- All
- Favorite
- Popular
- Most rated
| Brand | Sigma |
|---|---|
| Origin | Germany |
| Model | Sigma1-14 |
| Maximum Capacity | 24 × 2.2 mL |
| Maximum Speed | 14,800 rpm |
| Dimensions (H×W×D) | 176 × 226 × 212 mm |
| Power Consumption | 95 W |
| Noise Level | < 60 dBA |
| Acceleration/Deceleration Profiles | 2 programmable curves |
| Time Control | 0–99 min 59 s / Continuous / Short-spin mode |
| RCF Range | 2 × g to 16,163 × g |
| Motor Type | Brushless DC |
| EMC Compliance | EN 55011 Class B |
| Interference Immunity | EN 61326 |
| Weight (without rotor) | 5.4 kg |
| Max Kinetic Energy | 1721 N·m |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | GL-21C |
| Max Speed | 21000 rpm |
| Max RCF | 45200 ×g |
| Angular Rotor Capacity | 500 mL × 6 |
| Timer Range | 0–60 min |
| Power Supply | 220 V, 50 Hz, 1900 VA |
| Dimensions (L×W×H) | 640 × 690 × 905 mm |
| Weight | 180 kg |
| Brand | SCILOGEX |
|---|---|
| Origin | USA |
| Model | D1008 |
| Max Speed | 7000 rpm |
| RCF | 2000 × g |
| Capacity | 8 × 0.5/1.5/2.0 mL tubes or 16 × 0.2 mL PCR tubes + 2 × 0.2 mL PCR strips |
| Motor | Brushless DC motor |
| Power Input | AC 100–240 V, 50/60 Hz |
| Noise Level | ≤45 dB(A) |
| Dimensions (W×D×H) | 170 × 160 × 122 mm |
| Weight | 0.5 kg |
| Safety | Dual interlock lid system, automatic rotor stop on lid opening, IEC 61010-1 & IEC 61010-2-020 compliant |
| Included Rotors | A08-2 (8-position universal tube rotor), PCR rotor (16×0.2 mL + 2×8-strip), optional microscope slide rotor available |
| Brand | SCILOGEX |
|---|---|
| Origin | USA |
| Model | D2012 |
| Maximum RCF | 15100 ×g |
| Maximum Speed | 15000 rpm |
| Capacity | 12 × 2 mL tubes |
| Timer Range | 30 s to 99 min + HOLD mode |
| Motor | Brushless DC motor |
| Noise Level | ≤56 dB(A) |
| Dimensions (L×D×H) | 255 × 245 × 140 mm |
| Weight | 6 kg |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Safety Features | Lid interlock, overspeed protection, overtemperature detection, real-time diagnostics |
| Rotor Material | Anodized aerospace-grade aluminum alloy |
| Rotor Sterilization | Autoclavable (≥100 cycles, 121°C, 2 bar) |
| Temperature Rise at Max Speed | ≤8°C after 60 min operation |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Anting Scientific Instrument Factory |
| Model | TDL-5C |
| Max Speed | 5000 rpm |
| Max RCF | 4500 × g |
| Drive Type | Frequency-Controlled Brushless Motor |
| Control System | Microprocessor-Based Digital Control |
| Rotor Configurations | Horizontal Fixed-Angle & Swinging-Bucket Options |
| Capacity Options | 250 mL × 4, 50 mL × 8, 10 mL × 36, 15 mL × 16, 7 mL × 36, 5 mL × 36, 6 mL × 96 (RIA), 192-well Microtiter Plate (Mold Assay) |
| Safety Certification | CE-compliant design per IEC 61010-1, IP20 enclosure rating |
| Operating Ambient | 5–40 °C, ≤80% RH non-condensing |