| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | AL204 |
| Readability | 0.1 mg |
| Max Capacity | 210 g |
| Repeatability | 0.1 mg |
| Linearity Error | 0.3 mg |
| Calibration | External 200 g weight |
| Pan Diameter | 90 mm |
| Draft Shield Height | 220 mm |
| Dimensions (W×D×H) | 238 × 335 × 364 mm |
| Interface | RS232 |
| Applications | Simple weighing, percentage weighing, piece counting, dynamic weighing, net/gross/tare operations |
| Compliance | Designed to support GLP/GMP documentation requirements |
| Brand | SHYP |
|---|---|
| Origin | Shanghai, China |
| Model | JA-B |
| Readability | 1 mg |
| Capacity Range | 100 g to 500 g |
| Pan Diameter | 80 mm |
| Dimensions (W×D×H) | 350 × 215 × 340 mm |
| Clear Height Under Pan | 240 mm |
| Interface | RS232C |
| Power Supply | External AC Adapter |
| Compliance | ISO 9001, GLP-compliant design |
| Key Features | Auto-calibration, overload protection, piece counting, percentage weighing, unit conversion, real-time error diagnostics |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.1 mg |
| Repeatability | ≤ ±1 mg |
| Calibration | Internal |
| Pan Size | 90 mm diameter |
| Display | Backlit Low-Temperature LCD |
| Sensor Technology | Monolithic Electromagnetic Force Compensation Sensor |
| Interface | RS-232C standard, USB optional |
| Compliance | ISO/IEC 17025, GLP/GMP-ready, FDA 21 CFR Part 11 compatible (with optional software) |
| Brand | ROCKER |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | Pilot100 |
| Price Range | USD 1,400–2,800 |
| Measurement Principle | Digital Vacuum Gauge (Capacitance Manometer-Based) |
| Pressure Range | 0–1100 mbar (absolute) |
| Vacuum Port | ID 8 mm |
| Input Power | DC 24 V, 1 A |
| Resolution | 1 digit |
| Pressure Units | mbar, hPa, torr |
| Display | 7" capacitive touch screen |
| Accuracy | ±2 mbar (at stabilized ambient temperature, post-calibration) |
| Adjustable Setpoint Range | 0–1013 mbar (abs) / 0–760 mmHg |
| Housing Material | Flame-retardant engineering plastic (UL94 V-0) |
| Bleed Valve | Integrated solenoid-controlled air inlet valve |
| Self-Cleaning Function | Yes (automated vent/bleed cycle to prevent condensate accumulation) |
| Power Consumption | 15 W |
| Compatible Tubing ID | 8–10 mm |
| Safety Features | Overpressure protection, real-time error logging, audible/visual fault alerts |
| Dimensions (L×W×H) | 210 × 196 × 184 mm |
| Weight | 2.2 kg |
| Certifications | CE, RoHS, IP40 |
| Boiling Point Detection | Yes (dynamic vapor pressure tracking via pressure slope analysis) |
| Brand | SHYP |
|---|---|
| Origin | Shanghai, China |
| Model | FA/JA-C Series |
| Readability | 0.1 mg (FA-series) / 1 mg (JA-series) |
| Capacity | 60–300 g |
| Pan Size | φ90 mm |
| Dimensions (W×D×H) | 350×215×340 mm |
| Working Height | 240 mm |
| Calibration | Fully Automatic Internal Calibration (Motorized砝码 Mechanism) |
| Interface | RS232C |
| Display | Backlit LCD |
| Compliance | Designed for GLP/GMP environments with audit-ready calibration logs |
| Software Compatibility | Supports standard balance data capture via RS232 (ASCII protocol), compatible with LabWare, Empower, and custom LIMS integrations |