| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Category | Domestic (China) |
| Model | Y110-aa |
| Price Range | USD 14,000 – 70,000 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Y110-1 |
| Price Range | USD 14,000 – 70,000 |
| Test Principle | Coulometric Sensor-based OTR Measurement (ISO 15105-2, ASTM D3985) |
| Measurement Range | 0.02–16,500 cm³/(m²·24h) [extendable to 260,000 cm³/(m²·24h) with auxiliary fixture] |
| Accuracy | ±0.001 cm³/(m²·24h) |
| Temperature Control | 15–45 °C, ±0.1 °C |
| Humidity Control | 0–90 % RH, ±1 % RH |
| Permeation Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1 test cell (expandable to 10 cells) |
| Carrier Gas Pressure | ≥0.1 MPa |
| Gas Inlet | 1/8″ NPT |
| Dimensions | 600 × 400 × 330 mm |
| Power | 500 W, AC 220 V / 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Y110-bb |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (up to 260,000 cm³/(m²·24h) with large-area mask) |
| Measurement Accuracy | 0.001 cm³/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temp. Stability | ±0.1 °C |
| Humidity Control Range | 0–90 %RH |
| RH Stability | ±1 %RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Max. Thickness | ≤3 mm |
| Sample Capacity | 1 unit per test |
| Carrier Gas Pressure | ≥0.1 MPa |
| Gas Inlet | Φ3 mm tubing / 1/8″ NPT |
| Dimensions | 600 × 400 × 330 mm |
| Power | 500 W |
| Supply | AC 220 V, 50 Hz |
| Compliance | GB/T 19789–2005, YBB00082003–2015, ASTM D3985, ASTM F2622, ASTM F1927, ASTM F1307, ISO 15105-2, DIN 53380-3, JIS K-7126-B |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | Y110-D |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) [up to 260,000 cm³/(m²·24h) with mask accessory] |
| Accuracy | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45 °C ±0.1 °C |
| Humidity Control | 30–90 %RH ±1 %RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixture) |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Quantity | 1 per test |
| Carrier Gas Pressure | ≥0.1 MPa |
| Gas Inlet | Φ3 mm tubing / 1/8″ NPT |
| Dimensions | 600 × 400 × 330 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Compliance | GB/T 19789–2005, YBB 00082003–2015, ASTM D3985, ASTM F2622, ASTM F1927, ASTM F1307, ISO 15105-2, DIN 53380-3, JIS K-7126-B |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Region Category | Domestic |
| Model | Y110-P |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (up to 260,000 cm³/(m²·24h) with mask accessory) |
| Accuracy | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45 °C ±0.1 °C |
| Humidity Control | 30–90 %RH ±1 %RH |
| Permeation Area | 50.24 cm² (down to 0.785 cm² with optional fixture) |
| Specimen Size | Φ100 mm |
| Max Thickness | ≤3 mm |
| Sample Quantity | 1 |
| Carrier Gas Pressure | ≥0.1 MPa |
| Gas Inlet | Φ3 mm tubing / 1/8″ NPT |
| Dimensions | 600 × 400 × 330 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Y110-T |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (up to 260,000 cm³/(m²·24h) with mask accessory) |
| Accuracy | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45 °C ±0.1 °C |
| Humidity Control | 30–90 %RH ±1 %RH |
| Permeation Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Quantity | 1 pc |
| Carrier Gas Pressure | ≥0.1 MPa |
| Gas Inlet | Φ3 mm tubing / 1/8″ NPT |
| Dimensions | 600 × 400 × 330 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Y110A |
| Test Range | 0.02–16,500 cm³/(m²·24h) |
| Extended Range (with shroud) | up to 260,000 cm³/(m²·24h) |
| Measurement Accuracy | 0.001 cm³/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temp. Stability | ±0.1 °C |
| Humidity Control Range | 30–90 %RH (including 100 %RH) |
| RH Stability | ±1 %RH |
| Permeation Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Sample Capacity | 1 unit per test |
| Carrier Gas Pressure | ≥0.1 MPa |
| Gas Inlet | Φ3 mm tubing / 1/8″ NPT |
| Dimensions | 600 × 400 × 330 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Compliance | GB/T 19789–2005, YBB00082003–2015, ASTM D3985, ASTM F2622, ASTM F1927, ASTM F1307, ISO 15105-2, DIN 53380-3, JIS K-7126-B |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Y110E |
| Test Range | 0.02–16,500 cm³/(m²·24h) [up to 260,000 cm³/(m²·24h) with optional mask] |
| Accuracy | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45 °C ±0.1 °C |
| Humidity Control | 30–90% RH & 100% RH ±1% RH |
| Permeation Area | 50.24 cm² (down to 0.785 cm² with accessories) |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1 unit |
| Carrier Gas Pressure | ≥0.1 MPa |
| Gas Inlet | Φ3 mm tubing / 1/8″ NPT |
| Dimensions | 600 × 400 × 330 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Y110P 2.0 |
| Price Range | USD 39,800 – 53,600 |
| Test Principle | Coulometric Oxygen Sensor (ASTM D3985-compliant) |
| Standards Compliance | GB/T 31354-2014, GB/T 19789-2005, ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, ISO 15105-2, JIS K-7126-B, DIN 53380-3 |
| Package Test Range | 0.00025–1 cm³/pkg·day |
| Film Test Range | 0.01–1000 cm³/(m²·24h·0.1 MPa) |
| Resolution (Package) | 0.0001 cm³/pkg·day |
| Resolution (Film) | 0.0001 cm³/(m²·24h·0.1 MPa) |
| Temperature Control Range | 15–45 °C |
| Temp. Accuracy | ±0.5 °C |
| Humidity Control Range | 20–95 %RH |
| RH Accuracy | ±2 %RH |
| Sample Capacity | 1 package per test cycle |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Interface | 1/8″ stainless steel tubing |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | Y110P 2.0A |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | Y110P 2.0L |
| Price Range | USD 40,000 – 54,000 |
| Test Principle | Coulometric Oxygen Sensor (ASTM D3985-compliant) |
| Standards | GB/T 31354-2014, GB/T 19789-2005, ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, ISO 15105-2, JIS K-7126-B, DIN 53380-3 |
| Package OTR Range | 0.00025–1 cm³/pkg·day |
| Film OTR Range | 0.01–1000 cm³/(m²·24h·0.1 MPa) |
| Resolution (Package) | 0.0001 cm³/pkg·day |
| Resolution (Film) | 0.0001 cm³/(m²·24h·0.1 MPa) |
| Temperature Control Range | 15–45 °C |
| Temp. Accuracy | ±0.5 °C |
| Humidity Control Range | 20–95 %RH |
| RH Accuracy | ±2 %RH |
| Sample Capacity | 1 package per test cycle |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Interface | 1/8″ stainless steel tubing |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Y201D |
| Pricing | Upon Request |
| Test Principle | Differential Pressure (Manometric) Method |
| Compliant Standards | ISO 2556:2001, ISO 15105-1:2007, GB/T 1038–2000, ASTM D1434–82 (Reapproved 2003), YBB00082003 |
| Measurement Range | 0.02–50,000 cm³/m²·day·0.1 MPa (expandable to 600,000 cm³/m²·day·0.1 MPa) |
| Measurement Resolution | 0.01 cm³/m²·day·0.1 MPa |
| Temperature Control Range | 5–50 °C |
| Temperature Stability | ±0.01 °C |
| Humidity Control Range | 0 %RH (5–100 %RH optional) |
| Humidity Accuracy | ±2 %RH |
| Vacuum Capability | <20 Pa base pressure |
| Vacuum Accuracy | 0.1 Pa |
| Test Pressure Range | –0.1 to +0.1 MPa |
| Test Gases | O₂, CO₂, N₂ |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Y210 |
| Measurement Principle | Coulometric Sensor (Electrochemical Oxygen Detection) |
| Standards Compliance | GB/T 19789–2005, ASTM D3985, ASTM F2622, ASTM F1927, ASTM F1307, ISO 15105-2, YBB00082003, DIN 53380-3, JIS K-7126-B |
| Oxygen Transmission Rate (OTR) Range | 0.02–16,500 cm³/(m²·24 h) for films |
| Accuracy | ±0.001 cm³/(m²·24 h) |
| Temperature Control Range | 15–45 °C |
| Temperature Stability | ±0.1 °C |
| Humidity Control Range | 0 %RH (dry), 30–90 %RH, and 100 %RH |
| Humidity Stability | ±1 %RH |
| Test Area | 50.24 cm² (Φ80 mm) |
| Sample Thickness Limit | ≤2 mm |
| Sample Quantity | 2 specimens per test cycle |
| Operating Pressure | 0.2–0.3 MPa |
| Carrier Gas Interface | 1/8″ stainless steel tubing |
| Calibration Options | Certified reference films and standard gases |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Region | Domestic (China) |
| Model | Y210-aa |
| Price Range | USD 14,000 – 70,000 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Y210 |
| Pricing | Upon Request |
| Test Principle | Differential Pressure (Manometric) Method |
| Standards Compliance | ISO 2556:2001, ISO 15105-1:2007, ASTM D1434–82 (Reapproved 2003), GB/T 1038–2000, YBB00082003 |
| Measurement Range | 0.02–50,000 cm³/(m²·day·0.1 MPa) [expandable to 600,000 cm³/(m²·day·0.1 MPa)] |
| Accuracy | ±0.01 cm³/(m²·day·0.1 MPa) |
| Temperature Control Range | 5–50 °C |
| Stability | ±0.01 °C |
| Humidity Control Range | 0% RH (5–100% RH optional) |
| Accuracy | ±2% RH |
| Vacuum Capability | ≤20 Pa base pressure |
| Absolute vacuum resolution | 0.1 Pa |
| Test Gas Compatibility | O₂, CO₂, N₂ |
| Sample Thickness Limit | ≤2 mm |
| Effective Test Area | 50.24 cm² (Φ80 mm) |
| Power Supply | 220 V AC, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Y210 |
| Pricing | Upon Request |
| Measurement Principle | Differential Pressure (Manometric) Method |
| Standards Compliance | ISO 2556:2001, ISO 15105-1:2007, ASTM D1434–82 (Reapproved 2003), GB/T 1038–2000, YBB 00082003–2015 |
| Measurement Range | 0.02–50,000 cm³/m²·day·0.1 MPa (expandable to 600,000 cm³/m²·day·0.1 MPa) |
| Accuracy | ±0.01 cm³/m²·day·0.1 MPa |
| Temperature Control Range | 5–50 °C |
| Temp. Stability | ±0.01 °C |
| Humidity Control | 0% RH standard |
| Humidity Accuracy | ±2% RH |
| Vacuum Capability | ≤20 Pa base pressure |
| Test Gas | O₂, CO₂, N₂ |
| Specimen Thickness | ≤2 mm |
| Test Area | 50.24 cm² (Φ80 mm) |
| Power Supply | 220 V AC, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | Y310 2.0 |
| Price | USD 55,000 (FOB Guangzhou) |
| Test Range | 0.01–1000 cm³/(m²·24h·0.1 MPa) |
| Repeatability | ±0.01 cm³/(m²·24h·0.1 MPa) or ±2%, whichever is greater |
| Resolution | 0.0001 cm³/(m²·24h·0.1 MPa) |
| Temperature Control Range | 15–45 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0% RH, 5–90% RH, 100% RH |
| Humidity Accuracy | ±2% RH |
| Test Area | 50.24 cm² (customizable down to 0.785 cm²) |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Test Stations | 3 independent chambers |
| Carrier Gas Pressure | ≥0.1 MPa |
| Carrier Gas Flow Rate | 5–100 mL/min |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Dimensions | 700 × 655 × 390 mm |
| Weight | 60 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GBPI Y310 2.0 |
| Price | USD 54,500 (FOB Guangzhou) |
| Test Principle | Coulometric Oxygen Sensor Method |
| Standards Compliance | GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1927, ASTM F1307, ISO 15105-2, DIN 53380-3, JIS K-7126-B, YBB 00082003 |
| Measurement Range | 0.05–1000 cm³/(m²·24 h) (up to 260,000 cm³/(m²·24 h) with auxiliary mask) |
| Resolution | 0.001 cm³/(m²·24 h) |
| Temperature Control Range | 15–45 °C |
| Temperature Stability | ±0.1 °C |
| Test Area | 50.24 cm² (customizable down to 0.785 cm²) |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 independent test chambers |
| Carrier Gas Pressure | ≥0.1 MPa |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power Consumption | 750 W |
| Electrical Supply | AC 220 V, 50 Hz |
| [Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Scientific Instrument |
| Model | Y310 2.0A |
| Test Range | 0.05–1000 cm³/(m²·24 h) (up to 260,000 cm³/(m²·24 h) with mask adapter) |
| Resolution | 0.001 cm³/(m²·24 h) |
| Temperature Control Range | 15–45 °C |
| Temperature Stability | ±0.1 °C |
| Permeation Area | 50.24 cm² (customizable down to 0.785 cm²) |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 independent test cells |
| Carrier Gas Pressure | ≥0.1 MPa |
| Pneumatic Actuation Pressure | ≥0.3 MPa |
| Power Consumption | 750 W |
| Electrical Supply | AC 220 V, 50 Hz] |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GBPI Y310 2.0A |
| Test Principle | Coulometric Sensor Method |
| Standards Compliance | GB/T 19789, ASTM D3985, ASTM F1307, ASTM F1927, ASTM F2622, ISO 15105-2, YBB 00082003, DIN 53380-3, JIS K-7126-B |
| Measurement Range | 0.05–1000 cm³/(m²·24h) (up to 260,000 cm³/(m²·24h) with custom mask) |
| Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temperature Stability | ±0.1 °C |
| Test Area | 50.24 cm² (customizable down to 0.785 cm²) |
| Sample Diameter | Φ100 mm |
| Max Sample Thickness | ≤3 mm |
| Sample Capacity | 3 independent test chambers |
| Carrier Gas Pressure | ≥0.1 MPa |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W |
| Input | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Region Category | Domestic (China) |
| Model | Y310 2.0T |
| Test Range | 0.05–1000 cm³/(m²·24h) (up to 260,000 cm³/(m²·24h) with mask accessory) |
| Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temperature Accuracy | ±0.1 °C |
| Permeation Area | 50.24 cm² (customizable down to 0.785 cm²) |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 independent test chambers |
| Carrier Gas Pressure | ≥0.1 MPa |
| Pneumatic Pressure | ≥0.3 MPa |
| Power Consumption | 750 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | Y310-0 |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Resolution | 0.001 cm³/(m²·24h) |
| Temp Control | 15–45°C (5–50°C optional) |
| RH Control | 0% (dry), 30–90% RH |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Interface | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 100 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Compliance | GB/T 19789–2005, ASTM D3985, ASTM F1927, ASTM F1307, ASTM F2622, ISO 15105-2, YBB00082003–2015, DIN 53380-3, JIS K-7126-B |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | GBPI Y310 |
| Price Range | USD 14,000 – 70,000 |
| Testing Principle | Coulometric Sensor Method (ASTM D3985-compliant) |
| Test Range (Film) | 0.02–16,500 cm³/(m²·24h·0.1 MPa) |
| Extended Range (with Mask) | up to 260,000 cm³/(m²·24h·0.1 MPa) |
| O₂ Resolution | 0.001 cm³/(m²·24h·0.1 MPa) |
| Temperature Control | 15–45 °C (optional 5–50 °C), ±0.1 °C accuracy |
| Humidity Control | 0–90 % RH, ±1 % RH accuracy |
| Permeation Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 57.1 kg |
| Power | 1000 W, AC 220 V, 50 Hz |
| Compliance | GB/T 19789-2005, ASTM D3985, ASTM F1927, ASTM F1307, ASTM F2622, ISO 15105-2, YBB00082003-2015, DIN 53380-3, JIS K-7126-B |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | Y310 |
| Price Range | USD 14,000 – 70,000 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Y310-aa |
| Price Range | USD 14,000 – 70,000 |
| Test Principle | Coulometric Sensor Method (ASTM D3985 / ISO 15105-2) |
| OTR Range (Film) | 0.02–16,500 cm³/(m²·24h·0.1 MPa) |
| Extended Range (with Mask) | up to 260,000 cm³/(m²·24h·0.1 MPa) |
| OTR Resolution | 0.001 cm³/(m²·24h·0.1 MPa) |
| Temperature Control | 15–45 °C (optional 5–50 °C), ±0.1 °C accuracy |
| Humidity Control | 0–90 %RH, ±1 %RH accuracy |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 specimens per test cycle |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ metal tubing |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 57.1 kg |
| Power | 1000 W, AC 220 V, 50 Hz |
| Compliance | GB/T 19789–2005, ASTM D3985, ASTM F1927, ASTM F1307, ASTM F2622, ISO 15105-2, YBB00082003–2015, DIN 53380-3, JIS K-7126-B |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Region | Domestic (China) |
| Model | Y310-1 |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Region Classification | Domestic (China) |
| Model | Y310-2 |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45 °C (optional 5–50 °C) |
| Temp Accuracy | ±0.1 °C |
| Humidity Range | 0%, 30–90%, or 100% RH |
| Humidity Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Size | Φ100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 specimens per test cycle |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 100 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Y310-3 |
| Price Range | USD 14,000 – 72,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Detection Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45°C (5–50°C optional) |
| Humidity Control | 0%RH (dry), 30–90%RH, 100%RH |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions (W×D×H) | 700×560×370 mm |
| Weight | 100 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Category | Domestic (China) |
| Model | Y310-6 |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Detection Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45 °C (optional 5–50 °C) |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control | 0% RH (dry), 30–90% RH |
| Humidity Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max. Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions (W×D×H) | 700×560×370 mm |
| Weight | 100 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Region | Domestic (China) |
| Model | Y310-7 |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Resolution | 0.001 cm³/(m²·24h) |
| Temp Control | 15–45°C (5–50°C optional) |
| Temp Accuracy | ±0.1°C |
| RH Control | 0% (dry), 30–90% RH |
| RH Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Specimen Qty | 1–3 pcs per test |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 100 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Compliance | GB/T 19789–2005, ASTM D3985, ASTM F1927, ASTM F1307, ASTM F2622, ISO 15105-2, YBB00082003–2015, DIN 53380-3, JIS K-7126-B |