Empowering Scientific Discovery

Beijing Huashengpu Xin Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHSPX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application FieldPetrochemical Industry Dedicated
Oven Temperature RangeAmbient +5°C to 400°C
Oven Ramp Rate0.1–40°C/min
Oven Cool-down Time~6 minutes (from 450°C to 50°C)
Carrier Gas Flow Range & Control0–1000 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature400°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1000 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHSPX
OriginChina
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application FieldPharmaceutical Residue Analysis
Temperature Control RangeAmbient +5°C to 400°C
Oven Ramp Rate0.1–39.9°C/min
Cool-down Time~6 min (from 400°C to 50°C)
Carrier Gas Flow Range & Control0–1000 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature400°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1000 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHSPX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
ModelRefinery Gas-Specific GC
Temperature Control RangeAmbient to 400 °C
Oven Ramp Rate0.1–40 °C/min
Cool-down Time~6 min (400 °C → 50 °C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–0.6 MPa
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min
DetectorsTCD and FID
Column TypesPacked and Capillary
Multi-Valve Auto-SwitchingYes
Signal Auto-SwitchingYes
Analysis ScopeH₂, O₂, N₂, CO₂, CO, C₁–C₆₀ hydrocarbons (including C₂=–C₄= olefins and C₆⁺ saturates/olefins/aromatics)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application FieldMedical Device Sterilization Validation & Clinical Diagnostics
Temperature Control RangeAmbient +4 °C to 450 °C (1 °C increment, ±0.01 °C accuracy)
Oven Ramp Rate0.1–39 °C/min (standard), 0.1–80 °C/min (high-speed option)
Cooling Rate450 °C → 50 °C in ~6 min
Carrier Gas Flow Range & Control0–1000 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Temperature Zones8 independently controlled zones
Programmable Temperature RampingUp to 16 steps
External Event Inputs6 channels
Auxiliary Control Outputs2 channels
Injector CompatibilityPacked column, capillary column, 6-port gas valve, automated thermal desorption, purge-and-trap, and headspace sampling (HS-20A, HS-10A, or HS-12A optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application ScopeUniversal (Mine Safety & Gas Monitoring)
Oven Temperature RangeAmbient +12 °C to 400 °C
Oven Ramp Rate0.1–39 °C/min (Standard)
Oven Cooling Rate~6 min from 450 °C to 50 °C
Carrier Gas Flow Control Range0–1000 mL/min
Carrier Gas Pressure Control Range0–970 kPa
Injector Maximum Temperature400 °C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
DetectorsTCD (MDL ≤9×10⁻⁶ mg/mL in H₂, n-C₁₆), FID (MDL ≤8×10⁻¹² g/s, n-C₁₆), ECD (MDL ≤0.1 pg, γ-BHC), FPD ([P] ≤1×10⁻¹² g/s, TBP
Column ConfigurationPacked-column system with methanizer and automated 6-port valve for simultaneous O₂/N₂/CH₄/CO/CO₂ analysis
Detection RangesO₂ (20.9±5%), N₂ (78±10%), CH₄ (0.5 ppm–10%), CO (0.5 ppm–0.3%), CO₂ (1 ppm–0.5%), C₂H₆/C₂H₄/C₂H₂ (1 ppm–0.3%)
Power SupplyAC 220 V ±10%, 50 Hz
Max. Power Consumption1650 W
Net Weight~50 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic Lab-Scale Gas Chromatograph
ModelBaijiu-Specific
Temperature Control RangeAmbient to 400 °C
Oven Ramp Rate0.1–40 °C/min
Oven Cool-Down450 °C to 50 °C in ~6 min
Carrier Gas Flow Range & Control0–60 mL/min
Carrier Gas Pressure Range & Control0–0.6 MPa
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaSheng Puxin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeBenchtop Laboratory Gas Chromatograph
Application FocusPetrochemical & Liquefied Petroleum Gas (LPG) Analysis
Temperature Control RangeAmbient +5°C to 400°C
Ramp Rate0.1–40°C/min
Cool-down Time~6 min (from 450°C to 50°C)
Carrier Gas Flow Range & Control0–1000 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature400°C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1000 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application FieldBaijiu (Chinese Liquor) Analysis
Temperature Control Range20 °C to 450 °C
Temperature Ramp Rate0.1–80 °C/min
Cooling RateUp to 39.9 °C/min
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–0.6 MPa
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min
Temperature Zones8 independently controlled zones
Temperature Accuracy±0.01 °C
Minimum Temperature Increment1 °C
Programmable Temperature ProgramMulti-step (≥8 stages)
External Event Inputs6 channels
Auxiliary Outputs2 channels
Injector OptionsPacked column, capillary column, 6-port gas valve, automatic thermal desorption, purge-and-trap, and headspace sampling
Detector CapacityUp to 3 detectors simultaneously
Detector OptionsFID, TCD, ECD, FPD, NPD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application DomainClinical Toxicology & Forensic Medical Testing
Temperature Control RangeAmbient + 5°C to 400°C
Oven Ramp Rate0.1–40°C/min
Cool-down Time~6 min (from 450°C to 50°C)
Carrier Gas Flow Range & Control0–1000 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature400°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Temperature Zones8 independently controlled zones
Temperature Accuracy±0.01°C
Max Programmed Ramp Stages16
External Event Inputs6 channels
Auxiliary Outputs2 channels
Detector CapacityUp to 3 simultaneous detectors (FID, TCD, ECD, FPD, NPD configurable)
Injector OptionsPacked column, capillary column, 6-port gas valve, automated headspace, purge-and-trap, thermal desorption
SoftwareDual-language (English/Chinese) GC workstation with audit trail, method validation support, and CFR Part 11–compliant data integrity features
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Product CategoryDomestic
ModelGC-BA1000
Price RangeUSD 4,200–7,000
Instrument TypeLaboratory Gas Chromatograph
Application FieldBeverage Quality Control & Regulatory Compliance
Oven Temperature RangeAmbient to 400 °C
Oven Ramp Rate0.1–40 °C/min
Oven Cooling RateFrom 450 °C to 50 °C in ~6 min
Carrier Gas Flow Range & Control0–60 mL/min
Carrier Gas Pressure Range & Control0–0.6 MPa
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin/HSPX
OriginBeijing, China
Manufacturer TypeManufacturer
Product OriginDomestic
ModelLPG-Dedicated
Instrument TypeLaboratory Gas Chromatograph
Application FieldPetrochemical Industry
Temperature Control RangeAmbient to 400 °C
Oven Ramp Rate0.1–40 °C/min
Oven Cool-down Rate450 °C to 50 °C in ~6 min
Carrier Gas Flow Range & Control0–60 mL/min
Carrier Gas Pressure Range & Control0–0.6 MPa
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application FieldFood Industry Dedicated
Column Oven Temperature RangeAmbient + 5°C to 400°C
Ramp Rate0.1–40°C/min
Cool-down Rate400°C to 50°C in ~6 min
Carrier Gas Flow Range & Control0–1000 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Max Operating Temperature400°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1000 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
ApplicationHigh-Purity Gaseous Oxygen & Liquid Oxygen Analysis
Temperature Control Range4 °C above ambient to 450 °C
Oven Ramp Rate0.1–39 °C/min (standard)
Cooling Rate~6 min from 450 °C to 50 °C
Carrier Gas Flow Range & Control0–1000 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
ModelGC-6210T Dedicated for Formaldehyde Dimethyl Acetal
Temperature Control RangeAmbient to 400 °C
Oven Ramp Rate0.1–40 °C/min
Cool-down Time~6 min (400 °C → 50 °C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–0.6 MPa
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application FieldPetrochemical Industry
Oven Temperature RangeAmbient +5°C to 400°C
Temperature Ramp Rate0.1–40°C/min
Cooling Rate400°C → 50°C in ~6 min
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–0.6 MPa
Injector Maximum Operating Temperature400°C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min
DetectorThermal Conductivity Detector (TCD)
TCD Sensitivity≥3000 mV·mL/mg (benzene)
TCD Baseline Drift≤3% of full scale per hour
Column3 mm ID × 6 m stainless steel packed column
Injection Mode6-port gas sampling valve
Display & ControlMicroprocessor-controlled with backlit LCD and Chinese-language keypad
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China-made)
ModelFormaldehyde Dimethyl-Specific Gas Chromatograph
Price RangeUSD 4,200 – 7,000
Instrument TypeLaboratory Gas Chromatograph
Application FieldSolvent Purity Analysis & Quality Control
Oven Temperature RangeAmbient to 400 °C
Oven Ramp Rate0.1–40 °C/min
Oven Cooling RateFrom 450 °C to 50 °C in ~6 min
Carrier Gas Flow Range & Control0–60 mL/min
Carrier Gas Pressure Range & Control0–0.6 MPa
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument CategoryDomestic
ModelLC3000
Price RangeUSD 7,000 – 14,000 (FOB China)
Instrument TypeConventional High-Performance Liquid Chromatograph (HPLC)
Pump TypeDual-Piston Reciprocating High-Pressure Solvent Delivery System (P3000 Series)
Detector TypeUV/VIS Absorbance Detector (UV3000)
Display320 × 240 dot-matrix LCD with adjustable blue backlight
Control ModesStandalone front-panel operation & RS232 serial interface
Power Supply220 V ±10%, 50 Hz, 400 W (pump)
Dimensions (D×H×W)398 × 149 × 267 mm
Weight14 kg
GLP Data LoggingLamp operating time, lamp ignition count, lamp replacement history, and instrument serial number
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHSPX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application ScopeSolvent Residue Analysis in Edible Oils, Food Additives, and Pesticide Residues
Oven Temperature RangeAmbient to 400 °C
Oven Ramp Rate0.1–40 °C/min
Oven Cool-down Time~6 min (400 °C → 50 °C)
Carrier Gas Flow Control Range0–1200 mL/min
Carrier Gas Pressure Control Range0–0.6 MPa
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min
DetectorFlame Ionization Detector (FID)
Column CompatibilityCapillary columns for volatile organic solvent separation (e.g., DB-VRX, HP-PONA, or equivalent polar/non-polar GC columns)
Data SystemIntegrated GC workstation with peak integration, calibration curve generation, and audit-trail-capable reporting
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelATDS-3600A
Temperature Control RangeAmbient to 400 °C
Heating Rate0.1–40 °C/min
Cooling Rate400 °C to 50 °C in ~5 min
Carrier Gas Flow Range0–60 mL/min
Carrier Gas Pressure Range0–0.6 MPa
Injector Max Temp400 °C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min
Sample Positions20
Cold Trap Temp Range−30 °C to +50 °C
Temp Accuracy<±0.1 °C
Temp Gradient Uniformity<±0.1 °C
Transfer Line & Valve Zone Temp ControlAmbient to 220 °C
Desorption Ramp Rate>2000 °C/min
Purge Flow0–400 mL/min
Dimensions450 × 360 × 510 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHSPX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelSolvent Residue GC for Plastic Flexible Packaging
Instrument TypeLaboratory Gas Chromatograph
Application FieldFood Industry-Specific
Oven Temperature RangeAmbient + 5°C to 400°C
Ramp Rate0.1–40°C/min
Cool-down Rate~6 min (400°C → 50°C)
Carrier Gas Flow Range & Control0–1000 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Max Operating Temperature400°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1000 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHSPX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic Instrument
ModelSolvent Residue-Specific Gas Chromatograph
Price RangeUSD 7,000 – 14,000 (FOB)
Instrument TypeLaboratory-Grade Gas Chromatograph
Primary Application DomainFood Packaging Safety Testing
Oven Temperature RangeAmbient to 400 °C
Oven Ramp Rate0.1–40 °C/min
Oven Cool-Down Time~6 min (from 400 °C to 50 °C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–0.6 MPa
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min
DetectorFlame Ionization Detector (FID)
ColumnPre-configured Capillary Column for Volatile Organic Solvent Separation
Data SystemIntegrated Chromatography Workstation with Audit Trail Capability
Required GasesHigh-Purity Nitrogen (carrier), Hydrogen (detector fuel), and Compressed Air (detector oxidant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHSPX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelGC-Universal Series
Instrument TypeBenchtop Laboratory Gas Chromatograph
Application ScopeGeneral-Purpose Analysis
Oven Temperature RangeAmbient + 4 °C to 450 °C (1 °C increment, ±0.01 °C accuracy)
Ramp Rate0.1–39 °C/min (Standard)
Cool-Down Rate450 °C → 50 °C in ~6 min
Carrier Gas Flow Control Range0–1000 mL/min
Carrier Gas Pressure Control Range0–970 kPa
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Column Oven Programmable Steps16-stage
Hold Time per Step0–655 min
TCD Sensitivity≥5000 mV·mL/mg
FID Detection Limit≤5×10⁻¹² g/s (n-decane)
ECD Detection Limit≤1×10⁻¹³ g/s (γ-BHC)
FPD Detection Limit≤5×10⁻¹³ g/s (S), ≤1.4×10⁻¹³ g/s (P)
NPD Detection Limit≤5×10⁻¹³ g/s (N)
Power Supply220 V ±10% AC, 50 ±0.5 Hz
Max Power Consumption≤1500 W
Dimensions (L×W×H)628 × 465 × 460 mm
Weight50 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHSPX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeBenchtop Laboratory Gas Chromatograph
ModelGC-9100
Temperature Control RangeAmbient +20 °C to 400 °C (oven, inlet, detector)
Ramp Rate0.1–40 °C/min
Cool-down Rate450 °C to 50 °C in ~6 min
Carrier Gas Flow Range & Control0–60 mL/min
Carrier Gas Pressure Range & Control0–0.6 MPa
Injector Max Temp400 °C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min
Detector OptionsFID, TCD, ECD, FPD, NPD
DisplayColor LCD with bilingual (English/Chinese) UI
Control InterfacePC-based software with remote operation capability
Automation InterfacesBuilt-in driver support for autosamplers, thermal desorbers, purge-and-trap systems
Safety FeaturesAuto flame ignition, flame-out detection & re-ignition, gas leak protection, automatic gas-line initialization
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuaShengPuXin (HSPX)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic Lab-Scale Gas Chromatograph
ModelGC6210
Price RangeUSD 4,200 – 7,000
Oven Temperature RangeAmbient to 400 °C
Oven Ramp Rate0.1–40 °C/min
Oven Cool-Down Rate400 °C → 50 °C in ~6 min
Carrier Gas Flow Range & Control0–60 mL/min
Carrier Gas Pressure Range & Control0–0.6 MPa
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range0–0.6 MPa
Injector Total Flow Setting Range0–1200 mL/min
Detection Limits (as per GB/T 17623)H₂ ≤ 2 ppm, CO ≤ 5 ppm, CH₄ ≤ 0.1 ppm, CO₂ ≤ 5 ppm, C₂H₂ ≤ 0.1 ppm, C₂H₆ ≤ 0.1 ppm, C₂H₄ ≤ 0.1 ppm
Show next