| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | InnovOx Laboratory |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | Supercritical Water Oxidation (SCWO) |
| Measurement Range | 0.05–50,000 ppm TOC |
| Accuracy | ±3% |
| Resolution | 0.01 ppm |
| Detection Limit | 0.05 ppm |
| Repeatability | ±3% |
| Regulatory Compliance | US EPA Methods 415.1, 415.3, 9060A |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Import Status | Imported |
| Model | CheckPoint |
| Instrument Type | Online TOC Analyzer |
| Measurement Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photolysis |
| Measurement Range | 0.21–1000 ppb C |
| Accuracy | ±5% |
| Resolution | 0.01 ppb C |
| Detection Limit | 0.21 ppb C |
| Repeatability | RSD < 1% |
| Analysis Time (Online Mode) | 15 s – 8 h (configurable) |
| Analysis Time (Grab Sample Mode) | 10 min |
| Calibration Interval | 6 months |
| Data Storage Capacity | 28,800 records |
| Connectivity | Ethernet, Modbus RTU/TCP |
| Compliance Support | IQ/OQ/PQ protocols available |
| Regulatory Context | Designed for compliance with USP <643>, EP 2.2.44, ASTM D5905, and FDA 21 CFR Part 11-ready data integrity architecture |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | M9 Laboratory |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.03 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 0.03 ppb |
| Repeatability | ≤1% RSD |
| Analysis Time | 2 minutes |
| Calibration Interval | 12 months |
| Communication Interfaces | USB, 4–20 mA, Modbus TCP/IP |
| Enclosure Rating | Dust- and Splash-Resistant (for online/portable variants) |
| Design | Modular, Touchscreen Dashboard, Reagent-Free Operation (no external gases or hazardous chemicals required) |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | M5310C |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 4 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 4 ppb |
| Repeatability | ≤1% RSD |
| Analysis Time | 2 minutes |
| Calibration Interval | 12 months |
| Regulatory Compliance | US EPA Method 415.3 & Standard Methods 5310 C |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | M5310C Online |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate |
| Measurement Range | 4 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 4 ppb |
| Repeatability | ≤1% RSD |
| Analysis Time | 2 minutes |
| Calibration Interval | 12 months |
| Compliance | US EPA Method 415.3 & Standard Methods 5310 C |
| Instrument Type | Online TOC Analyzer |