BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeDynamic Headspace Sampler
Automation LevelFully Automated
Sample Vial Heating Range20°C to 200°C
Valve & Transfer Line Temperature Control Range20°C to 240°C
Sample Loop Volume1 mL
Temperature Control Accuracy±0.1°C
Vial Capacity40 positions
Vial Format20 mL standard headspace vials
Dimensions (W×D×H)530 × 680 × 655 mm
Weight~50 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelDual-Channel Low-Temperature Cryo-Trap, 40-Position
Automation LevelFully Automated
Desorption Temperature Range150–380 °C
Valve Injection Zone Temperature RangeAmbient to 240 °C
Transfer Line Temperature RangeAmbient to 240 °C
Cryo-Trap Temperature Range−30 to 50 °C (1 °C increments)
Temperature Control Accuracy±1 °C
Analyte Recovery Rate>95%
Sample Capacity40 adsorption tubes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeTwo-Stage Thermal Desorber
Automation LevelFully Automated
Primary Desorption Temp Range50–400 °C
Valve Injection Zone Temp RangeAmbient to 200 °C
Transfer Line Temp RangeAmbient to 200 °C
Cryo-Focusing Trap Temp Range−35 to 50 °C
Temperature Control Accuracy±0.1 °C
Desorption Recovery Efficiency≥98%
Sample Capacity50 positions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic
ModelPT-3900A
Sample Tray Capacity84 positions
Temperature Control Accuracy±0.1°C
Trap Desorption Temperature Range100–350°C
Sample Heating Temperature (Purge Vessel)up to 250°C
Sample Vial Cooling Temperature Range0–40°C
Water Removal Trap Temp RangeAmbient–200°C
Valve & Transfer Line Temp RangeAmbient–250°C
Trap Cryo-Focusing Temp Range0–40°C
Sample Oven Temp RangeAmbient–90°C
Hot Water Bath Temp RangeAmbient–90°C
Purge Tube Temp RangeAmbient–90°C
Desorption Ramp Rate>2000°C/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHSPX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelHTB-3420
Temperature Control RangeAmbient to 400 °C
Tube Capacity1–20 tubes
Temperature Setting Increment1 °C
Temperature Accuracy±0.5% of setpoint
Temperature Uniformity±1 °C across chamber
Timer Range0–99 h 99 min, continuously adjustable
Tube CompatibilityOuter diameter 6 mm (¼ inch), unlimited length
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaSheng PuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSingle-Stage Thermal Desorber
Desorption Temperature Range–30 °C to 400 °C
Cold Trap Temperature Range–30 °C
Desorption Recovery Rate>95%
Sample Positions20
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHSPX
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelHS-6D
PricingAvailable Upon Request
Flow ControlMass Flow Controllers (MFCs)
Display7-inch Capacitive Touchscreen
Gas Path MaterialsPassivated Stainless Steel Tubing & PTFE Tubing
Built-in PumpDiaphragm Pump for Ambient-Pressure Gas Sampling
Dilution Range1:1 to 1:100 (customizable)
Output Channels6 Independent Concentration Ports
Operation ModesSingle-point or Multi-step Sequential Dilution
Method StorageOnboard Method Library with Recall Function
Software InterfaceSingle- or Multi-channel Configuration Support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSecondary Thermal Desorber
Automation LevelFully Automated
Desorption Zone Temperature RangeAmbient to 400 °C
Valve Injection Zone Temperature RangeAmbient to 240 °C
Transfer Line Temperature RangeAmbient to 240 °C
Cold Trap Temperature Range−30 °C
Temperature Control Accuracy±1 °C
Analyte Recovery Rate>95%
Sample Capacity20 adsorption tubes (dual-channel configuration)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHSPX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelTDS-3410A
Temperature Control RangeAmbient to 400 °C
Gas Flow Rate0–300 mL/min
Tube Capacity6–10 tubes
Temperature Setting Increment1 °C
Temperature Stability±0.5% of setpoint
Timer Range0–655 minutes
Power Consumption<500 W
Dimensions (W×D×H)170×390×400 mm
Weight~8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelATDS-6000
Instrument CategoryGC Autosampler with Cryogenic Trapping
Max Sample Capacity6 positions
Valve Injection System Temp RangeRT–220°C (1°C increments)
Transfer Line Temp RangeRT–240°C (1°C increments, low-voltage heating)
Desorption Temp RangeRT–350°C (1°C increments, >1000°C/min ramp rate)
Cryo-Trap Temp Range−50°C to +50°C (1°C increments, solid-state electronic cooling)
Dimensions465 × 220 × 380 mm
Power Consumption500 W
Weight~20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeTwo-Stage Thermal Desorber
Automation LevelSemi-Automatic
Primary Desorption Temp RangeAmbient to 350 °C
Valve Inlet Temp RangeAmbient to 220 °C
Transfer Line Temp RangeAmbient to 200 °C
Cryo-Focusing Trap Temp Range−35 °C to 50 °C
Temperature Control Accuracy±1 °C
Desorption Recovery Rate>98%
Sample Position Capacity1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelHS-30A
Automation LevelFully Automated
Sample Tray Capacity30 positions
Vial Size Options10 mL or 20 mL standard headspace vials
Oven Temperature RangeAmbient to 240 °C (1 °C increment, ±0.1 °C accuracy, ~400 W heating power)
Valve & Transfer Line Temperature RangeAmbient to 240 °C (1 °C increment, ±0.1 °C accuracy
valve~100 W, transfer line: ~200 W)
Dimensions (W×D×H)460 × 450 × 520 mm
Weight~38 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic
ModelPT-3600A
Instrument TypeWater-and-Soil Integrated Purge and Trap System
Sample Tray Capacity≥30 positions
Trap Tube Temperature RangeAmbient to 350 °C
Sample Heating Temperature RangeAmbient to 90 °C
Water Trap Temperature RangeAmbient to 200 °C
Valve & Transfer Line Temperature RangeAmbient to 250 °C
Desorption Ramp Rate>2000 °C/min
Temperature Control Accuracy< ±0.5 °C
Temperature Uniformity Gradient< ±1 °C
Vial Format40 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSingle-Stage Thermal Desorber
Automation LevelSemi-Automatic
Sample Zone Temperature RangeAmbient to 400 °C
Valve Injection System Temperature RangeAmbient to 180 °C
Transfer Line Temperature RangeAmbient to 200 °C
Temperature Control Accuracy±0.1 °C
Desorption Recovery Rate≥95%
Sample Position Capacity1
Dimensions170 × 390 × 400 mm
Weight~10 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automated
Sample Tray Capacity20 positions
Vial Sizes Supported10 mL and 20 mL standard crimp-top headspace vials
Valve & Loop Temperature RangeAmbient to 200 °C
Quantitative Loop Volume1 mL
Temperature Control Accuracy< ±0.1 °C
Sample Zone Temperature RangeAmbient to 260 °C
Transfer Line Temperature RangeAmbient to 200 °C
Power Supply220–240 V AC, 50–60 Hz
Operating Environment10–35 °C, 10–90% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeTwo-Stage Thermal Desorber
Automation LevelFully Automated
Primary Desorption Temp RangeAmbient to 350 °C
Secondary Desorption Temp RangeAmbient to 350 °C
Valve Inlet Temp RangeAmbient to 220 °C
Transfer Line Temp RangeAmbient to 200 °C
Cryo-Focusing Trap Temp Range−30 °C to 50 °C
Temperature Control Accuracy±1 °C
Temperature Resolution1 °C
Sample Capacity30 positions
Desorption Recovery Rate>98% (compound-dependent)
Cold Trap Cooling Rate≥2500 °C/min
Purge Flow Rate0–500 mL/min (continuously adjustable)
Dimensions520 × 520 × 500 mm (W × H × D)
Weight~45 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelATDS-3600A
Price RangeUSD 14,000 – 42,000
Instrument TypeTwo-Stage Thermal Desorber / Thermal Desorption Unit
Desorption Temperature Range−30 °C to 400 °C
Cold Trap Temperature Range−30 °C to 50 °C
Desorption Recovery Rate>95%
Sample Capacity20 positions
Temperature Control Accuracy<±0.1 °C
Heating Ramp Rate>2000 °C/min
Carrier Gas Flow0–400 mL/min (continuously adjustable)
Dimensions450 × 360 × 510 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeStatic Headspace Sampler
Automation LevelSemi-Automatic
Sample Vial Capacity12 positions
Vial Sizes Supported10 mL and 20 mL
Oven Temperature RangeAmbient to 220 °C
Valve & Loop Temperature RangeAmbient to 180 °C
Sample Transfer Line Temperature RangeAmbient to 200 °C
Quantitative Loop Volume1–2 mL (adjustable)
Temperature Control Accuracy< ±0.5 °C
Temperature Uniformity (Gradient)< ±0.5 °C
Dimensions (W×D×H)400 × 200 × 380 mm
Weight15.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeDynamic Headspace Sampler
Automation LevelFully Automated
Sample Capacity150-position or 100-position vial carousel
ComplianceASTM D6866, ISO 17025-aligned operation, GLP/GMP-ready data handling
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelLJ-100
Instrument TypeTube-Furnace Pyrolyzer
Pyrolysis Cell Temp Range5–400 °C (1 °C increment)
Probe Temp Range300–1200 °C (10 °C increment), 5-step programmable ramp
Probe Heating Rate0.01–20 °C/ms (11 selectable steps)
Probe Hold Time10 ms–99 s (10 ms increment)
Cleaning Temp1200 °C for 5 s
Dimensions387 × 245 × 130 mm (L×W×H)
Power250 W
Weight7 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic
ModelPT-4000
Sample Tray Capacity100 positions
Injection PrecisionRSD < 1%
Trap Temperature RangeAmbient to 350 °C
Sample Heating Temperature Range (Purge Zone)Ambient to 90 °C
Application ClassWater and Soil VOC Analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeTwo-Stage Thermal Desorber
Automation LevelFully Automated
Desorption Temperature RangeAmbient to 400 °C
Valve Injection Zone Temperature RangeAmbient to 220 °C
Transfer Line Temperature RangeAmbient to 240 °C
Cold Trap Temperature Range−35 °C to Ambient
Temperature Control Accuracy±0.1 °C
Analyte Recovery Rate>98% (compound-dependent)
Sample Capacity≥10 positions