GBPI
Filter
Showing 1–30 of 448 results
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GX-C2 |
| Price Range | USD 7,000 – 14,000 |
| Instrument Category | Coefficient of Friction Tester |
| Maximum Scratching Force | 20 ± 0.2 N |
| Force Resolution | 0.2 N |
| Maximum Operating Temperature | 150 °C |
| Scratching Speed | 0–43 cycles/min |
| Scratching Area | 240 mm (L) × 50 mm (W) |
| Cycle Count Range | 1–999,999 |
| Specimen Dimensions | 320 mm (L) × 50 mm (W) |
| Overall Dimensions | 440 mm × 400 mm × 200 mm |
| Power Consumption | 430 W |
| Input Power | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Thickness | 125 μm |
| Material | Biaxially Oriented Polyethylene Terephthalate (BOPET) |
| Certified Reference Material (CRM) Designation | GBW(E)130541 |
| Compliance | GB/T 1038–2000 (Differential Pressure Method) |
| Certification Level | China National Secondary Standard Substance |
| Origin | Guangdong, China |
| Manufacturer | Guangzhou GBPI Instrument Co., Ltd. |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | 4510F |
| Automation Level | Fully Automated |
| Lamp Holder | Rotating 4-Lamp Turret |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.15 nm |
| Absorbance Range | –0.1 to 2.5 A |
| Spectral Bandwidth | 0.1 / 0.2 / 0.4 / 1.0 nm (selectable) |
| Baseline Stability | ≤0.005 A/30 min (Cu) |
| D₂ Background Correction | ≥50× at 1 A background signal |
| Self-Reversal Background Correction | Supported |
| Flame System | Acetylene-Air, 100 mm Burner Head |
| Nebulizer Chamber | Polypropylene-Coated |
| Characteristic Concentration (Cu) | ≤0.02 µg/mL per 1% absorption |
| RSD of Measurement | ≤0.5% |
| Detection Limit (Cu) | ≤0.006 µg/mL |
| Safety Interlocks | Gas pressure monitoring, flame-out detection, power interruption cutoff, burner head recognition |
| Optional Accessories | 4510GF Graphite Furnace Module, AS4020 Graphite Furnace Autosampler, AS800 Chiller Unit, Hydride Generation System |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | 9023 |
| Pricing | Available Upon Request |
| Temperature Range | RT +10°C to 300°C |
| Temperature Uniformity | ≤ ±3°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Sensor | Pt100 Platinum Resistance Thermometer |
| Display | LED Digital |
| Exterior | Powder-Coated Cold-Rolled Steel with Anti-Rust Treatment |
| Interior | SUS304 Brushed Stainless Steel |
| Insulation | High-Performance Glass Wool |
| Heating Element | Nickel-Chromium Alloy Wire |
| Circulation Fan | Centrifugal Blower |
| Safety Protections | Over-Temperature Cut-Off, Fan Overheat Protection |
| Shelf Load Capacity | 5 kg per shelf |
| Internal Dimensions (D×W×H) | 300 × 300 × 275 mm |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | AUTO GQ300 |
| Price | Upon Request |
| Gas Measurement Range | O₂: 0–30% (v/v), CO₂: 0–20% (v/v), C₂H₄: 0–200 ppm |
| Gas Measurement Accuracy | O₂: ±0.01%, CO₂: ±0.01%, C₂H₄: ±0.1 ppm |
| Gas Purity Requirement | ≥99.9% for O₂, CO₂, N₂, and C₂H₄ |
| Gas Flow Control | O₂/CO₂/N₂: 0–500 mL/min each |
| Temperature Range | −5°C to +45°C |
| Temperature Uniformity & Stability | ±0.5°C |
| Humidity Range | Ambient to 95% RH |
| Humidity Fluctuation | ±3% RH |
| Refrigeration Capacity | 1 HP |
| Humidifier Power | 50 W |
| Illumination Power | 10 W |
| Chamber Material | Color-coated steel exterior, stainless-steel interior |
| Dimensions (W×D×H) | 935 mm × 1290 mm × 1850 mm |
| Total Power Consumption | 3 kW |
| Number of Independent Test Chambers | 3 |
| Power Supply | AC 220 V |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | BFH-200 |
| Price | USD 27,500 (FOB Guangzhou) |
| Spectral Range | 350–7800 cm⁻¹ |
| Spectral Resolution | <1.0 cm⁻¹ |
| Signal-to-Noise Ratio | 40,000:1 (peak-to-peak, 4 cm⁻¹, 1 min scan) |
| Light Source | Ge-coated KBr beam splitter (imported) |
| Interferometer | Non-orthogonal Michelson-type with DSP-controlled electromagnetic drive |
| Detector | DLATGS with anti-humidity coating (imported) |
| Operating Systems | Windows XP through Windows 10 (64-bit compatible) |
| Dimensions | 450 × 350 × 210 mm |
| Weight | 13 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | BFH-960-aa |
| Pricing | Available Upon Request |
| Spectral Range | 7800–350 cm⁻¹ |
| Resolution | <1.0 cm⁻¹ |
| Signal-to-Noise Ratio | >15,000:1 (4 cm⁻¹, 1-min scan) / >30,000:1 (4 cm⁻¹, 1-min scan) |
| Beamsplitter | Ge-coated KBr substrate |
| Detector | Imported high-sensitivity deuterated triglycine sulfate (DLaTGS) |
| Source | Imported long-life, air-cooled high-intensity IR source |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Transmittance Precision | ±0.5%T |
| Interferometer | Sealed 30°-incidence Michelson interferometer with built-in auto-alignment optics |
| Laser | VCSEL-based He–Ne equivalent reference laser (≥10-year lifetime) |
| A/D Conversion | 24-bit, 500 kHz |
| Interface | USB 2.0 (backward/forward compatible with USB 3.0) |
| Operating Temperature | 15–35 °C |
| Dimensions | 450 × 350 × 235 mm (L×W×H) |
| Weight | 14 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 7800–350 cm⁻¹ |
| Resolution | <1.0 cm⁻¹ |
| Scan Speed | 4 cm⁻¹ |
| Signal-to-Noise Ratio | 15,000:1 (at 4 cm⁻¹, 1 min scan) / 30,000:1 (at 4 cm⁻¹, 5 min scan) |
| Beamsplitter | KBr substrate with Ge coating |
| Detector | Imported high-sensitivity DLaTGS |
| Source | Imported long-life, air-cooled high-intensity IR source |
| Interferometer | Sealed 30°-incidence Michelson interferometer with automatic optical alignment |
| Laser | VCSEL-based He–Ne reference laser |
| A/D Conversion | 24-bit, 500 kHz |
| Communication Interface | USB 2.0 (backward compatible with USB 3.0) |
| Dimensions | 450 × 350 × 235 mm (L×W×H) |
| Weight | 14 kg |
| Operating Temperature | 15–35 °C |
| Power Consumption | <30 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | <1.0 cm⁻¹ |
| Scan Speed | 4 cm⁻¹ (optical path difference rate) |
| Signal-to-Noise Ratio | 15,000:1 (at 4 cm⁻¹, 1 min scan) / 30,000:1 (at 4 cm⁻¹, 1 min scan, DLaTGS detector) |
| Beamsplitter | KBr substrate with Ge coating |
| Detector | Imported high-sensitivity deuterated triglycine sulfate (DLaTGS) |
| Source | Imported long-life, air-cooled high-intensity IR source |
| Interferometer | Sealed 30°-incidence Michelson interferometer with integrated auto-alignment optics |
| A/D Conversion | 24-bit, 500 kHz |
| Communication Interface | USB 2.0 (backward compatible with USB 3.0) |
| Dimensions | 450 × 350 × 235 mm (L×W×H) |
| Weight | 14 kg |
| Operating Temperature | 15–35 °C |
| Power Consumption | <30 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | BJ-GC128 |
| Price | USD 22,000 (FOB Guangdong) |
| Touchscreen | 7-inch color capacitive display |
| Control Architecture | Dual-mode—embedded real-time OS + PC-based bidirectional software control |
| EFC/EPC | Electronic Flow Control / Electronic Pressure Control on all inlets and detectors |
| Inlet Zones | 2 independently heated (up to 400 °C), compatible with packed columns (φ3/φ4) and split/splitless capillary inlets |
| Detector Options | FID (MDL ≤ 2.5×10⁻¹² g/s n-hexadecane, dynamic range 10⁷), TCD (sensitivity ≥ 5000 mV·mL/mg n-hexadecane, baseline drift ≤ 0.15 mV/30 min), ECD (⁶³Ni source, MDL ≤ 80 fg/s, γ-HCH ≤ 8×10⁻¹⁴ g/mL, dynamic range 10³), FPD (P: MDL ≤ 2×10⁻¹² g/s, S: ≤ 4×10⁻¹¹ g/s, methyl parathion, P/S dynamic range 10³/10²) |
| Oven Specifications | Internal dimensions 280 × 310 × 160 mm |
| operating range | ambient +4 °C to 420 °C |
| Auxiliary Heaters | 2 additional zones (max 400 °C) |
| External Event Ports | 8 TTL-compatible digital I/O channels for valve sequencing, autosampler triggering, or thermal desorption synchronization |
| Connectivity | RS-232 serial port, LAN (LAM protocol), 20 method storage slots |
| Safety Features | Automatic oven fan & heater shutdown upon column chamber door opening |
| Power Requirements | 220 VAC ±10%, 50/60 Hz, 3000 W max |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | CHY-G |
| Pricing | Upon Request |
| Measurement Principle | Capacitive Grid Sensing |
| Display | 7-inch Color Touchscreen LCD |
| Control System | Microcomputer-based |
| Thickness Range | 0–12.7 mm |
| Resolution | 0.001 mm (0.00005″) |
| Sample Diameter | 5–300 mm (customizable) |
| Sample Height | 5–330 mm (customizable) |
| Dimensions (L×W×H) | 400 × 360 × 700 mm |
| Interface | USB |
| Operating Temperature | 15–50 °C |
| Relative Humidity | 10–90% RH (non-condensing) |
| Power Supply | 220 V AC, 50 Hz, 60 W |
| Compliance | YBB00332002-2015, YBB00332003-2015, YBB00032004-2015, GB 12415-90 |
| Data Management | Built-in statistical analysis (max/min/mean), audit trail, user-level permission control, thermal printer integration |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | CYLLX |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | DHG-9023A-aa |
| Temperature Range | Ambient +10°C to 300°C |
| Temperature Uniformity | ≤±3°C |
| Temperature Fluctuation | ≤±0.5°C |
| Internal Dimensions (D×W×H) | 300 mm × 300 mm × 275 mm |
| External Dimensions (D×W×H) | 625 mm × 500 mm × 490 mm |
| Inner Chamber Material | SUS304 Brushed Stainless Steel |
| Heating Method | Nickel-Chromium Alloy Wire with Centrifugal Forced-Air Circulation |
| Power Rating | 1000 W |
| Supply Voltage/Frequency | 220 V, 50 Hz |
| Net Weight | 31.5 kg |
| Safety Protections | Over-Temperature Cut-Off, Fan Overheat Protection |
| Shelf Load Capacity | 5 kg |
| Sensor | Pt100 Platinum Resistance Thermometer |
| Display | LED Digital |
| Insulation | Super Glass Wool |
| Outer Casing | Cold-Rolled Steel with Anti-Rust Coating and Powder Finish |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | DHG-9030A-aa |
| Temperature Range | +10 °C to +200 °C |
| Temperature Uniformity | ≤ ±0.5 °C |
| External Dimensions | 625 mm × 500 mm × 490 mm |
| Internal Chamber Dimensions | 300 mm × 300 mm × 350 mm |
| Chamber Material | Stainless Steel (SUS304) |
| Heating Method | Electrically Heated Forced-Air Circulation |
| Rated Power | 1000 W |
| Electrical Supply | 220 V, 50 Hz |
| Instrument Class | Precision Laboratory Drying Oven |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | FT-01 |
| Pricing | Upon Request |
| Measurement Range | 0.02–50,000 cm³/m²·day·0.1 MPa (expandable to 600,000 cm³/m²·day·0.1 MPa) |
| Measurement Resolution | 0.01 cm³/m²·day·0.1 MPa |
| Temperature Range | 5–50 °C |
| Temperature Control Accuracy | ±0.01 °C |
| Humidity Range | 0 %RH (5–100 %RH optional) |
| Humidity Control Accuracy | ±2 %RH |
| Vacuum Accuracy | 0.1 Pa |
| Test Chamber Vacuum Level | <20 Pa |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Test Gases | O₂, CO₂, N₂ |
| Max. Sample Thickness | ≤2 mm |
| Test Area | 50.24 cm² (Φ80 mm) |
| Power Supply | 220 V AC, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GB-4RTR |
| Quotation | Upon Request |
| Aerosol Output Capacity | 2–6 L/h (adjustable) |
| Aerosol Airflow Rate | 65 L/min |
| Aerosol Particle Size Distribution | 2–10 µm |
| Integrated Reservoir Volume | 20 L |
| Optional External Tank Volume | 50 L |
| Manual Spray Wand (optional) | 110 mm |
| Dimensions (W×D×H) | 510 × 600 × 860 mm |
| Power Supply | 220 V AC, 750 W |
| Control Interface | 7-inch capacitive touchscreen |
| Compliance | GB 150.4–2011, GB/T 9706.1–2007, WS/T 367–2012 |
| Brand | GBPI |
|---|---|
| Model | GB-B20010 |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Pressure Points | 3 kPa, 5 kPa, 7 kPa, 14 kPa, 20 kPa |
| Specimen Size | 75 mm × 75 mm |
| Pressurized Area | 28.27 cm² |
| Power Supply | AC 220 V, 50 Hz, 100 W |
| Air Source | Compressed Air |
| Pressure Regulation | Adjustable, with Analog Pressure Gauge |
| Clamping Torque | 13.5 N·m |
| Retention Mesh | Stainless Steel, Open Area ≥50%, Deflection ≤5 mm at 20 kPa |
| Timer | Digital, ±1 s Accuracy |
| Compliance | GB 19083–2010 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GB-BF20010 |
| Pressure Test Points | 3 kPa, 5 kPa, 7 kPa, 14 kPa, 20 kPa |
| Specimen Size | 75 mm × 75 mm |
| Pressurized Area | 28.27 cm² |
| Power Supply | AC 220 V, 50 Hz, 100 W |
| Air Pressure Source | Adjustable compressed air up to (20 ± 1) kPa |
| Pressure Display | Analog pressure gauge with manual regulation |
| Test Chamber | Stainless steel penetration test chamber with leak-resistant sealing |
| Support Grid | Square metal retainer mesh, ≥50% open area, deflection ≤5 mm at 20 kPa |
| Clamping Torque | 13.5 N·m |
| Timer | Digital display timer, accuracy ±1 s |
| Brand | GBPI |
|---|---|
| Model | GB-BF20010A |
| Pressure Settings | 3, 5, 7, 14, 20 kPa |
| Test Area | 28.27 cm² (75 mm × 75 mm specimen) |
| Air Supply | Compressed air, regulated to (20 ± 1) kPa |
| Power Supply | AC 220 V, 50 Hz, 100 W |
| Timer Resolution | ±1 s |
| Clamp Torque | 13.5 N·m |
| Retention Mesh | ≥50% open area, ≤5 mm deflection at 20 kPa |
| Construction | Stainless steel test chamber with integrated specimen retention system |
| Brand | GBPI |
|---|---|
| Model | GB-BF20010CT |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Pressure Settings | 3 kPa, 5 kPa, 7 kPa, 14 kPa, 20 kPa |
| Specimen Size | 75 mm × 75 mm |
| Pressurized Area | 28.27 cm² |
| Power Supply | AC 220 V, 50 Hz, 100 W |
| Air Source Requirement | Compressed air capable of delivering (20 ± 1) kPa |
| Clamp Torque | 13.5 N·m |
| Retention Mesh | ≥50% open area |
| Timer Resolution | ±1 s |
| Test Medium | ASTM F1862-compliant synthetic blood surrogate |
| Brand | GBPI |
|---|---|
| Model | GB-BF20010M |
| Pressure Settings | 3, 5, 7, 14, 20 kPa |
| Test Area | 28.27 cm² (75 mm × 75 mm specimen) |
| Air Supply | Compressed air, regulated to (20 ± 1) kPa |
| Power | AC 220 V, 50 Hz, 100 W |
| Timer Resolution | ±1 s |
| Clamp Torque | 13.5 N·m |
| Retention Mesh | ≥50% open area, ≤5 mm deflection at 20 kPa |
| Construction | Stainless steel test chamber |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GB-D100A |
| Quotation | Upon Request |
| Aerosol Output Capacity | 2–6 L/h (adjustable) |
| Aerosol Flow Rate | 65 L/min |
| Aerosol Particle Size | 2–10 µm |
| Built-in Tank Capacity | 20 L |
| Optional External Tank Capacity | 50 L |
| Manual Spray Wand (optional) | 110 mm |
| Dimensions (W×D×H) | 510 × 600 × 860 mm |
| Power Supply | 220 V AC, 750 W |
| Compliance | GB 150.4–2011, GB/T 9706.1–2007, WS/T 367–2012 |
| Brand | GBPI |
|---|---|
| Model | GB-DK |
| Measurement Principle | Fluorescence-based Optical O₂ Detection & NDIR CO₂ Detection |
| Measuring Gases | O₂ (standard), CO₂ (optional) |
| O₂ Range | 0–25% vol |
| CO₂ Range | 0–100% vol |
| O₂ Accuracy | ±0.2% vol |
| CO₂ Accuracy | ±2% vol |
| Minimum Sample Volume | ≥3 mL (at 101.3 kPa) |
| Sampling Method | Vacuum-assisted needle puncture |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Weight | 5 kg |
| Power Supply | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| Compliance | Designed per Annex 11 (EU GMP), FDA 21 CFR Part 11, and ISO 11607-2 requirements for packaging integrity validation |
| Brand | GBPI |
|---|---|
| Model | GB-DK1 |
| Measurement Principle | Fluorescence-based Optical O₂ Detection & NDIR CO₂ Detection (optional) |
| Gas Types | O₂ (standard), CO₂ (optional) |
| O₂ Range | 0–25% vol |
| CO₂ Range | 0–100% vol |
| O₂ Accuracy | ±0.2% vol |
| CO₂ Accuracy | ±2% vol |
| Minimum Sample Volume | ≥3 mL (at 101.3 kPa) |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Power Supply | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| Net Weight | 5 kg |
| Compliance | Designed per GMP Annex 11 (Computerized Systems), supports ALCOA+ data integrity principles |
| Operating Environment | Production line, warehouse, QC lab |
| Brand | GBPI |
|---|---|
| Model | GB-DK1E |
| Measurement Principle | Fluorescence-based Optical O₂ Detection & NDIR CO₂ Detection (optional) |
| Gas Range | O₂ 0–25% (±0.2% accuracy), CO₂ 0–100% (±2% accuracy) |
| Sampling Volume | ≥5 mL (O₂), ≥20 mL (CO₂) |
| Dimensions | 350 × 330 × 200 mm |
| Weight | 5 kg |
| Power | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| Compliance | Designed per GMP Annex 11 & FDA 21 CFR Part 11 requirements for computerized systems |
| Operating Environment | Lab, QC, warehouse, or inline packaging environments |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | GB-F1 |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GB-FB1 |
| Pricing | Upon Request |
| Test Standards | GB 10006, ISO 8295, ASTM D1894, TAPPI T816 |
| Friction Coefficient Range | 0.001–0.999 |
| Resolution | 0.1 |
| Force Measurement Range | 0–9.8 N |
| Slider Velocity | 0–500 mm/min (infinitely variable |
| standard test speeds | 100 ±10 mm/min and 150 ±10 mm/min) |
| Stroke Length | 100 ±5 mm |
| Max Sample Thickness | ≤2 mm |
| Slider Dimensions | 63 mm × 63 mm |
| Slider Mass | 200 g ±2 g |
| Test Platform Size | 200 mm × 470 mm |
| Display | LCD screen |
| Overall Dimensions | 470 mm × 340 mm × 220 mm |
| Power Consumption | 100 W |
| Electrical Supply | AC 220 V ±10 V, 50 Hz |
| Net Weight | 13.6 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GB-HQ1000 |
| Instrument Category | Resistance-Based Particle Counter |
| Power Supply | 220 V, 50 Hz |
| Display | Integrated HD Touchscreen |
| Vacuum Pump Flow Rate | 2 L/min |
| Buffer Chamber Capacity | 5 L |
| Pressure Sensor Range | −1000 Pa to 0 Pa (Accuracy: ±1%, Resolution: 1 Pa) |
| Flow Meter Range | 0–100 mL/min (Accuracy: ±1%, Resolution: 0.1 mL/min) |
| Compliance Standard | GB 2626–2019 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GB-HQ1000 |
| Price Range | USD 14,000 – 42,000 |
| Air Source | Compressed Air |
| Vacuum Pump Flow Rate | 2 L/min |
| Buffer Tank Volume | 5 L |
| Pressure Sensor Range | −1000 Pa to 0 Pa |
| Pressure Sensor Accuracy | ±1% FS |
| Pressure Resolution | 1 Pa |
| Flow Meter Range | 0–100 mL/min |
| Flow Meter Accuracy | ±1% FS |
| Flow Resolution | 0.1 mL/min |
| Display | Integrated HD Touchscreen Interface |
| Power Supply | 220 V AC, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GB-HQ1000-1 |
| Price Range | USD 70,000 – 140,000 |
| Instrument Type | Optical Particle Counter |
| Air Source | Compressed Air |
| Vacuum Pump Flow Rate | 2 L/min |
| Buffer Tank Volume | 5 L |
| Pressure Sensor Range | −1000 Pa to 0 Pa, Accuracy: ±1%, Resolution: 1 Pa |
| Flow Meter Range | 0–100 mL/min, Accuracy: ±1%, Resolution: 0.1 mL/min |
| Display | Integrated HD Touchscreen |
| Power Supply | 220 V, 50 Hz |