BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeDynamic Headspace Sampler
Automation LevelFully Automated
Sample Vial Heating Range20°C to 200°C
Valve & Transfer Line Temperature Control Range20°C to 240°C
Sample Loop Volume1 mL
Temperature Control Accuracy±0.1°C
Vial Capacity40 positions
Vial Format20 mL standard headspace vials
Dimensions (W×D×H)530 × 680 × 655 mm
Weight~50 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHSPX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application FieldPetrochemical Industry Dedicated
Oven Temperature RangeAmbient +5°C to 400°C
Oven Ramp Rate0.1–40°C/min
Oven Cool-down Time~6 minutes (from 450°C to 50°C)
Carrier Gas Flow Range & Control0–1000 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature400°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1000 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHSPX
OriginChina
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application FieldPharmaceutical Residue Analysis
Temperature Control RangeAmbient +5°C to 400°C
Oven Ramp Rate0.1–39.9°C/min
Cool-down Time~6 min (from 400°C to 50°C)
Carrier Gas Flow Range & Control0–1000 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature400°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1000 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelDual-Channel Low-Temperature Cryo-Trap, 40-Position
Automation LevelFully Automated
Desorption Temperature Range150–380 °C
Valve Injection Zone Temperature RangeAmbient to 240 °C
Transfer Line Temperature RangeAmbient to 240 °C
Cryo-Trap Temperature Range−30 to 50 °C (1 °C increments)
Temperature Control Accuracy±1 °C
Analyte Recovery Rate>95%
Sample Capacity40 adsorption tubes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHSPX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
ModelRefinery Gas-Specific GC
Temperature Control RangeAmbient to 400 °C
Oven Ramp Rate0.1–40 °C/min
Cool-down Time~6 min (400 °C → 50 °C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–0.6 MPa
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min
DetectorsTCD and FID
Column TypesPacked and Capillary
Multi-Valve Auto-SwitchingYes
Signal Auto-SwitchingYes
Analysis ScopeH₂, O₂, N₂, CO₂, CO, C₁–C₆₀ hydrocarbons (including C₂=–C₄= olefins and C₆⁺ saturates/olefins/aromatics)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application FieldMedical Device Sterilization Validation & Clinical Diagnostics
Temperature Control RangeAmbient +4 °C to 450 °C (1 °C increment, ±0.01 °C accuracy)
Oven Ramp Rate0.1–39 °C/min (standard), 0.1–80 °C/min (high-speed option)
Cooling Rate450 °C → 50 °C in ~6 min
Carrier Gas Flow Range & Control0–1000 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Temperature Zones8 independently controlled zones
Programmable Temperature RampingUp to 16 steps
External Event Inputs6 channels
Auxiliary Control Outputs2 channels
Injector CompatibilityPacked column, capillary column, 6-port gas valve, automated thermal desorption, purge-and-trap, and headspace sampling (HS-20A, HS-10A, or HS-12A optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application ScopeUniversal (Mine Safety & Gas Monitoring)
Oven Temperature RangeAmbient +12 °C to 400 °C
Oven Ramp Rate0.1–39 °C/min (Standard)
Oven Cooling Rate~6 min from 450 °C to 50 °C
Carrier Gas Flow Control Range0–1000 mL/min
Carrier Gas Pressure Control Range0–970 kPa
Injector Maximum Temperature400 °C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
DetectorsTCD (MDL ≤9×10⁻⁶ mg/mL in H₂, n-C₁₆), FID (MDL ≤8×10⁻¹² g/s, n-C₁₆), ECD (MDL ≤0.1 pg, γ-BHC), FPD ([P] ≤1×10⁻¹² g/s, TBP
Column ConfigurationPacked-column system with methanizer and automated 6-port valve for simultaneous O₂/N₂/CH₄/CO/CO₂ analysis
Detection RangesO₂ (20.9±5%), N₂ (78±10%), CH₄ (0.5 ppm–10%), CO (0.5 ppm–0.3%), CO₂ (1 ppm–0.5%), C₂H₆/C₂H₄/C₂H₂ (1 ppm–0.3%)
Power SupplyAC 220 V ±10%, 50 Hz
Max. Power Consumption1650 W
Net Weight~50 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeTwo-Stage Thermal Desorber
Automation LevelFully Automated
Primary Desorption Temp Range50–400 °C
Valve Injection Zone Temp RangeAmbient to 200 °C
Transfer Line Temp RangeAmbient to 200 °C
Cryo-Focusing Trap Temp Range−35 to 50 °C
Temperature Control Accuracy±0.1 °C
Desorption Recovery Efficiency≥98%
Sample Capacity50 positions
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelAA2630
Price RangeUSD 7,000–14,000
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorPlane Diffraction Grating (1800 grooves/mm)
Optical SystemDouble-Beam
DetectorHigh-Sensitivity Photomultiplier Tube (PMT)
Background CorrectionDeuterium Lamp + Self-Reversal (Auto-Adjusting)
Spectral Bandwidth0.1 / 0.2 / 0.4 / 1.0 / 2.0 nm (5-step motorized selection)
Resolution≤0.3 nm (meets Mn 279.5/279.8 nm separation criterion, valley-to-peak energy ratio <20%)
Sensitivity (Cu)>0.3 A at 5 ppm
RSD (Precision)<0.3% (Flame), ≤3% (Graphite Furnace)
Detection Limit (Cu, Flame)0.005 µg/mL
Detection Limit (Cd, GF-AAS)1.0 × 10⁻¹² g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic
ModelPT-3900A
Sample Tray Capacity84 positions
Temperature Control Accuracy±0.1°C
Trap Desorption Temperature Range100–350°C
Sample Heating Temperature (Purge Vessel)up to 250°C
Sample Vial Cooling Temperature Range0–40°C
Water Removal Trap Temp RangeAmbient–200°C
Valve & Transfer Line Temp RangeAmbient–250°C
Trap Cryo-Focusing Temp Range0–40°C
Sample Oven Temp RangeAmbient–90°C
Hot Water Bath Temp RangeAmbient–90°C
Purge Tube Temp RangeAmbient–90°C
Desorption Ramp Rate>2000°C/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic Lab-Scale Gas Chromatograph
ModelBaijiu-Specific
Temperature Control RangeAmbient to 400 °C
Oven Ramp Rate0.1–40 °C/min
Oven Cool-Down450 °C to 50 °C in ~6 min
Carrier Gas Flow Range & Control0–60 mL/min
Carrier Gas Pressure Range & Control0–0.6 MPa
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaSheng Puxin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeBenchtop Laboratory Gas Chromatograph
Application FocusPetrochemical & Liquefied Petroleum Gas (LPG) Analysis
Temperature Control RangeAmbient +5°C to 400°C
Ramp Rate0.1–40°C/min
Cool-down Time~6 min (from 450°C to 50°C)
Carrier Gas Flow Range & Control0–1000 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature400°C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1000 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application FieldBaijiu (Chinese Liquor) Analysis
Temperature Control Range20 °C to 450 °C
Temperature Ramp Rate0.1–80 °C/min
Cooling RateUp to 39.9 °C/min
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–0.6 MPa
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min
Temperature Zones8 independently controlled zones
Temperature Accuracy±0.01 °C
Minimum Temperature Increment1 °C
Programmable Temperature ProgramMulti-step (≥8 stages)
External Event Inputs6 channels
Auxiliary Outputs2 channels
Injector OptionsPacked column, capillary column, 6-port gas valve, automatic thermal desorption, purge-and-trap, and headspace sampling
Detector CapacityUp to 3 detectors simultaneously
Detector OptionsFID, TCD, ECD, FPD, NPD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application DomainClinical Toxicology & Forensic Medical Testing
Temperature Control RangeAmbient + 5°C to 400°C
Oven Ramp Rate0.1–40°C/min
Cool-down Time~6 min (from 450°C to 50°C)
Carrier Gas Flow Range & Control0–1000 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature400°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Temperature Zones8 independently controlled zones
Temperature Accuracy±0.01°C
Max Programmed Ramp Stages16
External Event Inputs6 channels
Auxiliary Outputs2 channels
Detector CapacityUp to 3 simultaneous detectors (FID, TCD, ECD, FPD, NPD configurable)
Injector OptionsPacked column, capillary column, 6-port gas valve, automated headspace, purge-and-trap, thermal desorption
SoftwareDual-language (English/Chinese) GC workstation with audit trail, method validation support, and CFR Part 11–compliant data integrity features
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHSPX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelHTB-3420
Temperature Control RangeAmbient to 400 °C
Tube Capacity1–20 tubes
Temperature Setting Increment1 °C
Temperature Accuracy±0.5% of setpoint
Temperature Uniformity±1 °C across chamber
Timer Range0–99 h 99 min, continuously adjustable
Tube CompatibilityOuter diameter 6 mm (¼ inch), unlimited length
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Product CategoryDomestic
ModelGC-BA1000
Price RangeUSD 4,200–7,000
Instrument TypeLaboratory Gas Chromatograph
Application FieldBeverage Quality Control & Regulatory Compliance
Oven Temperature RangeAmbient to 400 °C
Oven Ramp Rate0.1–40 °C/min
Oven Cooling RateFrom 450 °C to 50 °C in ~6 min
Carrier Gas Flow Range & Control0–60 mL/min
Carrier Gas Pressure Range & Control0–0.6 MPa
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin/HSPX
OriginBeijing, China
Manufacturer TypeManufacturer
Product OriginDomestic
ModelLPG-Dedicated
Instrument TypeLaboratory Gas Chromatograph
Application FieldPetrochemical Industry
Temperature Control RangeAmbient to 400 °C
Oven Ramp Rate0.1–40 °C/min
Oven Cool-down Rate450 °C to 50 °C in ~6 min
Carrier Gas Flow Range & Control0–60 mL/min
Carrier Gas Pressure Range & Control0–0.6 MPa
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaSheng PuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSingle-Stage Thermal Desorber
Desorption Temperature Range–30 °C to 400 °C
Cold Trap Temperature Range–30 °C
Desorption Recovery Rate>95%
Sample Positions20
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHSPX
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelHS-6D
PricingAvailable Upon Request
Flow ControlMass Flow Controllers (MFCs)
Display7-inch Capacitive Touchscreen
Gas Path MaterialsPassivated Stainless Steel Tubing & PTFE Tubing
Built-in PumpDiaphragm Pump for Ambient-Pressure Gas Sampling
Dilution Range1:1 to 1:100 (customizable)
Output Channels6 Independent Concentration Ports
Operation ModesSingle-point or Multi-step Sequential Dilution
Method StorageOnboard Method Library with Recall Function
Software InterfaceSingle- or Multi-channel Configuration Support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application FieldFood Industry Dedicated
Column Oven Temperature RangeAmbient + 5°C to 400°C
Ramp Rate0.1–40°C/min
Cool-down Rate400°C to 50°C in ~6 min
Carrier Gas Flow Range & Control0–1000 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Max Operating Temperature400°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1000 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
ApplicationHigh-Purity Gaseous Oxygen & Liquid Oxygen Analysis
Temperature Control Range4 °C above ambient to 450 °C
Oven Ramp Rate0.1–39 °C/min (standard)
Cooling Rate~6 min from 450 °C to 50 °C
Carrier Gas Flow Range & Control0–1000 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSecondary Thermal Desorber
Automation LevelFully Automated
Desorption Zone Temperature RangeAmbient to 400 °C
Valve Injection Zone Temperature RangeAmbient to 240 °C
Transfer Line Temperature RangeAmbient to 240 °C
Cold Trap Temperature Range−30 °C
Temperature Control Accuracy±1 °C
Analyte Recovery Rate>95%
Sample Capacity20 adsorption tubes (dual-channel configuration)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelAA2600
Price RangeUSD 7,000–14,000
Instrument TypeFlame AAS
Monochromator TypeCzerny-Turner with Aberration Correction
Optical SystemSingle-beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionDeuterium Lamp + Self-Reversal Method
Spectral Resolution0.3 nm
Sensitivity (Cu)>0.3 A at 5 ppm Cu
Precision (RSD)<0.3%
Detection Limit (Cu)0.006 µg/mL
Wavelength Range190–900 nm
Wavelength Accuracy±0.25 nm
Wavelength Repeatability0.15 nm
Baseline Drift0.005 A/30 min
Burner100 mm Titanium Air-Acetylene Premix Burner
NebulizerHigh-efficiency Glass/Plastic/Stainless Steel Options
Nebulization ChamberCorrosion-Resistant Material
Flame Height & Position AdjustmentMotorized, One-Minute Switching Between Flame and Hydride Modes
Safety FeaturesReal-time Acetylene Leak Detection, Automatic Gas Shutoff, Overpressure Protection
Power SupplyAC 220 V / 50 Hz
Power Consumption150 W
Dimensions (L×W×H)1000 × 350 × 390 mm
Weight70 kg
Operating Temperature10–35 °C
Relative Humidity≤80% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
ModelGC-6210T Dedicated for Formaldehyde Dimethyl Acetal
Temperature Control RangeAmbient to 400 °C
Oven Ramp Rate0.1–40 °C/min
Cool-down Time~6 min (400 °C → 50 °C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–0.6 MPa
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min