| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Vial Heating Range | 20°C to 200°C |
| Valve & Transfer Line Temperature Control Range | 20°C to 240°C |
| Sample Loop Volume | 1 mL |
| Temperature Control Accuracy | ±0.1°C |
| Vial Capacity | 40 positions |
| Vial Format | 20 mL standard headspace vials |
| Dimensions (W×D×H) | 530 × 680 × 655 mm |
| Weight | ~50 kg |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry Dedicated |
| Oven Temperature Range | Ambient +5°C to 400°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Oven Cool-down Time | ~6 minutes (from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HSPX |
|---|---|
| Origin | China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical Residue Analysis |
| Temperature Control Range | Ambient +5°C to 400°C |
| Oven Ramp Rate | 0.1–39.9°C/min |
| Cool-down Time | ~6 min (from 400°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Dual-Channel Low-Temperature Cryo-Trap, 40-Position |
| Automation Level | Fully Automated |
| Desorption Temperature Range | 150–380 °C |
| Valve Injection Zone Temperature Range | Ambient to 240 °C |
| Transfer Line Temperature Range | Ambient to 240 °C |
| Cryo-Trap Temperature Range | −30 to 50 °C (1 °C increments) |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >95% |
| Sample Capacity | 40 adsorption tubes |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | Refinery Gas-Specific GC |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detectors | TCD and FID |
| Column Types | Packed and Capillary |
| Multi-Valve Auto-Switching | Yes |
| Signal Auto-Switching | Yes |
| Analysis Scope | H₂, O₂, N₂, CO₂, CO, C₁–C₆₀ hydrocarbons (including C₂=–C₄= olefins and C₆⁺ saturates/olefins/aromatics) |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Medical Device Sterilization Validation & Clinical Diagnostics |
| Temperature Control Range | Ambient +4 °C to 450 °C (1 °C increment, ±0.01 °C accuracy) |
| Oven Ramp Rate | 0.1–39 °C/min (standard), 0.1–80 °C/min (high-speed option) |
| Cooling Rate | 450 °C → 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Zones | 8 independently controlled zones |
| Programmable Temperature Ramping | Up to 16 steps |
| External Event Inputs | 6 channels |
| Auxiliary Control Outputs | 2 channels |
| Injector Compatibility | Packed column, capillary column, 6-port gas valve, automated thermal desorption, purge-and-trap, and headspace sampling (HS-20A, HS-10A, or HS-12A optional) |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal (Mine Safety & Gas Monitoring) |
| Oven Temperature Range | Ambient +12 °C to 400 °C |
| Oven Ramp Rate | 0.1–39 °C/min (Standard) |
| Oven Cooling Rate | ~6 min from 450 °C to 50 °C |
| Carrier Gas Flow Control Range | 0–1000 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detectors | TCD (MDL ≤9×10⁻⁶ mg/mL in H₂, n-C₁₆), FID (MDL ≤8×10⁻¹² g/s, n-C₁₆), ECD (MDL ≤0.1 pg, γ-BHC), FPD ([P] ≤1×10⁻¹² g/s, TBP |
| Column Configuration | Packed-column system with methanizer and automated 6-port valve for simultaneous O₂/N₂/CH₄/CO/CO₂ analysis |
| Detection Ranges | O₂ (20.9±5%), N₂ (78±10%), CH₄ (0.5 ppm–10%), CO (0.5 ppm–0.3%), CO₂ (1 ppm–0.5%), C₂H₆/C₂H₄/C₂H₂ (1 ppm–0.3%) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | 1650 W |
| Net Weight | ~50 kg |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | 50–400 °C |
| Valve Injection Zone Temp Range | Ambient to 200 °C |
| Transfer Line Temp Range | Ambient to 200 °C |
| Cryo-Focusing Trap Temp Range | −35 to 50 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Desorption Recovery Efficiency | ≥98% |
| Sample Capacity | 50 positions |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | AA2630 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Diffraction Grating (1800 grooves/mm) |
| Optical System | Double-Beam |
| Detector | High-Sensitivity Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal (Auto-Adjusting) |
| Spectral Bandwidth | 0.1 / 0.2 / 0.4 / 1.0 / 2.0 nm (5-step motorized selection) |
| Resolution | ≤0.3 nm (meets Mn 279.5/279.8 nm separation criterion, valley-to-peak energy ratio <20%) |
| Sensitivity (Cu) | >0.3 A at 5 ppm |
| RSD (Precision) | <0.3% (Flame), ≤3% (Graphite Furnace) |
| Detection Limit (Cu, Flame) | 0.005 µg/mL |
| Detection Limit (Cd, GF-AAS) | 1.0 × 10⁻¹² g |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | PT-3900A |
| Sample Tray Capacity | 84 positions |
| Temperature Control Accuracy | ±0.1°C |
| Trap Desorption Temperature Range | 100–350°C |
| Sample Heating Temperature (Purge Vessel) | up to 250°C |
| Sample Vial Cooling Temperature Range | 0–40°C |
| Water Removal Trap Temp Range | Ambient–200°C |
| Valve & Transfer Line Temp Range | Ambient–250°C |
| Trap Cryo-Focusing Temp Range | 0–40°C |
| Sample Oven Temp Range | Ambient–90°C |
| Hot Water Bath Temp Range | Ambient–90°C |
| Purge Tube Temp Range | Ambient–90°C |
| Desorption Ramp Rate | >2000°C/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | Baijiu-Specific |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down | 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaSheng Puxin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Focus | Petrochemical & Liquefied Petroleum Gas (LPG) Analysis |
| Temperature Control Range | Ambient +5°C to 400°C |
| Ramp Rate | 0.1–40°C/min |
| Cool-down Time | ~6 min (from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Baijiu (Chinese Liquor) Analysis |
| Temperature Control Range | 20 °C to 450 °C |
| Temperature Ramp Rate | 0.1–80 °C/min |
| Cooling Rate | Up to 39.9 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Zones | 8 independently controlled zones |
| Temperature Accuracy | ±0.01 °C |
| Minimum Temperature Increment | 1 °C |
| Programmable Temperature Program | Multi-step (≥8 stages) |
| External Event Inputs | 6 channels |
| Auxiliary Outputs | 2 channels |
| Injector Options | Packed column, capillary column, 6-port gas valve, automatic thermal desorption, purge-and-trap, and headspace sampling |
| Detector Capacity | Up to 3 detectors simultaneously |
| Detector Options | FID, TCD, ECD, FPD, NPD |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Clinical Toxicology & Forensic Medical Testing |
| Temperature Control Range | Ambient + 5°C to 400°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Cool-down Time | ~6 min (from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Zones | 8 independently controlled zones |
| Temperature Accuracy | ±0.01°C |
| Max Programmed Ramp Stages | 16 |
| External Event Inputs | 6 channels |
| Auxiliary Outputs | 2 channels |
| Detector Capacity | Up to 3 simultaneous detectors (FID, TCD, ECD, FPD, NPD configurable) |
| Injector Options | Packed column, capillary column, 6-port gas valve, automated headspace, purge-and-trap, thermal desorption |
| Software | Dual-language (English/Chinese) GC workstation with audit trail, method validation support, and CFR Part 11–compliant data integrity features |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HTB-3420 |
| Temperature Control Range | Ambient to 400 °C |
| Tube Capacity | 1–20 tubes |
| Temperature Setting Increment | 1 °C |
| Temperature Accuracy | ±0.5% of setpoint |
| Temperature Uniformity | ±1 °C across chamber |
| Timer Range | 0–99 h 99 min, continuously adjustable |
| Tube Compatibility | Outer diameter 6 mm (¼ inch), unlimited length |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | GC-BA1000 |
| Price Range | USD 4,200–7,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Beverage Quality Control & Regulatory Compliance |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cooling Rate | From 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin/HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | LPG-Dedicated |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Rate | 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaSheng PuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Single-Stage Thermal Desorber |
| Desorption Temperature Range | –30 °C to 400 °C |
| Cold Trap Temperature Range | –30 °C |
| Desorption Recovery Rate | >95% |
| Sample Positions | 20 |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HS-6D |
| Pricing | Available Upon Request |
| Flow Control | Mass Flow Controllers (MFCs) |
| Display | 7-inch Capacitive Touchscreen |
| Gas Path Materials | Passivated Stainless Steel Tubing & PTFE Tubing |
| Built-in Pump | Diaphragm Pump for Ambient-Pressure Gas Sampling |
| Dilution Range | 1:1 to 1:100 (customizable) |
| Output Channels | 6 Independent Concentration Ports |
| Operation Modes | Single-point or Multi-step Sequential Dilution |
| Method Storage | Onboard Method Library with Recall Function |
| Software Interface | Single- or Multi-channel Configuration Support |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Industry Dedicated |
| Column Oven Temperature Range | Ambient + 5°C to 400°C |
| Ramp Rate | 0.1–40°C/min |
| Cool-down Rate | 400°C to 50°C in ~6 min |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Gaseous Oxygen & Liquid Oxygen Analysis |
| Temperature Control Range | 4 °C above ambient to 450 °C |
| Oven Ramp Rate | 0.1–39 °C/min (standard) |
| Cooling Rate | ~6 min from 450 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Secondary Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Zone Temperature Range | Ambient to 400 °C |
| Valve Injection Zone Temperature Range | Ambient to 240 °C |
| Transfer Line Temperature Range | Ambient to 240 °C |
| Cold Trap Temperature Range | −30 °C |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >95% |
| Sample Capacity | 20 adsorption tubes (dual-channel configuration) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AA2600 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Flame AAS |
| Monochromator Type | Czerny-Turner with Aberration Correction |
| Optical System | Single-beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal Method |
| Spectral Resolution | 0.3 nm |
| Sensitivity (Cu) | >0.3 A at 5 ppm Cu |
| Precision (RSD) | <0.3% |
| Detection Limit (Cu) | 0.006 µg/mL |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.25 nm |
| Wavelength Repeatability | 0.15 nm |
| Baseline Drift | 0.005 A/30 min |
| Burner | 100 mm Titanium Air-Acetylene Premix Burner |
| Nebulizer | High-efficiency Glass/Plastic/Stainless Steel Options |
| Nebulization Chamber | Corrosion-Resistant Material |
| Flame Height & Position Adjustment | Motorized, One-Minute Switching Between Flame and Hydride Modes |
| Safety Features | Real-time Acetylene Leak Detection, Automatic Gas Shutoff, Overpressure Protection |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | 150 W |
| Dimensions (L×W×H) | 1000 × 350 × 390 mm |
| Weight | 70 kg |
| Operating Temperature | 10–35 °C |
| Relative Humidity | ≤80% RH |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-6210T Dedicated for Formaldehyde Dimethyl Acetal |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |