| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Vial Heating Range | 20°C to 200°C |
| Valve & Transfer Line Temperature Control Range | 20°C to 240°C |
| Sample Loop Volume | 1 mL |
| Temperature Control Accuracy | ±0.1°C |
| Vial Capacity | 40 positions |
| Vial Format | 20 mL standard headspace vials |
| Dimensions (W×D×H) | 530 × 680 × 655 mm |
| Weight | ~50 kg |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Dual-Channel Low-Temperature Cryo-Trap, 40-Position |
| Automation Level | Fully Automated |
| Desorption Temperature Range | 150–380 °C |
| Valve Injection Zone Temperature Range | Ambient to 240 °C |
| Transfer Line Temperature Range | Ambient to 240 °C |
| Cryo-Trap Temperature Range | −30 to 50 °C (1 °C increments) |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >95% |
| Sample Capacity | 40 adsorption tubes |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | 50–400 °C |
| Valve Injection Zone Temp Range | Ambient to 200 °C |
| Transfer Line Temp Range | Ambient to 200 °C |
| Cryo-Focusing Trap Temp Range | −35 to 50 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Desorption Recovery Efficiency | ≥98% |
| Sample Capacity | 50 positions |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | PT-3900A |
| Sample Tray Capacity | 84 positions |
| Temperature Control Accuracy | ±0.1°C |
| Trap Desorption Temperature Range | 100–350°C |
| Sample Heating Temperature (Purge Vessel) | up to 250°C |
| Sample Vial Cooling Temperature Range | 0–40°C |
| Water Removal Trap Temp Range | Ambient–200°C |
| Valve & Transfer Line Temp Range | Ambient–250°C |
| Trap Cryo-Focusing Temp Range | 0–40°C |
| Sample Oven Temp Range | Ambient–90°C |
| Hot Water Bath Temp Range | Ambient–90°C |
| Purge Tube Temp Range | Ambient–90°C |
| Desorption Ramp Rate | >2000°C/min |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HTB-3420 |
| Temperature Control Range | Ambient to 400 °C |
| Tube Capacity | 1–20 tubes |
| Temperature Setting Increment | 1 °C |
| Temperature Accuracy | ±0.5% of setpoint |
| Temperature Uniformity | ±1 °C across chamber |
| Timer Range | 0–99 h 99 min, continuously adjustable |
| Tube Compatibility | Outer diameter 6 mm (¼ inch), unlimited length |
| Brand | HuaSheng PuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Single-Stage Thermal Desorber |
| Desorption Temperature Range | –30 °C to 400 °C |
| Cold Trap Temperature Range | –30 °C |
| Desorption Recovery Rate | >95% |
| Sample Positions | 20 |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HS-6D |
| Pricing | Available Upon Request |
| Flow Control | Mass Flow Controllers (MFCs) |
| Display | 7-inch Capacitive Touchscreen |
| Gas Path Materials | Passivated Stainless Steel Tubing & PTFE Tubing |
| Built-in Pump | Diaphragm Pump for Ambient-Pressure Gas Sampling |
| Dilution Range | 1:1 to 1:100 (customizable) |
| Output Channels | 6 Independent Concentration Ports |
| Operation Modes | Single-point or Multi-step Sequential Dilution |
| Method Storage | Onboard Method Library with Recall Function |
| Software Interface | Single- or Multi-channel Configuration Support |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Secondary Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Zone Temperature Range | Ambient to 400 °C |
| Valve Injection Zone Temperature Range | Ambient to 240 °C |
| Transfer Line Temperature Range | Ambient to 240 °C |
| Cold Trap Temperature Range | −30 °C |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >95% |
| Sample Capacity | 20 adsorption tubes (dual-channel configuration) |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TDS-3410A |
| Temperature Control Range | Ambient to 400 °C |
| Gas Flow Rate | 0–300 mL/min |
| Tube Capacity | 6–10 tubes |
| Temperature Setting Increment | 1 °C |
| Temperature Stability | ±0.5% of setpoint |
| Timer Range | 0–655 minutes |
| Power Consumption | <500 W |
| Dimensions (W×D×H) | 170×390×400 mm |
| Weight | ~8 kg |
| Brand | HuaShengPuXin |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ATDS-6000 |
| Instrument Category | GC Autosampler with Cryogenic Trapping |
| Max Sample Capacity | 6 positions |
| Valve Injection System Temp Range | RT–220°C (1°C increments) |
| Transfer Line Temp Range | RT–240°C (1°C increments, low-voltage heating) |
| Desorption Temp Range | RT–350°C (1°C increments, >1000°C/min ramp rate) |
| Cryo-Trap Temp Range | −50°C to +50°C (1°C increments, solid-state electronic cooling) |
| Dimensions | 465 × 220 × 380 mm |
| Power Consumption | 500 W |
| Weight | ~20 kg |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Primary Desorption Temp Range | Ambient to 350 °C |
| Valve Inlet Temp Range | Ambient to 220 °C |
| Transfer Line Temp Range | Ambient to 200 °C |
| Cryo-Focusing Trap Temp Range | −35 °C to 50 °C |
| Temperature Control Accuracy | ±1 °C |
| Desorption Recovery Rate | >98% |
| Sample Position Capacity | 1 |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HS-30A |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 30 positions |
| Vial Size Options | 10 mL or 20 mL standard headspace vials |
| Oven Temperature Range | Ambient to 240 °C (1 °C increment, ±0.1 °C accuracy, ~400 W heating power) |
| Valve & Transfer Line Temperature Range | Ambient to 240 °C (1 °C increment, ±0.1 °C accuracy |
| valve | ~100 W, transfer line: ~200 W) |
| Dimensions (W×D×H) | 460 × 450 × 520 mm |
| Weight | ~38 kg |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | PT-3600A |
| Instrument Type | Water-and-Soil Integrated Purge and Trap System |
| Sample Tray Capacity | ≥30 positions |
| Trap Tube Temperature Range | Ambient to 350 °C |
| Sample Heating Temperature Range | Ambient to 90 °C |
| Water Trap Temperature Range | Ambient to 200 °C |
| Valve & Transfer Line Temperature Range | Ambient to 250 °C |
| Desorption Ramp Rate | >2000 °C/min |
| Temperature Control Accuracy | < ±0.5 °C |
| Temperature Uniformity Gradient | < ±1 °C |
| Vial Format | 40 mL |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Single-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Sample Zone Temperature Range | Ambient to 400 °C |
| Valve Injection System Temperature Range | Ambient to 180 °C |
| Transfer Line Temperature Range | Ambient to 200 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Desorption Recovery Rate | ≥95% |
| Sample Position Capacity | 1 |
| Dimensions | 170 × 390 × 400 mm |
| Weight | ~10 kg |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 20 positions |
| Vial Sizes Supported | 10 mL and 20 mL standard crimp-top headspace vials |
| Valve & Loop Temperature Range | Ambient to 200 °C |
| Quantitative Loop Volume | 1 mL |
| Temperature Control Accuracy | < ±0.1 °C |
| Sample Zone Temperature Range | Ambient to 260 °C |
| Transfer Line Temperature Range | Ambient to 200 °C |
| Power Supply | 220–240 V AC, 50–60 Hz |
| Operating Environment | 10–35 °C, 10–90% RH (non-condensing) |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 350 °C |
| Secondary Desorption Temp Range | Ambient to 350 °C |
| Valve Inlet Temp Range | Ambient to 220 °C |
| Transfer Line Temp Range | Ambient to 200 °C |
| Cryo-Focusing Trap Temp Range | −30 °C to 50 °C |
| Temperature Control Accuracy | ±1 °C |
| Temperature Resolution | 1 °C |
| Sample Capacity | 30 positions |
| Desorption Recovery Rate | >98% (compound-dependent) |
| Cold Trap Cooling Rate | ≥2500 °C/min |
| Purge Flow Rate | 0–500 mL/min (continuously adjustable) |
| Dimensions | 520 × 520 × 500 mm (W × H × D) |
| Weight | ~45 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ATDS-3600A |
| Price Range | USD 14,000 – 42,000 |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorption Unit |
| Desorption Temperature Range | −30 °C to 400 °C |
| Cold Trap Temperature Range | −30 °C to 50 °C |
| Desorption Recovery Rate | >95% |
| Sample Capacity | 20 positions |
| Temperature Control Accuracy | <±0.1 °C |
| Heating Ramp Rate | >2000 °C/min |
| Carrier Gas Flow | 0–400 mL/min (continuously adjustable) |
| Dimensions | 450 × 360 × 510 mm |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Capacity | 12 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Oven Temperature Range | Ambient to 220 °C |
| Valve & Loop Temperature Range | Ambient to 180 °C |
| Sample Transfer Line Temperature Range | Ambient to 200 °C |
| Quantitative Loop Volume | 1–2 mL (adjustable) |
| Temperature Control Accuracy | < ±0.5 °C |
| Temperature Uniformity (Gradient) | < ±0.5 °C |
| Dimensions (W×D×H) | 400 × 200 × 380 mm |
| Weight | 15.5 kg |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Capacity | 150-position or 100-position vial carousel |
| Compliance | ASTM D6866, ISO 17025-aligned operation, GLP/GMP-ready data handling |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LJ-100 |
| Instrument Type | Tube-Furnace Pyrolyzer |
| Pyrolysis Cell Temp Range | 5–400 °C (1 °C increment) |
| Probe Temp Range | 300–1200 °C (10 °C increment), 5-step programmable ramp |
| Probe Heating Rate | 0.01–20 °C/ms (11 selectable steps) |
| Probe Hold Time | 10 ms–99 s (10 ms increment) |
| Cleaning Temp | 1200 °C for 5 s |
| Dimensions | 387 × 245 × 130 mm (L×W×H) |
| Power | 250 W |
| Weight | 7 kg |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | PT-4000 |
| Sample Tray Capacity | 100 positions |
| Injection Precision | RSD < 1% |
| Trap Temperature Range | Ambient to 350 °C |
| Sample Heating Temperature Range (Purge Zone) | Ambient to 90 °C |
| Application Class | Water and Soil VOC Analysis |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Temperature Range | Ambient to 400 °C |
| Valve Injection Zone Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 240 °C |
| Cold Trap Temperature Range | −35 °C to Ambient |
| Temperature Control Accuracy | ±0.1 °C |
| Analyte Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | ≥10 positions |