Aolong
Filter
Showing 1–30 of 102 results
| Brand | AOLONG |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AL-CT1020 |
| X-ray Tube Voltage | 20–225 kV |
| Target Type | Reflection Anode |
| Max. Tube Power | 320 W |
| Max. Target Power | 280 W |
| Source-to-Object Minimum Distance | 4 mm |
| Spatial Resolution (JIMA) | 2 µm |
| Number of Axes | 5 |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | 31-040A |
| Price | Upon Request |
| Detection Radiation | X-ray & Gamma (γ) |
| Dose Rate Range | 0.01 µSv/h – 10 mSv/h |
| Cumulative Dose Range | 0.1 pSv – 1 Sv |
| Energy Response Range | 30 keV – 3 MeV |
| Dose Rate Accuracy | ±30% (typical, per IEC 61526 ed.3) |
| Operating Temperature | −20 °C to +50 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Power Input | DC 5 V / 200 mA |
| Ingress Protection | IP65 |
| Battery Life | >72 h (background radiation environment, no external power) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | 32-150B |
| Price | Upon Request |
| Detection Radiation | X-ray and γ-ray |
| Dose Rate Range | 0.01 µSv/h to 10 mSv/h |
| Cumulative Dose Range | 0.1 µSv to 1 Sv |
| Energy Response Range | 30 keV to 3 MeV |
| Dose Rate Accuracy | < ±30% |
| Operating Temperature | −20 °C to +50 °C |
| Relative Humidity | < 90% (non-condensing) |
| Power Input | DC 5 V |
| Dimensions | 110 mm × 135 mm × 47 mm |
| Weight | < 500 g |
| Display | Large-color high-brightness LED |
| Alarm | Audible and visual alarm with user-adjustable threshold |
| Mounting | Wall-mountable or benchtop placement |
| Connectivity | Ethernet port, USB interface, optional Wi-Fi antenna |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Model | AL-27min |
| X-ray Tube | Metal-ceramic Cu anode (2.4 kW), focal spot 1×10 mm |
| Generator Power Options | 600 W (40 kV / 15 mA) or 1200 W (40 kV / 30 mA) |
| Voltage/Current Stability | ±0.005% |
| Goniometer Configuration | Horizontal θs–θd geometry, radius 150 mm |
| Angular Range (θs/θd coupled) | –3° to 150° |
| Minimum Step Size | 0.0001° |
| Angular Reproducibility | ±0.0005° |
| Maximum Goniometer Speed | 1500°/min |
| Detector Options | Sealed proportional counter or high-speed 1D semiconductor array |
| Energy Resolution | <25% (FWHM at Cu Kα) |
| Maximum Linear Count Rate | ≥5×10⁵ cps (proportional), ≥9×10⁷ cps (1D semiconductor) |
| Sample Changer Capacity | Up to 6 samples per loading |
| Radiation Shielding | Lead + lead-glass interlocked shutter |
| Overall Instrument Stability | ≤0.1% (RSD over 8 h) |
| Dimensions (W×D×H) | 600×410×670 mm |
| Operating System | Windows 7 (dedicated Dell commercial laptop) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Simultaneous WDXRF Spectrometer |
| X-ray Tube Power | 400 W (50 kV / 8 mA) |
| Analyzed Elements | Na (11) to U (92), pre-configured for Ca, Fe, Si, Al, Na, Mg, S, K, Cl, P |
| Vacuum Level | < 7 Pa |
| Sample Diameter | 40 mm |
| Analysis Area | up to 35 mm |
| Sample Rotation Speed | 30 rpm |
| Stability (24 h) | ≤ 2% |
| Energy Resolution (Detector) | ≤ 40% |
| Counting Linearity | ≤ 1% |
| Measurement Time per Sample (incl. vacuum & exchange) | 2–5 min |
| Detector Types | Flow-proportional counter, sealed proportional counter, scintillation counter |
| Pulse Height Analyzer | 12-channel, 2048-channel MCA |
| Flow Gas Control Precision | ±0.01 kPa |
| Constant-Temperature Chamber Accuracy | ±0.1 °C |
| Power Supply | 220 V AC, 2 kVA stabilized |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | AL-CT-1000 |
| X-ray Energy Range | 20–450 kV |
| Steel Penetration Capacity | 50 mm (A3 steel) |
| Spatial Resolution | 3.0 LP/mm |
| Density Resolution | 0.5% |
| Field of View | 43 × 43 cm |
| Dimensional Measurement Accuracy | ±1 µm |
| Density Measurement Accuracy | ±1 µg/cm³ |
| Detection Modes | Cone-beam CT, Helical CT, Planar CT, Limited-angle CT, Dual-Energy Spectral CT |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | AL-CT1010 |
| X-ray Source | Reflected-anode microfocus tube |
| Max. Tube Voltage | 225 kV |
| Focal Spot Size | ≤3 µm |
| Max. Anode Power | 350 W |
| Max. Target Power | 300 W |
| Spatial Resolution (Detail Detectability) | ≤2 µm |
| Detector | Amorphous silicon flat-panel detector |
| Pixel Count | 1536 × 1920 |
| Pixel Pitch | 127 µm |
| Active Area | 250 mm × 200 mm |
| Gray Scale Resolution | 16-bit |
| Limiting Resolution | 3.94 lp/mm |
| Cooling Method | Air-cooled |
| Filament Design | Plug-and-play, user-replaceable |
| X-ray Tube Lifetime | >8 years |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | AL-DR-120 |
| Detector Type | Flat-Panel Detector |
| Power Supply | Integrated Rechargeable Battery (6-hour continuous operation) |
| Connectivity | Fully Wireless Remote Control |
| Form Factor | Compact, Lightweight Portable Design |
| Imaging Mode | Real-Time Digital Radiography |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | AL-DR-270 |
| X-ray Tube Voltage | 270 kV |
| Penetration Capability | 13 mm steel equivalent |
| Detector Type | Amorphous Silicon Flat Panel Detector |
| Effective Imaging Area | 350 × 430 mm |
| Pixel Pitch | 140 µm |
| Spatial Resolution | 3.2 lp/mm |
| A/D Conversion | 16-bit |
| Image Acquisition Time | 1 s (wired), 2.5 s (wireless) |
| Focal Spot Size | 3 mm |
| Pulse Width | 50 ns |
| Pulse Rate | 15 Hz |
| Output Dose | 2.6–4.0 mR/pulse (measured at 30.5 cm / 12 in from source) |
| Dimensional Measurement Accuracy | ±1 mm |
| Radiation Safety Compliance | Meets IEC 61331-1 and GBZ 138–2019 requirements for portable pulsed X-ray devices |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | AL-DR-270A |
| Price Range | USD 140,000 – 280,000 |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | AL-DR-300B |
| Price Range | USD 140,000 – 280,000 |
| Max. X-ray Energy | 350 kV |
| Tube Current | 5 mA |
| Focal Spot Size | 2.0 mm |
| Beam Divergence Angle | 40° |
| Sensitivity | ≤1.5% |
| Detector Type | Amorphous Silicon (a-Si), Custom-Optimized for Variable-Frequency X-ray Source |
| Active Imaging Area | 35 × 21 cm |
| Pixel Pitch | 140 µm |
| Spatial Resolution | 3.2 LP/mm |
| A/D Conversion | 16-bit |
| Image Acquisition Time | 1 s (wired), 2.5 s (wireless) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | AL-DR-300C |
| Configuration | Portable |
| Beam Directionality | Directional |
| Focal Spot Size | 2.5 mm |
| Radiation Angle | 40° + 5° (Total Coverage: 45°) |
| Maximum Penetration | 60 mm Fe-equivalent |
| Max. Tube Voltage | 320 kV |
| Tube Current | 5 mA |
| Detector Type | Amorphous Silicon (a-Si) Flat Panel Detector (Custom-optimized for Variable-Frequency X-ray Source) |
| Active Detector Area | 13 cm × 13 cm |
| Pixel Pitch | 85 µm |
| Spatial Resolution | 4 LP/mm |
| A/D Conversion | 16-bit |
| Sensitivity | ≤1.5% (EN 13297:2011 compliant) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | AL-DR-80 |
| Price Range | USD 140,000 – 280,000 |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Producer |
| Country of Origin | China |
| Model | AL-GB-1306 |
| Voltage Range | 30–130 kV |
| Current Range | 0.1–0.6 mA |
| Operating Frequency | 20 kHz |
| Duty Cycle | 1:1 (Continuous/Intermittent) |
| Dimensions | Ø225 × 785 mm |
| Weight | 23 kg |
| Application | Tube-to-Tubesheet Weld Inspection |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AL-NP-6010A |
| Price Range | USD 280,000 – 425,000 |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | AL-Y3000 |
| Instrument Type | Powder X-ray Diffractometer |
| Angular Resolution | 0.001° (1/1000°) |
| Geometry | θ–θ configuration |
| X-ray Source | Sealed Metal-Ceramic Tube |
| Detector | Silicon Drift Detector (SDD) |
| Primary Optics | Interchangeable Focusing and Parallel-Beam Optics via 90° Monochromator Rotation |
| Software | Integrated Rietveld Refinement, ICDD/ICSD Database Integration, Stress & Texture Analysis Modules |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AL-Y3500 |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | High-Resolution X-ray Diffractometer |
| Configuration | Floor-Standing |
| Angular Resolution | Better than 0.0001° (2θ) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | ALL-5800A |
| Pricing | Upon Request |
| Input Voltage | 220 V AC, 50 Hz |
| X-ray Tube | Cu anode, air-cooled, 30 kV max tube voltage, 0–5 mA tube current |
| Detector | Geiger–Müller counter |
| Time Constant Settings | 1 s / 2 s / 3 s |
| Angular Display Reference | Certified Si or Al₂O₃ standard wafer/rod |
| Angular Adjustment Mechanism | Dedicated ±4° two-axis manual fine-adjustment fixture with symmetrical locking |
| Positioning Accuracy Reference | 0.5 mm feeler gauge |
| Sample Stage Translation (X-axis) | Motorized, auto-limited |
| Vertical Lift (Z-axis) | Motorized |
| Rotational Axis (θ) | Motorized, full 360° continuous rotation |
| Beam Shutter | Motorized |
| Dimensions (L×W×H) | 1025 × 1230 × 1950 mm |
| Weight | 620 kg |
| Brand | Aolong |
|---|---|
| Model | ALL-CKMD400 |
| Type | Benchtop X-ray Crystallographic Orientation Analyzer |
| X-ray Source | Cu-anode, air-cooled, grounded anode |
| Max. Tube Voltage/Current | 30 kV / 5 mA (continuous, adjustable |
| Detector | Proportional Counter (DC 1000 V max) or Scintillation Detector (DC 1200 V max) |
| Time Constant Settings | Fast (1 s) / Slow (2 s) |
| Angular Measurement | θ = 18.917° (18°55′00″) for <A> reference plane |
| Sample Diameter Compatibility | 2", 4", 6" cylindrical crystal rods |
| Primary Shutter | Motorized automatic shutter |
| Display | Analog μA meter (radiation intensity indicator) |
| Dimensions (L×W×H) | 1132 × 642 × 1460 mm |
| Weight | 200 kg |
| Power Input | AC 220 V, 50 Hz, 0.25 kW |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ALW-QZXD 800 |
| Pricing | Upon Request |
| Input Power | AC 220 V, 50 Hz, 0.25 kW |
| X-Ray Tube | Cu anode, fan-cooled, grounded anode |
| Max. Tube Voltage/Current | 30 kV / 5 mA (continuously adjustable) |
| Detector | Geiger-Müller counter (DC 1000 V max) or scintillation detector (DC 1200 V max) |
| Time Constant Settings | Fast (1) / Slow (2) |
| Angular Range | 2θ = −10° to 120° |
| Angular Resolution | 1 arcsecond (″) / 0.001° (digital display) |
| Repeatability | ±3″ |
| Measurement Accuracy | ±15″ (double-diffraction mode, verified with NIST-traceable quartz reference) |
| Optical Shutter | Motorized, auto-controlled |
| Display | Dual-channel digital readout (angle + X-ray intensity) |
| Dimensions (L×W×H) | 1132 × 642 × 1460 mm |
| Weight | 300 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ALW-XYDZ 700 |
| Power Supply | AC 220 V, 50 Hz, 0.25 kW |
| X-ray Tube | Cu anode, fan-cooled, grounded anode |
| Max. Tube Voltage/Current | 30 kV / 5 mA (continuously adjustable |
| Detector Options | Proportional counter (DC 1000 V max) or scintillation detector (DC 1200 V max) |
| Time Constant Settings | Fast (1) / Slow (2) |
| Angular Range | 2θ = −10° to 110°, θ = −5° to 55° |
| Angular Resolution | 1 arcsecond (1″), equivalent to 0.000278° |
| Angular Reproducibility | ±15″ / ±30″ (double-diffraction mode, verified with NIST-traceable quartz reference crystal) |
| Optical Shutter | Manual main shutter |
| Display Interface | Real-time angle readout + X-ray intensity meter |
| Dimensions (L×W×H) | 1132 × 642 × 1460 mm |
| Weight | 300 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ALW-XYDZ 700A |
| Price | Upon Request |
| Input Power | AC 220 V, 50 Hz, 0.25 kW |
| X-ray Tube | Cu anode, fan-cooled, grounded anode |
| Max. Tube Voltage/Current | 30 kV / 5 mA (continuously adjustable |
| Detector Options | Geiger–Müller counter (DC ≤1000 V) or scintillation detector (DC ≤1200 V) |
| Time Constant Settings | Fast (1) / Slow (2) |
| Angular Range | 2θ = −10° to 110°, θ = −5° to 55° |
| Angular Resolution | 1 arcsecond (″) in DMS format |
| Angular Accuracy (Double-Diffraction Mode) | ±15″ or ±30″ (verified using NIST-traceable quartz reference crystal) |
| Shielding | Fully enclosed lead-lined cabinet with interlocked automatic main shutter |
| Display | Dual digital readout — angular position (DMS + decimal degree, with presettable target and deviation) and X-ray intensity |
| Dimensions (L×W×H) | 1132 × 642 × 1460 mm |
| Weight | 300 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | ALYX-500 |
| Price | Upon Request |
| Input Power | 220 V AC, 50 Hz, 0.3 kW |
| X-ray Tube | Cu anode, air-cooled, 30 kV, 0–5 mA |
| Detector | Geiger–Müller counter |
| Angular Range | θ = −10° to +50°, 2θ = −10° to +100° |
| Angular Resolution | Digital readout with programmable positioning |
| Beam Shutter | Motorized |
| Dimensions | 700 × 530 × 1400 mm (L × W × H) |
| Weight | 100 kg |
| Brand | AoLong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | ALYX-600A |
| Pricing | Upon Request |
| Input Power | 220 V AC, 50 Hz, 0.25 kW |
| X-ray Tube | Cu anode, fan-cooled, grounded anode |
| Max. Tube Voltage/Current | 30 kV / 5 mA (continuously adjustable) |
| Detector | Proportional counter (max. operating voltage: DC 1000 V) or scintillation detector (max. operating voltage: DC 1200 V) |
| Time Constant | 2 settings (Fast: 1, Slow: 2) |
| Angular Range | 2θ = −10° to 120° |
| Angular Resolution | 1 arcsecond (″) — digital display in ° ′ ″ format |
| Angular Pre-setting | Digital numerical input with real-time feedback |
| Primary Beam Shutter | Motorized, automatic |
| Radiation Shielding | Fully enclosed lead-lined cabinet conforming to GBZ 117–2020 and IEC 61000-6-3 |
| Display Panel | Dual-channel LCD showing real-time angle and X-ray intensity |
| Overall Orientation Accuracy | ±15″ or ±30″ (verified using NIST-traceable quartz reference crystal) |
| Dimensions (L×W×H) | 1132 × 642 × 1460 mm |
| Weight | 300 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | ALYX-700 |
| Price | Upon Request |
| Input Power | 220 V AC, 50 Hz, 0.5 kW |
| X-ray Tube | Cu anode, air-cooled, 30 kV, 0–5 mA |
| Detector | Geiger–Müller counter |
| Time Constants | 0.1 s, 0.4 s, 3 s |
| Angle Readout | Digital display panel |
| Angular Adjustment | Precision rotary stage |
| Sample Positioning | Motorized automatic alignment |
| Beam Shutter | Electrically actuated |
| Dimensions | 1100 mm (L) × 1200 mm (W) × 1965 mm (H) |
| Weight | 450 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | ALYX-800 |
| Price | Upon Request |
| Input Power | 220 V AC, 50 Hz, 0.3 kW |
| X-ray Tube | Cu anode, air-cooled, 30 kV, 0–5 mA |
| Detector | Geiger-Müller counter |
| Time Constants | 0.1 s, 0.4 s, 3 s |
| Optical Shutter | Manual |
| Dimensions | 910 mm (L) × 660 mm (W) × 1220 mm (H) |
| Weight | 150 kg |
| Brand | AoLong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Lab-Specific In Vivo Micro-CT Imaging System |
| Instrument Type | Tomographic Imaging |
| Tube Voltage | 20–90 kV |
| Focal Spot Size | 5 µm |
| Spatial Resolution | 3 µm |
| Density Resolution | 0.3–0.5% |
| Scan Geometry | Cone-Beam |
| Detector | Digital Flat-Panel Detector |
| Scan Time | 30 s – 2 min |
| Image Reconstruction Speed | 1024×1024, 720 projections |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | μCT-90 |
| Price Range | USD 140,000 – 420,000 |
| X-ray Tube Voltage | 20–90 kV |
| Focal Spot Size | ≤5 µm |
| Density Resolution | 0.3–0.5% |
| Scan Geometry | Cone-Beam CT (CBCT) |
| Detector | High-Resolution Amorphous Silicon Flat-Panel Detector |
| Reconstructed Voxel Resolution | Sub-micron to ~10 µm (system-dependent) |
| Maximum Sample Diameter | ≤90 mm |
| Maximum Sample Height | ≤120 mm |
| Rotation Accuracy | < 0.01° |
| Image Reconstruction Algorithm | Filtered Back Projection (FBP) and Iterative Reconstruction (IR) Options |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Benchtop Microfocus CT System for Cultural Heritage Analysis |
| Pricing | Upon Request |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Casting X-ray Inspection System |
| Price | Upon Request |
| Tube Voltage | 20–450 kV |
| Tube Current | 0.1–20 mA |
| Repeatability | ±0.01% |
| High-Voltage Rise Time | 0.1–0.3 ms |
| System Spatial Resolution | 16–60 lp/cm (dual-range configuration) |
| Contrast Sensitivity | 1.2–1.5% |