- All
- Favorite
- Popular
- Most rated
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | MINIC-100I |
| Temperature Range | −10 °C to 100 °C |
| Temperature Accuracy | ≤ ±0.5 °C |
| Temperature Uniformity (at 40 °C Δ) | ±0.3 °C |
| Block Stability (at 100 °C) | ≤ ±0.5 °C |
| Display Resolution | 0.1 °C |
| Heating Time (20 °C → 100 °C) | ≤ 15 min |
| Cooling Time (RT → RT−20 °C) | ≤ 30 min |
| Max Power | 120 W |
| Weight | ≤ 1.4 kg |
| Input Voltage | 24 V DC |
| Heat Lid | Yes |
| Programmable Timer | 0–999 min |
| Replaceable Blocks | MINI-A (40×0.2 mL), MINI-B (24×0.5 mL), MINI-C (15×1.5 mL), MINI-D (15×2.0 mL), MINI-E (8–12.5×12.5 mm cuvettes), MINI-F (4×15 mL), MINI-G (2×50 mL) |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JYH-100 |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Accuracy | ≤ ±0.3°C |
| Heating Time | ≤12 min (25°C to 100°C) |
| Display Resolution | 0.1°C |
| Max Timer Setting | 99 h 59 min |
| Power Consumption | 150 W |
| Dimensions (W×D×H) | 260 × 195 × 150 mm |
| Net Weight | 2.5 kg |
| Module Options | A–K (including 96-well PCR plates, 0.2–50 mL tube configurations) |
| Brand | MENTS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | JY200-2 |
| Price | USD 630 (FOB) |
| Temperature Range | Ambient +5°C to 160°C |
| Temperature Accuracy | ±0.5°C (@40°C), ±1.0°C (@120°C) |
| Temperature Uniformity | ±0.5°C |
| Heating Time | ≤15 min (25°C → 160°C) |
| Display Resolution | 0.1°C |
| Timer Range | 1–99 h 59 min |
| Power | 500 W |
| Input Voltage | AC 220 V |
| Dimensions (W×D×H) | 260 × 220 × 100 mm |
| Net Weight | 7 kg |
| Aluminum Block Material | High-Purity Anodized Aluminum |
| Over-Temperature Protection | Integrated Thermal Cut-Off |
| Calibration Offset Adjustment | User-Accessible via Keypad |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | K30 |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Accuracy | ≤ ±0.5°C |
| Heating Time | ≤15 min (20°C to 100°C) |
| Display Resolution | 0.1°C |
| Block Uniformity | ≤ ±0.5°C |
| Max Power | 150 W |
| Max Set Time | 9999 min |
| Dimensions (W×D×H) | 176 × 156 × 121 mm |
| Net Weight | 1.5 kg |
| Brand | MENTS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | JY200-4 |
| Temperature Range | Ambient +5°C to 130°C |
| Temperature Accuracy | ±0.5°C (@40°C), ±1.0°C (@120°C) |
| Heating Time | ≤20 min (25°C → 130°C) |
| Dimensions (L×W×H) | 360 × 220 × 100 mm |
| Net Weight | 3 kg |
| Power Rating | 600 W |
| Input Voltage | AC 220 V |
| Display Resolution | 0.1°C |
| Temperature Uniformity | ±0.5°C |
| Timer Range | 1–99 h 59 min |
| Block Capacity | 4 interchangeable blocks |
| Safety Features | Over-temperature protection, auto-fault detection & alarm, user-accessible temperature offset calibration |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | MK100-4A |
| Temperature Range | Ambient +5°C to 80°C |
| Temperature Accuracy | ≤ ±0.5°C |
| Heating Time | ≤20 min (from ambient to 80°C) |
| Timer Range | 1 min to 99 h 59 min |
| Display Resolution | 0.1°C |
| Temperature Uniformity Across Plate | ≤ ±0.5°C |
| Capacity | 4 standard microplates (e.g., 96-well, 384-well, deep-well, cell culture plates) |
| Power Consumption | 120 W |
| Dimensions | 280 × 270 × 140 mm |
| Weight | 4.5 kg |
| Brand | JIAYUAN |
|---|---|
| Model | MK100-2A |
| Temperature Range | Ambient +5°C to 80°C |
| Temperature Accuracy | ≤ ±0.5°C |
| Heating Time | ≤20 min (from ambient to 80°C) |
| Timer Range | 1 min to 99 h 59 min |
| Display Resolution | 0.1°C |
| Temperature Uniformity Across Plate | ≤ ±0.5°C |
| Capacity | 2 standard microplates (e.g., 96-well, 384-well, deep-well, or cell culture plates) |
| Power Consumption | 120 W |
| Dimensions (W×D×H) | 280 × 270 × 140 mm |
| Net Weight | 4.0 kg |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY200-1 |
| Temperature Range | Ambient +5°C to 160°C |
| Temperature Accuracy | ±0.5°C (@40°C), ±1.0°C (@120°C) |
| Temperature Uniformity | ±0.5°C |
| Display Resolution | 0.1°C |
| Heating Time | ≤15 min (25°C to 160°C) |
| Timer Range | 1–99 h 59 min |
| Power | 300 W |
| Voltage | AC 220 V |
| Dimensions | 260 × 220 × 100 mm |
| Block Capacity | Single interchangeable block |
| Compliance | CE-marked design principles, compatible with GLP-compliant lab workflows |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | MINIB-100I |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Accuracy | ≤ ±0.5°C at 100°C |
| Temperature Uniformity | ≤ ±0.3°C across block surface |
| Ramp Time | ≤15 min (20°C → 100°C) |
| Power Supply | 24 V DC |
| Max Power Consumption | 60 W |
| Weight | ≤1 kg |
| Programmable Timer | 0–999 min |
| Display Resolution | 0.1°C |
| Over-Temperature Protection | Integrated |
| Cooling Method | Passive air convection with integrated fan |
| Module Interchangeability | Yes (MINI-A through MINI-G standard configurations) |
| Brand | MENTS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MINIB-100 |
| Price | USD 360 (FOB) |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Accuracy | ≤ ±0.3°C |
| Heating Time | ≤20 min (40°C to 100°C) |
| External Dimensions | 145 × 113 × 110 mm |
| Net Weight | 0.5 kg |
| Power Rating | 40 W |
| Input Voltage | AC 100–240 V, 50–60 Hz |
| Display Resolution | 0.1°C |
| Temperature Uniformity Across Block | ≤ ±0.3°C |
| Timer Range | 1 sec to 99 h 59 min or continuous (∞) |
| Safety Certifications | CE-compliant |
| Module Compatibility | Interchangeable heated blocks for 0.2 mL, 0.5 mL, 1.5 mL, 2.0 mL tubes, cuvettes (12.5 × 12.5 mm), 15 mL and 50 mL centrifuge tubes |
| Brand | JIAYUAN |
|---|---|
| Model | DKT200-2A |
| Temperature Range | Ambient +5°C to 150°C |
| Temperature Accuracy | ≤ ±0.5°C (40–100°C), ≤ ±1.0°C (100–150°C) |
| Temperature Uniformity | ≤ ±0.5°C across block surface |
| Max Block ΔT at 40°C differential | 0.3°C |
| Heating Time | ≤30 min (20°C → 150°C) |
| Display Resolution | 0.1°C |
| Timer Range | 1 min – 99 h 59 min |
| Max Power | 400 W |
| Dimensions (W×D×H) | 260 × 290 × 95 mm |
| Compatible Modules | DT01–DT19 (including 0.2 mL × 96, 1.5/2.0 mL × 24, 13–28 mm tube formats, 96-well PCR/ELISA plates, and custom blocks) |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | MINIB-100F |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Accuracy | ≤ ±0.5°C at 100°C |
| Temperature Uniformity | ≤ ±0.3°C across block surface (at 40°C delta) |
| Heating Time | ≤15 min (20°C to 100°C) |
| Display Resolution | 0.1°C |
| Timer Range | 0–999 min |
| Power Input | 24 V DC |
| Max Power Consumption | 60 W |
| Weight | ≤1 kg |
| Cooling Method | Integrated axial fan |
| Hot Lid | Not included |
| Module Compatibility | MINI-A to MINI-G interchangeable blocks |
| Brand | MENTS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LCC-100 |
| Temperature Range | –10 °C to 100 °C |
| Temperature Accuracy | ≤ ±0.3 °C |
| Heating Time | ≤ 10 min (25 °C → 100 °C) |
| Cooling Time | ≤ 30 min (ambient → ambient –30 °C, at ≤26 °C ambient) |
| Dimensions (W×D×H) | 260 × 195 × 150 mm |
| Net Weight | 4.5 kg |
| Power Consumption | 150 W |
| Display Resolution | 0.1 °C |
| Timer Range | 1 min – 99 h 59 min |
| Module Compatibility | JYC-100 Series (A–J standard configurations |
| Brand | MENTS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MINIC-100 |
| Price | ¥5,700 |
| Temperature Range | −10 °C to 100 °C |
| Temperature Accuracy | ≤ ±0.5 °C |
| Heating Time | ≤15 min (20 °C → 100 °C) |
| External Dimensions | 40 cm (L × W × H unspecified |
| Net Weight | 4.5 kg |
| Cooling Time | ≤30 min (ambient −20 °C drop) |
| Temperature Uniformity | ≤ ±0.3 °C (at 40 °C ΔT across block) |
| Display Resolution | 0.1 °C |
| Max Timer Duration | 999 min |
| Max Power Consumption | 120 W |
| Input Voltage | 24 V DC |
| Safety Features | Over-temperature protection, self-diagnostic error detection with audible alarm |
| Block Modules | MINI-A (40×0.2 mL), MINI-B (24×0.5 mL), MINI-C (15×1.5 mL), MINI-D (15×2.0 mL), MINI-E (8–12.5 mm cuvette), MINI-F (4×15 mL), MINI-G (2×50 mL), MINI-H (customizable) |
| Heat Cover | Not included |
| Brand | JIAYUAN |
|---|---|
| Origin | Beijing, China |
| Model | MK-10 |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Accuracy | ≤ ±0.5°C |
| Temperature Uniformity (at 40°C) | ≤ ±0.3°C |
| Block Temperature Stability (at 100°C) | ≤ ±0.5°C |
| Heating Time | ≤15 min (20°C → 100°C) |
| Display Resolution | 0.1°C |
| Max Timer Setting | 99 h 59 min |
| Power Consumption | 150 W |
| Net Weight | 2.2 kg |
| Dimensions (W×D×H) | 270 × 190 × 170 mm |
| Interchangeable Block Options | A–N (including 96-well PCR plates, 0.2–50 mL tube formats, and custom blocks) |
| Brand | MENTS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MK-20 |
| Price | USD 1,150 (FOB) |
| Temperature Range | −10 °C to 100 °C |
| Temperature Accuracy | ≤ ±0.5 °C |
| Heating Time | ≤ 15 min (20 °C → 100 °C) |
| Cooling Time | ≤ 30 min (ΔT = −30 °C, ambient ≤ 26 °C) |
| Temperature Uniformity | ≤ ±0.3 °C @ 40 °C |
| Block Temperature Stability @ 100 °C | ≤ ±0.5 °C |
| Display Resolution | 0.1 °C |
| Max Timer Setting | 99 h 59 min |
| Power Consumption | 150 W |
| Dimensions (W×D×H) | 270 × 190 × 170 mm |
| Net Weight | 2.2 kg |
| Compatible Modules | A–N (including 96-well PCR plates, 0.2–50 mL tube formats, and custom square wells) |