- All
- Favorite
- Popular
- Most rated
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | Solutions MD |
| 炉腔级别 | Industrial-Grade |
| Sample Capacity | 15 vessels/batch |
| Microwave Source | Dual Magnetron |
| Max Temperature | 250 °C |
| Max Pressure | 10 MPa |
| Cavity Volume | 53 L |
| Microwave Output Power | 2400 W |
| Temperature Control Range | 0–300 °C |
| Temp. Accuracy | ±0.5 °C (TA), ±1.0 °C (TC) |
| Pressure Control Range | 0–10 MPa (TA), 0–6 MPa (TC) |
| Pressure Accuracy | ±0.01 MPa |
| Cavity Coating | PFA |
| Outer Vessel Material | PEEK+GF |
| Inner Vessel Material | TFM |
| Safety Leakage | <0.3 mW/cm² |
| Cooling Time | ≤25 min |
| Heating Control | PID with Real-Time Feedback |
| Rotation | 360° Bidirectional Motorized Turntable |
| Operating Systems | TC (Microcontroller-Based) or TA (PC-Integrated) |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Type | Box-Type Muffle Furnace |
| Max Temperature | 1000°C |
| Temperature Uniformity | ±1°C |
| Power Rating | 2 kW (6 L) / 3 kW (9 L) / 5 kW (20 L) / 6 kW (30 L) |
| Heating Rate to Max Temp | ≤30 min (6 L, 9 L, 20 L) / ≤40 min (30 L) |
| Heating Element | HRE High-Temperature Alloy Wire |
| Internal Chamber Dimensions | 200×250×120 mm (6 L) / 200×300×150 mm (9 L) / 250×400×200 mm (20 L) / 300×400×250 mm (30 L) |
| External Dimensions & Weight | 550×530×430 mm / 52 kg (6 L) |
| Power Supply | 220 V / 16 A (6 L, 9 L) or 380 V / 16 A (20 L, 30 L) |
| Insulation | Ceramic Fiber (80–130 mm thickness) |
| Thermocouple Type | K-type (≤1200°C) or S-type (≤1400°C) |
| Brand | MICHEM |
|---|---|
| Model | DR-15 / DR-24 / DR-54 |
| Heating Material | PTFE-Coated Graphite |
| Max Temperature | 240 °C |
| Temperature Accuracy | ±1.0 °C |
| Heating Uniformity | ±2.0 °C across block |
| Control System | 30-Step PID Digital Programmable Controller |
| Sample Capacity | 15 × 100 mL (DR-15) |
| Power Rating | 1200 W (DR-15/DR-24) / 3000 W (DR-54) |
| Input Voltage | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 470×350×270 mm (DR-15/DR-24) / 670×460×270 mm (DR-54) |
| Compliance | Designed for ISO/IEC 17025-compliant sample preparation workflows |
| Application Scope | Acid digestion, post-microwave acid removal (acid evaporation), and controlled thermal pretreatment prior to AAS, AFSS, ICP-OES, and ICP-MS analysis |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MD6C-6H |
| Cavity Rating | Industrial-Grade |
| Sample Capacity | 6 vessels |
| Microwave Source | Single Magnetron |
| Max Temperature | 260 °C |
| Max Pressure | 3000 psi (20.7 MPa) |
| Microwave Frequency | 2450 ±13 MHz |
| Output Power | 1200 W (0–100% PID-controlled) |
| Cavity Volume | 45 L |
| Temperature Control Range | 0–300 °C |
| Temp Accuracy | ±0.5 °C |
| Pressure Control Range | 0–6 MPa |
| Pressure Accuracy | ±0.01 MPa |
| Cavity Lining | PFA-coated (Dupont™) |
| Exhaust Flow Rate | 3 m³/min |
| Microwave Leakage | ≤0.3 mW/cm² |
| Safety Features | Dual-pressure relief membranes (200 psi & 400 psi), patented sliding-lock safety door (ZL 200420032536), Pt100 direct-contact temperature sensing, integrated pressure transducer, real-time dual-parameter (T&P) feedback control |
| Vessel Material | Outer — PEEK (10 wt% filler, rated to 10 MPa / 300 °C) |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MC-7000C |
| Instrument Type | Split-System Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | 5–35 °C |
| Cooling Capacity | 7000 W |
| Temperature Stability | ±0.1 °C |
| Circulation Pump Pressure | 7 bar |
| Circulation Flow Rate | 6 L/min |
| Reservoir Volume | 80 L |
| Operation Mode | Continuous |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MD6 |
| Chamber Classification | Industrial-Grade |
| Sample Capacity | 10 vessels |
| Microwave Source | Single Magnetron |
| Max Temperature | 260 °C |
| Max Pressure | 1500 psi |
| Cavity Lining | PFA-coated (DuPont™) |
| External Cooling Airflow | 3 m³/min |
| Microwave Leakage | ≤0.3 mW/cm² |
| Temperature Control Range | 0–300 °C |
| Temp Accuracy | ±0.5 °C |
| Pressure Control Range | 0–10 MPa |
| Pressure Accuracy | ±0.01 MPa |
| Vessel Material | Outer — PEEK (10 MPa rating) |
| Safety Features | Dual-stage pressure relief membrane, patented lateral-sliding safety door (ZL 200420032536), real-time dual-parameter (T&P) monitoring, interlocked door sensor, Pt100 direct-contact temperature sensing, overpressure/overtemperature cut-off |
| Brand | MICHEM |
|---|---|
| Model | DR-15 / DR-24 / DR-54 |
| Heating Material | PTFE-Coated Graphite |
| Max Power | 1200 W (DR-15, DR-24) / 3000 W (DR-54) |
| Control | 30-Step PID Digital Temperature Controller |
| Max Temp | 240 °C |
| Temp Accuracy | ±1.0 °C |
| Sample Capacity | 15×100 mL (DR-15) / 24×50 mL (DR-24) / 54×50 mL (DR-54) |
| Well Dimensions | Φ42×40 mm (DR-15) / Φ26×40 mm (DR-24) / Φ23×40 mm (DR-54) |
| Power Supply | AC 220 V, 50 Hz, 10 A (DR-15/DR-24) / 16 A (DR-54) |
| Dimensions (W×D×H) | 470×350×270 mm (DR-15/DR-24) / 670×460×270 mm (DR-54) |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Instrument Type | Box-Type Muffle Furnace |
| Heating Element | Resistance Wire (up to 1400 °C) / Silicon Molybdenum Rod (1700 °C) |
| Temperature Range | 100–1700 °C |
| Chamber Volume | 4–30 L |
| Power Input | 2–7 kW |
| Max. Insulation Thickness | 140 mm |
| External Power Supply | 220 V/16–25 A or 380 V/16 A (3-phase) |
| Temperature Uniformity | ±2 °C at setpoint |
| Controller | PID-based multi-step programmable controller (30 segments), stability ≤0.2% FS |
| Thermocouple Types | K (≤1200 °C), S (≤1400 °C), B (≤1700 °C) |
| Weight | 52–110 kg |
| Internal Dimensions (W×D×H) | 160×170×150 mm to 300×400×250 mm |
| External Dimensions (W×D×H) | 550×530×430 mm to 710×760×640 mm |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MW-D50 |
| Output Flow Rate | 50 L/h |
| Pure Water Resistivity | 1–5 µS/cm |
| Ultra-Pure Water Resistivity | 18.25 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | ≤ 10 ppb |
| Endotoxin | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| Microbial Count | ≤ 1 CFU/mL |
| Feed Water Requirement | Municipal tap water, TDS < 360 ppm, pressure > 0.2 MPa |
| Power Supply | AC 220 V / 50 Hz / 5 A |
| Dimensions (W×D×H) | 560 × 680 × 1105 mm |
| Resin Cycle Yield | 16 tons |
| Pump Noise Level | < 20 dB(A) |
| Conductivity Sensor | 0.01 cm⁻¹ stainless steel electrode, temperature compensation ±0.1 °C |
| Optional Terminal Filtration | Sartorius 0.22 µm filter |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MD6 Series |
| Sample Capacity | 10 vessels |
| Microwave Source | Single Magnetron |
| Max Temperature | 200 °C |
| Max Pressure | 1500 psi (10.34 MPa) |
| Cavity Volume | 45 L |
| Power Output | 1200 W |
| Frequency | 2450 ±13 MHz |
| Temperature Control Range | 0–300 °C |
| Temp Accuracy | ±0.5 °C |
| Pressure Control Range | 0–6 MPa |
| Pressure Accuracy | ±0.01 MPa |
| Cavity Coating | PFA (DuPont™) |
| Outer Vessel Material | Reinforced PEEK (10 MPa burst rating) |
| Inner Vessel Material | TFM™ (perfluoroalkoxy alkane) |
| Microwave Leakage | ≤0.3 mW/cm² |
| Cooling Airflow | 3 m³/min |
| Safety Features | Dual-stage pressure relief, auto-locking sliding safety door (Patent ZL 200420032536), rupture disc (200/400 psi), real-time Pt100 temperature monitoring, direct-contact pressure transducer, PID-controlled variable-frequency power modulation |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | TM1700 Series |
| Furnace Type | Box-Type Muffle Furnace |
| Max Operating Temperature | 1700 °C |
| Temperature Uniformity | ±1 °C (at 1700 °C, steady state) |
| Heating Element | Silicon-Molybdenum (MoSi₂) Rods |
| Internal Chamber Volume | 4 L (160×170×150 mm), 6 L (160×250×150 mm), or 9 L (200×300×150 mm) |
| Max Power Input | 7.5 kW |
| Ramp Time to 1700 °C | ≤90 min (from ambient) |
| Insulation Material | High-Purity Alumina-Silica Ceramic Fiber (density: ~128 kg/m³) |
| External Surface Temp (at 1000 °C hold) | ≤60 °C |
| Control System | 30-Step Programmable PID Controller (PP3 series) with ramp-soak profiling, 0.2% FS stability, 9999 min/step timer |
| Safety Features | Automatic power cutoff upon door opening, over-temperature cutout, grounded chassis |
| Compliance | Designed for GLP-compliant thermal processing |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MW-D30 |
| Output Flow Rate | 30 L/h |
| Feed Water | Municipal tap water (TDS < 360 ppm, pressure > 0.2 MPa) |
| Pure Water Resistivity | 1–5 µS/cm |
| Ultra-Pure Water Resistivity | ≥18.25 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | ≤10 ppb |
| Endotoxin | < 0.001 EU/mL |
| Microbial Count | < 1 CFU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| UV Lamp | 185/254 nm dual-wavelength |
| Conductivity Sensor | 0.01 cm⁻¹ stainless steel electrode, ±0.1 °C temperature compensation |
| Optional Terminal Filter | Sartorius 0.22 µm |
| Power Supply | AC 220 V / 50 Hz / 5 A |
| Dimensions (W×D×H) | 500 × 565 × 1040 mm |
| Noise Level | < 20 dB(A) |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | TF10 |
| Instrument Type | Horizontal Tube Furnace |
| Maximum Temperature | 1000°C |
| Temperature Control Accuracy | ±1°C |
| Rated Power | 2500 W |
| Heating Rate to Max Temp | ≤40 min |
| Heating Element | HRE High-Temperature Alloy |
| Internal Dimensions | Ø60×54×1000 mm / Ø80×74×1000 mm / Ø100×94×1000 mm |
| Brand | MechaTech |
|---|---|
| Origin | United Kingdom |
| Model | LSMC55 / LSMC85 |
| Type | Standard Shelf-Type Freeze Dryer |
| Application | Pilot-Scale |
| Lyophilization Area | 44.5 L |
| Ultimate Vacuum | <20 Pa |
| Condensate Capacity (24 h) | 44.5 L |
| Condenser Temperature | –55 °C (LSMC55) / –85 °C (LSMC85) |
| Dimensions (W×D×H) | 945 × 700 × 950 mm |
| Construction | Stainless Steel (AISI 304) |
| Defrost Method | Hot-Gas Auto-Defrost |
| Interface | Integrated Touchscreen Control Panel with Real-Time Display of Vacuum (mbar, Torr, Pa) and Temperature (°C/°F) |
| Compliance | Designed to Support GLP/GMP-Compliant Workflows |
| Mobility | Equipped with Locking Casters |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | TM06 Series |
| Type | Box-Type Muffle Furnace |
| Max Temperature | 1000 °C / 1200 °C / 1400 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 2 kW |
| Heating Rate (to max temp) | 30 min (1000 °C) / 40 min (1200 °C) / 50 min (1400 °C) |
| Heating Element | HRE Alloy (Fe-Cr-Al) |
| Internal Chamber Dimensions | 200 × 250 × 120 mm (W × D × H) |
| Insulation | High-Purity Ceramic Fiber (80–140 mm thickness) |
| Thermocouple Type | K-type (up to 1200 °C), S-type (up to 1400 °C), B-type (up to 1700 °C) |
| Power Supply | 220 V AC, 16 A single-phase |
| Net Weight | 52 kg |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | ME6A |
| Sample Capacity | 1 vessel |
| Microwave Source | Single Magnetron |
| Max Temperature | 300 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Pressure Range | 0–6 MPa |
| Pressure Control Accuracy | ±0.01 MPa |
| Microwave Frequency | 2450 ±13 MHz |
| Output Power | 1200 W (0–100% PID-adjustable) |
| Cavity Volume | 45 L |
| Cavity Lining | Dupont™ PFA-coated |
| Outer Vessel Material | Reinforced PEEK (10 MPa burst rating) |
| Inner Vessel Material | TFM® (perfluoroalkoxy) |
| Safety Features | Dual-stage pressure relief, auto-locking sliding safety door (Patent ZL 200420032536), real-time Pt100 temperature sensing, direct-contact pressure transducer, microwave leakage ≤0.3 mW/cm² |
| Cooling | Forced-air exhaust ≥3 m³/min, <20 min cooldown to safe opening temperature |
| Stirring | 360° reversible turntable + electromagnetic/mechanical dual-mode stirring (0–5000 rpm) |
| Control System | Laptop-based A-type software platform with real-time T/P curve logging, unlimited method storage, and GLP-compliant audit trail |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | DR-6G |
| Digestion Type | Graphite-block Electric Heating |
| Automation Level | Semi-Automatic |
| Digestion Positions | 6 or 8 |
| Max Temperature | 260 °C |
| Temperature Accuracy | ±1.0 °C |
| Heating Mechanism | Electric heating plate + graphite thermal conduction block + infrared auxiliary heating |
| Surface Coating | PTFE (Teflon®)-coated graphite |
| Rated Power | 1200 W (DR-6G) |
| Input Voltage | AC 220 V, 16 A |
| Dimensions (L×W×H) | 470×350×270 mm (DR-6G) |
| Sample Vessel Capacity | 100 mL × 6 or × 8 |
| Pressure Vessel Compatibility | Dual-layer sealed reaction vessels rated to 10 MPa |
| Compliance | Meets GB/T 150 (China National Standard for Pressure Vessels) |
| Brand | MICHEM |
|---|---|
| Model | KMK-Y-I |
| Origin | Beijing, China |
| Purification Capacity | 1–4 m³/h |
| Inlet Pressure Range | 0.2–1 MPa |
| Output Purity | ≥99.9999% (N₂ ≤ 0.2 ppm, O₂ ≤ 0.3 ppm, CO/CO₂/CH₄ ≤ 0.2 ppm each, Dew Point ≤ −80 °C) |
| Power Supply | 220 V / 50 Hz |
| Power Consumption | 2.2 kW |
| Dimensions (L×W×H) | 500×500×900 mm |
| Weight | 48 kg |
| Compliance | GB/T 4842–2006 |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MP6A |
| Microwave Frequency | 2450 ± 13 MHz |
| Output Power | 1200 W (0–100% PID-controlled) |
| Cavity Volume | 45 L |
| Max Temperature | 260 °C |
| Max Pressure | 1500 psi (10.34 MPa) |
| Sample Capacity | 10 vessels per run |
| Magnetron | Single |
| Cavity Lining | PFA-coated (DuPont™), acid-resistant and high-temperature stable |
| Outer Vessel Material | PEEK (10 MPa burst rating) |
| Inner Vessel Material | TFM® (perfluoroalkoxy alkane, chemically inert) |
| Temperature Control Accuracy | ±0.5 °C |
| Pressure Control Accuracy | ±0.05 MPa |
| Cooling Airflow | 3 m³/min, achieving safe venting temperature within 20 min |
| Door Safety | Patented lateral-release door with dual-stage explosion protection (Patent No. ZL 200420032536) |
| Microwave Leakage | ≤0.3 mW/cm² (IEC 61000-4-3 compliant, well below 5 mW/cm² national limit) |
| Stirring | 360° bidirectional rotating turntable + optional electromagnetic/mechanical stirring (0–5000 rpm) |
| Reaction Vessel Options | 10–1500 mL |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | TM Series 1400 |
| Type | Box-Type Muffle Furnace |
| Max Temperature | 1400°C |
| Temperature Control Accuracy | ±1°C |
| Power Rating | 2 kW (6 L) / 3 kW (9 L) / 5 kW (20 L) / 6 kW (30 L) |
| Heating Element | HRE Ultra-High-Temperature Alloy |
| Internal Dimensions | 200×250×120 mm (6 L) / 200×300×150 mm (9 L) / 250×400×200 mm (20 L) / 300×400×250 mm (30 L) |
| Ramp Time to Max Temp | ≤50 min (6 L & 9 L) / ≤60 min (20 L) / ≤80 min (30 L) |
| Insulation | High-Density Ceramic Fiber (100–130 mm thickness) |
| Voltage/Current | 220 V / 16 A (6 L & 9 L) |
| Weight | 55 kg (6 L) / 70 kg (9 L) / 85 kg (20 L) / 98 kg (30 L) |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | TF10 Series |
| Maximum Temperature | 1000 °C |
| Temperature Control Accuracy | ±1 °C |
| Rated Power | 2500 W |
| Heating Time to Max Temp | ≤40 min |
| Heating Element | HRE High-Temperature Alloy |
| Internal Dimensions | Ø60×54×1000 mm / Ø80×74×1000 mm / Ø100×94×1000 mm |
| Cooling Method | Forced-air assisted passive cooling |
| Vacuum Compatibility | Up to 10⁻³ mbar (with optional vacuum pump & sealing kit) |
| Safety Features | Door-interlocked power cutoff, over-temperature protection, grounded chassis |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MC-2500BP |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Control Range | 5–35 °C |
| Temperature Stability | ±0.1 °C |
| Refrigeration Capacity | 2500 W |
| Circulation Pump Pressure | 7 bar |
| Circulation Flow Rate | 6 L/min |
| Reservoir Volume | 10 L |
| Operating Mode | Continuous |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | TM30 Series |
| Instrument Type | Box Furnace |
| Maximum Temperature | 1000 °C / 1200 °C / 1400 °C |
| Temperature Control Accuracy | ±1 °C |
| Maximum Power | 6 kW |
| Heating Time to Max Temp | 40 min (1000 °C) / 60 min (1200 °C) / 80 min (1400 °C) |
| Heating Element | HRE high-temperature alloy |
| Internal Chamber Dimensions | 300 × 400 × 250 mm (W × D × H) |
| Brand | MICHEM |
|---|---|
| Model | MD8 |
| Origin | Beijing, China |
| Category | Microwave Digestion Instrument |
| Cavity Volume | 53 L (316L stainless steel, dual-sided 6-layer PFA coating) |
| Sample Capacity | 20 samples per batch (switchable 12/20-position rotor) |
| Microwave Source | Dual magnetron (2450 ±13 MHz), max output power 2400 W |
| Max Operating Temperature | 230 °C |
| Max Rated Pressure | 6 MPa (870 psi) |
| Max Burst Pressure | 10 MPa (1450 psi) |
| Temperature Control | PT100 platinum resistance sensor, range 0–300 °C, accuracy ±0.1 °C |
| Pressure Control | High-precision pressure transducer, range 0–10 MPa, accuracy ±0.01 MPa |
| Safety | Horizontal sliding door pressure-release mechanism (Patent ZL200420032536), dual-stage explosion protection, burst disc–based directional venting |
| Cooling & Ventilation | Corrosion-resistant variable-frequency centrifugal fan, airflow 5.8 m³/min |
| Microwave Leakage | ≤0.3 mW/cm² (IEC 61000-4-3 compliant) |
| Control System | Closed-loop PID with real-time frequency modulation |
| Interface | 10″ industrial-grade capacitive touchscreen, USB 2.0 port, SD card slot |
| Software | MDUI-P platform with built-in method library, GLP-compliant audit trail, auto-diagnostic routines, and adaptive cooling/fume extraction logic |
| Power Supply | 220 V, 50/60 Hz, 16 A, rated input 3600 W |
| Dimensions (W×D×H) | 650 × 675 × 650 mm |
| Net Weight | 80 kg |
| Digestion Vessel | Frame-type high-pressure rotor |
| operating temp/pressure | 230 °C / 6 MPa |
Show next