- All
- Favorite
- Popular
- Most rated
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | Solutions MD |
| 炉腔级别 | Industrial-Grade |
| Sample Capacity | 15 vessels/batch |
| Microwave Source | Dual Magnetron |
| Max Temperature | 250 °C |
| Max Pressure | 10 MPa |
| Cavity Volume | 53 L |
| Microwave Output Power | 2400 W |
| Temperature Control Range | 0–300 °C |
| Temp. Accuracy | ±0.5 °C (TA), ±1.0 °C (TC) |
| Pressure Control Range | 0–10 MPa (TA), 0–6 MPa (TC) |
| Pressure Accuracy | ±0.01 MPa |
| Cavity Coating | PFA |
| Outer Vessel Material | PEEK+GF |
| Inner Vessel Material | TFM |
| Safety Leakage | <0.3 mW/cm² |
| Cooling Time | ≤25 min |
| Heating Control | PID with Real-Time Feedback |
| Rotation | 360° Bidirectional Motorized Turntable |
| Operating Systems | TC (Microcontroller-Based) or TA (PC-Integrated) |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MD6C-6H |
| Cavity Rating | Industrial-Grade |
| Sample Capacity | 6 vessels |
| Microwave Source | Single Magnetron |
| Max Temperature | 260 °C |
| Max Pressure | 3000 psi (20.7 MPa) |
| Microwave Frequency | 2450 ±13 MHz |
| Output Power | 1200 W (0–100% PID-controlled) |
| Cavity Volume | 45 L |
| Temperature Control Range | 0–300 °C |
| Temp Accuracy | ±0.5 °C |
| Pressure Control Range | 0–6 MPa |
| Pressure Accuracy | ±0.01 MPa |
| Cavity Lining | PFA-coated (Dupont™) |
| Exhaust Flow Rate | 3 m³/min |
| Microwave Leakage | ≤0.3 mW/cm² |
| Safety Features | Dual-pressure relief membranes (200 psi & 400 psi), patented sliding-lock safety door (ZL 200420032536), Pt100 direct-contact temperature sensing, integrated pressure transducer, real-time dual-parameter (T&P) feedback control |
| Vessel Material | Outer — PEEK (10 wt% filler, rated to 10 MPa / 300 °C) |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MD6 |
| Chamber Classification | Industrial-Grade |
| Sample Capacity | 10 vessels |
| Microwave Source | Single Magnetron |
| Max Temperature | 260 °C |
| Max Pressure | 1500 psi |
| Cavity Lining | PFA-coated (DuPont™) |
| External Cooling Airflow | 3 m³/min |
| Microwave Leakage | ≤0.3 mW/cm² |
| Temperature Control Range | 0–300 °C |
| Temp Accuracy | ±0.5 °C |
| Pressure Control Range | 0–10 MPa |
| Pressure Accuracy | ±0.01 MPa |
| Vessel Material | Outer — PEEK (10 MPa rating) |
| Safety Features | Dual-stage pressure relief membrane, patented lateral-sliding safety door (ZL 200420032536), real-time dual-parameter (T&P) monitoring, interlocked door sensor, Pt100 direct-contact temperature sensing, overpressure/overtemperature cut-off |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MD6 Series |
| Sample Capacity | 10 vessels |
| Microwave Source | Single Magnetron |
| Max Temperature | 200 °C |
| Max Pressure | 1500 psi (10.34 MPa) |
| Cavity Volume | 45 L |
| Power Output | 1200 W |
| Frequency | 2450 ±13 MHz |
| Temperature Control Range | 0–300 °C |
| Temp Accuracy | ±0.5 °C |
| Pressure Control Range | 0–6 MPa |
| Pressure Accuracy | ±0.01 MPa |
| Cavity Coating | PFA (DuPont™) |
| Outer Vessel Material | Reinforced PEEK (10 MPa burst rating) |
| Inner Vessel Material | TFM™ (perfluoroalkoxy alkane) |
| Microwave Leakage | ≤0.3 mW/cm² |
| Cooling Airflow | 3 m³/min |
| Safety Features | Dual-stage pressure relief, auto-locking sliding safety door (Patent ZL 200420032536), rupture disc (200/400 psi), real-time Pt100 temperature monitoring, direct-contact pressure transducer, PID-controlled variable-frequency power modulation |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | ME6A |
| Sample Capacity | 1 vessel |
| Microwave Source | Single Magnetron |
| Max Temperature | 300 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Pressure Range | 0–6 MPa |
| Pressure Control Accuracy | ±0.01 MPa |
| Microwave Frequency | 2450 ±13 MHz |
| Output Power | 1200 W (0–100% PID-adjustable) |
| Cavity Volume | 45 L |
| Cavity Lining | Dupont™ PFA-coated |
| Outer Vessel Material | Reinforced PEEK (10 MPa burst rating) |
| Inner Vessel Material | TFM® (perfluoroalkoxy) |
| Safety Features | Dual-stage pressure relief, auto-locking sliding safety door (Patent ZL 200420032536), real-time Pt100 temperature sensing, direct-contact pressure transducer, microwave leakage ≤0.3 mW/cm² |
| Cooling | Forced-air exhaust ≥3 m³/min, <20 min cooldown to safe opening temperature |
| Stirring | 360° reversible turntable + electromagnetic/mechanical dual-mode stirring (0–5000 rpm) |
| Control System | Laptop-based A-type software platform with real-time T/P curve logging, unlimited method storage, and GLP-compliant audit trail |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MP6A |
| Microwave Frequency | 2450 ± 13 MHz |
| Output Power | 1200 W (0–100% PID-controlled) |
| Cavity Volume | 45 L |
| Max Temperature | 260 °C |
| Max Pressure | 1500 psi (10.34 MPa) |
| Sample Capacity | 10 vessels per run |
| Magnetron | Single |
| Cavity Lining | PFA-coated (DuPont™), acid-resistant and high-temperature stable |
| Outer Vessel Material | PEEK (10 MPa burst rating) |
| Inner Vessel Material | TFM® (perfluoroalkoxy alkane, chemically inert) |
| Temperature Control Accuracy | ±0.5 °C |
| Pressure Control Accuracy | ±0.05 MPa |
| Cooling Airflow | 3 m³/min, achieving safe venting temperature within 20 min |
| Door Safety | Patented lateral-release door with dual-stage explosion protection (Patent No. ZL 200420032536) |
| Microwave Leakage | ≤0.3 mW/cm² (IEC 61000-4-3 compliant, well below 5 mW/cm² national limit) |
| Stirring | 360° bidirectional rotating turntable + optional electromagnetic/mechanical stirring (0–5000 rpm) |
| Reaction Vessel Options | 10–1500 mL |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | MICHEM |
|---|---|
| Model | MD8 |
| Origin | Beijing, China |
| Category | Microwave Digestion Instrument |
| Cavity Volume | 53 L (316L stainless steel, dual-sided 6-layer PFA coating) |
| Sample Capacity | 20 samples per batch (switchable 12/20-position rotor) |
| Microwave Source | Dual magnetron (2450 ±13 MHz), max output power 2400 W |
| Max Operating Temperature | 230 °C |
| Max Rated Pressure | 6 MPa (870 psi) |
| Max Burst Pressure | 10 MPa (1450 psi) |
| Temperature Control | PT100 platinum resistance sensor, range 0–300 °C, accuracy ±0.1 °C |
| Pressure Control | High-precision pressure transducer, range 0–10 MPa, accuracy ±0.01 MPa |
| Safety | Horizontal sliding door pressure-release mechanism (Patent ZL200420032536), dual-stage explosion protection, burst disc–based directional venting |
| Cooling & Ventilation | Corrosion-resistant variable-frequency centrifugal fan, airflow 5.8 m³/min |
| Microwave Leakage | ≤0.3 mW/cm² (IEC 61000-4-3 compliant) |
| Control System | Closed-loop PID with real-time frequency modulation |
| Interface | 10″ industrial-grade capacitive touchscreen, USB 2.0 port, SD card slot |
| Software | MDUI-P platform with built-in method library, GLP-compliant audit trail, auto-diagnostic routines, and adaptive cooling/fume extraction logic |
| Power Supply | 220 V, 50/60 Hz, 16 A, rated input 3600 W |
| Dimensions (W×D×H) | 650 × 675 × 650 mm |
| Net Weight | 80 kg |
| Digestion Vessel | Frame-type high-pressure rotor |
| operating temp/pressure | 230 °C / 6 MPa |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MP Series |
| Microwave Frequency | 2450 ± 13 MHz |
| Output Power | 1200 W (0–100% PID-controlled) |
| Cavity Volume | 45 L |
| Max Temperature | 260 °C |
| Max Pressure | 1500 psi (10.34 MPa) |
| Sample Capacity | 10 vessels per run |
| Magnetron | Single |
| Cavity Coating | PFA (DuPont™) |
| Outer Vessel Material | PEEK (10 MPa rating) |
| Inner Vessel Material | TFM™ (perfluoroalkoxy alkane) |
| Temperature Control Accuracy | ±0.5 °C (Pt100 sensor) |
| Pressure Control Accuracy | ±0.01 MPa (direct-contact transducer) |
| Microwave Leakage | ≤0.3 mW/cm² |
| Cooling Airflow | 3 m³/min |
| Safety Features | Dual-stage pressure relief membrane, self-locking sliding safety door (Patent ZL 200420032536), real-time temperature/pressure dual monitoring, over-pressure/over-temperature cut-off, cavity interlock, and fail-safe power shutdown |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MP6C |
| Microwave Frequency | 2450 ± 13 MHz |
| Output Power | 1200 W (0–100% PID-controlled) |
| Cavity Volume | 45 L |
| Max Temperature | 260 °C |
| Max Pressure | 1500 psi (10.34 MPa) |
| Sample Capacity | 10 vessels per run |
| Microwave Source | Single Magnetron |
| Cavity Lining | PFA-coated (DuPont™) |
| Outer Vessel Material | Reinforced PEEK (10 MPa burst rating) |
| Inner Vessel Material | TFM® (perfluoroalkoxy alkane) |
| Temperature Control | Pt100 RTD, ±0.5 °C accuracy (0–300 °C range) |
| Pressure Control | Direct-contact sensor, 0.01 MPa resolution |
| Safety Features | Six-layer protection including dual-stage pressure relief, auto-shutoff at overpressure, patented sliding-lock safety door (ZL 200420032536), microwave leakage ≤0.3 mW/cm² |
| Cooling | Forced-air exhaust, 3 m³/min, <20 min to safe opening temperature |
| Stirring | 360° bidirectional rotating carousel + optional electromagnetic/mechanical stirring (0–5000 rpm) |
| Control System | Embedded microcontroller (MP6C variant) with 15 pre-programmable methods (8-step ramping), real-time T/P curve display, method storage |
| Brand | MICHEM |
|---|---|
| Model | MD Series |
| Origin | Beijing, China |
| Microwave Frequency | 2450 ±13 MHz |
| Output Power | 1200 W |
| Power Control | 0–100% PID Automatic Continuous Adjustment |
| Cavity Volume | 45 L |
| Dimensions (W×D×H) | 490 × 610 × 610 mm |
| Net Weight | 48 kg |
| Temperature Range | 0–300 °C |
| Temperature Accuracy | ±0.5 °C |
| Pressure Range | 0–6 MPa |
| Pressure Accuracy | ±0.05 MPa |
| Microwave Leakage | ≤0.3 mW/cm² |
| Cavity Coating | Dupont PFA |
| Outer Vessel Material | PEEK (10 MPa burst rating) |
| Inner Vessel Material | TFM (chemically resistant, up to 300 °C) |
| Cooling Airflow | 3 m³/min (cooling to safe opening temperature within 20 min) |
| Door Mechanism | Patented lateral-release safety door with dual-stage explosion protection (Patent No.: ZL 200420032536) |
| Stirring | 360° reversible turntable |
| Reaction Vessel Capacity | 10–1500 mL (standard 500 mL) |
| Control Options | A-type (laptop-based software with real-time T/P curve monitoring, unlimited method storage) |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MD6 |
| Sample Capacity | 6–10 vessels |
| Microwave Source | Dual-Magnetron |
| Max Temperature | 260 °C |
| Max Pressure | 2200 psi |
| Cavity Lining | PFA-coated (DuPont™) |
| Temperature Control Range | 0–300 °C |
| Temp Accuracy | ±0.5 °C |
| Pressure Control Range | 0–6 MPa |
| Pressure Accuracy | ±0.01 MPa |
| Microwave Leakage | ≤0.3 mW/cm² |
| Output Power | 1200 W (0–100% PID-adjustable) |
| Cavity Volume | 45 L |
| Dimensions (W×D×H) | 490×610×610 mm |
| Weight | 48 kg |
| Cooling Airflow | 3 m³/min |
| Safety | Six-layer protection including dual-stage pressure relief, auto-locking blast-resistant door (Patent ZL 200420032536), rupture disc, and real-time Pt100/pressure dual-sensor feedback |
| Brand | MICHEM |
|---|---|
| Model | MD6 |
| Origin | Beijing, China |
| Microwave Frequency | 2450 ± 13 MHz |
| Output Power | 1200 W |
| Power Control | 0–100% PID automatic continuous adjustment |
| Cavity Volume | 45 L |
| Dimensions (W×D×H) | 490 × 610 × 610 mm |
| Net Weight | 48 kg |
| Temperature Range | 0–300 °C |
| Temperature Accuracy | ±0.5 °C |
| Pressure Range | 0–6 MPa (900 psi) |
| Pressure Accuracy | ±0.01 MPa |
| Cavity Coating | PFA (DuPont™) |
| Microwave Leakage | ≤0.3 mW/cm² |
| Safety Features | Dual-stage explosion-proof door (Patent ZL 200420032536), rupture disk pressure relief, Pt100 direct-contact temperature sensing, real-time dual-parameter (T&P) monitoring |
| Vessel Configuration | PEEK outer vessel (10 MPa rating), TFM inner vessel (chemically inert, 300 °C stable) |
| Rotation | 360° reversible turntable with magnetic & mechanical stirring (0–5000 rpm) |
| Sample Capacity | Up to 10 vessels per run (standard: 4 or 6 vessels |
| volume range | 10–1500 mL) |
| Control Options | A-type laptop-based software interface (unlimited method storage, real-time T&P curve logging) or C-type microcontroller (15 pre-programmed methods, 8-step ramping) |
| Ventilation | 3 m³/min forced-air cooling, <20 min cooldown to safe opening temperature |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MD6C |
| Sample Capacity | 10 vessels |
| Microwave Source | Single Magnetron |
| Max Temperature | 200 °C |
| Max Pressure | 3.0 MPa |
| Cavity Classification | Industrial-Grade |
| Control System | Microprocessor-Based PID with Digital Display |
| Temperature Accuracy | ±0.5 °C |
| Pressure Accuracy | ±0.01 MPa |
| Cavity Lining | PFA-coated (DuPont™) |
| External Cooling Airflow | 3 m³/min |
| Microwave Leakage | ≤0.3 mW/cm² |
| Safety Features | Dual-stage pressure relief, auto-locking blast-resistant door (Patent ZL 200420032536), rupture disc protection (200/400 psi), integrated Pt100 temperature sensor & direct-contact pressure transducer |
| Vessel Material | Outer — PEEK (10 MPa rating) |
| Power Input | AC 220 V / 50 Hz / 10 A |
| Output Power | 1200 W (0–100% PID-adjustable) |
| Cavity Volume | 45 L |
| Dimensions (W×D×H) | 490 × 610 × 610 mm |
| Weight | 48 kg |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MD6 |
| Microwave Frequency | 2450 ±13 MHz |
| Output Power | 1200 W |
| Power Control | 0–100% PID automatic continuous adjustment |
| Cavity Volume | 45 L |
| Dimensions (W×D×H) | 490 × 610 × 610 mm |
| Net Weight | 48 kg |
| Temperature Range | 0–300 °C |
| Temperature Accuracy | ±0.5 °C |
| Pressure Range | 0–6 MPa |
| Pressure Accuracy | ±0.01 MPa |
| Cavity Coating | PFA (DuPont™) |
| Microwave Leakage | ≤0.3 mW/cm² |
| Safety Features | Dual-stage explosion-proof door (Patent ZL 200420032536), rupture disc pressure relief, Pt100 direct-contact temperature sensing, integrated pressure transducer, interlocked safety door, modular control architecture |
| Vessel Configuration | PEEK outer vessel (10 MPa rating), TFM inner vessel (chemically inert, 300 °C stable) |
| Rotating Turntable | 360° bidirectional, motor-driven, optical feedback control |
| Stirring | Electromagnetic + mechanical dual-mode, 0–5000 rpm adjustable |
| Max. Simultaneous Samples | 6 or 10 (configurable) |
| Ventilation | 3 m³/min, <20 min cooldown to safe opening temperature |
| Compliance | Meets GB 4706.21 (China), IEC 61000-4 series EMC standards, and general requirements for laboratory microwave equipment per ISO/IEC 17025 supporting infrastructure |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MD6T |
| Batch Capacity | 10 samples |
| Microwave Source | Dual Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 10.34 MPa (1500 psi) |
| Cavity Volume | 45 L |
| Cavity Material | 316L Stainless Steel with Dual-Side 6-Layer Imported PFA Coating |
| Microwave Output Power | 1200 W |
| Frequency | 2450 ±13 MHz |
| Temperature Control | Platinum RTD Sensor (0–300 °C, ±0.5 °C) |
| Pressure Control | High-Accuracy Transducer (0–10 MPa, ±0.01 MPa) |
| Safety | Patented Horizontal-Shift Door Pressure Release Mechanism (ZL200420032536), Dual-Stage Explosion Protection |
| Cooling | Corrosion-Resistant Variable-Speed Centrifugal Fan (5.3 m³/min) |
| Microwave Leakage | ≤0.3 mW/cm² |
| Control Interface | 8″ Industrial Touchscreen |
| Control Algorithm | Closed-Loop PID |
| Ramp Rate | 1–20 °C/min |
| Data Interface | RS232 (9-pin) |
| Dimensions (W×D×H) | 650×675×650 mm |
| Net Weight | 75 kg |
| Power Supply | 220 V, 50/60 Hz, 16 A |
| Rated Input Power | 1800 W |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | ME6C |
| Microwave Frequency | 2450 ± 13 MHz |
| Output Power | 1200 W (0–100% PID-controlled) |
| Maximum Temperature | 300 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Pressure Control Range | 0–6 MPa (≈900 psi) |
| Pressure Control Accuracy | ±0.01 MPa |
| Cavity Volume | 45 L |
| Cavity Coating | Dupont PFA (perfluoroalkoxy) |
| Outer Vessel Material | Reinforced PEEK (10 MPa rating) |
| Inner Vessel Material | TFM (high-purity modified PTFE) |
| Safety Features | Six-layer protection including dual-pressure/temperature monitoring, auto-shutdown on overpressure, rupture disc, patented lateral-release safety door (ZL 200420032536), waveguide attenuator, and cavity interlock |
| Microwave Leakage | ≤0.3 mW/cm² |
| Cooling Airflow | 3 m³/min (reaches safe opening temperature within 20 min) |
| Sample Capacity | 1 vessel (standard configuration) |
| Stirring | Dual-mode (electromagnetic + mechanical), 0–5000 rpm, 360° reversible rotation |
| Control System | Microprocessor-based (C-type), LED display, 15 pre-programmable methods, 8-step ramping per method |
| Compliance | Meets GB/T 18801–2015 (China), IEC 61000-6-3, and general requirements for ISO/IEC 17025-accredited laboratories |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MP6T |
| Chamber Rating | Industrial-Grade |
| Sample Capacity | 10 vessels |
| Microwave Source | Single Magnetron |
| Max Temperature | 260 °C |
| Max Pressure | 1500 psi |
| Cavity Coating | PFA (DuPont) |
| Outer Vessel Material | PEEK (10 MPa rating) |
| Inner Vessel Material | TFM |
| Temperature Control Range | 0–300 °C |
| Temp Accuracy | ±0.5 °C |
| Pressure Control Range | 0–9 MPa (1305 psi) |
| Pressure Resolution | 0.01 MPa |
| Microwave Leakage | ≤0.3 mW/cm² |
| Cooling Airflow | 3 m³/min |
| Rotational Stirring | 0–5000 rpm (bidirectional, electromagnetic + mechanical) |
| Control Options | Laptop-based A-type software or C-type microcontroller (15 pre-programmed methods, 8-step ramping) |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MD6A |
| Price Range | USD 7,000–14,000 (FOB) |
| Cavity Class | Industrial-Grade |
| Max. Sample Capacity | 10 vessels |
| Microwave Source | Single Magnetron |
| Max. Temperature | 200 °C |
| Max. Pressure | 1500 psi |
| Cavity Lining | PFA-coated (DuPont™) |
| External Cooling Airflow | 3 m³/min |
| Microwave Leakage | ≤0.3 mW/cm² |
| Safety Features | Dual-stage pressure relief door (Patent ZL 200420032536), rupture disc protection (200/400 psi), Pt100 contact temperature sensing (0–300 °C, ±0.5 °C), direct-contact pressure transducer (0–900 psi, ±0.01 MPa) |
| Vessel Materials | Outer — PEEK (10 MPa burst rating) |
| Control System | A-type laptop-based software with real-time T/P curve logging, unlimited method storage, and multi-step ramp/hold programming |