| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry Dedicated |
| Oven Temperature Range | Ambient +5°C to 400°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Oven Cool-down Time | ~6 minutes (from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HSPX |
|---|---|
| Origin | China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical Residue Analysis |
| Temperature Control Range | Ambient +5°C to 400°C |
| Oven Ramp Rate | 0.1–39.9°C/min |
| Cool-down Time | ~6 min (from 400°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | Refinery Gas-Specific GC |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detectors | TCD and FID |
| Column Types | Packed and Capillary |
| Multi-Valve Auto-Switching | Yes |
| Signal Auto-Switching | Yes |
| Analysis Scope | H₂, O₂, N₂, CO₂, CO, C₁–C₆₀ hydrocarbons (including C₂=–C₄= olefins and C₆⁺ saturates/olefins/aromatics) |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Medical Device Sterilization Validation & Clinical Diagnostics |
| Temperature Control Range | Ambient +4 °C to 450 °C (1 °C increment, ±0.01 °C accuracy) |
| Oven Ramp Rate | 0.1–39 °C/min (standard), 0.1–80 °C/min (high-speed option) |
| Cooling Rate | 450 °C → 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Zones | 8 independently controlled zones |
| Programmable Temperature Ramping | Up to 16 steps |
| External Event Inputs | 6 channels |
| Auxiliary Control Outputs | 2 channels |
| Injector Compatibility | Packed column, capillary column, 6-port gas valve, automated thermal desorption, purge-and-trap, and headspace sampling (HS-20A, HS-10A, or HS-12A optional) |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal (Mine Safety & Gas Monitoring) |
| Oven Temperature Range | Ambient +12 °C to 400 °C |
| Oven Ramp Rate | 0.1–39 °C/min (Standard) |
| Oven Cooling Rate | ~6 min from 450 °C to 50 °C |
| Carrier Gas Flow Control Range | 0–1000 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detectors | TCD (MDL ≤9×10⁻⁶ mg/mL in H₂, n-C₁₆), FID (MDL ≤8×10⁻¹² g/s, n-C₁₆), ECD (MDL ≤0.1 pg, γ-BHC), FPD ([P] ≤1×10⁻¹² g/s, TBP |
| Column Configuration | Packed-column system with methanizer and automated 6-port valve for simultaneous O₂/N₂/CH₄/CO/CO₂ analysis |
| Detection Ranges | O₂ (20.9±5%), N₂ (78±10%), CH₄ (0.5 ppm–10%), CO (0.5 ppm–0.3%), CO₂ (1 ppm–0.5%), C₂H₆/C₂H₄/C₂H₂ (1 ppm–0.3%) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | 1650 W |
| Net Weight | ~50 kg |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | Baijiu-Specific |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down | 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaSheng Puxin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Focus | Petrochemical & Liquefied Petroleum Gas (LPG) Analysis |
| Temperature Control Range | Ambient +5°C to 400°C |
| Ramp Rate | 0.1–40°C/min |
| Cool-down Time | ~6 min (from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Baijiu (Chinese Liquor) Analysis |
| Temperature Control Range | 20 °C to 450 °C |
| Temperature Ramp Rate | 0.1–80 °C/min |
| Cooling Rate | Up to 39.9 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Zones | 8 independently controlled zones |
| Temperature Accuracy | ±0.01 °C |
| Minimum Temperature Increment | 1 °C |
| Programmable Temperature Program | Multi-step (≥8 stages) |
| External Event Inputs | 6 channels |
| Auxiliary Outputs | 2 channels |
| Injector Options | Packed column, capillary column, 6-port gas valve, automatic thermal desorption, purge-and-trap, and headspace sampling |
| Detector Capacity | Up to 3 detectors simultaneously |
| Detector Options | FID, TCD, ECD, FPD, NPD |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Clinical Toxicology & Forensic Medical Testing |
| Temperature Control Range | Ambient + 5°C to 400°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Cool-down Time | ~6 min (from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Zones | 8 independently controlled zones |
| Temperature Accuracy | ±0.01°C |
| Max Programmed Ramp Stages | 16 |
| External Event Inputs | 6 channels |
| Auxiliary Outputs | 2 channels |
| Detector Capacity | Up to 3 simultaneous detectors (FID, TCD, ECD, FPD, NPD configurable) |
| Injector Options | Packed column, capillary column, 6-port gas valve, automated headspace, purge-and-trap, thermal desorption |
| Software | Dual-language (English/Chinese) GC workstation with audit trail, method validation support, and CFR Part 11–compliant data integrity features |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | GC-BA1000 |
| Price Range | USD 4,200–7,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Beverage Quality Control & Regulatory Compliance |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cooling Rate | From 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin/HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | LPG-Dedicated |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Rate | 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Industry Dedicated |
| Column Oven Temperature Range | Ambient + 5°C to 400°C |
| Ramp Rate | 0.1–40°C/min |
| Cool-down Rate | 400°C to 50°C in ~6 min |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Gaseous Oxygen & Liquid Oxygen Analysis |
| Temperature Control Range | 4 °C above ambient to 450 °C |
| Oven Ramp Rate | 0.1–39 °C/min (standard) |
| Cooling Rate | ~6 min from 450 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-6210T Dedicated for Formaldehyde Dimethyl Acetal |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Oven Temperature Range | Ambient +5°C to 400°C |
| Temperature Ramp Rate | 0.1–40°C/min |
| Cooling Rate | 400°C → 50°C in ~6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | Thermal Conductivity Detector (TCD) |
| TCD Sensitivity | ≥3000 mV·mL/mg (benzene) |
| TCD Baseline Drift | ≤3% of full scale per hour |
| Column | 3 mm ID × 6 m stainless steel packed column |
| Injection Mode | 6-port gas sampling valve |
| Display & Control | Microprocessor-controlled with backlit LCD and Chinese-language keypad |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China-made) |
| Model | Formaldehyde Dimethyl-Specific Gas Chromatograph |
| Price Range | USD 4,200 – 7,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Solvent Purity Analysis & Quality Control |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cooling Rate | From 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | LC3000 |
| Price Range | USD 7,000 – 14,000 (FOB China) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Pump Type | Dual-Piston Reciprocating High-Pressure Solvent Delivery System (P3000 Series) |
| Detector Type | UV/VIS Absorbance Detector (UV3000) |
| Display | 320 × 240 dot-matrix LCD with adjustable blue backlight |
| Control Modes | Standalone front-panel operation & RS232 serial interface |
| Power Supply | 220 V ±10%, 50 Hz, 400 W (pump) |
| Dimensions (D×H×W) | 398 × 149 × 267 mm |
| Weight | 14 kg |
| GLP Data Logging | Lamp operating time, lamp ignition count, lamp replacement history, and instrument serial number |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Solvent Residue Analysis in Edible Oils, Food Additives, and Pesticide Residues |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Time | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | Flame Ionization Detector (FID) |
| Column Compatibility | Capillary columns for volatile organic solvent separation (e.g., DB-VRX, HP-PONA, or equivalent polar/non-polar GC columns) |
| Data System | Integrated GC workstation with peak integration, calibration curve generation, and audit-trail-capable reporting |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ATDS-3600A |
| Temperature Control Range | Ambient to 400 °C |
| Heating Rate | 0.1–40 °C/min |
| Cooling Rate | 400 °C to 50 °C in ~5 min |
| Carrier Gas Flow Range | 0–60 mL/min |
| Carrier Gas Pressure Range | 0–0.6 MPa |
| Injector Max Temp | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Sample Positions | 20 |
| Cold Trap Temp Range | −30 °C to +50 °C |
| Temp Accuracy | <±0.1 °C |
| Temp Gradient Uniformity | <±0.1 °C |
| Transfer Line & Valve Zone Temp Control | Ambient to 220 °C |
| Desorption Ramp Rate | >2000 °C/min |
| Purge Flow | 0–400 mL/min |
| Dimensions | 450 × 360 × 510 mm |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Solvent Residue GC for Plastic Flexible Packaging |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Industry-Specific |
| Oven Temperature Range | Ambient + 5°C to 400°C |
| Ramp Rate | 0.1–40°C/min |
| Cool-down Rate | ~6 min (400°C → 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | Solvent Residue-Specific Gas Chromatograph |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Instrument Type | Laboratory-Grade Gas Chromatograph |
| Primary Application Domain | Food Packaging Safety Testing |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Time | ~6 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | Flame Ionization Detector (FID) |
| Column | Pre-configured Capillary Column for Volatile Organic Solvent Separation |
| Data System | Integrated Chromatography Workstation with Audit Trail Capability |
| Required Gases | High-Purity Nitrogen (carrier), Hydrogen (detector fuel), and Compressed Air (detector oxidant) |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GC-Universal Series |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Oven Temperature Range | Ambient + 4 °C to 450 °C (1 °C increment, ±0.01 °C accuracy) |
| Ramp Rate | 0.1–39 °C/min (Standard) |
| Cool-Down Rate | 450 °C → 50 °C in ~6 min |
| Carrier Gas Flow Control Range | 0–1000 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Oven Programmable Steps | 16-stage |
| Hold Time per Step | 0–655 min |
| TCD Sensitivity | ≥5000 mV·mL/mg |
| FID Detection Limit | ≤5×10⁻¹² g/s (n-decane) |
| ECD Detection Limit | ≤1×10⁻¹³ g/s (γ-BHC) |
| FPD Detection Limit | ≤5×10⁻¹³ g/s (S), ≤1.4×10⁻¹³ g/s (P) |
| NPD Detection Limit | ≤5×10⁻¹³ g/s (N) |
| Power Supply | 220 V ±10% AC, 50 ±0.5 Hz |
| Max Power Consumption | ≤1500 W |
| Dimensions (L×W×H) | 628 × 465 × 460 mm |
| Weight | 50 kg |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Model | GC-9100 |
| Temperature Control Range | Ambient +20 °C to 400 °C (oven, inlet, detector) |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Rate | 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Temp | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector Options | FID, TCD, ECD, FPD, NPD |
| Display | Color LCD with bilingual (English/Chinese) UI |
| Control Interface | PC-based software with remote operation capability |
| Automation Interfaces | Built-in driver support for autosamplers, thermal desorbers, purge-and-trap systems |
| Safety Features | Auto flame ignition, flame-out detection & re-ignition, gas leak protection, automatic gas-line initialization |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | GC6210 |
| Price Range | USD 4,200 – 7,000 |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Rate | 400 °C → 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detection Limits (as per GB/T 17623) | H₂ ≤ 2 ppm, CO ≤ 5 ppm, CH₄ ≤ 0.1 ppm, CO₂ ≤ 5 ppm, C₂H₂ ≤ 0.1 ppm, C₂H₆ ≤ 0.1 ppm, C₂H₄ ≤ 0.1 ppm |