BrandSievers (Veolia)
OriginUSA
ModelInnovOx Laboratory
Instrument TypeLaboratory TOC Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Oxidation MethodSupercritical Water Oxidation (SCWO)
Measurement Range0.05–50,000 ppm TOC
Accuracy±3%
Resolution0.01 ppm
Detection Limit0.05 ppm
Repeatability±3%
Regulatory ComplianceUS EPA Methods 415.1, 415.3, 9060A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPMS
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelLasair Pro
Instrument TypeHandheld
Flow RateHigh-Flow
Flow Rate Accuracy±5%
Timing Accuracy±0.01 s
Repeatability±0.01% RSD
Size Distribution Accuracy±0.01 µm (at calibration points)
Indication Accuracy±0.001 particles/ft³ (traceable to NIST standards)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSievers (Veolia)
OriginUSA
Manufacturer StatusAuthorized Distributor
Import StatusImported
ModelCheckPoint
Instrument TypeOnline TOC Analyzer
Measurement PrincipleDirect Conductivity Detection
Oxidation MethodUV Photolysis
Measurement Range0.21–1000 ppb C
Accuracy±5%
Resolution0.01 ppb C
Detection Limit0.21 ppb C
RepeatabilityRSD < 1%
Analysis Time (Online Mode)15 s – 8 h (configurable)
Analysis Time (Grab Sample Mode)10 min
Calibration Interval6 months
Data Storage Capacity28,800 records
ConnectivityEthernet, Modbus RTU/TCP
Compliance SupportIQ/OQ/PQ protocols available
Regulatory ContextDesigned for compliance with USP <643>, EP 2.2.44, ASTM D5905, and FDA 21 CFR Part 11-ready data integrity architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSievers (Veolia)
OriginUSA
ModelM9 Laboratory
Detection PrincipleMembrane Conductivity Detection
Oxidation MethodUV/Persulfate Oxidation
Measurement Range0.03 ppb – 50 ppm
Accuracy±2% or ±0.5 ppb (whichever is greater)
Resolution0.01 ppb
Detection Limit0.03 ppb
Repeatability≤1% RSD
Analysis Time2 minutes
Calibration Interval12 months
Communication InterfacesUSB, 4–20 mA, Modbus TCP/IP
Enclosure RatingDust- and Splash-Resistant (for online/portable variants)
DesignModular, Touchscreen Dashboard, Reagent-Free Operation (no external gases or hazardous chemicals required)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSievers (Veolia)
OriginUSA
ModelM5310C
Instrument TypeLaboratory TOC Analyzer
Detection PrincipleMembrane Conductivity Detection
Oxidation MethodUV/Persulfate Oxidation
Measurement Range4 ppb – 50 ppm
Accuracy±2% or ±0.5 ppb (whichever is greater)
Resolution0.01 ppb
Detection Limit4 ppb
Repeatability≤1% RSD
Analysis Time2 minutes
Calibration Interval12 months
Regulatory ComplianceUS EPA Method 415.3 & Standard Methods 5310 C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSievers (Veolia)
OriginUSA
ModelM5310C Online
Detection PrincipleMembrane Conductivity Detection
Oxidation MethodUV/Persulfate
Measurement Range4 ppb – 50 ppm
Accuracy±2% or ±0.5 ppb (whichever is greater)
Resolution0.01 ppb
Detection Limit4 ppb
Repeatability≤1% RSD
Analysis Time2 minutes
Calibration Interval12 months
ComplianceUS EPA Method 415.3 & Standard Methods 5310 C
Instrument TypeOnline TOC Analyzer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPMS
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelLasair III
Instrument TypeHandheld
Flow Rate Options28.3 L/min, 50 L/min, 100 L/min
Flow Accuracy±5%
Timing Accuracy±0.01 s
Repeatability±0.01% RSD
Size Distribution Accuracy±0.01 µm (for calibrated channels)
Indication Accuracy±0.001 particles/m³ (at reference concentration)