & 4.5 kPa backpressure) | 2–8 h |
| Timer Range | 1–99 min, timing error <0.1% |
| Power Supply | AC/DC dual-mode |
| Dimensions | 210 × 125 × 95 mm |
| Weight | 2.9 kg |
| Pump Type | Diaphragm vacuum pump (QC-2A variant features high-torque diaphragm pump optimized for VOC sampling with elevated backpressure tolerance) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sensidyne IAQ-Pro |
| Instrument Type | 24-Hour Isothermal & Isokinetic Gas Sampler |
| Instrument Configuration | Dual-Channel Air Sampler |
| Flow Range | 100–600 cc/min |
| Maximum Vacuum Pressure | >26 kPa |
| Flow Stability | ≤ ±5% |
| Flowmeter Accuracy | ≥ ±2.5% |
| Service Life at Max Flow & Backpressure | ≥5000 h |
| Continuous Operation Duration at Max Flow & Max Backpressure | 2–8 h |
Show next