Add to compare
BrandMICHEM
OriginBeijing, China
ModelSolutions MD
炉腔级别Industrial-Grade
Sample Capacity15 vessels/batch
Microwave SourceDual Magnetron
Max Temperature250 °C
Max Pressure10 MPa
Cavity Volume53 L
Microwave Output Power2400 W
Temperature Control Range0–300 °C
Temp. Accuracy±0.5 °C (TA), ±1.0 °C (TC)
Pressure Control Range0–10 MPa (TA), 0–6 MPa (TC)
Pressure Accuracy±0.01 MPa
Cavity CoatingPFA
Outer Vessel MaterialPEEK+GF
Inner Vessel MaterialTFM
Safety Leakage<0.3 mW/cm²
Cooling Time≤25 min
Heating ControlPID with Real-Time Feedback
Rotation360° Bidirectional Motorized Turntable
Operating SystemsTC (Microcontroller-Based) or TA (PC-Integrated)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
ModelDR-15 / DR-24 / DR-54
Heating MaterialPTFE-Coated Graphite
Max Temperature240 °C
Temperature Accuracy±1.0 °C
Heating Uniformity±2.0 °C across block
Control System30-Step PID Digital Programmable Controller
Sample Capacity15 × 100 mL (DR-15)
Power Rating1200 W (DR-15/DR-24) / 3000 W (DR-54)
Input VoltageAC 220 V, 50 Hz
Dimensions (W×D×H)470×350×270 mm (DR-15/DR-24) / 670×460×270 mm (DR-54)
ComplianceDesigned for ISO/IEC 17025-compliant sample preparation workflows
Application ScopeAcid digestion, post-microwave acid removal (acid evaporation), and controlled thermal pretreatment prior to AAS, AFSS, ICP-OES, and ICP-MS analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
OriginBeijing, China
ModelMD6C-6H
Cavity RatingIndustrial-Grade
Sample Capacity6 vessels
Microwave SourceSingle Magnetron
Max Temperature260 °C
Max Pressure3000 psi (20.7 MPa)
Microwave Frequency2450 ±13 MHz
Output Power1200 W (0–100% PID-controlled)
Cavity Volume45 L
Temperature Control Range0–300 °C
Temp Accuracy±0.5 °C
Pressure Control Range0–6 MPa
Pressure Accuracy±0.01 MPa
Cavity LiningPFA-coated (Dupont™)
Exhaust Flow Rate3 m³/min
Microwave Leakage≤0.3 mW/cm²
Safety FeaturesDual-pressure relief membranes (200 psi & 400 psi), patented sliding-lock safety door (ZL 200420032536), Pt100 direct-contact temperature sensing, integrated pressure transducer, real-time dual-parameter (T&P) feedback control
Vessel MaterialOuter — PEEK (10 wt% filler, rated to 10 MPa / 300 °C)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
OriginBeijing, China
ModelMD6
Chamber ClassificationIndustrial-Grade
Sample Capacity10 vessels
Microwave SourceSingle Magnetron
Max Temperature260 °C
Max Pressure1500 psi
Cavity LiningPFA-coated (DuPont™)
External Cooling Airflow3 m³/min
Microwave Leakage≤0.3 mW/cm²
Temperature Control Range0–300 °C
Temp Accuracy±0.5 °C
Pressure Control Range0–10 MPa
Pressure Accuracy±0.01 MPa
Vessel MaterialOuter — PEEK (10 MPa rating)
Safety FeaturesDual-stage pressure relief membrane, patented lateral-sliding safety door (ZL 200420032536), real-time dual-parameter (T&P) monitoring, interlocked door sensor, Pt100 direct-contact temperature sensing, overpressure/overtemperature cut-off
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
ModelDR-15 / DR-24 / DR-54
Heating MaterialPTFE-Coated Graphite
Max Power1200 W (DR-15, DR-24) / 3000 W (DR-54)
Control30-Step PID Digital Temperature Controller
Max Temp240 °C
Temp Accuracy±1.0 °C
Sample Capacity15×100 mL (DR-15) / 24×50 mL (DR-24) / 54×50 mL (DR-54)
Well DimensionsΦ42×40 mm (DR-15) / Φ26×40 mm (DR-24) / Φ23×40 mm (DR-54)
Power SupplyAC 220 V, 50 Hz, 10 A (DR-15/DR-24) / 16 A (DR-54)
Dimensions (W×D×H)470×350×270 mm (DR-15/DR-24) / 670×460×270 mm (DR-54)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
OriginBeijing, China
ModelMD6 Series
Sample Capacity10 vessels
Microwave SourceSingle Magnetron
Max Temperature200 °C
Max Pressure1500 psi (10.34 MPa)
Cavity Volume45 L
Power Output1200 W
Frequency2450 ±13 MHz
Temperature Control Range0–300 °C
Temp Accuracy±0.5 °C
Pressure Control Range0–6 MPa
Pressure Accuracy±0.01 MPa
Cavity CoatingPFA (DuPont™)
Outer Vessel MaterialReinforced PEEK (10 MPa burst rating)
Inner Vessel MaterialTFM™ (perfluoroalkoxy alkane)
Microwave Leakage≤0.3 mW/cm²
Cooling Airflow3 m³/min
Safety FeaturesDual-stage pressure relief, auto-locking sliding safety door (Patent ZL 200420032536), rupture disc (200/400 psi), real-time Pt100 temperature monitoring, direct-contact pressure transducer, PID-controlled variable-frequency power modulation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
OriginBeijing, China
ModelME6A
Sample Capacity1 vessel
Microwave SourceSingle Magnetron
Max Temperature300 °C
Temperature Control Accuracy±0.5 °C
Pressure Range0–6 MPa
Pressure Control Accuracy±0.01 MPa
Microwave Frequency2450 ±13 MHz
Output Power1200 W (0–100% PID-adjustable)
Cavity Volume45 L
Cavity LiningDupont™ PFA-coated
Outer Vessel MaterialReinforced PEEK (10 MPa burst rating)
Inner Vessel MaterialTFM® (perfluoroalkoxy)
Safety FeaturesDual-stage pressure relief, auto-locking sliding safety door (Patent ZL 200420032536), real-time Pt100 temperature sensing, direct-contact pressure transducer, microwave leakage ≤0.3 mW/cm²
CoolingForced-air exhaust ≥3 m³/min, <20 min cooldown to safe opening temperature
Stirring360° reversible turntable + electromagnetic/mechanical dual-mode stirring (0–5000 rpm)
Control SystemLaptop-based A-type software platform with real-time T/P curve logging, unlimited method storage, and GLP-compliant audit trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
OriginBeijing, China
ModelDR-6G
Digestion TypeGraphite-block Electric Heating
Automation LevelSemi-Automatic
Digestion Positions6 or 8
Max Temperature260 °C
Temperature Accuracy±1.0 °C
Heating MechanismElectric heating plate + graphite thermal conduction block + infrared auxiliary heating
Surface CoatingPTFE (Teflon®)-coated graphite
Rated Power1200 W (DR-6G)
Input VoltageAC 220 V, 16 A
Dimensions (L×W×H)470×350×270 mm (DR-6G)
Sample Vessel Capacity100 mL × 6 or × 8
Pressure Vessel CompatibilityDual-layer sealed reaction vessels rated to 10 MPa
ComplianceMeets GB/T 150 (China National Standard for Pressure Vessels)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
OriginBeijing, China
ModelMP6A
Microwave Frequency2450 ± 13 MHz
Output Power1200 W (0–100% PID-controlled)
Cavity Volume45 L
Max Temperature260 °C
Max Pressure1500 psi (10.34 MPa)
Sample Capacity10 vessels per run
MagnetronSingle
Cavity LiningPFA-coated (DuPont™), acid-resistant and high-temperature stable
Outer Vessel MaterialPEEK (10 MPa burst rating)
Inner Vessel MaterialTFM® (perfluoroalkoxy alkane, chemically inert)
Temperature Control Accuracy±0.5 °C
Pressure Control Accuracy±0.05 MPa
Cooling Airflow3 m³/min, achieving safe venting temperature within 20 min
Door SafetyPatented lateral-release door with dual-stage explosion protection (Patent No. ZL 200420032536)
Microwave Leakage≤0.3 mW/cm² (IEC 61000-4-3 compliant, well below 5 mW/cm² national limit)
Stirring360° bidirectional rotating turntable + optional electromagnetic/mechanical stirring (0–5000 rpm)
Reaction Vessel Options10–1500 mL
ComplianceDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
ModelMD8
OriginBeijing, China
CategoryMicrowave Digestion Instrument
Cavity Volume53 L (316L stainless steel, dual-sided 6-layer PFA coating)
Sample Capacity20 samples per batch (switchable 12/20-position rotor)
Microwave SourceDual magnetron (2450 ±13 MHz), max output power 2400 W
Max Operating Temperature230 °C
Max Rated Pressure6 MPa (870 psi)
Max Burst Pressure10 MPa (1450 psi)
Temperature ControlPT100 platinum resistance sensor, range 0–300 °C, accuracy ±0.1 °C
Pressure ControlHigh-precision pressure transducer, range 0–10 MPa, accuracy ±0.01 MPa
SafetyHorizontal sliding door pressure-release mechanism (Patent ZL200420032536), dual-stage explosion protection, burst disc–based directional venting
Cooling & VentilationCorrosion-resistant variable-frequency centrifugal fan, airflow 5.8 m³/min
Microwave Leakage≤0.3 mW/cm² (IEC 61000-4-3 compliant)
Control SystemClosed-loop PID with real-time frequency modulation
Interface10″ industrial-grade capacitive touchscreen, USB 2.0 port, SD card slot
SoftwareMDUI-P platform with built-in method library, GLP-compliant audit trail, auto-diagnostic routines, and adaptive cooling/fume extraction logic
Power Supply220 V, 50/60 Hz, 16 A, rated input 3600 W
Dimensions (W×D×H)650 × 675 × 650 mm
Net Weight80 kg
Digestion VesselFrame-type high-pressure rotor
operating temp/pressure230 °C / 6 MPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
OriginBeijing, China
ModelMP Series
Microwave Frequency2450 ± 13 MHz
Output Power1200 W (0–100% PID-controlled)
Cavity Volume45 L
Max Temperature260 °C
Max Pressure1500 psi (10.34 MPa)
Sample Capacity10 vessels per run
MagnetronSingle
Cavity CoatingPFA (DuPont™)
Outer Vessel MaterialPEEK (10 MPa rating)
Inner Vessel MaterialTFM™ (perfluoroalkoxy alkane)
Temperature Control Accuracy±0.5 °C (Pt100 sensor)
Pressure Control Accuracy±0.01 MPa (direct-contact transducer)
Microwave Leakage≤0.3 mW/cm²
Cooling Airflow3 m³/min
Safety FeaturesDual-stage pressure relief membrane, self-locking sliding safety door (Patent ZL 200420032536), real-time temperature/pressure dual monitoring, over-pressure/over-temperature cut-off, cavity interlock, and fail-safe power shutdown
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
OriginBeijing, China
ModelMP6C
Microwave Frequency2450 ± 13 MHz
Output Power1200 W (0–100% PID-controlled)
Cavity Volume45 L
Max Temperature260 °C
Max Pressure1500 psi (10.34 MPa)
Sample Capacity10 vessels per run
Microwave SourceSingle Magnetron
Cavity LiningPFA-coated (DuPont™)
Outer Vessel MaterialReinforced PEEK (10 MPa burst rating)
Inner Vessel MaterialTFM® (perfluoroalkoxy alkane)
Temperature ControlPt100 RTD, ±0.5 °C accuracy (0–300 °C range)
Pressure ControlDirect-contact sensor, 0.01 MPa resolution
Safety FeaturesSix-layer protection including dual-stage pressure relief, auto-shutoff at overpressure, patented sliding-lock safety door (ZL 200420032536), microwave leakage ≤0.3 mW/cm²
CoolingForced-air exhaust, 3 m³/min, <20 min to safe opening temperature
Stirring360° bidirectional rotating carousel + optional electromagnetic/mechanical stirring (0–5000 rpm)
Control SystemEmbedded microcontroller (MP6C variant) with 15 pre-programmable methods (8-step ramping), real-time T/P curve display, method storage
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
OriginBeijing, China
ModelDR-15N
Digestion Capacity15 × 100 mL
Block MaterialHigh-Purity Graphite with 6-Layer PTFE Coating
Heating PrincipleInfrared Radiant Heating
Temperature RangeAmbient to 260 °C
Temperature ControlPID Digital Controller
Temperature Uniformity≤1 °C at 150 °C (inter-hole)
Temperature Accuracy±1.0 °C
Programmable StepsSingle-step or Optional 30-Step Ramp/Soak Profile
Max Power Consumption1200 W
Dimensions (W×D×H)650 × 430 × 220 mm
Electrical SupplyAC 220 V / 50 Hz / 10 A
Digestion Well DimensionsΦ42 × 50 mm (customizable)
ComplianceEPA Method 3050B, 3051A, 3052
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
ModelMD Series
OriginBeijing, China
Microwave Frequency2450 ±13 MHz
Output Power1200 W
Power Control0–100% PID Automatic Continuous Adjustment
Cavity Volume45 L
Dimensions (W×D×H)490 × 610 × 610 mm
Net Weight48 kg
Temperature Range0–300 °C
Temperature Accuracy±0.5 °C
Pressure Range0–6 MPa
Pressure Accuracy±0.05 MPa
Microwave Leakage≤0.3 mW/cm²
Cavity CoatingDupont PFA
Outer Vessel MaterialPEEK (10 MPa burst rating)
Inner Vessel MaterialTFM (chemically resistant, up to 300 °C)
Cooling Airflow3 m³/min (cooling to safe opening temperature within 20 min)
Door MechanismPatented lateral-release safety door with dual-stage explosion protection (Patent No.: ZL 200420032536)
Stirring360° reversible turntable
Reaction Vessel Capacity10–1500 mL (standard 500 mL)
Control OptionsA-type (laptop-based software with real-time T/P curve monitoring, unlimited method storage)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
OriginBeijing, China
ModelDR Series
Digestion Positions15 / 24 / 40 / 54 / 77
Temperature RangeAmbient to 260 °C
Temperature Control Accuracy±1.0 °C
Heating PrincipleInfrared Radiant Heating
Heating Block MaterialHigh-Purity Graphite with PTFE Coating
Control SystemPID Digital Controller (30-Step Programmable Ramp/Soak)
Max Power1200 W (DR-15/DR-24), 3000 W (DR-54)
Sample Vessel CompatibilityStandard digestion tubes (e.g., 50 mL or 100 mL borosilicate or quartz)
ComplianceDesigned for GLP-compliant sample preparation workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHW Series
Instrument TypeGraphite-Based Infrared Digestion System
Heating MaterialHigh-Temperature PTFE-Coated Graphite
Max Power2500 W (HW-15), 3500 W (HW-24/HW-40/HW-54)
Control MethodPID Digital Display
Temperature Program Steps30
Max Operating Temperature460 °C
Temperature Accuracy±1.0 °C
Sample CapacityHW-15: 15 × 100 mL
HW-2424 × 50 mL
HW-4040 × 100 mL
HW-5454 × 50 mL
Digestion Well DimensionsHW-15: Φ42 × 40 mm
HW-24Φ26 × 40 mm
HW-40Φ42 × 40 mm
HW-54Φ23 × 50 mm
Power SupplyAC 220 V / 50 Hz, 16 A
Unit Dimensions (W×D×H)HW-15: 470 × 350 × 270 mm
HW-24/HW-40/HW-54670 × 460 × 270 mm
Compatible VesselsStandard borosilicate glass digestion tubes (custom diameters supported)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
OriginBeijing, China
ModelMD6
Sample Capacity6–10 vessels
Microwave SourceDual-Magnetron
Max Temperature260 °C
Max Pressure2200 psi
Cavity LiningPFA-coated (DuPont™)
Temperature Control Range0–300 °C
Temp Accuracy±0.5 °C
Pressure Control Range0–6 MPa
Pressure Accuracy±0.01 MPa
Microwave Leakage≤0.3 mW/cm²
Output Power1200 W (0–100% PID-adjustable)
Cavity Volume45 L
Dimensions (W×D×H)490×610×610 mm
Weight48 kg
Cooling Airflow3 m³/min
SafetySix-layer protection including dual-stage pressure relief, auto-locking blast-resistant door (Patent ZL 200420032536), rupture disc, and real-time Pt100/pressure dual-sensor feedback
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
OriginBeijing, China
ModelGraphite Digestion Assistant
Instrument TypeGraphite Digestion Accessory
Sample Vessel CompatibilityUniversal (Customizable for Domestic & Imported Graphite Block Digesters)
MaterialHigh-Purity Isostatically Pressed Fine-Grain Graphite with DuPont™ Teflon® Coating
Surface TreatmentHigh-Pressure Air Atomization Spray Process
Thermal StabilityUp to 330 °C
Corrosion ResistanceCertified for prolonged exposure to concentrated HNO₃, HCl, HF, H₂SO₄, and aqua regia
Included AccessoriesPortable Carrying Case with Phenolic Foam Liner, Non-Contact Infrared Thermometer (–50 °C to 330 °C), Telescopic Acid-Resistant Inspection Mirror (16–52 cm extension, 360° axial/radial rotation), Stainless Steel Non-Magnetic Sample Handling Tools
Standard Configuration15 Custom-Fit Conversion Components per Set
CustomizationAvailable for non-standard vessel geometries and OEM integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
ModelMD6
OriginBeijing, China
Microwave Frequency2450 ± 13 MHz
Output Power1200 W
Power Control0–100% PID automatic continuous adjustment
Cavity Volume45 L
Dimensions (W×D×H)490 × 610 × 610 mm
Net Weight48 kg
Temperature Range0–300 °C
Temperature Accuracy±0.5 °C
Pressure Range0–6 MPa (900 psi)
Pressure Accuracy±0.01 MPa
Cavity CoatingPFA (DuPont™)
Microwave Leakage≤0.3 mW/cm²
Safety FeaturesDual-stage explosion-proof door (Patent ZL 200420032536), rupture disk pressure relief, Pt100 direct-contact temperature sensing, real-time dual-parameter (T&P) monitoring
Vessel ConfigurationPEEK outer vessel (10 MPa rating), TFM inner vessel (chemically inert, 300 °C stable)
Rotation360° reversible turntable with magnetic & mechanical stirring (0–5000 rpm)
Sample CapacityUp to 10 vessels per run (standard: 4 or 6 vessels
volume range10–1500 mL)
Control OptionsA-type laptop-based software interface (unlimited method storage, real-time T&P curve logging) or C-type microcontroller (15 pre-programmed methods, 8-step ramping)
Ventilation3 m³/min forced-air cooling, <20 min cooldown to safe opening temperature
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
OriginBeijing, China
ModelMD6C
Sample Capacity10 vessels
Microwave SourceSingle Magnetron
Max Temperature200 °C
Max Pressure3.0 MPa
Cavity ClassificationIndustrial-Grade
Control SystemMicroprocessor-Based PID with Digital Display
Temperature Accuracy±0.5 °C
Pressure Accuracy±0.01 MPa
Cavity LiningPFA-coated (DuPont™)
External Cooling Airflow3 m³/min
Microwave Leakage≤0.3 mW/cm²
Safety FeaturesDual-stage pressure relief, auto-locking blast-resistant door (Patent ZL 200420032536), rupture disc protection (200/400 psi), integrated Pt100 temperature sensor & direct-contact pressure transducer
Vessel MaterialOuter — PEEK (10 MPa rating)
Power InputAC 220 V / 50 Hz / 10 A
Output Power1200 W (0–100% PID-adjustable)
Cavity Volume45 L
Dimensions (W×D×H)490 × 610 × 610 mm
Weight48 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
ModelFS Series
TypeGraphite Block Digestion Instrument
Heating Block MaterialHigh-Purity Graphite with PTFE Coating
Max. Temperature260 °C
Temp. Accuracy±0.2 °C
Heating Power1200 W (FS-I) / 3000 W (FS-II)
Programmable Steps30
Sample Capacity6 × 100 mL (FS-I) / 8 × 100 mL (FS-II)
Pressure Rating of Digestion Vessels10 MPa
ComplianceMeets National Pressure Vessel Standards (China GB/T 150)
Power SupplyAC 220 V, 50 Hz, 10 A (FS-I) / 16 A (FS-II)
Dimensions (W×D×H)470×350×270 mm (FS-I) / 670×460×270 mm (FS-II)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
ModelDR-35
Sample Capacity35 positions
Digestion Well DimensionsØ31 × 50 mm
Heating MethodInfrared-heated graphite block
Heating MaterialHigh-purity graphite with PTFE coating
Effective Heating Area470 × 314 mm
Temperature RangeRT to 260 °C
Temperature Uniformity≤1.0 °C between wells at 150 °C
Control System30-step PID programmable controller
Temperature Accuracy±0.1 °C
Max Power2500 W
Input PowerAC 220 V / 50 Hz / 10 A
Dimensions (W×D×H)770 × 520 × 200 mm
WeightApprox. 48 kg
Optional AccessoriesBorosilicate glass digestion tubes with reflux condensers (35 pcs), PTFE digestion cups (35 pcs), graphite sample racks, custom digestion vessel kits (glass/PTFE/PFA)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
ModelZDD-1 / ZDD-2
Digestion TypeGraphite Block Digestion
Heating MethodConventional (ZDD-1) / Infrared (ZDD-2)
Max. Temperature260 °C (ZDD-1) / 460 °C (ZDD-2)
Temp. Accuracy±1.0 °C
Oscillation Frequency0–300 cycles/min
Oscillation Amplitude10 mm (reciprocating)
Timer Range1–99 h
Power SupplyAC 220 V, 50 Hz, 16 A
Dimensions500 × 360 × 360 mm
Weight Capacity40 kg
Control SystemPID with 30-step programmable ramp/soak
Heating MaterialPTFE-coated graphite (ZDD-1) / High-temp PTFE-coated graphite (ZDD-2)
Motor Power45 W
Bearing TypeImported linear bearing
Surface FinishBrushed stainless steel
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICHEM
OriginBeijing, China
ModelMD6
Microwave Frequency2450 ±13 MHz
Output Power1200 W
Power Control0–100% PID automatic continuous adjustment
Cavity Volume45 L
Dimensions (W×D×H)490 × 610 × 610 mm
Net Weight48 kg
Temperature Range0–300 °C
Temperature Accuracy±0.5 °C
Pressure Range0–6 MPa
Pressure Accuracy±0.01 MPa
Cavity CoatingPFA (DuPont™)
Microwave Leakage≤0.3 mW/cm²
Safety FeaturesDual-stage explosion-proof door (Patent ZL 200420032536), rupture disc pressure relief, Pt100 direct-contact temperature sensing, integrated pressure transducer, interlocked safety door, modular control architecture
Vessel ConfigurationPEEK outer vessel (10 MPa rating), TFM inner vessel (chemically inert, 300 °C stable)
Rotating Turntable360° bidirectional, motor-driven, optical feedback control
StirringElectromagnetic + mechanical dual-mode, 0–5000 rpm adjustable
Max. Simultaneous Samples6 or 10 (configurable)
Ventilation3 m³/min, <20 min cooldown to safe opening temperature
ComplianceMeets GB 4706.21 (China), IEC 61000-4 series EMC standards, and general requirements for laboratory microwave equipment per ISO/IEC 17025 supporting infrastructure