- All
- Favorite
- Popular
- Most rated
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY-CX3B |
| Instrument Type | Isoelectric Focusing (IEF) Electrophoresis Apparatus |
| Main Component | Electrophoresis Tank |
| Gel Dimensions (W×L) | 330 × 320 mm |
| Gel Thickness | 0.4 mm |
| Max Sample Capacity | 100 wells (with optional combs) |
| Buffer Volume (Shark-Tooth Chamber) | ~750 mL |
| External Dimensions (L×W×H) | 460 × 230 × 400 mm |
| Net Weight | 13.2 kg |
| Cooling Mechanism | Conduction-cooled via Anodized Aluminum Heat-Spreading Plate |
| Electrode Accessibility | Removable Electrode Assembly |
| Safety Features | Lid-actuated Power Cut-off, Ergonomic Release Button |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JY-SC10 |
| Instrument Type | Comet Assay Electrophoresis Chamber |
| Slide Capacity | 10 microscope slides |
| Buffer Volume | 400 mL |
| Dimensions (L×W×H) | 365 × 165 × 55 mm |
| Net Weight | 1.2 kg |
| Safety Feature | Lid-activated power cutoff |
| Optional Accessory | External recirculating chiller for temperature control |
| Electrode Assembly | Removable and serviceable electrode holder |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JY-ZY7 |
| Instrument Type | Semi-Dry Electrophoretic Transfer Apparatus |
| Main Unit | Transfer Tank |
| Gel Format | 216 × 110 mm |
| Buffer Capacity | ~1800 mL |
| Dimensions (L×W×H) | 290 × 170 × 155 mm |
| Net Weight | 1.7 kg |
| Housing Material | Optical-grade Polycarbonate |
| Electrode Configuration | Removable Parallel-Plate Electrodes |
| Safety Feature | Lid-Interlocked Power Cut-off |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JY-SPAT |
| Instrument Type | Transfer Electrophoresis Apparatus |
| Primary Component | Electrophoresis Chamber |
| Gel Dimensions (W×L) | 48×75 mm |
| Sample Capacity | 18 wells |
| Buffer Volume | ~150 mL |
| External Dimensions (L×W×H) | 250×90×50 mm |
| Net Weight | 0.4 kg |
| Gel Thickness Options | 1.0 mm and 1.5 mm |
| Comb Configurations | 3-, 5-, and 9-well combs for both thicknesses |
| Material | Imported high-transparency polycarbonate (PC), one-piece injection molded |
| Safety Features | Lid-integrated automatic circuit cutoff, ergonomic handle-equipped gel tray, color-contrasted loading background, removable electrode assembly, dedicated gel casting comb set |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY-SCZF |
| Instrument Type | Isoelectric Focusing (IEF) Electrophoresis System |
| Main Unit | Vertical Electrophoresis Tank |
| Gel Dimensions (W×L) | 306 × 95 mm |
| Sample Capacity | 204 samples (with 102-well comb × 2 gels) |
| Gel Thickness Options | 1.0 mm or 1.5 mm (optional) |
| Gel Quantity | 1–2 gels per run |
| Buffer Volume | ~3500 mL |
| External Dimensions (L×W×H) | 400 × 130 × 135 mm |
| Net Weight | 5.6 kg |
| Glass Plate Area (W×L) | 338 × 110 mm |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory workflows |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY-CX2B |
| Instrument Type | Horizontal Electrophoresis Tank |
| Gel Dimensions (W×L) | 330 × 420 mm |
| Gel Thickness | 0.4 mm |
| Max. Sample Capacity | 100 wells (with 0.4 mm gel thickness) |
| Buffer Volume | ~750 mL |
| External Dimensions (L×W×H) | 455 × 230 × 500 mm |
| Net Weight | 16.5 kg |
| Electrode Assembly | Removable stainless-steel electrode frame with shark-tooth comb |
| Cooling Mechanism | Passive conduction via anodized aluminum heat-dissipating plate |
| Safety Features | Lid-actuated power cutoff, ergonomic release button, drip-free buffer drainage system |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY200E |
| Output Modes | Constant Voltage / Constant Current / Constant Power |
| Voltage Range | 5–200 V (1 V resolution) |
| Current Range | 1–2000 mA (1 mA resolution) |
| Power Range | 1–200 W (1 W resolution) |
| Timing Range | 1 min – 99 h 59 min |
| Volt-Hour Range | 1–99999 V·h (1 V·h increment) |
| Display | Backlit LCD |
| Output Ports | 4 independent pairs |
| Dimensions (L×W×H) | 280 × 237 × 118 mm |
| Net Weight | 3.2 kg |
| Protection Features | Overload, Open-Circuit, Leakage Detection |
| Memory Capacity | 100 pre-programmed methods |
| Control Architecture | Dual-core microprocessor with touch-sensitive keypad |
| Operational Modes | Standard, Timed, Volt-Hour, Stepwise (up to 10 sequential programs, each with up to 10 steps) |
| Pause & Real-time Adjustment | Supported with maintained output stability |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY300C |
| Output Modes | Constant Voltage / Constant Current / Constant Power |
| Voltage Range | 3–300 V (1 V resolution) |
| Current Range | 1–400 mA (1 mA resolution) |
| Power Range | 1–120 W (1 W resolution) |
| Timing Range | 1 min – 99 h 59 min |
| Display | Backlit LCD (128×64 pixels) |
| Output Ports | 4 independent pairs |
| Dimensions (L×W×H) | 280×237×118 mm |
| Net Weight | 3.2 kg |
| Safety Protections | Overload, open-circuit, leakage current, thermal shutdown |
| Memory Capacity | 10 pre-programmed methods |
| Compliance | CE-marked design principles |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JY-TD331A |
| Instrument Category | Electrophoresis Tank |
| Primary Configuration | Integrated Electrophoresis Unit (Power Supply + DGGE Tank) |
| Gel Dimensions (W×L) | 162 × 175 mm |
| Gel Thickness | 1.0 mm |
| Number of Gels Supported | 1–2 |
| Sample Capacity | 70 wells (1.0 mm thickness) |
| Max Output | 600 V / 500 mA / 300 W |
| Operating Voltage Range | 30–300 V (programmable) |
| Buffer Volume | ~10 L |
| Temperature Uniformity | ±0.5 °C (with integrated recirculation pump) |
| External Dimensions (L×W×H) | 458 × 230 × 285 mm |
| Net Weight | 23 kg |
| Timer Range | 1 min – 100 h |
| Stored Programs | 10 |
| Safety Features | Lid-open automatic power cutoff, buffer level sensor, over-voltage/over-current protection, insulated flame-retardant housing |
| Control Interface | Microprocessor-based digital display with real-time parameter monitoring and status feedback |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY-ECPT3000 |
| Output Modes | Constant Voltage / Constant Current / Constant Power |
| Voltage Range | 20–3000 V |
| Current Range | 1–200 mA |
| Power Range | 1–200 W |
| Voltage Resolution | 1 V |
| Current Resolution | 1 mA |
| Power Resolution | 1 W |
| Timer Range | 1 min – 99 h 59 min |
| Display | Backlit LCD (128 × 64 pixels) |
| Output Ports | 4 independent pairs |
| Dimensions (L×W×H) | 300 × 265 × 125 mm |
| Net Weight | 7.0 kg |
| Temperature Control Range (optional) | RT+10°C to 65°C |
| Protection Features | Overload, Open-Circuit, Leakage Detection |
| Memory Capacity | 10 pre-programmed methods |
| Additional Functions | Auto-restart after power failure, Stepwise run mode, Volt-hour tracking, Field uniformity optimization |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JY-SP7A |
| Instrument Type | Transfer Electrophoresis Apparatus |
| Primary Component | Electrophoresis Tank |
| Gel Dimensions | 70 × 250 mm × 2 (dual bridge configuration) |
| Sample Capacity | 28 samples |
| Buffer Volume | ~1000 mL |
| External Dimensions | 350 × 260 × 65 mm |
| Net Weight | 1.6 kg |
| Cooling System | Integrated passive/convective thermal management |
| Electrode Assembly | Removable and serviceable |
| Safety Interlock | Lid-activated power cutoff |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JY-SPBT |
| Instrument Type | Nucleic Acid Electrophoresis System |
| Primary Component | Horizontal Electrophoresis Tank |
| Gel Dimensions (W×L) | 78 × 100 mm |
| Sample Capacity | 30 wells (10- or 15-well combs, available in 1.0 mm and 2.0 mm thicknesses) |
| Buffer Volume | ~400 mL |
| External Dimensions (L×W×H) | 365 × 105 × 55 mm |
| Net Weight | 0.6 kg |
| Safety Features | Lid-integrated safety interlock, ergonomic tray handle, color-coded loading background, removable electrode assembly, dedicated gel casting comb set |
| Material | High-transparency imported polycarbonate (PC), one-piece injection-molded construction |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY-ZY2 |
| Instrument Type | Semi-Dry Electrophoretic Transfer Apparatus |
| Main Component | Transfer Tank |
| Gel Dimensions (W × L) | 175 mm × 175 mm |
| Buffer Volume Capacity | 4000 mL |
| External Dimensions (L × W × H) | 205 mm × 170 mm × 240 mm |
| Net Weight | 2.3 kg |
| Cooling System | Integrated passive/convective cooling module |
| Safety Features | Lid-actuated power cutoff, ergonomic safety release button, insulated safety leads |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY600 |
| Instrument Type | Protein Electrophoresis Power Supply |
| Output Modes | Constant Voltage or Constant Current |
| Voltage Range | 5–600 V (1 V resolution) |
| Current Range | 1–200 mA (1 mA resolution) |
| Maximum Power | 120 W |
| Timer Range | 1 min – 9 h 59 min |
| Display | Dual LED digital display |
| Output Ports | 2 pairs |
| Dimensions (L×W×H) | 280 × 237 × 118 mm |
| Net Weight | 3.0 kg |
| Safety Protections | Overload, open-circuit (no-load), and leakage current protection |
| Control Logic | Microprocessor-based intelligent control with auto-memory and auto-shutdown functions |
| Operating Modes | Voltage- or current-prioritized output with real-time mode indication |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY1000E |
| Instrument Type | Nucleic Acid Electrophoresis Power Supply |
| Output Modes | Constant Voltage / Constant Current / Constant Power (continuously adjustable) |
| Voltage Range | 30–1000 V |
| Current Range | 1–500 mA |
| Power Range | 1–300 W |
| Resolution | 1 V / 1 mA / 1 W |
| Timer Range | 1 min – 99 h 59 min |
| Volt-Hour Range | 1–99999 V·h (increment: 1 V·h) |
| Display | Backlit LCD |
| Output Terminals | 4 independent pairs |
| Dimensions (L×W×H) | 263 × 275 × 125 mm |
| Net Weight | 4.6 kg |
| Safety Protections | Overload, No-Load, Leakage Current, Short-Circuit |
| Memory Capacity | 100 pre-programmed methods |
| Stepwise Programming | Up to 10 sequential steps, each with independent voltage/current/power/timer settings |
| Pause & Real-Time Adjustment | Supported without compromising output stability or control accuracy |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY600C |
| Instrument Type | Protein Electrophoresis Power Supply |
| Output Modes | Constant Voltage / Constant Current / Constant Power (continuously adjustable) |
| Voltage Range | 10–600 V |
| Current Range | 1–500 mA |
| Power Range | 1–300 W |
| Resolution | 1 V / 1 mA / 1 W |
| Timer Range | 1 min – 99 h 59 min |
| Display | Backlit LCD (128 × 64 pixels) |
| Output Ports | 4 pairs |
| Dimensions (L×W×H) | 280 × 237 × 118 mm |
| Net Weight | 3.2 kg |
| Safety Protections | Overload, No-load, Leakage current |
| Memory | Stores up to 10 user-defined electrophoresis protocols |
| Additional Features | Auto-memory, auto-shutdown, timed run mode, intelligent mode prompts, optional power-resume and anti-diffusion field function |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY-SCZ8 |
| Instrument Type | Protein Electrophoresis Apparatus |
| Main Unit | Vertical Electrophoresis Tank |
| Gel Dimensions (W×L) | 174 × 195 mm |
| Gel Thickness Options | 1.0 mm and 1.5 mm |
| Number of Gels Supported | 1–2 |
| Sample Capacity | 21- or 35-well comb configurations per gel (at both thicknesses) |
| Buffer Volume | ~2200 mL |
| External Dimensions (L×W×H) | 320 × 140 × 260 mm |
| Net Weight | 13.4 kg |
| Thermal Management | Compatible with external recirculating chillers |
| Safety | Lid-actuated power cutoff, ergonomic release button |
| Gel Casting | Integrated in-situ casting system with dedicated gel casting stand |
| Electrode Assembly | Removable electrode holder |
| Edge Field Suppression | Optimized electrode geometry to eliminate fringe field distortion |
| Buffer Efficiency | >50% reduction in buffer consumption vs. conventional vertical tanks |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY600HE |
| Output Modes | Constant Voltage / Constant Current / Constant Power |
| Voltage Range | 5–600 V (1 V resolution) |
| Current Range | 1–1000 mA (1 mA resolution) |
| Power Range | 1–300 W (1 W resolution) |
| Timing Range | 1 min – 99 h 59 min |
| Volt-Hour Range | 1–99999 V·h (1 V·h increment) |
| Display | Backlit LCD |
| Output Ports | 4 independent pairs |
| Dimensions (L×W×H) | 263 × 275 × 125 mm |
| Net Weight | 4.4 kg |
| Protection Features | Overload, Open-Circuit, Leakage Detection |
| Memory Capacity | 100 user-defined protocols |
| Stepwise Programming | Up to 10 sequential programs, each with up to 10 steps |
| Pause & Real-Time Adjustment | Supported without compromising output stability |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY-Mini-P4 |
| Instrument Type | Vertical Protein Electrophoresis Apparatus |
| Gel Dimensions (W×L) | 81 × 73 mm |
| Gel Thickness Options | 0.75 mm, 1.0 mm, 1.5 mm |
| Number of Gels Supported | 1–4 |
| Sample Capacity | Up to 60 wells (11- and 15-well combs) |
| Buffer Volume | ~1200 mL |
| External Dimensions (L×W×H) | 175 × 172 × 100 mm |
| Net Weight | 2.5 kg |
| Plate Material | High-transparency polycarbonate |
| Compatibility | Compatible with Bio-Rad standard glass plates and precast gels |
| Safety Feature | Automatic power cutoff upon lid opening |
| Gel Casting Aid | Integrated in-situ gel caster (no sealing strips required) |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY-ZY3 |
| Instrument Type | Semi-Dry Electrophoretic Transfer Apparatus |
| Main Component | Transfer Tank |
| Gel Format | 140 × 140 mm |
| External Dimensions (L×W×H) | 185 × 175 × 40 mm |
| Net Weight | 1.4 kg |
| Safety Feature | Automatic Power Cut-off Upon Lid Opening |
| Buffer Volume Requirement | Minimal (Semi-Dry Configuration) |
| Transfer Time | ≤60 min |
| Cooling | Passive (No External Cooling Required) |
| Compatibility | Standard Electrophoresis Power Supplies (No High-Current Source Needed) |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JY-SPHT |
| Instrument Type | Transfer Electrophoresis System |
| Primary Component | Horizontal Electrophoresis Tank |
| Gel Dimensions (W×L) | 245 × 250 mm |
| Sample Capacity | 364 wells (configurable via comb options) |
| Buffer Volume | ~2000 mL |
| External Dimensions (L×W×H) | 487 × 300 × 93 mm |
| Net Weight | 3.8 kg |
| Gel Thickness Compatibility | 1.0 mm and 1.8 mm |
| Comb Configurations | 19-, 26-, 44-, and 52-well formats per gel |
| Safety Feature | Lid-interrupt safety circuit |
| Construction Material | Imported high-transparency polycarbonate (PC), one-piece injection molded |
| Base Tray | Ergonomic integrated handle |
| Electrode Assembly | Removable stainless-steel electrode frame with quick-release mechanism |
| Leveling | Adjustable leveling feet |
| Gel Casting | Pre-assembled, pre-aligned gel caster (no pre-treatment required) |
| Loading Compatibility | Compatible with 8-channel pipette for high-throughput sample loading |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JY-SPCT |
| Instrument Type | Nucleic Acid Electrophoresis System |
| Primary Component | Horizontal Electrophoresis Chamber |
| Gel Dimensions (W×L) | 120×120 mm, 120×60 mm, 60×120 mm, 60×60 mm |
| Sample Capacity | Up to 100 wells (configurable via comb options) |
| Buffer Volume | ~550 mL |
| External Dimensions (L×W×H) | 300×160×75 mm |
| Net Weight | 1.1 kg |
| Comb Options | 1–3 wells (1.5 mm thickness) |
| Safety Feature | Automatic power cutoff upon lid opening |
| Construction Material | Imported high-transparency polycarbonate (PC), one-piece injection molded |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY1600E |
| Output Type | Constant Voltage / Constant Current / Constant Power (continuously adjustable) |
| Output Range | 10–1600 V, 1–200 mA, 1–320 W |
| Resolution | 1 V / 1 mA / 1 W |
| Timer Range | 1 min – 99 h 59 min |
| Volt-Hour Range | 1–99999 V·h (increment: 1 V·h) |
| Display | Backlit LCD |
| Output Ports | 4 pairs |
| Dimensions (L×W×H) | 263 × 275 × 125 mm |
| Net Weight | 4.4 kg |
| Safety Protections | Overload, Open-Circuit, Leakage Current, Thermal Shutdown |
| Control Architecture | Dual-core microprocessor with touch-sensitive keypad |
| Method Storage | 100 user-programmable electrophoresis protocols |
| Operational Modes | Standard, Timed, Volt-Hour, Stepwise (up to 10 sequential programs, each supporting up to 10 steps) |
| Pause & Real-Time Adjustment | Supported with full output stability retention |
| Auto Memory & Auto Shut-off | Enabled |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY-SCZ9 |
| Instrument Type | Isoelectric Focusing (IEF) Electrophoresis System |
| Gel Dimensions (W×L) | 121 × 150 mm |
| Gel Thickness Options | 1.0 mm and 1.5 mm |
| Gel Capacity | 1–2 gels |
| Sample Capacity | 52 wells (16- or 23-well combs per gel, compatible with both thicknesses) |
| Buffer Volume | ~1200 mL |
| External Dimensions (L×W×H) | 296 × 130 × 200 mm |
| Net Weight | 6.6 kg |
| Heat Dissipation | Anodized aluminum plate with thermal uniformity design |
| Safety | Lid-interrupt interlock circuit (automatically cuts power upon lid opening) |
| Gel Casting | Integrated in-situ casting system with dedicated gel caster stand |
| Electrode Assembly | Removable and serviceable electrode holder |
| Buffer Efficiency | >50% reduction vs. conventional vertical tanks |
Show next